Loading...
HomeMy WebLinkAboutBLD2022-0752 MFG Home - BLD Inspections - 8/14/2024 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 t , COMMUNITY SERVICES SHELTON:360-427-9670, EXT 352 BELFAIR:360-275-4467,EXT 352 Building,Planning.Environmental ila lth,Community Health ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY`* To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2022-00752 Date Issued 08/03/2023 Issued By Project NEW MFG HOME Site Address 603 E INSPIRATION WAY Applicant EMPIRE HOME CONSTRUCTION LLC Contractor AMERICAN HOME CENTER Contractor Phone 1.253.841.3600 Primary Code 20P1C8 IBC,IRC,IFC,IEC,IMC,& Type Permit Type MANUFACTURED HOME Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final U (� Building ) g Department Building Official: Community Services Designee Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building ManufacturedHome Setbacks /�S/�3 �� Setup I l / L Concrete Foot/Runners Final (Z q Other C-,ravw>` C,," 212312�{ _-Z �u ok - Gas ►`N1 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: &7-> 2Q z2-- Qn 7Sz ADDRESS/LOCATION: (go' E Trtis(J�roc�lun ljan FINDINGS: d I n-� D6e r- ott- Loos.,?- A-(4 "�)6ry,-L W-C- 100F 1 " or � Y W, AV— o -) }aktn No!- t 1 o& QIJ [A5AeJ -d �- Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. �❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: 3 f 2-1 /2 q ❑ Please contact our office regarding possible Department:—L-) structural damage incurred by recent Inspector: '�G� "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BLD2022-00752 MANUFACTURED HOME PROJECT DESCRIPTION: NEW MFG HOME ISSUED: 08/03/2023 SITE ADDRESS: 603 E INSPIRATION WAY SHELTON EXPIRES: 01/30/2024 PARCEL: 120303190082 APPLICANT: EMPIRE HOME CONSTRUCTION LLC OWNER: EMPIRE HOME CONSTRUCTION LLC P0 BOX 241 P0 BOX 241 KELSO,WA 98626 KELSO,WA 98626 1.360.751.8062 GENERAL CONTRACTOR'S LICENSE: AMERICAN HOME CENTER License: AMERIHC9780C 406 108TH ST S Expires: 09/03/2023 TACOMA,WA 98444 1.253.841.3600 FEES: Paid Due Planning Review Fee $240.00 $0.00 Technology Surcharge $12.60 $0.00 State Fee-Residential $6.50 $0.00 Modular/Manufactured Home $275.00 $0.00 Fee- 1st half collected at submittal Building Plan Review/Change of $130.00 $0.00 Use-Onsite Sewage Modular/Manufactured Home $275.00 $0.00 Fee-2nd half collected at ready to issue Building Plan Review Revisions $80.00 $0.00 Totals : $1,019.10 $0.00 REQUIRED INSPECTIONS Setback Inspection Connection has been verified by Health or Utilities Footing Inspection BLD-Final Inspection Printed by:Genie Mcfarland on:08/03/2023 08:12 AM Page 1 of 5 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov MANUFACTURED HOME BLD2022-00752 Set-Up Inspection CONDITIONS * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. Printed by:Genie Mcfadand on:08/03/2023 08:12 AM Page 2 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov MANUFACTURED HOME BLD2022-00752 * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (NCSBCS/ANSI A225.1). * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * All property lines shall be clearly identified at the time of foundation inspection. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indicated on the plot plan. * REQUIRED INSPECTIONS (Footing Inspection-prior to pour(set-up manual must be on-site), Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved)by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWNER/CONTRACTOR(indicate which) * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M. Support configuration shall be clearly marked in the installation instructions. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Genie Mcfarland on:08/03/2023 08:12 AM Page 3 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov MANUFACTURED HOME BLD2022-00752 Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three feet of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. Certification number and signature of the certified installer responsible for each major part of the installation. WAC365-210 * Setbacks are twenty-five feet from front,twenty feet from sides and rear. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/ Reserve area. * The bottom of all footings must be a min. 12" below existing grade. Any gravel used to level the site must be compacted to 95%. Mason County Building Department requires a site inspection prior to placing the home to ensure the minimum requirements have been achieved. Printed by:Genie Mcfarland on:08/03/2023 08:12 AM Page 4 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. C Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-00752 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: Printed by:Genie Mcfarland on:08/03/2023 08:12 AM Page 5 of 5 t�GDZG22-Qo7sz mom cm cwmo �t tNft'� RAI Intl 'KETAILs UAREW , . APPRM W""SMCOMREVIEWED FOR CODE COMPLIANCE MASON COUNTY BUILDING DEPARTMENT OaCr�m4nt�a►thc�ad tp e�mVed �ana� ,: R �..t.. ...,, COON/ aa�Y to nl - �z -pWk I �erp(avr,F410k REVISED E C- DATE 7-Z S-Z 3 �a 04) CAA � � 4- A) SITE ;er REVIEWED FOR 0:'*AdS CODE COMPLIANCE COPY ,S` -p,4eJ kj ?"-r Fly MASON COUNTY B U I L D I N G D E PA RTM E I\ T 13 CARPET LAYOUT STANDARD CARPET C A - LINT CC) 0 Nay 50 80 3920 4880 20 40 1840 4000 60 80 54M 6880 --- ----- --- 3', L,2. 111. 3-� REVISEU ARPET 20 40 2920 60 so ,,7 960 1012G B - UNfT THESE PLANS MUST BE G'N THE JOB SITE FOR INSPECTION See (46(t 7& (oS ?�aej poor- t:>es;5vL tAa4e( (2,- 14A d, Cro Manufacturing West,Ina Albany Dlvlsian-PI-1 1972 24451,1- lACIlIC BLVD.1 ALBAN,, ,97321 Ph—(541) 126-8931 y," rlrt (866) 491-6347 o"w -r"s(w-Cfqd CARPET & PIER LOC. i4ok-e, —.1——11.IT! 6" WALLS FOR QUESTIONS REGARDING FOUNDATIONS OR SETUP OF HOME CONTACT SITECOMPLETIONW@CLAYTO m - NHO ES COM TEMPO -;M-2456-3A p SET-U NOTES: a 1,326 PIERS REG' BODE&HIGH CENTERLINE PIERS RM BE LOCATED UNDER RIDGE I THE STANDARD CONFIGURATION OF THIS HOME MAY HAVE BEEN go I I O� MODIFIED' A CUSTOM PRINT SHOULD BE PROVIDED. IF NOT,THE PIERS PER TABLE THROUGH SEE TAKE lmq INSTALLATION BEAM SUPPORT Posn. sEr-up CONTRACTOR sHALL CALL CMP.MANUFACTURING WEST FOR I—A 9 ■ 5C OF INSTALAT105N MANUAL FOR SPACING AND LOADINS A CUSTOM PIER PRINT. Install Footings each of the label locations.Additionally,perimeter support locations may be identified by a pier located near the end white stripe or mark beneath the home on the bottom board material.Perimeter blocking of eacthere is no more such tha that supports must be placed no further than 8 feet on center. 24 inches as measured from If required,perimeter supports are only needed on bearing walls.For 20 psf roof live load, the outside edge of the perimeter support is only required at exterior doors and other openings 4B"and larger,un- floor to the center of the less noted otherwise.Supports may be added at each corner of each endwall for leveling pier. purposes,but are not required.Bearing walls are those walls that support the ends of roof trusses or rafters(typically sidewalls and marriage walls but not end walls of main units or sidewalls of tag units). To minimize the number of required perimeter supports,space them evenly between point load Supports as shown in Figure 9 and Figure 10(but not under open spans).These fig- ures identify typical support locations for homes requiring perimeter supports. PERIMETER DOORPIERS Figure 9. Typical support lo- BLOCKING PIERS' -_I_B� cations for homes requiring FRAME perimeter supports MEMBERS J---9E- I-B�MFRAME_4____ 0- ElOPTIONAL MARRIAGE CORNERB- -_B- �- -aH WALL PIERS PIERS _9 _� -8- � FRAME PIERS -C-J- $- -e- -C:1 -i3- PERIMETER 1BEAh1PORCH PO BLOCKING FRAME MEMBERS PIERS DOOR PIERS- Figure 10. Typical marriage DOOR OR OPENING LESS line support locations for THAN 48 IN.IN WIDTH COMBINED SPAN(A+B) homes requiring perimeter _ - — supports RIDGEBEAM COLUMN POST OR WALL LESS THAN 16 IN.IN WIDTH SPAN J P N B SPAN A _ - --_-- TMAIN I-BEAM t FOOTING FOOTING FOOTING FOOTING FOOTING FOOTING SIZED AND SIZED FOR SIZED AND SIZED FOR SIZED FOR SIZED FOR SPACED TABLE 7ER SPAN C TAB E 5 R SPACED PER7 SPAN TABEPS R SPAN A+B PER TABLE 5 SPAN R ABLE 5 CALCULATE LOADS r Use Tables 7-7c to determine the loads on frame and perimeter supports for homes requir- in &**VZ g perimeter blocking.Find the chart with the appropriate sidewall eave overhang.Then, A perimeter support must be find the column with the appropriate roof load and section width.Find the group of rows cor- installed within 4 feet of col- responding to the selected support spacing.The values in the intersecting cells are the umn supports and the corner loads for the frame,perimeter and marriage line supports respectively. of the home when the home is Loads on supports Of a given type(frame,perimeter or marriage)can be assumed to be designated for perimeter equal if support spacing is equal.However,if different support spacings are used then each blocking.The loads listed in support with a different spacing should be calculated separately. Tables 20 for or hornes roof load realer Loads for piers installed at 5,7 and 9 feet on-center can be estimated by adding the loads I cn Q a3 m I a " N m a $ o w o ey� o NH N Q N Q W m VNI OO tmlf e N • y .N N N' tm'1 em+ In Z m ti l0 N^ t0 QOI tp N, N Imf1 m m .'1 N n N b lO'1 `� :✓ G 'If.~ J:/�� I U O1 m to r N N �!1 N Ot p.� rl N m N m {n m Y tD Q ry V• � �/\ ` W pp pp { o ,^ N pp p O. S N N l0 1p IW.1 f R P N N 1' x N' O O I IW.1 O O Y O N 'Q O .;m W 011 O1 N n N W U1 Itl Y O aa \p` N m N .-1 G m OO m Z N rl e1 N N N i Y N T u1 m Z N ti d t0 N tp ti N' b o T o O c .I N i0A ti' n N N V1 N O lo i m Vt y. g Q m O n n M n T p l M 6 d M n d C IA m O N � P N f0 Z t 6 N m < O < tO O V�1 aONO G N ONO OppOWp f N O�p N l0 O i 0 '3 1 m ti N N N < tN'i M emil .W1 C N N Of on n m I N t 1 i W: 'O O: b 0 0 0 t0 O O� Wf Olo Wm W O $ W O m Q N b W SR N rl �-1 N N N m N I N I Y m Z N .�Oi M u1 N VI W N �O T S p p N a I q .N ei N m O O Y Gl O� O Q N O1 01 �D N Y I O v1 01 I m C Cao eO1 n n .N-1 T tN0 N Imn m 00 O n b N Vmf .Z OC -�' Nm YN1 N lYn O ti I N IOI o, On1m _S Q ONO C `1S IQ/1 O1 N N Y iC0 On1 N L I yOj m P I (mV pOj COp CQp C lOD < Z Y AND O Cm0 N C e~i I Qm I� T 4 m f N Q i n N u1 01 T W N p �Op m p N w mmi N! Q I N N w {O N O N N o a 3 a 3., a m 3I a o a A y a ml uI a' m ml a 3+ m F j LL � c� ILL y ci tL N cpc 1L O LL y� CC� LL � CC� LL N CCq LL e iD s o m io ao I e a a o I o to co 00 oe o `a t An A "a i iA A n( n n FootingsInstall TABLE 7c.LOAD ON FRAME AND PERIMTER PIER FOOTINGS FOR HOMES REQUIRING PERIMETER BLOCKING(LBS) Roof Load Zone and Max.Home Width(24"Max.Sidewail Eave Overhang) Pier South(20 psf) Middle(30 psf) North(40 psf) North(60 psf) Spacing Location 20 ft 24/36 it 2a/4ZA 32148 ft 20 ft 24/36 ft 28/42 ft 32148 ft 20 ft 24/36 ft 28/42 ft 32148 It 20 ft 24/36 ft 28/42 ft 1 32/48 ft Up to 4' Frame 1420 1624 182.8 81 1420 1624 1828 1981 1420 1624 182m, 1981 1420 1624 1829 1981 Up to 4' Sidewall 1400 1520 1640 1730 1680 1840 2000 2120 1960 2160 60 2510 2520 2800 3080 3290 Up to 4' Marriagewall 1760 2000 2240 2420 2 0 2480 2800 3040 2560 29 3360 3660 3360 —3920 4480 4900 >4'to6' Frame 1930 2236 2542 2772 1930 2236 2542 2772 1930 2236 2542 2772 1990 2236 2542 2772 >4'to 6' Sidewall 1900 2080 2260 2395 2320 2 0 2800 2980 27 3040 3340 3565 3560 4000 4420 4735 >4'to6' Marriagewall 2440 2800 3160 3430 3040 3520 4000 4360 3640 4240 4840 5290 4840 5680 6520 7150 >6'to 8' Frame 2440 2848 3256 3562 2440 2848 .56 3W 2440 2848 3256 3562 2440 2848 3256 3562 >6'to 8' Sidewall 2400 2640 2880 3060 2960 3280 360 3840 3520 3920 4320 4620 4640 5200 5760 6180 >6'to 8' Marriagewall 3120 3600 4080 4440 3920 4560 52 680 4720 5520 6320 6920 6320 7440 8560 9400 >8'to10' Frame 2950 3460 3970 4353 2950 3460 3970 43 2950 3460 3970 4353 295 33460 3970 4353 Pier North(80 psf) N h(100 psf) North(120 psf) Spacing Location 20 ft 24 ft 29/42 ft 32148 ft 20 ft 4 ft 28/42 ft 32148 It 20 ft 24 It 28/42 ft 32/46 ft Upto4' Frame 1420 1624 1829 1981 14 1624 1828 1981 1420 1 4 1828 1981 Up to Sidewall 3080 3440 3800 4070 640 4080 4520 485U 4200 4720 5240 5630 Up to 4' Marriagewall 4160 4880 5600 614� 4960 5840 6720 7380 5760 6800 7840 _BG20 >4'to 6' Frame 1930 2236 2542 2 2 1930 2236 2542 2772 1930 2236 2542 2772 >4'to 6' Sidewall 4420 4960 5500 590S 5260 5920 6580 7075 G100 6880 76G0 8245 - - >4'to 6' Marriagewall G040 7120 8200 9010 7240 8560 9880 10870 9440 10000 11S60 12730 -'-- >6'to 8' Frame 2440 2848 325 3562 2440 2848 3256 3562 2440 2848 3256 3562 >6'to 8' Sidewall 5760 6480 720 7740 6880 7760 8640 9300 8000 9040 10080 10860 >6'to8' Marriagewall 7920 9360 10800 11880 9520 11280 13040 14360 11120 13200 1S280 16840 >6'to 10' Frame 2950 3460 3970 4353 2950 3460 3970 4353 2950 3460 3970 4353 AGAG PRE '7t AIC � S '•.; 9'•.• ,� STEP 4. SELECT FOOTING MATERIAL '.,��,y�0 0'f 0 •. \,� Select one of the products and materials from Table 8 for the footings. /�/I11111t11�11 TABLE 8.FOOTING MATERIALS Material Appropriate Use Specification Minimum 6"thick poured-in-place concrete pads,slabs,or ribbons with at least a Poured concrete All soil types 28 day compressive strength of 3,000 psi.Cast-in-place concrete footings may also require reinforcing steel based on acceptable engineering practice,the design loads,and site specific soil conditions. Minimum 4"thick nominal precast concrete pads meeting or exceeding ASTM C Pre-cast concrete All soil types 90-02a,Standard Specification for Load Bearing Concrete Masonry Units,without reinforcement,with at least a 26 day compressive strength of 1,200 psi �^ Use in accordance with the pad manufacturer's instructions.Must be certified for AB plastic Per Pad Manufacturer's use In the soil classification at the site,listed or labeled for the required load capac- Instructions ity.May be placed directly on soil or concrete. Propdetary systems Consult system manufac- Consult system manufacturer turer --...___. 30 Install Footings owfootings be Concrb'te? 1111. YES, •• toFOOTING, • 00- • •• to Set the o STEP 5. SIZE FOOTINGS Once the load on the footing and the soil bearing capacity are known,calculate the size of each footing as follows: 1. From Table 9 determine if the pier is to be of single stack blocks(8 inch x16 inch)or double stack blocks(16 inch x 16 inch). 2. Locate the group of columns in Table 10 with the soil bearing capacity deter- mined in Prepare the Site,STEP 5.DETERMINE SOIL BEARING CAPACITY AND FROST LINE(p. 17).Use the next lowest value if the exact value does not appear. 3. Find the row corresponding to the pier capacity required by Tables 5,6 or 7. Then,read across the table to determine the minimum required footing area for the corresponding pier capacity and soil bearing capacity. 4. The required footing size and pier capacity may be changed by selecting differ- ent support spacing. TABLE 9.PIER CONFIGURATION Maximum load(Ibs) Pier Con- Height Configuration Without With figuration Mortar Mortar Single stack blocks with long side Single Less than 36 in' perpendicular to frame I-beam or 6,500 7,680 Stack parallel to perimeter rail(rim joist) Double 67"Max. Double,interlocked blocks 13.000 15,360 Stack Triple 67"Max. Triple,interlocked blocks 19,500 23,034 Stack Double 108"Max." Double,Interlocked blocks NA 39,500 Reinforced Single stack piers may be constructed up to 54"max.height only when installed as p rimeter and rnardaq�e line support piers. erence maximum allowable pier height with maximum floor height listed in frame tiedown charts.If maximum height listed in frame tiedown charts is exceeded then designs must be provided by a registered professional engineer or registered architect. <VIIN ti i� • AGRIC E 001.0 9• 31 Ph. 951-674-4oll - Fax 951-674�720 www.SedcoPier.com -sedcoPler@verizon.not 33320 Mission Trail-Wildomar, CA 92595 Max Pier Leads PSF lilt 1 8011 Capacity(Psi) Design Load Ob) 2377 3565 2000 4753 7130 ;.�,}� Q Can be used with concrete blacks or steel piers i8.376 ab*5 MoWed in Pad Model#BP1818 2) Smooth Side Down 3) Installer responsible for determining soli bearing loads and capacities 4) Mant,rfactured bySedco Pier Inc. Y. PlcrTiK m A D Graf-Ia Con,"DDSH19S *U—SA* Listing#1165 ��o w�,Sy�� 14171? SSt�NAL 4-40 147-41 I r' Ph. 951-674,4011 a Fax 951-674-5720 www-SedcoPier,corn a sedcopier@verizon.net -- :_ .I 33320 Mission Trail -Wiidomar, CA 92595 Base Pad l ftlftl '01 Model# BP1616 9. O I IIII IN JU ) W&01er Loads PSF i Soil Capacity(pso Design Load (lb) 1000 1778 1500 2667 .. _........... - I6.080 2000 3556 ' 3000 5333 I Can be used with concrete blocks or steel piers. The pier is to be either a single open cell concrete block configuration,a double stacked open cell concrete block application,or a steel pier aplicatlon (to be consistent with tho RADCO Listing#1355, i section 5,d) Secure metal piers to pad with:(CA only) 4•#.14 x 1.112'screws or 4-##10 x 1-112"screws Label Molded In Pad 1) Model#BPI 616 2) Smooth Side Down p Q 3) Installer responsible for determining soil bearing loads and capacities 4) Manufactured by _i Sedco Pier Inc, _. o �dco Plr/n<. 5) ` Listing 41355 * S '100% Pr'erniurn -- M A D E ' Install per RADCO listing#1355 or manufacturer's Grade Composites �� +USA* ty p published installation instructions. ENGINEER APPROVAL ._ STAVE APPROVAL o 1�?'uz D Digitally signed 4�1 °F wAsti�yq�9 by Lorenzo Cruz y Dimalanta Date: GIs 1� � 2019-10-18 16: NAL 02:21 www.sedcopier,.com ® 95 i .674-4011 Plea 951-674 4011 d Far,9510674.5720 WNW.8edcoPiencom a sedcopler@verizon.net 33320laslioB3 rd'a9g Wifcioinar, CA:3295 Base Pad 24x24xj t5J . Max Pter Loa is FSF i SDU Capacity(pao Design Load(lb) D1000 4000 f 1500 6000 2000 8Q£t0 ts:,oac 3000 12000 Rj Can be used wMi concrete blacks or.steal piers 1 _ ' (� (Label itliallded in Pad 1) Model t BP242=1 2) Smooth Side Dovvn 3) installer responsible for determining' soil bearing loads and capacities 4) Manufactured by Sedoo Pier Inc, Y 8{Ra14' Prey-Muni jrlri�� Q a c] 7 Grado 4'Omposltea = "" 5) Listing nsm A ENGI ! APPROVAL STATE APPROVAL co t 141 fONAL Gti PACIFIC CONSULTING ENGINEERS 2150 Bell Ave.Suite 145•Sacramento,CA 35838 i PH.(916)664-6625