HomeMy WebLinkAboutBLD2014-00739 Heatpump Final - BLD Permit / Conditions - 9/5/2014 * Inspection Line (S%U)421-/ZbZ
• MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Shelton, WA 98584
MECHANICAL PERMIT BLD2014-00739
OWNER: JERRY LIND RECEIVED: 8/12/2014
CONTRACTOR: SCOTT HOMES, INC. 360-357-9167 LICENSE: EXP: ISSUED: 8/12/2014
SITE ADDRESS: 5630 E STATE ROUTE 302 BELFAIR EXPIRES: 2/12/2015
PARCEL NUMBER:_ 122335000020
LEGAL DESCRIPTION!OLYMPIC SHORE TR'trW1/2 OF &T.L.
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DUCTLESS HEAT PUMP
General Information Setback Information
Front: Ft. Shoreline: Ft.
Type of Use: SF Insp.Area:
Rear: Ft. Slope: Ft.
Type of Work: MEC Fire Dist.: 2
Side 1: Ft.
Valuation:
Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Heat Pump 1 Mechanical Permit Fee TW 8/12/2014 $18.20 S220140000(
Mechanical Base Fee TW 8/12/2014 $28.50 S220140000(
Final Inspection Fee TW 8/12/2014 $73.00 S220140000(
Total $119.70
BLD2014-00739 Please refer to the following pages for conditions of this permit. Page 1 of 3
CASE NOTES FOR
BLD2014-00739
CONDITIONS FOR
BLD2014-00739
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-8006�0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X l�
3) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and
approved by Washington State Labor& Industries must be available on-site during the inspection.
The Mason County Building Inspector will inspect the following:
Verify that the system is installed in accordance with manufacturer specifications;
The inspector will check to make sure that the exterior unit is permanently installed and supported,
the exterior unit complies with required setbacks to property lines,
fuel tanks are located at least 10-ft from the system, a source of ignition,
all exterior penetrations are properly sealed,
condensate lines are installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location
outside of the foundation,
copper refrigerant lines are insulated with '/z" thick continuous closed-cell foam insulation or better,
indoor units are located at least 3-ft from smoke and carbon monoxide alarms,
and that modifications made to the structure, to install the unit, does not affect existing structural members.
X
4) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC
Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances),
repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created.
X )1/
BLD2014-00739 Please refer to the following pages for conditions of this permit. Page 2 of 3
All construction must meet or exceed all local ordinances and the internauonai coaes requirements as auupteu anu anienueu uy ividauii %..uuirty duu uia
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit rev!pn.X '
6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector II be made prior to requesting additional inspections.
X
7) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason CA ty ordinances and building regulations.
X 9
8) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder ha v prevented action from being taken. No more than one extension may be granted.
X
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permitlapplication becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
Signature Date
`7LV'C otL ,_ f OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate)
BLD2014-00739 Please refer to the following pages for conditions of this permit. Page 3 of 3
o CONCRETE Gas Pi ifltHflOf-Dr-D ate MANUFACTURED HOME
� By 1—
v
Footings!Setbacks F.Aeriot-Date By Ribbons
C—
c date By INSULATION Date 8y X
(D Foundation Walls BG I SLAB INSULATION Set-up
Date By Date By Date BY
FRAMING Floors FIRE DEPARTMENT
Date By Date By
Date By Walls DECKS
PLUMBING Date SY
Date By
Groundwork Vault TANKS
Date By Date By
Date By ,Attic
D.W.V
Date By OTHER
Date By DRYWALL Type:
Da to BY
Water Line Data By Type:
Date By Int.Brace Wall Date By W
r
v MECHANICAL Date FINAL INSPECTION
m Fire Seperation O_
CD Date By Date By Date c;t �-
O
° Pass or Request Inspect. O
oType of Insp. Fail Date Date Done By Comments
v
0
0
y
0
rr
y
(D
1
3
0
ti