Loading...
HomeMy WebLinkAboutPAR2008-00002 Hot Mix Asphalt Plant - PAR Letters / Memos - 1/9/2013 123212490020 123211300060 123211400000 12321�76000 0 I � f 123212490030 123212400010 123212400000 ,.123211390051 123211390052 123211400041 t 123219999999 r 123217500010 123213190011IL as ; 123213190022 123213190010 123213190012 1 � 123213101000 23214200070 f 123214200060 ' 123214290082 123213190051 � '� r '• -�" �f 123213190070 f ' * 123214290083 ' r 123213101020 4 '" ' 123213190052 + 123213190040 ' 123214290081 123213100031 d *< "j 123214290084 � ,f 123213190034 123219999999 " 123213102000 123214200090 123213190033 my 123213400030 � 1..• x � � � ��� tom'.-. i 123213400010 Q �. p< ` 123219999999 ; 2321430000011, " NE PEN�r� 123214300010 123214300130 „ . 123214400000 . 123213400030 ' ' ! ,-�„� 123214360100 123213490080 123214300110 123213490070 123214300120 t. " ` "i+►` 123213490050 123213400000 N 1 inch = 300 feet W E 1 inch = 0.06 miles S Information for permit: PAR2008-00002 Page 1 of 3 MASON COUNTY Washington Government • Information BrochuresIMF Mason County Home Employment Forms& Codes&Regulations Community Links Visit Mason County « . . Boards Building Dept Some information I cases may not be displayed This information may be outdated and inaccurate Planning dept Information is only for the unincoporated areas of Mason County and may only show items since April 1st, 1992 Environmental Health Please contact the Permit Center(360)427-9670 ext 352 to verify any information Dept This information was last updated: 01/09/2013 at 9:05 am Building permits are NOT ready to issue until Case Status is APP and an activity"Approved for Records Issuance" is listed New Search information for Permit: PAR2008-00002 Assessor I Treasurer Case PAR2008-00002 Parcel Information Number ERIC CLEAVER Case Status P.O. BOX 1571 REC Applicant Parcel 123214200090 KINGSTON WA 98346 Number Project NE PENINSULA BLVD BELFAIR Address Valuation 11 $0.00 Description PROPOSED GRAVEL/SAND STORAGE AND A HOT MIX ASPHALT PLANT.ALL COMPONENTS OF PLANT WILL BE PORTABLE. Activities Date Date Assigned Done Description Assigned Done Status To By Public Works Review 01/10/2008 02/25/2008 DONE JES JES Public Works was not present at the pre-app meeting. The following comments are based on information submitted and a phone call with Mr. Cleaver Access: Contact Washington State Department of Transportation for access requirementss to State Route 3. Stormwater: Title 14 Chapter 14.48 of the Mason County Code shall be met for stormwater requirements.The county currently uses the 1992 Department of Ecology Stormwater Manual for the Puget Sound Basin.The 2005 Manual has been adopted in the Belfair UGA and may soon be used in that UGA once an ordinance is passed. Planning Review 01/10/2008 02/05/2008 DONE JMS JMS Pre-Submission Conference for Eric Cleaver The proposal involves the construction/placement of a portable hot mix asphalt plant and will also include the storage of both sand and gravel.The proposal also includes the placement of a portable http://www.co.mason.wa.us/permits/main.php?caseno=PAR2008-00002 1/9/2013 Information for permit: PAR2008-00002 Page 2 of 3 building that will serve as the office. The proposed location of the project is NE Peninsula, Belfair UGA, and the parcel#is 1232142-00090.The working staff of the asphalt plant is listed as two people in the applicant's notes. The applicant's also notes that a portable toilet will be placed on site for both customer and employees'use. During this meeting I gave the applicant a copy of the Belfair UGA Zoning Code (17.24.200"Bi"Business Industrial District)that would apply to the use of the proposed parcel and a copy of the Landscaping Requirements(17.31.020)for the proposed site. SEPA:The applicant will need to submit a SEPA checklist for the proposed development. The County will act as the lead agency but applicant will also have to apply for a separate air permit from ORCAA once the SEPA permit is given. ZONING:The parcel(12321-42-00090)lies in the Belfair UGA area and is zoned(GC-BI)General Commercial-Business Industrial and the proposed land use fits with the land use profile as stated in the Business Industrial section(17.24.200). SETBACKS: Section 17.24.250 addresses both the Bulk and Dimensional Standards that requires a front yard setback of 30 feet along SR-3 and 15 feet on all other streets. HEIGHT: MCRD 1.03.032 C. Maximum height restrictions shall not apply to storage silos, antennas, transmission towers,water tanks on lands in all zones and on Resource lands; and shall not apply to incineration facilities, boilers, electrical or generating plants,or industrial facilities on lands zoned as industrial areas. In addition. BUFFERS: Vegetated buffers are required for the proposed project under chapter 17.31.020.G. CRITICAL RECHARGE ACQUIFER AREAS:The parcel does not lie within any critical recharge areas. CRITICAL AREAS: No other apparent critical areas affect this parcel this includes both wetlands, streams;this includes any types of slopes that would require a Geo Technical Assessment,There are two streams in the vicinity. One is on the west side of the property and is approximately 300 ft from the property line,the other runs parallel to the southeast border of the property line and is approximately 400 ft from the nearest property line. Please call me at(360)427-9670 extension 294 if you have any questions. Environ.Health Review 01/10/2008 01/31/2008 DONE PJO I just heard from the building department that they are not requiring that your proposal include running water and restrooms in your office structure. Environmental Health will accept a portable restroom but it must incldue hand washing facilities. Building Plan Review 01/10/2008 01/30/2008 DONE ARC 1. Office building(trailer)will need to be L&I approved with install requiremnents. 2. Floor plan is required to show all area and items to fiqure out occupancy of the area(class"B"), also show all exits and where fire extinquisher location. 3. set backs from all other structures shown on a to scale site plan. 4, plans showing how going to meet ramp construction for ADA requiremnts entering office.walk ways and car parking with barriers. 5. Proposal for restrooms that meet ADA requiremnents and EH requirements for gray water disposal and water to building per bld code. hftp://www.co.mason.wa.us/permits/main.php?caseno=PAR2008-00002 1/9/2013 Information for permit: PAR2008-00002 Page 3 of 3 Fire Marshal Review 01/10/2008 01/30/2008 DONE LAW A fire apparatus access road needs to be installed to Ordinance#31-04 title 14 chapter 14.17 of the Mason County Code. Fire flow is provided on site, note than the hydrant needs to be within 400 feet of the furthest point along the perimeter of the building or equipement. Fire extinguishers will need to be installed per the 2006 IFC chapter 9.The diesal tank used to fuel the asphalt plan will need to be a UL certified tank and meet the set backs per chapter 34 of the 2006 IFC.A knox box installed per chapter 5 of the 2006 IFC will need to be installed.The asphalt storage tank if part of a trailer as stated during the meeting will need to be a DOT approved tanker and meet the set backs as set in chapter 34 of the 2006 IFC. Meeting 01/30/2008 DONE BKD BKD APPLICANT: ERIC N CLEAVER MEETING DATE/TIME:JANUARY 30,2008, 1:15/1:30-2:30PM PARCEL NUMBER: 12321 -42-00090 SITE ADDRESS: NE PENINSULA, BELFAIR UGA PROJECT DESCRIPTION: GRAVEL/SAND STORAGE AND ASPHALT PLANT. MEETING LOCATION: BUILDING III PLANNER: JIM S., EXT. 294 E.H.: CINDY W., EXT. 353 NOTES SENT 2/26/08 Application Received 01/10/2008 DONE CMH Permit Fees Fee Type Amount Due Amount Paid Planning Pre-App Fee $240.00 $240.00 Total Fees:$240.00 $240.00 Amount Outstanding:$0.00 Conditions No conditions on this case This information was last updated: 01/09/2013 at 9:05 am Information may be inaccurate and outdated. Please refer to the Permit Center to verify any information Building Planning Environmental Home Home Health Home Disclaimer Search our Site http://www.co.mason.wa.us/permits/main.php?caseno=PAR2008-00002 1/9/2013 Information for permit: PAR2O03-00008 Page 1 of 3 MASON COUNTY Washington " Governmentt ! Mason • - Employment Forms&Brochures County C• :w Info. Campus Codes&Regutations COMMunity Links visit MasonAdvisory Building Dept Some information/cases may not be displayed This information may be outdated and inaccurate Planning dept Information is only for the unincoporated areas of Mason County and may only show items since April 1st, 1992 Environmental Health Please contact the Permit Center(360)427-9670 ext 352 to verify any information Dept This information was last updated:01109/2013 at 9:05 am Building permits are NOT ready to issue until Case Status is APP and an activity"Approved for Records Issuance"is listed New Search Information for Permit: PAR2003.00008 Assessor/Treasurer Case PAR2003- Parcel Information Number 00008 STEVEJOHNSON Case Status FIN Applicant P.O.BOX 488 Parcel 123214200090 BELFAIR WA 98528 Number Project 101 NE PENINSULA BLVD BELFAIR Address Valuation -' $0.00 Description Steve Johnson-proposed installing a portable asphalt plant. Activities Date Date Assigned Done Description Assigned Done Status To By Pre-Application Reiew Complete 03/11/2003 DONE SRG notes sent Fire Marshal Review 01/30/2003 03/06/2003 DONE SAS Need mor info,i.e.specifics about the process.2000 gal.propane will require review and permit. Planning Review 01/30/2003 02/13/2003 DONE ram RAM Per discussions with Darren Nienaber, Ron Henrickson,and Bob Fink, no planning related permits will be required.Setback requirements are 50'from all property lines for all structures. Environ.Health Review 01/30/2003 02/12/2003 DONE ADR If a bathroom is required,a public water system and a properly sized drainfield will be required. If a port a potty is allowed,we reccomend a unit with some type of hand washing. Public Works Review 01/30/2003 02/12/2003 DONE AAT AAT http://www.co.mason.wa.us/permits/main.php?caseno=PAR2O03-00008 1/9/2013 Information for permit: PAR2003-00008 Page 2 of 3 The proposed activity falls within Ecology's Standard Industrial Catagories(SIC)of 2911,and/or 2950, and is required to obtain an NPDES Permit.Washington State's Department of Ecology should be contacted by the applicant regarding obtaining an NPDES Permit.Local review of the NPDES Permit for Stormwater Management/Runoff issues will be Alan Tahja,available at County extension 461 or at email address;alant@co.mason.wa.us Meeting 02/05/2003 DONE CMH SRG Steve Johnson-Peninsula Topsoils,LLC February 5,2003-10:45/11:00-12:00 Parcel No.: 12321-34-00010, 12321-34-00040, 12321-34-00030, 12321-42-00090 Mailing address:P.O.Box 488, Belfair,WA Site address:24943 NE State Route 3,Belfair,WA Project: Portable asphalt plant Location of Meeting: Building III Planner: Rick Mraz EH: Pam Denton Building Plan Review 01/30/2003 02/05/2003 DONE DLC Applicant proposes a portable asphalt plant and possibly a 2000 gallon fuel tank.The question of whether a portable structure will require a permit was discussed.The applicant and his representative, Steve Johnson,was asked to prepare a proposal detailing specific information about set-up of the portable unit including how the structure(s)will remain portable,licensing,info,etc.It was recommended that they include photos and manufacturer specifications showing how the unit(s)would be supported during operations. A 2000 gallon fuel tank may be required for the operation.A building permit will be required, including a specific site plan showing location of all property lines,id all structures,driveways,and all other information specified in the Mason County Site Plan application form. The Washington State amendments to Uniform Building Code,chapter 29,specify that plumbing fixtures shall be provided as listed in table 29-A.The code also specifies that the plumbing fixtures shall be conveniently located in a building adjacent thereto on the same property.The applicant wished to install a portable toilet facility. I recommended that the proposal be included in the same proposal discussed above. When the proposal is received building staff,including the Fire Marshal will meet to discuss,and determine,building permit requirements. It was suggested that representatives from the Planning Dept. and Environmental Health Dept.also participate in the staff review. Application Received 01/30/2003 CMH Permit Fees Fee Type Amount Due Amount Paid No fees available for this case Total Fees:$0.00 $0.00 Amount Outstanding:$0.00 Conditions No conditions on this case hftp://www.co.mason.wa.us/permits/main.php?caseno=PAR2003-00008 1/9/2013 Aik (7) plc� Ct A d tout -- - A A _ -- - 6 MA) - - - i