HomeMy WebLinkAboutBLD2015-00959 Beach Stairs - BLD Application - 11/11/2015 MASON COUNTY Permit No U 20 1 J 0�
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING•PLANNING•FIRE MARSHAL (360)427-9670 Shelton ext.352
__ htto•//www co mason wa.us/community dev/ (360)275-4467 B �ED
4 3uy 426 W Cedar Street,Shelton WA 98584 (360)492-5269 a J
�}�?n -
,�,,. BUILDING PERMIT APPLICATION NOV 1 12015
Q p PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: 426 W. CE AR ST
J NAME:C�Fa.r /ihc���-SYn NAME:
MAM!!�ADREscs: /053o W Ec Azt-,00d-iDr- MAILING ADDRESS:
CITY: STATE: A ZIP: 535-1 CITY: STATE: ZIP:
PHONE:, hA CELL:2S3-318-7qS°u PHONE: CELL:
M EMAB.: EIvIAIL:
W L&I REG# EXP.
CONTACT: OWNER❑ CONTRACTOR❑ BELOW❑
NAME: r�;a �nldwln ,Vlcst�vnd GflG r1PlLI.�AILINGADDRESS: 9/7 5W �/, -,Ay / -
C1TY: oar+ (shard- STATE: WA ZIP."'MV(, PHONE:36n-e-?6-3770 CELL:36o-31�-679'F
EMAIL: CM 1 ern Grim
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER) Z Z 3 3 -SO- D 0/Z FIRE DISTRICT
LEGAL DESCRIPTION(ABBREVIATED): Oq t- t Poo Lo+ 1 Se 3 2 ) K
SITE ADDRESS S it o,�� 3 oZ- CITY Qt i-
DIREC�TONS TO SITE ADDRESS Ec s on 5 3 aZ }D cr—[y,,,,i, I: _ S a Y,
�2
t sloe o
IS PROPERTY W ITBIN 200 FT:
SALTWATER LAKE Q RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YESIK NO❑
TYPE OF JOB: NEW ❑ ADDITION ❑ ALTERATION Q REPAIR❑ OTHER,g
USE OF STRUCTURE(RESroENCE,GARAGE=) �J�e-
IS USE: PRIMARY❑_ �SEA�ONA� ❑ OZOQMSIIf�NUMBER OF BATHROOMS
DESCRIBE WORK
SOUARE FOOTAGE:
1STFLOOR FLOOR �E]
OR sq.& BASEMENT sq.fL
DECK COVERED DECK sRAGE sq.fL OTHER sq.ft
GARAGE sq.ft ATTACHID❑ DETACHARPORT ATTACHED❑ DETA ❑
MANiTI A OME INFORMATION: PIES OF THE FLOOR PLAN RE
MODEL YEAR LENGTH
TH BEDROOMS BATHS SERIAL NUMBER
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that i am the owner or owner's legal representative.I further
declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the
necessary parties,including any easement holder or parties of interest regarding this projecL The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure(s)for review and inspection.This permit/application becomes null&void if
work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. `-`-
PROOF OF CO NliAWORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT
APPLICA O OF AYS WILL CAUSE THE APPLICATION TO BE EXPIRE .(MASON COUNTY CODE 14.08.42)
Si O ER Dat
AL -W AMOVE DATE DENIED DATE GS/NOTFS/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL I'lD E l(✓
BUILDING PERMIT FEE FIRE ACCESS AND GRADE
PLAN REVIEW GEO-TECH REVIEW
PLUMBING&BASE FEE STORMWATER REVIEW
MECHANICAL&BASE FEE TOTAL FEES
WOOD/GAS/PELLET STOVE VIOLATION INVESTIGATION FEE
PLANNING REVIEW FEE VIOLATION FEE
n�iL f�N Y Ti�.i- 1 '�. •�2,,�?-5L'
a F =,�r'�..,.: .... .. ;. :.;i�;s���i`h,...
MASON COUNTY RESIDENTLAL, PLANTS SUBMITTAL CHECKLIST
Ovmer's Nome: f'1G Date: 1 1-1 1.20!S Reviewed By. U-,�
$uildmg Permit Application Complete Stormwater Checklist
;/ lanning Intake Checklist Completed U I L D I N G
V Site plan includes:Allowable building area,roof overhangs,decks,etc.
ran, Access Access Road info required? Yes/No
ode Application Form-O Electric wall heater O Electric central furnace O LPG Furnace
O Heat pump with electric furnace O Heat p wa LPG firna.ce O Boiler(heat type R V CJp in ZZ;]A
O Ductless Heat Pump 0 Other. Specify: �` S`�t�—f-e-
�_ nicaUP ing Application-WATER TER F IJEL�D2'A-
OCATION
1✓Enginee Ye o Snow load: Seismi NOV 2015
Stock Plan-approved snow load: Seismic: D2_ 426 W. CEDAR ST.
Nanui'actured Ho -=1 FLOOR PI-ANS
oundation Type: ufacture method Engineered footing/foundation Bar went
Decks: Covered? Uncove r 4 x 6 and over 30"? Construction plans r ed.
Constructio c PZans: ✓3 COMPLETE SETS
Mans Legs-ble _Recognized Scale _Elevation Views _Cross Section
_Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors)
Flo lan- oor le loft, crawlspace,etc. (Q00 SF. ??-stairs?)
Deck Framing Plan, incl cov.porch framing
Plan Deta .
-_R55T fi+aming details,truss lay-out may be needed (Hip and girder location shown)
Wat Framing-Does bearing-wall height ex ed 10'? (Engineering maybe required)
Floor framing: Floor joists(size&spacingLP �X ID JD IS�,Floor beams: 14 V I A
---VFmdow headers. Typical header. Garage header.
---Fommdation:footing size,reinforcement
concrete Walls-Does Concrete Wall Height Exceed 8'? (Engineering may be required, see details)
wings at all exits?Less than 30"above grade?Y/N
mated By Furnace-Location of Furnace Fuel type:
=-replace/Stove Information Shown-Fuel Tvpe? Location(s):
dow Sizes Marked on Plans
-=-�racLd wall panels (shear walls)marked on plans or lateral engineering?
COMIYENTS:
En P ao f5•ccn q4 - A+F S+ctn s - z) b-ca-c.k___,
ENGIRTFERING REQU-=
Braced wall panels/brace wall lines are not marked on plans(R602.10)
Amount and location of bracing does not meet minim=required in Table R602.10.1
DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed
building plans. Wind 85 MPH, Exposure B (unless proven othm e). Seismic Zone: ,Snow gsf.
IRREGULAR BUILDINGS R3012222
Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be
considered to be irregular when one or more of the following conditions occur:
1)Exterior braced wall line or B WP cantilevered or offset by more than 4'
2)Roof or floor is not laterally supported on all edges
2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line.
3)End of BWP extends more than 1 ft over an opening more than 8 ft in width below.
4) Opening in a floor or roof exceed the lesser of 12 ft. or 50%of the least floor or roof dimension.
5)Portions of floor level are offset vei-dcally
6) Shear wall lines do not occur in two perpendicular directions.
7)When a story above grade is includes masonry or concrete construction(exc: fireplaces, chimneys, and veneer).
When this applies the entire story shall be designed.In accordance with accepted engineering practice.
'permit tech building checklistdoc Revised 11-29-2007
x�-I/"�7
Letter of Agreement
1. This Letter of Agreement, "LOA"is for the use by the new owner of that
certain real property, commonly known as 5772 State Route 302, Belfair, WA 98528,to
certify to Mason County Planning,that Owner will fully comply with all conditions
contained in the Habitat Management Plan, "HMP", dated August, 2015,by Kim
Schaumburg, BioResources, LLC, and the Decision of the Mason County Hearing
Examiner, Phil Olbrechts, dated November 12, 2015.
2. We/I the Owners agree to comply with the conditions of the said Decision,the
HMP, a true and accurate copy of both of which are hereto attached, and be subject to the
County's code enforcement process for failure to comply with the conditions therein
contained.
3. We/I the Owner(s)make this LOA with Mason County to certify that this
condition will apply to us/me after conveyance of the said realty to us/me by Cheryl
Ancich-Smith and Chalene V. Wilson.
4. Specifically,we/I agree to maintain the area as called forth therein by removal
of invasive species, should the same intrude, and replacement of any of the trees or
shrubs as planted in accordance with the HMP, as the same may fail or die.
Mason C Planning Owner
eb cca hersha Print Name
Print Name
TO BE KEPT IN THE
PARCCL FILE
Letter of Agreement
1. This Letter of Agreement,"LOA"is for the use by the new owner of that
certain real property,commonly known as 5772 State Route 302,.Belfair,WA 98528,to
certify to Mason County Planning,that Owner will fully comply with all conditions
contained in the Habitat Management Plan, "HMP",dated August,2015,'by Kim
Schaumburg,BioResources,LLC,and the Decision of the Mason County Hearing
Examiner,.Phil Olbrechts,dated November 12,2015.
2. We/I the Owners agree to comply with the conditions of the said Decision,the
HIVIP, a true and accurate copy of both of which are hereto attached, and be subject to the
County's code enforcement process for failure to comply with the conditions therein
contained.
3.We/I the Owner(s)mare this LOA.with Mason County to certify that.this
condition will apply to us/me after conveyance of the said realty to us/me by Cheryl
Ancich-Smith and Chalene V. Wilson.
4. Specifically,we./I agree to maintain the area.as called forth therein by removal
of invasive species, should the same intrude,and replacement of any of the trees or
shrubs as planted in accordance with the HMP, as the same may fail or die.
Mason C Planning Owner
Ke_b&&atfersha am
P Name
b/L4/LU 1 b
Conditions Associated With 2:52:03PM
Case #: BLD2015-00959
1�
Permit Condition Status Updated
item# Code Title Status Changed By Tag By
1) 1000 PLANNING CONDITIONS NOT MET 11/20/2015 RDH
A.The mitigation detailed in the Habitat Management Plan prepared by BioResources,dated August 2015 shall
be completed during the Fall/Winter of this year(2015/2016).
X
B. Upon sale of the property(upland of tidelands),the"Letter of Agreement"shall be signed by the purchaser
of the property.
X
C.The stairway will be removed if the WA Department of Ecology does not grant final approval of the
Conditional Use Permit(SHR2015-00008)by January 17th,2016.
X
2) 200 SITE PLAN NOT MET 11/19/2015 CRE
Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest
projection of the structure.
X
3) 700 RCW 18.27 NOT MET 11/19/2015 CRE
Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and
Industries,Contractor Compliance Division.There are potential risks and monetary liabilities to the
homeowner for using an unregistered contractor.Further information can be obtained at 1-800-647-0982.The
person signing this condition is either the homeowner,agent for the owner or a registered contractor according
to WA state law. X
4) 1001 PLANS REQUIRED ON SITE NOT MET 11/19/2015 CRE
All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans
are not available on site,then approval will not be granted. In addition,a re-inspection fee(refer to current fee
schedule,minimum 1 hour)will be charged and must be collected by the Building Department prior to any
further inspections being performed or approvals granted.
X
5) 1002 ADDRESS/ROAD SIGNING NOT MET 11/19/2015 CRE
Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in
accordance with Mason County Title 14.28.
X
6) 1003 PLAN REVIEW CORRECTIONS NOT MET 11/19/2015 CRE
The plan review check list and corrections are part of the approved plans and must remain thereto. It is the
responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The
permit holder is responsible to retain the complete approved set of plans on site for the duration of the project.
Failure to comply and/or removal of approved documents will result in failure of required building inspections.
X
7) 1012 SITE PLAN REQUIRED ON SITE NOT MET 11/19/2015 CRE
The "approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the
"approved" site plan is not on site,then approval will not be granted. In addition,a re-inspection fee(refer to
current fee schedule,minimum 1 hour)will be charged and shall be collected by the Building Department prior
to any further inspections being performed or approvals granted.
X
8) 5003 ALL CONSTRUCTION NOT MET 11/19/2015 CRE
All construction must meet or exceed all local ordinances and the international codes requirements as adopted
Page 1 of 2 CaseConditions..rpt
6/24/2016
Conditions Associated With 2:52:03PM
Case #: BLD2015-00959
i�
and amended by Mason County and the State of Washington. Occupancy is limited to the approved and
permitted classification. Any non-approved change of use or occupancy would result in permit revocation.
X
9) 5025 SETBACK REQUIREMENTS NOT MET 11/19/2015 CRE
Proposed structure(s)must maintain a minimum of a 5'setback from all property lines,easements and 25'from
all County and State Road right of ways.Setbacks are measured from the furthest projection of the structure.
X
10) 5026 Structure Setback NOT MET 11/19/2015 CRE
Proposed structure or portions thereof,must maintain a 5'separation distance between adjacent structures and
that furthest projection.X
11) 5030 CHANGES TO APPROVED PLANS NOT MET 11/19/2015 CRE
All changes to"approved"building plans that effect compliance with the international codes as amended and
adopted,or any other Mason County ordinance or regulation,must be reviewed and approved by Mason
County prior to construction.
X
12) 5045 FIELD CORRECT NOT MET 11/19/2015 CRE
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY
BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department.
All construction must be in conformance with the international codes as amended and adopted by Mason
County. Any corrections,changes or alterations required by a Mason County Building Inspector shall be made
prior to requesting additional inspections.
X
13) 5600 FINAL INSPECTION REQUIRED NOT MET 11/19/2015 CRE
All building permits shall have a final inspection performed and approved by the Mason County Building
Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be
documented in the legal property records on file with Mason County as being non-compliant with Mason
County ordinances and building regulations.
X
14) 5700 PRESSURE TREATED LUMBER NOT MET 11/19/2015 CRE
Pressure treated wood manufactured after January 1,2004 may contain high concentrations of copper which
could quickly corrode metal fasteners,connectors,and flashing. Install metal connectors approved for contact
with the new types of pressure treated material.X
15) 6550 LANDINGS AND STAIRS NOT MET 11/19/2015 CRE
Landings and stairs must meet the same setback conditions as any permitted structure;and,must be shown on
your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the
setback conditions listed.
X
Page 2 of 2 casacon"Ons..T%
6/24/2016
Conditions Associated With Am 2:52:03PM
Ir Case #: BLD2015-00959
pro
Permit Condition Status Updated
item# Code Title Status Changed Bye, Tag Date
1) 1000 PLANNING CONDITIONS NOT MET 11/20/2015 RDH
A.The mitigation detailed in the Habitat Management Plan prepared by BioResources,dated August 2015 shall
be completed during the Fall/Winter of this year(2015/2016).
X
B. Upon sale of the property(upland of tidelands),the "Letter of Agreement" shall be signed by the purchas
of the property.
X
C.The stairway will be removed if the WA Department of Ecology does not grant fmal approval of the
Conditional Use Permit(SHR2015-00008)by January 17th,2016.
X
2) 200 SITE PLAN NOT MET 11/19/2015 CRE
Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest
projection of the structure.
X
3) 700 RCW 18.27 NOT MET 11/19/2015 CRE
Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and
Industries,Contractor Compliance Division.There are potential risks and monetary liabilities to the
homeowner for using an unregistered contractor.Further information can be obtained at 1-800-647-0982.The
person signing this condition is either the homeowner,agent for the owner or a registered contractor according
to WA state law. X
4) 1001 PLANS REQUIRED ON SITE NOT MET 11/19/2015 CRE
All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans
are not available on site,then approval will not be granted. In addition,a re-inspection fee(refer to current fee
schedule,minimum 1 hour)will be charged and must be collected by the Building Department prior to any
further inspections being performed or approvals granted.
X
5) 1002 ADDRESS/ROAD SIGNING NOT MET 11/19/2015 CRE
Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in
accordance with Mason County Title 14.28.
X
6) 1003 PLAN REVIEW CORRECTIONS NOT MET 11/19/2015 CRE
The plan review check list and corrections are part of the approved plans and must remain thereto. It is the
responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The
permit holder is responsible to retain the complete approved set of plans on site for the duration of the project.
Failure to comply and/or removal of approved documents will result in failure of required building inspections.
X
7) 1012 SITE PLAN REQUIRED ON SITE NOT MET 11/19/2015 CRE
The "approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the
"approved"site plan is not on site,then approval will not be granted. In addition,a re-inspection fee(refer to
current fee schedule,minimum 1 hour)will be charged and shall be collected by the Building Department prior
to any further inspections being performed or approvals granted.
X
8) 5003 ALL CONSTRUCTION NOT MET 11/19/2015 CRE
All construction must meet or exceed all local ordinances and the international codes requirements as adopted
Page 1 of 2 CaseConditions..rpt
6J24/2016
Conditions Associated With 2:52:03PM
Case#: BLD2015-00959
P10
Permit Condition Status Updated
item# Code "Title Status Changed By Tag Date By
and amended by Mason County and the State of Washington. Occupancy is limited to the approved and
permitted classification. Any non-approved change of use or occupancy would result in permit revocation.
X
9) 5025 SETBACK REQUIREMENTS NOT MET 11/19/2015 CRE
Proposed structure(s)must maintain a minimum of a 5'setback from all property lines,easements and 25'from
all County and State Road right of ways. Setbacks are measured from the furthest projection of the structure.
X
10) 5026 Structure Setback NOT MET 11/19/2015 CRE
Proposed structure or portions thereof,must maintain a 5'separation distance between adjacent structures and
that furthest projection.X
11) 5030 CHANGES TO APPROVED PLANS NOT MET 11/19/2015 CRE
All changes to"approved"building plans that effect compliance with the international codes as amended and
adopted,or any other Mason County ordinance or regulation,must be reviewed and approved by Mason
County prior to construction.
X
12) 5045 FIELD CORRECT NOT MET 11/19/2015 CRE
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY
BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department.
All construction must be in conformance with the international codes as amended and adopted by Mason
County. Any corrections,changes or alterations required by a Mason County Building Inspector shall be made
prior to requesting additional inspections.
X
13) 5600 FINAL INSPECTION REQUIRED NOT MET 11/19/2015 CRE
All building permits shall have a final inspection performed and approved by the Mason County Building
Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be
documented in the legal property records on file with Mason County as being non-compliant with Mason
County ordinances and building regulations.
X
14) 5700 PRESSURE TREATED LUMBER NOT MET 11/19/2015 CRE
Pressure treated wood manufactured after January 1,2004 may contain high concentrations of copper which
could quickly corrode metal fasteners,connectors,and flashing. Install metal connectors approved for contact
with the new types of pressure treated material.X
15) 6550 LANDINGS AND STAIRS NOT MET 11/19/2015 CRE
Landings and stairs must meet the same setback conditions as any permitted structure;and,must be shown on
your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the
setback conditions listed.
X
Page 2 of 2 CaseConditions..rpt
6/24/2016
Conditions Associated With 2:52:03PM
Case #: BLD2015-00959
Permit Condition Status Updated
item# Code Title Status Changed By Tag Date By
and amended by Mason County and the State of Washington. Occupancy is limited to the approved and
permitted classification. Any non-approved change of use or occupancy would result in permit revocation.
X
9) 5025 SETBACK REQUIREMENTS NOT MET 11/19/2015 CRE
Proposed structure(s)must maintain a minimum of a 5'setback from all property lines,easements and 25'from
all County and State Road right of ways. Setbacks are measured from the furthest projection of the structure.
X
10) 5026 Structure Setback NOT MET 11/19/2015 CRE
Proposed structure or portions thereof,must maintain a 5'separation distance between adjacent structures and
that furthest projection.X
11) 5030 CHANGES TO APPROVED PLANS NOT MET 11/19/2015 CRE
All changes to"approved"building plans that effect compliance with the international codes as amended and
adopted,or any other Mason County ordinance or regulation,must be reviewed and approved by Mason
County prior to construction.
X
12) 5045 FIELD CORRECT NOT MET 11/19/2015 CRE
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY
BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department.
All construction must be in conformance with the international codes as amended and adopted by Mason
County. Any corrections,changes or alterations required by a Mason County Building Inspector shall be made
prior to requesting additional inspections.
X
13) 5600 FINAL INSPECTION REQUIRED NOT MET 11/19/2015 CRE
All building permits shall have a final inspection performed and approved by the Mason County Building
Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be
documented in the legal property records on file with Mason County as being non-compliant with Mason
County ordinances and building regulations.
X
14) 5700 PRESSURE TREATED LUMBER NOT MET 11/19/2015 CRE
Pressure treated wood manufactured after January 1,2004 may contain high concentrations of copper which
could quickly corrode metal fasteners,connectors,and flashing. Install metal connectors approved for contact
with the new types of pressure treated material.X
15) 6550 LANDINGS AND STAIRS NOT MET 11/19/2015 CRE
Landings and stairs must meet the same setback conditions as any permitted structure; and,must be shown on
your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the
setback conditions listed.
X
Page 2 of 2 CaseConditions-rpt
ONE-CALL(# E SHOWN
AS INDICATED
ANCICH-SMITH STAIRWAY RECEIVED
BURIED UTILITIES ARE SHOWN AS INDICATED ON RECORD MAPS FURNISHED BY OTHERS AND �]
VERIFIED WHERE POSSIBLE BY THE ACCURACY
LOCATEDOF
HOIN THE FIELD.RECORDS,OR
HE FINLLOCATIO A PORTION OF SECTION 33, TOWNSHIP 22 NORTH, RANGE 1W, W.M.
ASSUMES NO LIABILITY FOR THE ACCURACY OF THOSE RECORDS,OR FOR THE FINAL LOCATION OF NOV 1 1 2015
EXISTING UTILITIES IN AREAS CRITICAL TO DESIGN.
MASON COUNTY, WASHINGTON .
STAIRWAY DETAIL & NOTES 426 W. CEDAR ST.
PLANNING:
PLANNING ALL SETBACKS ARE MEASURED
FROM THE FURTHEST
PROJECTION OF THE BUILDING
SEAWALL
I
4-X12-
TREADS
2"X6"RAILS
4"X4"POSTS
32'CTRS
8.66 2X6 DECKING
10.667' 4-X4- 8-TYPE
TREADS
1Yz-X8-X)'4 ANGLE W1(2)BOLTS,TYPE
4-X12- Y2"X8"BOLTS
STIN
4"X 12"STRINGERS
r FOOTING z zx1D
J ISTS
(2)4-XB-
POSTS
X CROSS SECTION X HAND RAIL X HAND RAIL (2) 4-X12-
cx ►TTS cx NITS cx NTS BEAMS
APPROVED
A kSON COUNTY DCD PLANNI . 3-x3-X6- _
PRESSURE TEATED 4X12 LUMBER(STEPS) S TE PLAN REQUIRED To 13E ON SI X'BOLTs
WITH COMPOSITE DECKING FOR LANDING&HANDRAILS86XS POSTS CHANGES S BJET TO APPROVAL
ALL FASTEIJERS ARE GALVUNIZED&ALUMINUM BRACKETS
I HAVE PICTURES IF NEEDED(1 DID NOT KNOW OF PAST STEPS) By AP�a Dale
— — — — — — — -
- — — — — — — — — — — — — — — — --w— — — — — — — — _ - - - - - - - - - - -
I I
I n Eve s . .-
B
R
d
y — — — — — — — —75, — _29,_ 2X LEDGER BOARD
0 1P
F�c16-�in I
X STAIR LANDING
NITS
X PROJECT AREA SITE VIEW
7 CX NTS
S
a -
L TITLE
y MONUMENT REMOVAL PERMIT PROCESS � � �B tG R ABgl� ANCICH SMITH REANING WALL WestSound
a NO SURVEY MONUMENT SHALL BE REMOVED OR DESTROYED(THE PHYSICAL DISTURBANCE OR �e Engineering, I n c
COVERING OF A MONUMENT SUCH THAT THE SURVEY POINT IS NO LONGER VISIBLE OR READILY _ Z DETAIL&NOTES
ACCESSIBLE)BEFORE A PERMIT IS OBTAINED FROM THE DEPARTMENT OF NATURAL RESOURCES DRAWN By ATB - a ENGINEERING,PLANNING AND SURVEYING
9 (DNR),WAD 332-120-030(2)STATES-IT IS THE RESPONSIBILITY OF THOSE PERFORMING
CONSTRUCTION WORK OR OTHER ACTIVITY(INCLUDING ROAD AND STREET RESURFACING 21 D50 A� CLIENT 217 S.W.Wilkins Drive Port Orchard,We.98366
' PROJECTS)TO ADEQUATELY SEARCH THE RECORDS AND THE PHYSICAL AREA OF THE PROPOSED CIffqKOBv OTB SIONAL CHERYL ANCICH-SMITH Phone(360)876.3770 Fax(360)878-0439
4 CONSTRUCTION WORK OR OTHER ACTIVITY FOR THE PURPOSE OF LOCATING AND REFERENCING
ANY KNOWN OR EXISTING SURVEY MONUMENTS.-CONSTRUCTION SHALL NOT COMMENCE UNTIL 1 W.EDGEWOOOD�' E-mail:vne@wsengineedng.mm http:lfwww.vrsengineering.com
WAD OUTLINED Cl IN CHAPTER 332-12015 COMPLIED WITH. SEC 7NN R 1W SUN 85351
SCALE NTS REV. DESCRIPTION DATE BY DATESEAIED 10.OB-2015 2W1&7488 JOB No. 2421 SHT 1 OF SHTS