HomeMy WebLinkAboutBLD2013-00516 Cancelled Heat Pump - BLD Permit / Conditions - 3/13/2015 r I Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Shelton, WA 98584
irflo
MECHANICAL PERMIT BLD2013-00516
OWNER: AL CARSTENSEN RECEIVED: 7/1/2013
CONTRACTOR: LICENSE: EXP: ISSUED: 7/1/2013
SITE ADDRESS: 90 NE BEAR CREEK DEWATTO RD BELFAIR EXPIRES: 1/1/2014
PARCEL NUMBER: 123094190022
LEGAL DESCRIPTION: TR 2 OF NE SE &SE NE TR 2 OF SP#2479 AF#595284
PROJECT DESCRIPTION: DIRECTIONS T SITE.
DUCTLESS HEATPUMP
General IrIkormation Setback Information
Ty e of Use: SF Insp.Area: Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft.
Ty of Work: MEC Fire Dist.
Valuation: Side 1: Ft.
Side 2: Ft.
Mechanical Fixtures FEES
Type Q Type By Date Amount Receipt
Heat Pu p 1 Mechanical Base Fee TW 7/1/2013 $28.50 S220130000(
Mechanical Permit Fee TW 7/1/2013 $18.20 S220130000(
Total $46.70
BLD2013-00516 Please refer to the following pages for conditions of this permit. Page 1 of 3
4)- Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable
sections of the IRC and IMC.
Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems
are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for
inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal
ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or
rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in
accordance to WSEC Section 1411.
X t4 _
5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason Cou rdinances and building regulations.
9 9
X /� �
6) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prey�r�ted action from being taken. No more than one extension may be granted.
X �—F�-
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
P 9 p Y P P PP 9
occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate
and rants employees of Maso. Count access to the abo gibed property and structure for review and inspection.
9Y P P Y P
OWNER OR AGENT: DATE: 7
BLD2013-00516 Please refer to the following pages for conditions of this permit. Page 3 of 3
r CASE NOTES'rOR
BLD2013-00516
CONDITIONS FOR
BLD2013-00516
1 Contractor registration laws are governed under RCW 18.27 and enforced b the WA State Dept of Labor and Industries, Contractor Compliance
9 9 Y
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0 FThe person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) Owner/ ent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X�
3) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revoc t�ion.
X A(f,
BLD2013-00516 Please refer to the following pages for conditions of this permit. Page 2 of 3
o CONCRETE Gas Piping MANUFACTURED HOME y
o Interior-Date By _ __�_�.__ _____-_
w Footings/Setbacks ExterKx-Date 9y Ribbons Cn
Date By Ln INSULATION Date By Z
rn Foundation Walls BG/SLAB INSULATION Set-up M
Date By Date By Date By Z
FRAMING Floors FIRE DEPARTMENT r
Date By Date By
Dale By Walls
PLUMBING Date By DECKS
Da to e;
Groundwork vault TANKS
Date BY Date By
Date By Attic
p.W.V
Date By OTHER
Date By DRYWALL Type.
Date By
Water Line Date BY Type:
Date By Int.Brace Wall Date By W
ate By
CA MECHANICAL D�seperaaan FINAL INSPECTION o
Date By Date By Date By (4
O
° Pass or Request Inspect. a
CD Type of Insp. Fail Date Date Done By Comments
o a'
0
co
d
cn
CD
y �
O
n
O
7
_a
O
7
N
O
N
(D
3
v
v
co
m
0
' PERMIT NO. &D 51
MASON COUNTY 4-7
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360)427-9670•Belfair(360)275-4467•Elma(360)482-5269
On the web www.co.mason.wa.us
APPLICAt4T INFORMATION CONTRACTOR INFORMATION
Owner 1- Cc;'r�'r 51'0 Company Name
Mailino Address 90 ILE ea✓ G✓ce^ _Le1— 7- d Mailing Address
City. / - 'r State ALA Zip Code 9e.5 2-P City State Zip Code
Phone36a -275- 25&4 Other Ph. Phone Other Ph.
Lien/Title Holder Contractor Reg. # Exp.
E mail address E Mail Address
Drivers Lic.# DOB Drivers Lic.# DOB
SEPTIC INFORMATION - Connect to New Septic Existing Septic X Connect to Sewer System
Name of Sewer System
PARCEL INFORMATION- 12 Digit Parcel No. Fire District 2
Legal Description
Site Address(Please include street name, street number and city)X 90 &E.13ca v C/e'-x ,�N
Directions to site
Is property within 200' of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15%
TYPE OF JOB - New Add Alt Repair Other Use of Building
Location of Fixtures/Units- 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG_Natural Gas—Heat Pump_
Toilets Type of Unit No. of Units Fees
Bathroom Sirik Furnace
Bath Tubs HeatpumpsL>V4A- 3u
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets WBase
Kithen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust HoodHosebibs Dryer VentOther OtherBase Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
X Date
ROOF C21�C0��UATI/� WORK IS BY MEANS OF A PROGRESS INSPECTION.
Owner/Owners Representative/Contractor (indicate which one) /
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by: Planning Pd Ck# Date Bld Pd Receipt No.
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Occ Group-Type Constr.
Planning Department
Environmental Health Department
FEES
Plumbing& Base Fee Site Inspection
Mechanical & Base fee UFC Plan Review Fee
Wood/Gas/Pellet Stove Fee Other
Violation Fee TOTAL FEES