RESIDENTIAL BUILDING PERMIT BLD2011-00072
OWNER: KURT BYERLY RECEIVED: 1/28/2011
CONTRACTOR: LICENSE: EXP: ISSUED: 3/4/2011
SITE ADDRESS: 2750 NE OLD BELFAIR HWY BELFAIR EXPIRES: 9/4/2011
PARCEL NUMBER: 123165000010
LEGAL DESCRIPTION: ELLIS BANCROFT TRACTS TR 10 OF TRS 2-4
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
GARAGE/STORAGE NORTH FROM BELFAIR ON OLD BELFAIR HWY EAST SIDE OF ROAD TO
ADDRESS
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Y Lot Size: Deck:
Type of Work: ACC Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Garage-Detached 2,400
Valuation: Building Height: 26 Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: N 10.0 Ft. Shoreline: 143.0 Ft. Water Body: UNION RIVER
Rear: S 143.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: W 5.0 Ft. Shoreline Desig.: Conservancy
Year: Serial No.: Side 2: E 121.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee GMM 1/28/2011 $614.09 S12011000
Planning Review Fee GMM 1/28/2011 $205.00 S12011000
EH Plan Review SJC 1/28/2011 $103.00 S72011000
Building State Fee LDK 2/3/2011 $4.50 S12011bob
Building Permit Fee LDK 2/3/2011 $944.75 S12011000
Total $1,871.34
BLD2011-00072 Please referto the following pages for conditions of this permit. 1 of 5
CASE NOTES FOR
BLD2011-00072
CONDITIONS FOR
BLD2011-00072
1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Depa nt prior to any further inspections being performed or approvals granted.
X..
2) Owner gent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X -
3) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
X K C7
4) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
pern1hall be applied for, reviewed and approved prior to the change.
X
5) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X L1�
6) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Build1i Department prior to any further inspections being performed or approvals granted.
X r�
7) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85
MPH.
X �
8) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the
manufacturer's installation instructions.
X
BLD2011-00072 Please referto the following pages for conditions of this permit. 2 of 5
9) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
' Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X
10) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered.
A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations.
B. Septic tank(s) requires 5ft setback from all footing/foundations.
X. No foundation drains within 30ft, down gradient of drainfield/reserve area.
:�Z
11) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved.
X �
12) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
char &d�and shall be collected by the Building Department prior to any further inspections being performed or approvals granted.
X
13) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit;r ,vocation.
X �(
14) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X �
15) PlaceZme&f structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes.
X
BLD2011-00072 Please referto the following pages for conditions of this permit. 3 of 5
16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector s hall be made prior to requesting additional inspections.
�4
18) All property lines shall be clearly identified at the time of foundation inspection. X
19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X ��
20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X i</3
21) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X A;�/ )
22) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior
to construction of the retaining wall. X -�r fK
23) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
X 4
24) Landings and stairs must meet the same setback conditions as any permitted structure-, and, must be shown on your site plan. Please check your
"Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed.
X Kh
25) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X 3(2
BLD2011-00072 Please referto the following pages for conditions of this permit. 4 of 5
26) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. New garage will go
in locatignn close to Old Belfair Hwy and small garage structures will be demolished and removed.
X
27) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason
County Shoreline Master Program.
x 4�"3
28) This application is subject to Buffer and Landscaping requirements as required by approval MEP2010-00032 (buffer restoration and enhancements along
Union River).
x
29) All construction and demolition debris must be removed from the river area after project completion. Proper disposal of construction debris must be on
land in such a manner that debris cannot enter or cause water quality degradation of State waters. X �
30) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X 45
31) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing must be
installed and maintained until upland vegetation has become established. X !o
This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWN ER OR AGENT: DATE:
BLD2011-00072 Please referto the following pages for conditions of this permit. 5 of 5
y
CONCRETE MECHANICAL MANUFACTURED HOME
o Date By rn
Footings J Setbacks Gas Piping Ribbons X
o Interior Dater By Interior-Date By bate ay
!
N E.xterar Datf� By Exterior-Date B Set-
up
INSULATION C
Point Load Jlaolated Footings bate By
BG 1 SLAB INSULATION — - - ---- .{
Date By Data By FIRE DEPARTMENT
Foundation Walls Floors Date By
Date By Data By DECKS ---_..
FRAMING Walls Date By
Date By Data By PROPANE TANKS
PLUMBING vault bate By
Date By OTHER
Groundwork Attic
Date By Type-
Date By
D.W.v DRYWALL Type_
Int.Brace Wall Date By W
Date By Date By FINAL INSPECTION 0
v Water Line Fire Seperation N
Dale By Date By Dale Z BY
m
Pass or Request Inspect. c
Type of Insp. Fail Date Date Done By Comments o
o
o "
mCn
G /"
a _
c V,2-G /S6,
J
0
J
Building Permit # ) /—G�''�7� MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items Listed below must be corrected to gain code compliance
N v
T D c _ C o lr/ f�T L•/ 1� d�
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ This is not a compietd irfspection Dep ment C�
Date �' Inspector Z/7
moos 1: 04T Pi M44V T t T ' ,* m
FORM MUST BE COMPLETED IN INK
PLEASE PSHARD MASON COUNTY PROJECT SITE INFORMATION
Case No.
Name PARCEL NUMBER 1�/( -5O "Sq�_ pate
SHOW THE FOLLOWING ON SITE PLAN Show Direction by indieationg N, S, E, W in relation to the
site Klan
Lot Dimensions ---Fences �I
xisting Structures t,—Driveways
-Structure Setbacks "horelines
-- Water Lines _ ._.- Topography
ell Location�(including adjacent) —Drainage Plan
%_ Names of Streets -- /V�/�Easements
Names of Fronting Streets ✓Septic System
DRAW SITE PLAN BELOW Include adjacent properties if on shoreline or within 100 feet of adjacent property line.
adjacent p operty line
/ I
I
lapLi' Wf I
5 �V I ri
I
� I
C�iS'T;r•Iy yea.-.aj�� I` I
Tv 6 r
q0
r,s P PLANNING
3b,
APPROVOD
MASON COUNTY DCD:PLANNING
SITE PLAN REQUIRED TOCE ON SITE
CHANG S SUBJECT TO APPROVAL
adjacent property lined E-ad acent :ro ert line
Y ��C 1.
SAMPLE SITE PLAN
adjant property line> � _ E-adjacent.property line
v 30' r R� 3o-,I
seA_%n..,At- I a L
Norm 6 I .Gr�aLu Crz�K
F "Ara
I j oPastD s4++4C_ ----►1
I R I
VAGn,T
I G0.oPosCD
A&R=Z
I
�—B0 -- I
I
I I
� I
I \ i /DO
I � I r t;.e-LL
I
I I
I
I A /DD' _ � _ I
I
I
adjacent property line-;� ; a'• r \; Fadjacent pro pert' line
TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. if possible include height and the
degree of.slopes. See sample topography.profile.)
SAMPLE TOPOGRAPHY PROFILE
d�st�..cm fin
rµctt,a.Y�
a,zfi,rCe ro
dip
+o �
d
y�p10 � x .
SinnnturP ' Date
r 0 100,
Old Belfair
Highway
' Existing Union River
Type S Stream
Proposed 150' buffer+ 15'
Enhancement e building setback N
R 000 sq.ft.
Proposed ' 150'
garage(40'x
60') �— Proposed
estoration Zone
400 sq.ft.
130'
Proposed A P P V E D
buffer MASON COUNTY D PLANNING
Existing garage, reduction
covered area& SITE PLAN REQUIRED TO ON SITE
outbuilding to be CHANG S SUBJECT TO AP VAL
removed By Date 0 C-)let C
Me
�z 0 -Otqo?�7-
FIGURE 2. SITE MAP
Project Name: Parcel 123165000010 IMP
Location: Belfair,Washington
Project: TWC09-W326
Client: Kurt Byerly
THE WETLAND CORPS Date: 6/09
MASON COUNTY PERMIT NO.1- 2oI "=-7
BUILDING PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFORM A N CONTRACTOR INFORMATION
Owner E "Company Name
Mailin g Address A I E Z. Mailing Address
City tatel I A Zip Code qtR s-?_R City State Zip Code
Phon ' - Ot er Ph. Phone Other Ph.
Lien/Title Holder C/I Contractor Reg. # Exp.
E mail address 9 3 33 E Mail Address
Drivers Lic. # DOB Drivers Lic.# DOB
SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic 1/ES
Connect to Water System A[1A Name of Water System A4/F4
Well L-- - Sewer System Name of Sewer Syste
PARCEL INFORMATION - 12 Digit Parcel No. Fire District
Legal Description ��/ /0C/ 4
Site Address (Please include street name, street number and city) 6154 Brf&604t P-
Directions to site H D S t
Will timber be cut and sold in parcel preparation?Yes/
Is property within 200'of Saltwater ^/VG Lake ,Af D River/Creek- Y15--5 Pond&6
Wetland AIl1 Seasonal Runoff IV& Stream Slopes or Bluffs --' 15% Al
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No ;
TYPE OF JOB --New �- A Alt Repair Other PRIMARY RESIDENCE E] SEASONAL ❑
Use of Building �i scribe Work ��4 plc+
No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor
3rd Floor Basement Deck Covered Deck Other Sq. ft.
Garage L=" Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price$ Replacement Unit? Yes/ No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all
the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work
proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or
agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY
MEANS OFXPROGRESS SPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF1 DDAYS ILL INVALIDATE THE APPLICATION.
i
X Date: 39 a O
Owner/Owners presentative/Contractor (indicate which one)
1
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department AIP 5C'
Planning Department
-(5eg` M y:, al00 �� fp
Environmental Health Department
Fire Marshal
FEES
Building Permit Fee Site Ins ection
Plan Review Fee EH Review Fee
Plumbing & Base Fee Planning Review Fee
Mechanical & Base fee Other
Wood/Gas/ Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES
cMASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST
Owner's Name: ! 41 Date: -cP- -/ Reviewed By:
Documents: J
�'- Building Permit Application Completed Stormwater Checklist ��
�lanning Intake Checklist Completed,
Site plan includes:Allowable building area,roof overhangs,decks,etc.
_Fire Apparatus Access Road info required? Yes/No
_Energy Code Application Form- O Electric wall heater O Electric central furnace O LPG Furnace
O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) '
O Other: Specify:
_Mechanical/Plumbing Application-WATER HEATER FUEL TYPEILOCATION
-'Nt_Engineering? es No Snow load:Ig f5 Seismic: '-
Stock Plan-approved snow load: Seismic:
Manu acture es-4 FLOOR PLANS
FXr ion Type: ANSI/Manufacture method Engineered footing/foundation Basement
iDecks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required.
Construction Plans:_3 COMPLETE SETS //11
Plans Legible V Recognized Scale �ftq
E)levation Views Vross Section
ISFounda ion Plan ( oof Framing Plan loor Plan- Use of rooms noted(all floors)
loor Framing Plan-all oor levels including to ,crawlspace,etc. (<200 S.F. ??-stairs?)
Deck Framing Plan, incl cov. porch framing
Plan Details:
V oof framing details,truss lay-out may be needed (Hip and girder location shown)
Wall Framing-Does bearing-wall height exceed 10'?(Engineering may be required)
loor framing: Floor joists(size&spacing): , Floor beams:
Window headers. Typical header:
-_Foundation: footing size, reinforcement
Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required, see details)
Landings at all exits?Less than 30"above grade?Y/N
Heated By Furnace-Location of Furnace Fuel type:
Fireplace/Stove Information Shown-Fuel Type? Location(s):
Window Sizes Marked on Plans
Braced wall panels(shear walls)marked on plans or lateral engineering?
— 2-story garage? (Engineering may be required) IS'story of two story D1 -45%,D2-55%
COMMENTS: no- 1 f itU au ci �-P-4+Q-y �u' ►'' 2-cog
ENGINEERING REQUIRED
Braced wall panels/brace wall lines are not marked on plans(R602.10)
Amount and location of bracing does not meet minimum required in Table R602.10.1
DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed
building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: Snow___psf.
IRREGULAR BUILDINGS R301.2.2.2.2
Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be
considered to be irregular when one or more of the following conditions occur:
1)Exterior braced wall line or BWP cantilevered or offset by more than 4'
2) Roof or floor is not laterally supported on all edges
2A) Portion of roof or floor extend more than 6 ft.beyond the braced wall line.
3) End of BWP extends more than 1 ft. over an opening more than 8 ft in width below.
4)Opening in a floor or roof exceed the lesser of 12 ft. or 50%of the least floor or roof dimension.
5)Portions of floor level are offset vertically
6) Shear wall lines do not occur in two perpendicular directions.
7) When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys, and veneer).
When this applies the entire story shall be designed. In accordance with accepted engineering practice.
H:lpermit tech building checklist.doc Revised 11-29-2007
Nam r% Parcel#la /65;-1,000/1_ BLD# no/ 49(L0 7 2.
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area * All dimensions in feet
Buildings ' X _
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
Any paved, gravel or packed area per definition
X — above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas) a 60
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name Parcel# BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to "Title 14, Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document
entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT. 450
Mail: P 0 Box 1850, Shelton WA 98584
Physical: 415 N 6th St, Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other, parcel. You may also wish to consult with the septic design professional involved with the project. Mason
County Division of Environmental Health can be reached at:
Phone: (360)-427-9670 EXT. 352
Mail: P 0 Box 1666, Shelton WA 98584
Physical: 426 W Cedar St, Shelton WA 98584
A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date: /
Page 2 of 2
yoN-STAT�O� MASON COUNTY
�P C DEPARTMENT OF COMMUNITY DEVELOPMENT
O A 0 V1
S N Z Planning Division
7 N Y ti P O Box 279, Shelton, WA 98584
(360)427-9670
1864
NOTIFICATION OF COMPLETENESS
Jul 2-1 t 2uoq
KURT BYERLY
2750 NE OLD BELFAIR HWY
BELFAIR WA 98528
Parcel No.: 123165000010
Project Description: CONSTRUCT 40X60 GARAGE WITH A REGULATED STREAM BUFFER
THAT ENCOMPASSES THE MAJORITY OF THE PROPERTY THAT IS
SUITABLE FOR BUILD
Dear Applicant:
You have submitted a permit application (case no. MEP2009-00046) for proposed construction or
development in the county. Upon review of your application, I have determined that the
application is complete for the purposes of beginning the permit review. This review is pursuant
to Mason County Code, Title 15 (Mason County Development Code.)
will proceed with the review process of your permit application; however, additional information
may be required by another department at a later date.
Please call me at (360)427-9670, ext. 365 if you have any questions.
Sincerely,
C�G2�
Allan Borden
Land Use Planner
Mason County Planning Department
Comments:
Application and habitat management plan received; will discuss timing of public hearing to review
proposal. AHB
Page 1 of 1 MEP2009-00046
l ,
1
MASON COUNTY - Mason County Permit Center,Use:
DEPARTMENT OF COMMUNITY DEVELOPMENT DDR 201 , OW 10
411 N. Fifth Street/P.O. Box 186, Shelton WA 98584
360.427.9670 ext. 352 Date Rcvd
Request for
Administrative Variance for Reduction in the Required Setbacks ($115.00)
For administrative review, the minimum variance on a setback request is 5 feet from the side yard lot
lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction
requires a standard variance. Setbacks are measured from the furthest projection of the structure,
including roof eaves. /
Applicant/Owners: �l
Mailing Address: ,2 7 SO 1 L- , vV 13Y 14,
City: ��j f/ � State: Zip: 9 k 2 8-
Telephone: 366 Br333
Email: z ti e�lu.G�Gy�t� r -.o9tlY,Cz�01
If this reduction is tied to a building permit, please give permit case number.
BLDe 1�9-0/1-000
Parcel Number(s): /a 3 /1'5`010_1�4 O/U Zoning s
Site Address: a 7 5-6 -t/ z U/
W br1 ""I
Requested setback variance:
ft. a_`V ont ❑ Rear ❑ Side
J� ft ❑ Front ❑ Rear l5'Side
ft. ❑ Front ❑ Rear ❑ Side
ft ❑ Front ❑ Rear ❑ Side
Front Setbacks—From access easements and road right of ways. Minimum 10 feet.
Rear Setbacks—From the rear property line. Minimum 10 feet.
Side Setbacks—From the side property line. Minimum 5 feet except for certain shoreline designations.
An illustrated site plan is required.
Your site plan must show the following: north arrow, abutting street or easements, set backs to all
property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and
driveway. Show all proposed new development.
1ACommunity DevelopmentTAMARIANCESWdmin Variance.doc Edited on 7/
FRONT AND OR REAR YARD REDUCTION REQUESTS:
For existing lots of record as of March 5, 2002;
You must meet one of the following:
2) One of the following exists on the lot (check all that apply):
a a) steep slopes, wetlands, or streams present;
❑ b) soils that restrict building or septic development;
❑ c) lot width at the front yard line of no more than 50 feet;
❑ d) lot size of no more than one-fourth acre;
e) existing improvements of buildings, septic systems, and well areas.
SIDE YARD REDUCTION REQUESTS:
For existing lots of record as of March 5, 2002;
You must meet one of the following:
2) Onep_f the following exists on the lot (check all that apply):
a) steep slopes, wetlands, or streams present;
❑ b) soils that restrict building or septic development;
❑ c) lot width at the front yard line of no more than 50 feet;
❑ d) lot size of no more than one-half acre;
C3 e� existing improvements of buildings, septic systems, and well areas.
Explain how these circumstances preclude a reasonable development proposal from meeting the
setback standard for Rural Residential 2.5, 5, 10, or 20 zones.
5 Z �icwi o 6utyit�zs ..,
�S fV4 wvin SO T n-e /O/, 5-eft r4ct />rs-r 5ce i Jf5 14 Y
Own r/Agent ( lease indicate) �— 1/
Signatur D A
Official Use Only
Approved : Date
Pp b Y
Denied by: Date
Reason for denial:
IACommunity Development\PAC\VARIANCES\Admin Variance.doc Edited on 7/