Loading...
HomeMy WebLinkAboutBLD2014-00725 Final Replacement SFR - BLD Permit / Conditions - 7/22/2015 Inspection Line (360)427-7262 Q,60"N COU•tTA MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 1854 RESIDENTIAL BUILDING PERMIT BLD2014-00725 OWNER: THOMAS ARNOLD RECEIVED: 8/8/2014 CONTRACTOR: FINE LINE CUSTOM CONST INC 360-275-0361 LICENSE: FINELLC938NT EXP: 12/6/2015 ISSUED: 10/27/2014 SITE ADDRESS: 2481 NE OLD BELFAIR HWY BELFAIR EXPIRES: 4/27/2015 PARCEL NUMBER: 123171400010 LEGAL DESCRIPTION: TR 1 OF SE NE & SW NW SEC 16 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE (REPLACEMENT) General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp. Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,450 Garage-Attached 361 Valuation: $ 177,060.64 Building Height: 21 Occ. Status: Primary Basement: COV DECK 96 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 140.0 Ft. Shoreline: Ft. Water Body: Union River Rear: W 120.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 50.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 220.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Bath Tubs 2 Dryer Vent 1 Plan Check Fee TW 8/8/2014 $922.58 S2201400000001 Clothes Washer 1 Exhaust Hood 1 Planning Review Fee TW 8/8/2014 $205.00 S220140000000i Dishwasher 1 Ventilation Fan 3 EH Minor Plan Review TW 8/8/2014 $ 100.00 S220140000000i Hosebibs 1 Building State Fee MAU 9/22/2014 $4.50 S120140000000i Kitchen Sink 1 Building Permit Fee MAU 9/22/2014 $ 1,430.55 S1201400000001 Lavatories 2 Mechanical Base Fee MAU 9/22/2014 $28.50 S1201400000001 Showers 2 Mechanical Permit Fee MAU 9/22/2014 $49.20 S1201400000001 Water Closets (Toilets) 2 Plumbing Base Fee MAU 9/22/2014 $24.70 S1201400000001 Water Heaters 1 Plumbing Permit Fee MAU 9/22/2014 $ 110.60 S1201400000001 Total $2,875.63 BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2014-00725 CONDITIONS FOR BLD2014-00725 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X } 2) Owner/Ault is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) Approved nsions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 4) All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X , 5) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent ters or wetlands. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X 6) Concrete ate and wash water must be contained during construction pouring, such that water quality degradation of adjacent waters does not occur. X 7) All property lines shall be clearly identified at the time of foundation inspection. X 8) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Appr 'te Plan" to ensure these structures are shown and meet the setback conditions listed. X 9) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure the es meet the setback conditions listed. X 10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not b ted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building D art nt for to any further inspections being performed or approvals granted. BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 2 of 5 11 THE FOU DATION SYSTEM SHALL BE PLACED ON UNDISTURBED I , FIRM-NATIVE SOIL. X 12) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building ment prior to any further inspections being performed or approvals granted. X b 13) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U-Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 5A 0.93 EFFICIENT WATER HEATER X 14) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in Y4 or sheets. The Mason Count Permit Center will also have some available. X 15) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404. X 16) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) X (�ED BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 3 of 5 17) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X 18) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 42� 117 19) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X 20) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in perms ation. X 21) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordina_ape or regulation, must be reviewed and approved by Mason County prior to construction. X C. �) _I--- 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspe s I be made prior to requesting additional inspections. X (�J4 23) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Ma my ordinances and building regulations. X c_J BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 4 of 5 24) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holde revented action from being taken. No more than one extension may be granted. X 1 n 25) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, coned flashing. Install metal connectors approved for contact with the new types of pressure treated material. X Gr 26) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. �ation drains within 30ft, down gradient of drainfield/reserve area. X 27) On-site septic system final installation approval required prior to temporary/final occupancy. SWG2014-00196 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERM PPLICATION 180 DAYS WILL INVALIDATE THE APPLICATION. � '9 av� Signature Date Je��s� ol� OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 5 of 5 ��6oN QD��rp MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 ,854 RESIDENTIAL BUILDING PERMIT BLD2014-00725 OWNER: THOMAS ARNOLD RECEIVED: 8/8/2014 CONTRACTOR: FINE LINE CUSTOM CONST INC 360-275-0361 LICENSE: FINELLC938NT EXP: 12/6/2015 ISSUED: 3/10/2015 SITE ADDRESS: 2481 NE OLD BELFAIR HWY BELFAIR EXPIRES: 9/10/2015 PARCEL NUMBER: 123171400010 LEGAL DESCRIPTION: TR 1 OF SE NE & SW NW SEC 16 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE (REPLACEMENT) General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,450 Garage-Attached 361 Valuation: $ 177,060.64 Building Height: 21 Occ. Status: Primary Basement: COV DECK 96 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 140.0 Ft. Shoreline: Ft. Water Body: Union River Rear: W 120.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 50.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 220.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Bath Tubs 2 Dryer Vent 1 Plan Check Fee TW 8/8/2014 $922.58 S2201400000001 Clothes Washer 1 Exhaust Hood 1 Planning Review Fee TW 8/8/2014 $205.00 S2201400000001 Dishwasher 1 Ventilation Fan 3 EH Minor Plan Review TW 8/8/2014 $ 100.00 S2201400000001 Hosebibs 1 Building State Fee MAU 9/22/2014 $4.50 S1201400000001 Kitchen Sink 1 Building Permit Fee MAU 9/22/2014 $ 1,430.55 S1201400000001 Lavatories 2 Mechanical Base Fee MAU 9/22/2014 $28.50 S1201400000001 Showers 2 Mechanical Permit Fee MAU 9/22/2014 $49.20 S1201400000001 Water Closets (Toilets) 2 Plumbing Base Fee MAU 9/22/2014 $24.70 S1201400000001 Plumbing Permit Fee MAU 9/22/2014 $ 110.60 S1201400000001 Water Heaters 1 Planning Dept. Permit Revi JBN 12/9/2014 $65.00 S2201500000001 Total $2,940.63 BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2014-00725 CONDITIONS FOR BLD2014-00725 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. x ' 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 1-2- 3) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. x ?2 Z= 4) All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 7 Z_ 5) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X _ 6) Concrete leachate and wash water must be contained during construction pouring, such that water quality degradation of adjacent waters does not occur. X 7) All property lines shall be clearly identified at the time of foundation inspection. X /�- 8) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Pla "to ensure these structures are shown and meet the setback conditions listed. X 9) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. x �J 10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior,j_o any further inspections being performed or approvals granted. BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 2 of 5 11) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X 12) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building De rior to any further inspections being performed or approvals granted. X 13) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 5A 0.93 EFFICIENT WATER HEATER X :T.7--- 14) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECCLWSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate"and are available in %or'/2 sheets. The Mason County Permit Center will also have some available. X 15) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. X 16) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) X BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 3 of 5 17) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X 18) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X *-3, 19) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions r rirrta`permit occur, or when one or more sleeping rooms are added or created. X 20) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupa y is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 21) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENTAND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prierto requesting additional inspections. X 23) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or t btain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinance building regulations. X BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 4 of 5 24) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have evente action from being taken. No more than one extension may be granted. X 25) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and ashing. Install metal connectors approved for contact with the new types of pressure treated material. X �� 26) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation in wn gradient of drainfield/reserve area. X -T 27) On-site septic system final installation approval required prior to temporary/ffnal occupancy. SWG2014-00196 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspende for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 0 YS WILL INVALIDATE THE APPLICATION. Signa ure Date l �� i."J ��� OWNER - REPRESENTATIV - RACTOR Print Name (Circle one to indi e) BLD2014-00725 Please refer to the following pages for conditions of this permit. Page 5 of 5 > CONCRETE MECHANICAL MANUFACTURED HOME X C) z 0 Footings I Setbacks GastePiping Da By Ribbons o Intenot Date By Interior-Date By Date ay r- 0 4 Exterior Date By Exterior-Date Bv Set-up Point Load I Isolated Footings INSULATIONBG I SLAB INSULATION Dale By ---------- 0 Date By Date By FIRE DEPARTMENT Foundation Walls Floors Date By 0 Date BY Data 4- By DECKS -F RAM I Wd Walls Date By Date By, Data 11 PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Date By Date By Type. Date By DV DRYWALL Type- T Date By Int Brace Wall Date By IA CD Date 3( r- W V11_5,- 13y FINAL INSPECTION 0 0 Water Line Fire Seperition IN3 CD @ Date By Date By Date -7 By. t�61 C) 81 1 7'Z I 1< 0 - 6 Pass or Request Inspect. Type of Insp. Fail Date Date Done By Comments -(D 4 0 C'el 6-tt, M04 ml,-, C �,.Oqe v A Wv k&vr, as gall- �YA� 0 C) 0 0• 0 (01 (A 0 -3tr sfjl�' Lot- A-de, A 0 LL b Pe, J_ 3 < vs- Vzzl Pr 1AL, A!sf 0 Pe4mit# 1_kOXMASON COUNTY BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 21-4 �'1 N i� Cld 14" j This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance : G f 1- N ,.. dti H ®m ire You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office 0 Make corrections, items will be checked on next inspection regarding possible structural a OK to damage incurred by recent "natural/man made" ❑Thisr is not a complete inspection disasters.This is NOTa Date 31/1 I ) S' Department (3 CORRECTION NOTICE. Inspector ffv�. * N T , `IEI V THIwj T _ kqu - .Permit# MASON COUNTY BUILDING 111426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 01() OeAg'`r H" This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance , v. tti !1 W A G, ✓t tti it-e.&4 L' -a-1 eAdvJ 6 "yl-r,% 1 " wil You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is NOT Date ,z�l�� Department I CORRECTION NOTICE. Inspector ��I�-- �� 4 N�L 4T P THP� T, , -* mw, Pcrn.it#J12V2Y--Qp?2-,5- MASON COUNTY BUILDING 111426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corre ted to gain compliance . i fs You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ please contact our office Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "naturallman made" ❑This is not a complete inspection disasters.This is NOT Date Department CORRECTION NOTICE. Inspector , /� l ,s* 0� f %,IT , r l�, z' A- ' TH/ x T, J*'' . .coU�T " MASON COUNTY PERMIT NO _ DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL 0072S WWW.CO.MASON.WA.US (360)427-9670 Shelton ext:352_. Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext.352 _ tau PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext. 352 BUILDING PERMIT APPLICATION 426 OWNER INFORMATION: CONTRACTOR INFORMATION: S T. NAME: tJC'L l5 _ /fJa was 4- T .+ NAME: t/4,fzi- 64,STI- MAILING ADDRE S: Fa do e MWi MAILING ADDRESS: i 5x- /8'03' CITY: & V- 'STATE:' I,jA 2IP:_,0Eay- CITY: 1411yAl STATE: i�-A- ZIP: ( PHONE: CELL: PHONE: ! �?75-�3E f CELL: e7 u EMAIL: EMAIL : f e/ b i,,, L&I REG#.r.ncLGG y3Ip,vT EXP./2 / G PARCEL INFORMATION:PARCEL NUMBER(12 DIGIT NUMBER) IZW ` 3 661 C)S Q FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): -rp z Sly N Sc f 7 SITE ADDRESS CITY DIRECTIONS TO SITE ADDRESS IS PROPERTY WITHIN 200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND ❑ WETLAND❑ SEASONAL RUNOFF ❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO TYPE OF JOB: NEW D( ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) &5 /���yGL IS USE: PRIMARY Y SEASONAL❑ NUMBER OF BEDROOMS ER OF BATHROOMS DESCRIBE WORK /V�'�/ S`y�o o .. �e /4,3v�,s G SQUARE FOOTAGE: I ST FLOORA✓SZ sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE z6'1 sq.fL ATTACHED❑ DETACHED❑ CARPORT sq.ft. ATTACHED ❑ DETACHED❑ MANUFACT D HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN MAKE MODEL YEAR LENGTH WIDTH DROOMS BATHS SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction w is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPFrG .I OF THJS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X ign o_A plicant Date X 45/2i.�,cJ Fff��it/ OWNER/ REPRESENTATIVE/ ONTRACT Print Na a (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL MASON COUNTY PERMIT NO. y ~ DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext.352 1854 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: 42Aje n K Inc'-,,se— NAME: /=7//�E C,„e 5Ti:ti, MAILING APpRESS: Po BL x f/ytl MAILING ADDRESS: PC 0c k /S'Z-7 CITY: 'Ll{ I t--✓ STATE: LvA ZIP: 9,rS2,r CITY:?q ' STATE: i,4.14 ZIP: /ems Y PHONE: CELL: ,I PHONE: ?f(, �, =V/ CELL: 5z*�-ileel EMAIL: EMAIL : L&I REG# Lf_c '�c-'i EXP•f Z/b / /S— PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): -,eeg;1,4 LEGAL DESCRIPTION(ABBREVIATED): 7,✓ inr _ Sr1-7 SITE ADDRESS: 2Jf&1 614/ Ts>✓ CITY: DIRECTIONS TO SITE ADDRESS: 61 el /3c%t„ .4" JF TYPE OF JOB NEW_ C�ADD ALT REPAIR OTHER USE OF BUILDING 5'F'- LOCATION OF FIXTURESAMTS-1ST FLOOR 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_ Toilets .-a-- Type of Unit No.of Units Fees Bathroom Sink Q Furnace c Bath Tubs Heatpump Showers Spot Vent Fan Water Heater = Propane Tank D Clothes Washer 1 Gas Outlets 0 Kitchen Sinks Wood/Gas/Pellet Stove r _ Dishwasher ( Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee 091'70 Base Fee S. 50 TOTAL PLUMBING 1/* TOTAL MECHANICAL _20-7a OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/applicabon becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 1 D YS WILL INVALIDATE THE APPLICATION. ��� X Signature f pplicant Da e Xi�?Nh`l'yi'�J1i� Owner/Owners Representative/ ntractor Print Name (indicate which one) --- DEPARTMENTAL REVIEW APPRUVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Request To Revise An Approved Plan Permit Number: BLDX 4_ ��S_ Name -se��4iNlf M rVJ Parcel Number /Z 3 17 -_Lq -Wo ( 0 Phone Number daytime (,ACQ Project Address ?kg( 6)b Rg, Iaw Mailing Address �)O Bolo fw23 Please provide a complete, detailed description of the proposed revisions to the approved plans: Moil a Neuc) c lSc ca-1 Are two sets of the revised plans or addendum indicating the changes included? !)i( Yes ❑ No Are the approved site plans included? ❑ Yes A No Are the revisions clearly and accurately identified on the plans or addendum? * Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes ?0 No If Yes, Has the engineer or architect approved this revision? ❑ Yes No Is a stamped and signed approval included with this request? ❑ Yes No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? Ii Yes ❑ No If Yes, Is a revised site plan, with all new setback dimensions included with this request? Yes ❑ No Additional Information: Applicant's signature — Date: 1716 Za/ Office Use Only Received by: Date Sent Assigned To Approved By Date Original Valuation: $ Additional Valuation: $ UH. 1 Sq.Ft. x$ $ tz(3 ► Sq.Ft. x $ $ KE Total New ValuationAdditional Fees: -- Additional Planning Dept. $ Additional Plan Review $ Additional Conditions/Com ents: Additional Building Permit $ Additional Plumbing $ Additional Mechanical $ Additional E. H. Dept. $ eA VT 0 — g�n'%aA �3:30�. ZUI� Other $ md- �,K ew. i s c�o+u�ed r �r aUcNP ��— Total Amount Due: $ Amount To Be Paid Up-Front$ d0i 0 32 4KP 205 j'a b7ree Dl mf hc1, we el/ RWW S��r2 w�TC� POW. APPROVED �3.s-` MASON COUNTY DCD PLANNI ,1 SITE PLAN REQUIRED TO BE ON SITE W CHANGES SUBJECT TO APPROVAL By _Date 1 Lf TOPOGRAPHY PROFILE: - Direction: Scale. Approval: for office use Building Permit number: _ ��-pl�- �� 72� I / - 60 Building: Owner/Applicant: A11JO L-D Date of Planning: I Parcel Number: /Z 3/7- /�— Qf_1r') /0 application: Env. Health: 3 s'z7 APPROVED MC PUBLIC HEALTH ALP �i�fN f7cGl> t d' S7v�rs` 33s- TOPOGRAPHY PROFILE: Building Permit number: �-A 2b1 - (X 72 — Direction: Scale:, Approval: for office�Se / — U Building: Owner/Applicant: N r L D �, /yiyarws bCG ' ` Y Date of Planning: application: Env. Health: Parcel Number: /Z 3/7- IV— M�2 10 A ��'��� Name Parcel# 2U BLD# r W L -r Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surfacez. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X I Width = Area *All dimensions in feet Buildings q 11 X 110 = O Z X C� _ ` L, Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Ddvewa s X = X = Length of drive begins at the right of way X = —Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property r r view and inspection as may be required. G r Owner/Agen Contractor one)Date: a�J If the I otal Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page I of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Mornmater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: httn//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE All The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in th kr ntirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:(360)-427-9670 EXT.450 Mail:P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT.352 Mail:P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St,Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for re "ew and inspection as may be required. X Owner/Agent/ A�®rle one)Date: 8 Page 2 of 2 MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECK`L-I/ST Owner's Name: Grn6ta Date: 8'e" Reviewed By: ry Documents: v Building Permit Application Completed X Stormwater Checklist Planning Intake Checklist Completed, Site plan includes:Allowable building area,roof overhangs,decks,etc. Fire Apparatus Access Road info required? Yes Energy Code Application Form-9 Electric wall eater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type_ } O Ductless Heat Pump O Other. Specify: X Mechatuca/PlumbE/LOCATIO Engineering? Ye 6 o Snow load. Seismic: D2_ Stock Plan—approved snow load: Seismic: _D2_ Manufactured Homes—4 OR PLANS ,Foundati ype: cture meth fo tion Basement DcYs'Covered? Uncovered over 4 x 6 an over 30"? Construction plans required. Construction Plans:)3 COMPLETE SETS _Plans Legibl _Recognized Scale _Elevation Views _Cross Section _Foundation Plan Roof Framing Plan _Floor Plan-Use of rooms noted(all floors) _Floor Framing Plan-all_floor levels including loft,crawlspace,etc. (Q00 S.F. ??—stairs?) —Deck Framing Plan,incl coy.porch framing Plan Details: rr Roof mina details,truss lay-out may be needed (Hip and girder location shown) Xt' Wall Framing-Does bearing-wall height excee 10'?(Engineering may be required) ZS Floor framing: Floor joists(size&spacing):m 2CA 500 0 ,Floor b ams: Window headers. Typical header._ *AS�4 p Garage heade � Wi �Z Foundation:footing size,reinforcement t Le,n Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required,see details) Landings at all exits?Less than 30"above grade?Y/N \�• Heated By Furnace-Location of Furnace Fuel type: X Fireplace/Stove Information Shown-Fuel Type? Location(s): Window Sizes Marked on Plans Braced wall panels(shear walls)marked on plans or lateral engineering? COMMENTS: ENGINEERING REQUIRED — Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the'engineered analysis shall be transferred onto proposed osed building plans. Wmd 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: ,Snow_psf. --- BREGULAR BUILDINGS R30I:2.22.2---- .._.. Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur. . 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6&beyond the braced wall line. 3)End of BWP extends more than 1 $.over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed_In accordance with accepted engineering practice. H:\permit tech building checklistdoc Revised 11-29-2007 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/Ventilation Code Compliance Application Submit with heating/cooling system size worksheet(see instructions #4) Ow er: Parcel#: Type of project: 6ri 2Y - Total Sq. fit. 1 Floor: 2" floor: _ Heated Basement: of heated area:: Heating System Type: 0 Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: % Prescriptive Option Table R402.1.1 Compliance Method µ Component Performance, R402.1.3 - Calculation worksheets required Check one:: µ Other (Specify): Check one R Whole House Ventilation system EL Whole House Ventilation µ Other, Ventilation using exhaust fans&window or Integrated with a Forced Air describe: System wall fresh air vents(M1507.3.4) System (M1507.3.5) Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/index.php. Additional Energy Ca)��escription: Small dwelling units with less than 1500 sq. feet of heated or cooled Efficiencyspace and less than 300 sq. ft fenestration (see ddemotion below) or additions to an Requirements existing building a Is ess than 750 sq. ft. of heated area. To use this option complete a window schedule in order to verify that the fenestration area does not Energy credits exceed 300 sq. ft. Fenestration is defined in the lECC as skylights, roof windows, required: vertical windows, opaque doors, glazed-doors that include products with glass and 05 non-glass glazing materials. -0.5 points Medium dwelling units not includes in a) above, or b) below- 1.5 points c) Large dwelling unit is a dwelling unit that exceeds 5000 sq. ft. of heated or cooled floor area. -2.5 points. Describe Energy Credit Option(s): Using Option number(s): S-(q- FENESTRATION SCHEDULE USE FOR ENERGY CREDIT, a) SMALL DWELLING OPTION&COMPONENT PERFORMANCE COMPLIANCE List all windows, doors, skylights. (If needed, attach an additional sheet) Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazin materials. Manufacturer Location U-Factor Size Quantity Total (rough opening) Square Feet o ? O yb G yo 3 Z 3 b ZU B 1 i i i 5 Total Fenestration: windows, skylights and door area