HomeMy WebLinkAboutBLD2005-01655 Final Garage - BLD Permit / Conditions - 2/2/2006 Inspection Line(36 0)4 27-726 2
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
irflo Shelton,WA 98584
RESIDENTIAL BUILDING PERMIT BLD2005-01655
OWNER: SHANE NAGLE RECEIVED: 9/21/2005
CONTRACTOR: ALPHA STEEL BLDGS INC 800-854-4410 LICENSE: ALPHASB117PU EXP: 7/11/2007 ISSUED: 11/16/2005
SITE ADDRESS: 415 NE BEAR CREEK DEWATTO RD BELFAIR EXPIRES: 5/16/2006
PARCEL NUMBER: 123093490030
LEGAL DESCRIPTION: TR 3 OF E1/2 SW*TR 2 OF SP#172
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
GARAGE From Belfair on Old Belfair Hwy to left on Bear Creek dewatto Rd. Left at Black
mailbox marked 411. stay straight on driveway, property on left. Look for PDI
sign.
General Information Construction &Occupancy Information Square Footage Information
No.of Bedrooms: Type of Constr.: VB
Type of Use: SF Insp.Area: No.of Bathrooms: Occ. Group: U Lot Size: Deck:
Type of Work: ACC Fire Dist.: 2 No.of Stories: 1 Occ. Load: Building: Garage-Detached 1,440
Valuation: Building Height: 17 Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: E 25.0 Ft. Shoreline: Ft. Water Body: NONE
Rear: W Ft. Slope: 60.0 Ft.
SEPA?: No
Model: Width: Ft. Side 1: S 30.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: N Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures FEES
Mechanical Fixtures
Type Qty. Type e By Date Amount Receipt
Plan Check Fee KS 9/21/2005 $306.83 S12005
Planning Review Fee KS 9/21/2005 $155.00 S12005
EH Plan Review ADR 9/23/2005 $35.00 S12005
Building State Fee ARC 10/7/2005 $4.50 S12005
Building Permit Fee ARC 10/7/2005 $472.05 S12005
Total $973.38
Please referto the following pages for conditions f this it BLD2005 01655 s o o �s permit. 1 f 9P 9 P o 5
CASE NOTES FOR
BLD2005-01655
CONDITIONS FOR
BLD20 0 5-01 6 55
1) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that
require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the
access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background.
Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted
by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting
inspections.
X . :�
2) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved
access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
X /t Z�
3) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X
5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that
require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the
access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background.
Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted
by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting
inspections.
X
6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal f approved documents will result in failure of required building inspections.
X lam`
BLD2005-01655 Please referto the following pages for conditions of this permit. 2 of 5
7) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit shall be applied for, reviewed and approved prior to the change.
X Cq
8) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X
9) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X
10) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved.
X
11) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
charged and shall e collected by the Building Department prior to any further inspections being performed or approvals granted.
X i�
12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X I/
13) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X vt
14) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or reg lat� n, must be reviewed and approved by Mason County prior to construction.
X l
BLD2005-01655 Please refer to the following pages for conditions of this permit. 3 of 5
15) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
x W,
16) All property lines shall be clearly identified at the time of foundation inspection. X
17) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordres and building regulations.
X i
18) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have preventgdpction from being taken. No more than one extension may be granted.
X
19) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures
and /or land modifications (grading, cuts, fills, etc.) required in the geotechnical report/assessment, may require a seperate permit. The geotechincal
report/assessment shall remain attached to the approved building plans. X
20) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X
21) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X ,4
22) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project.
X 44
23) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X yA
BLD2005-01655 Please referto the following pages for conditions of this permit. 4 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWNER OR AGENT: _T 1 — �1 DATE:
BLD2005-01655 Please referto the following pages for conditions of this permit. 5 of 5
I
W
o CRETE MECHANICAL MANUFACTURED HOME
0
a cn FoelFRgs i setbacks Date By Ribbons
0
rn Datel lc! � BY �1 Gas Piping Date By
Foundation Walls Date By Set-up
Date BY INSULATION Date By
BG I Slab Insulation Moors FINAL INSPECTION
Date BY Date B y Date B y
FRAMING walls FIRE DEPARTMENT
DateZ_l-06 BY Date Date By
PLUMBING Attic OTHER
Groundwork Date By -
Date By WALLBOARD NAILING
Date ^1v
D.W.Y -- ------ -—
v Date By
Watsr tine FINAL INSPECTION
Date By Date Z Z By . Date By
Tom
o Type of Insp. Pass/Fail Request Date Inspect. Date Done By Comments
CD
Go z
r
c M
01
o Cn
Z5 C _
�. .. .
coil Z
cn m
N
(D
i
t
i
i
0
I
PA 460.8r
f ........................................................:
i
�O A
PL4L a 3.W
APPRO
VED OVER
MASON COUNTY DCD PLANNING
SITE PLAN REQUIRED TO BE ON SITE
CHAPjGES SUBJECT TO APPROVAL
By — __ Date to If oS
I
... .........
�Jne 3H(
No�1o3��
�
0N1 NNb,.� ,d
Z d
s
� Z
REQUIRED BRACED
OUT OF PLANE REQUIRED BRACED WALL PANEL
OFFSET IN WALL PANEL
EXTERIOR BRACED
WALL PANELS ------------ — -------- --
-----
FF. ❑i ❑❑El El
-- -----
------- -- -----
SECTION VIEW SECTION VIEW
Figuro R3012222(1) I I I
BRACED WALL PANELS OUT OF PLANE I I I I I I
MORE THAN 1 FT MORE THAN 1 FT
EXTERIOR ELEVATION EXTERIOR ISOMETRIC
4 FT WITH 2 x 12 For SI:1 foot=304.8 mm. Flgum R301.22.2.2(5)
BRACED WALL PANEL EXTENSION OVER OPENING
CANTILEVER/SET
BACK SHALL ONLY MORE THAN B2/2
SUPPORT ROOF I�--------� IS IRREGULAR Ir—_—_-- �I
AND WALL WEIGHT r-------� (------- —
lil
I I
li ii i� B, B� it II l
I II II II
SECTION THRU CANTILEVER 4 FT WITH 2 x 12 I I I I I I I I I I
SECTION THRU SETBACK LL_____JL_===___JJ
For SI:I inch.25A mtµ 1 foot-304.8 mm. I
f_ {�—MORE THAN 81/2
F19— IS IRREGULAR
...P R3012222(2) PLAN VIEW PLAN VIEW
BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
Figure R30122.22(6)
OPENING LIMMATIONS FOR FLOOR AND ROOF DIAPHRAGMS
II II II
I I I I I FLOOR JOISTS CANNOT BE
TIED DIRECTLY TOGETHER FLOOR JOISTS CANNOT BE
TIED DIRECTLY TOGETHER
�--------II II II�I II
II II it II
,I II LL—===JL----_J
DASHED LINE INDICATES I I I I
GRACED WALL LINE BELOW U U
THERE IS NO BRACED
PLAN VIEW WALL.LINE ON THIS EDGE
OF THE ROOF
SECTION VIEW SECTION VIEW
FLOOR OR R�NOWT SUPPORTED ALL EDGES
- Flguro R3012222(7)
PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
BRACED WALL LINES ARE 1�-----�� NOT PERPENDICULAR
i
1L JL--- -
ROOF OR FLOOR SHALL BE PERMITTED II U \\\ \\\ I I
TO EXTEND UP TO 6 FEET BEYOND THE \\\ \\ I I
BRACED WALL LINE ` -------- ��----____J
NO BRACEDwALLPANEL ABOVE \---------------------J
PERMITTED AT THIS LOCATION
PLAN VIEW
Fot SL I foot=3049— I' PLAN VIEW
Flguro FW 2222(4) Flguro R301.2.2.22(S)
" ROOF OR FLOOR EXTEmSI011 BEYOND BRACED WALL LINE BRACED WALL LINES NOT PERPENDICULAR