Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2007-00804 Final SFR - BLD Permit / Conditions - 1/5/2016
Inspection Line(360)42i MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext. . Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-00804 OWNER: MICHAEL CUDNEY RECEIVED: 5/10/2007 CONTRACTOR: LICENSE: EXP: ISSUED: 6/14/2007 SITE ADDRESS: 130 NE DUSTY RD BELFAIR EXPIRES: 12/14/2007 PARCEL NUMBER: 123094490060 LEGAL DESCRIPTION: LOT: 2 OF SP#1201 PTN TR 6 SE SE PROJECT DESCRIPTION: DIRECTIONS TO SITE: New Single Family Residence State Route 3, L on State Route 300, Old Belfair Hwy, Right on Dusty RD to site address on the Right side General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: -)(- Z Occ. Load: Building:3,494 Valuation: Building Height: 26 Occ. Status: Primary Basement: COVPORCH 150 Manufactured Home Information Setback Information Shoreline& Planning Information Water Body: Union River Make: Length: Ft. Front: W 124.0 Ft. Shoreline: Ft. SEPAy: No Rear: E 257.0 Ft. Slope: Ft. Shoreline Desi Model: Width: Ft. Side 1: N 9.5 Ft. g•: Rural Year: Serial No.: Side 2: S 9.5 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee GMM 5/10/2007 $1,221.06 B12007000 Hosebibs 3 Furnace<100K 1 Planning Review Fee GMM 5/10/2007 $170.00 812007000 Kitchen Sink 1 Ventilation Fan 5 EH Plan Review TW 6/4/2007 $75.00 b12007000 Lavatories 5 Heat Pump 1 Building State Fee ARC 6/11/2007 $4.50 bizoo�oob Showers 1 Dryer Vent 1 Building Permit Fee ARC 6/11/2007 $1,878.55 612007000 Water Closets (Toilets) 3 Mechanical Fee ARC 6/11/2007 $92.20 B12007000 Water Heaters 1 Mechanical Base Fee ARC 6/11/2007 $25.30 B12007000 Bath Tubs 1 Plumbing Fee ARC 6/11/2007 $113.30 B12007000 Clothes Washer 1 Plumbing Base Fee ARC 6/11/2007 $22.00 612007000 Total $3,601.91 BLD2007-00804 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2007-00804 CONDITIONS FOR BLD2007-00804 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 2) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X P-/L f 3) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X I"c.e 4) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X lwl-, " 5) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X R4/_ 6) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X&/e 7) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X/M -� 8) Applicant must remove existing manufatured home on property before final building permit approval/issuance X,0,44e 9) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 10) This parcel is located in a smoke management zone. Please contact a fire warden at (360) 427-9670 ext. 459 for further information. X BLD2007-00804 Please referto the following pages for conditions of this permit. 2 of 5 1`1 All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approvMwi,. hot be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 1,11 1 12) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X inn L_r 13) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X mLe 14) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. XNJ C 15) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X_;,, i e 16) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X 11ALC 17) Per 2003 IRC - SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X i'Yt LA_ 18) Per 2003 IRC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X 1A i 0 19) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X n1 L G BLD2007-00804 Please referto the following pages for conditions of this permit. 3 of 5 n 20) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building 'Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X �1\1_e 21) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X VIA 1.0 22) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X M LC 23) All changes to approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X din L 24) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X wI L-r 25) All property lines shall be clearly identified at the time of foundation inspection. X 26) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X J1nk C 27) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X t,"L C. i BLD2007-00804 Please referto the following pages for conditions of this permit. 4 of 5 Im.. Z8) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X M(-c 29) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X M This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for revi and inspecti n. OWNER OR AGENT: DATE:1D BLD2007-00804 Please refer to the following pages for conditions of this permit. 5 of 5 f CONCRETE �'r'"'� MANUFACTURED HOME Interior-Date By . Footings!Setbacks Ribbons E.xia `-Date Ely Date By INSULATION Date By Foundation WaIts BG I SLAB INSULATIOTI Setup Date By Date By Date Bly FRAMING Floors FIRE DEPARTMENT abate BY Data $y Da a B' Walls PLUMBING Date By DECKS Date By vaultGroundworkTANKS Efate BY Date By Date BY Attic _ a.w.v Bats By OTHER date BY DRYWALL Type _. Date BY VftterLine Late By Type. -0 Date By I nt,Brace Wall Date By te MECHANICAL °� �erat ByFINAL. INSPECTION CD on m Dam By date BY date Sy ° Pass or Req uest Inspect CD Type of insp. Fail Date Date Done By Comments o 0LOX— � i Ln tt i o i I c� 0 2 in k in S CD E I CD O i ao o' CONCRETE MECHANICAL MANUFACTURED HOME n CD N C o Footings/Setbacks Dater- Ly f� By - Ribbons Z Gas Piping rTl o Interior Date By Interior-Date By Date Fay Co CD Exterior Date By Exterior-Date By Setup v Point Load!Isolated Footings INSULATION Date By 0 BG!SLAB INSULATION = Date By Data By FIRE DEPARTMENT D Foundation Wails / Floors Date By r Date � ?- U�( Byl,W(4 Data By DECKS FRAMING Walls Date By Date a—z- /( By Data f _ S" z By PROPANE TANKS PLUMBING vault Date By. Date By OTHER Groundwork Attic Type: Data By Date By Date By D.W.v DRYWALL ./ Z Type_ InL Brace Wail Date By W Date -L By Date By FINAL INSPECTION 0 v Water Line / Fire Seperation hl Date By Date By Date BY y m Pass or Request Inspect. o 0 Type of Insp. Fail Date Date Done By Comments c ,ems ► ��=nr,�� ©�P � CD Cn 8 G✓al lwwa 1 9 %2' a �r'r����GSS `T2''XTt—'P z m f V2 �to 17 ,•c� ,��R � cc f= �'/2 r/a ro f - i 1X/V 7L' r✓ _-rU�s� Z c�j°or/ ovo• r �t� �H�- S rs G�` J� C f}L - � go v LA o �x ►�'J9«' I�Sc`(fir/o.✓ � ! �L ��s'-r 3�q I I I ' '`1�t, IK, ITT r-,.,� r I✓G�1 Building Permit #' 242:>7c'tagb4'/ MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location ><.3c� This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been und: Items Listed below must be corrected to gain code compliance YC �S You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department l Date 6 `IY-1Z Inspector moos NOT M4 *V THU- T A Permit# 67 �d MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 1 3o p1= ��-s 1 v �r This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance w ►r e) o 1,6e%j c,^ t4�c 7-4 a ro y be�t,)yee-,ag Z ` I C411 �3 7 ePG,�tT/•.1�ic,s s +.44 u�i�s1 Pay 4tec + c��Tle. r dXcs eft k -- 1 At �g-r. PSI ram#— _ You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Please contact our office Make corrections, items will be checked on next inspection regarding possible structural OK to t %tY ��+; r� damage incurred by recent 49natural1man made" ❑This is not a c mplete inspection disasters.This is NOT a Date Department LCORRECTION NOTICE. Inspector V* N�L OT 1?, t-1 o *4 ; ' THIqx r _ omm M09y December 12, 2007 I Michael E. Cudney and Marie L. Cudney residing at 130 N.E. Dusty Road Belfair Wa. 98528 do hereby request and extension on our Building permit for the following reason. On June 14, we picked up our Building permit and at that time we were still living in our Mobile Home and was trying to either sell it or give it away. We had no one interested and thought it was because it was too old of mobile home. It was a 1982. We decided that we couldn't wait any longer so we started demolition. We are trying to save as much of the material as possible so that we can use it for some other project. It has taken longer then we aniticipated to tear the mobile home down to where we can have someone start our foundation for the new structure. We realize now that we shouldn't have submitted our house plans until we had the mobile home completely tore down. Michael E an Marie L. Cudney � O o u �S�7-� 71..L.L�► �1 �-�d►'1�S c1s � - S _ ;-ate C ��}-y C�n� w► C�ZD� Z►-'d a'r` � N© � G� N C NZ� a-D N a--�