EXISTING 5LD6
WO
-
z
PLANNING: Lu
ALL SETBACKS ARE MEASURED 7-
FROM THE FURTHEST to
j NEW PROJECTION OF THE BUILDING
STORAGE -
BLDG
m
1 to
pL G
i
4-10 A��� A8A
i
I �
I O
i
i
i
140'
450'
5 T A T E H IN Y 5 RECEIVED
CGENER& NOTE5 JUN 14 2017
. I. NOTIFY DE5IGNER/ARCHITECT/EN6INEER IF 51TE 615 W.Alder Street
CONDITIONS AND/OR BUILDING DEPT. REQUIRE ANY
MODIFICATIONS TO THESE PLANS PRIOR TO
COMMENCING WORK. 5I TE PLAN
2. CONTRACTOR TO CHECK 4 VERIFY ALL DIMENSIONS
I" = 30'-0"
BEFORE CONSTRUCTION.
5. MUST MEET OR EXCEED 2015 VENTILATION # ENERGY
CODES.
NOTES THIS 51TE PLAN 15 DRAWN BASED ON
DATA SUPPLIED BY CLIENT AND WITHOUT
BENEFIT OF SURVEY OR TOPOGRAPHY
I. THE CONTRACTOR SHALL COORDINATE 4 VERIFY
ALL ANCHOR BOLT 51ZE5 4 LOCATIONS WITH DEFERRED PLANS:
THE BUILDING MANUFACTURER.
2. THE BUILDING 4 FOUNDATION HAVE SEEN PLUMBING PERMITTING WILL BE
DEFERRED TO CONTRACTOR'S
DESIGNED PER THE 2015 UBG BIDDER DESIGN SUBMITTAL.
5. ALL CONCRETE SHALL HAVE A 25 DAY MEGHAN I GAL PERMITTING WILL DEFERRED TO GONTRAGTOR'S BE
COMPRESSIVE STRENTH F'c = 2500 P51 APPROVED BIDDER DE51ON SUBMITTAL.
Sr2 SACK MIX. MASON COUNTY DCD PLAN,,
ELEGTRIGAL PERMITTING WILL BE
4. ALL DEFORMED REINFORGINS STEEL SHALL SITE PLAN REQUIRED TO SE ON SI-, DEFERRED TO CONTRACTOR'S
BE A5TM A 615 GRADE 60 Fy = 60,000 P51 CHANGES SUBJEGT, TO APPROVAL BIDDER DESIGN SUBMITTAL.
By �71.1 , Crate 6
S. ALL WELDING TO BE DONE BY WABO CERTIFIED WELDERS.
6. PROVIDE (2) 2A 20BC FIRE EXIN6U15HER5 TO BE MOUNTED
NEAR THE EXIT DOORS IN CLEAR VIEW 4 REACH
1. PROVIDE A 516N ABOVE FRONT MAIN EXIT TO SAY
"THIS DOOR TO REMAIN UNLOCKED DURING BU51NE5 HOURS"
5. HEATING WILL BE PROVIDED BY SUSPENDED 6A5 UNIT HEATERS
AS PER MEGH CONTRACTOR. MAX TEMP 15 TO BE 50 DE6REE5.
9. SEE PLANS BY 'WEB STEEL OF WASHIN6TON, LLG'
FOR METAL BLD6 DETAILS