Loading...
HomeMy WebLinkAboutBLD2016-01191 SFR - BLD Permit / Conditions - 2/24/2017 Inspection Line (360)427-7262 5�N CO U MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County 615 W Alder St Shelton, WA 98584 'H' RESIDENTIAL BUILDING PERMIT BLD2016-01191 OWNER: PETER AUSTIN RECEIVED: 12/13/2016 CONTRACTOR: LICENSE: EXP: ISSUED: 2/24/2017 SITE ADDRESS: 5513 E STATE ROUTE 302 BELFAIR EXPIRES: 8/24/2017 PARCEL NUMBER: 122335000032 LEGAL DESCRIPTION: OLYMPIC SHORE N 150'TR 16 E OF R/W PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR (ADU SEE DDR2016-00154) ST RT 3 TO ALLYN, R ON NORTH BAY RD, FOLLOW TO ST RT 302, FOLLOW TO SITE ADDRESS 5511, SHARED DRIVEWAY General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: 620 Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,000 Valuation: $ 144,145.72 Building Height: 17 Occ. Status: Primary Basement:523 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: W 184.0 Ft. Shoreline: Ft. Water Body: Rear: E 220.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 40.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 39.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Furnace<100K 1 Plan Check Fee GMM 12/13/201 $809.74 S3201700000001 Lavatories 2 Heat Pump 1 EH Plan Review GMM 12/13/201 $205.00 S3201700000001 Bath Tubs 1 Ventilation Fan 3 Planning Review Fee GMM 12/13/201 $205.00 S3201700000001 Showers 1 Propane Tank 1 Building State Fee SLC 2/8/2017 $4.50 S3201700000001 Water Heaters 1 Gas Outlets 4 Building Permit Fee SLC 2/8/2017 $ 1,245.75 S3201700000001 Clothes Washer 1 Exhaust Hood 1 Mechanical Permit Fee SLC 2/8/2017 $ 164.90 S3201700000001 Kitchen Sink 1 Dryer Vent 1 Mechanical Base Fee SLC 2/8/2017 $28.50 S3201700000001 Dishwasher 1 Plumbing Permit Fee SLC 2/8/2017 $93.20 S3201700000001 Hosebibs 2 Plumbing Base Fee SLC 2/8/2017 $24.70 S3201700000001 Total $ 2,781.29 BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2016-01191 CONDITIONS FOR BLD2016-01191 1) On-site septic system final installation required prior to temporary/final occupancy(SWG2016-00303). 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building X ep�rrgnt\ rior to any further inspections being performed or approvals granted. CCTV 4) Owner A t is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. ,y 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal,oL2Dproved documents will result in failure of required building inspections. X (f y 6) THE��J�VDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X �T .�7 7) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Build' JL e artment prior to any further inspections being performed or approvals granted. X �<�lli BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 2 of 7 8) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 3A- PROPANE FURNACE WITH MINIMUM AFUE OF 94% (1.0 CREDITS) 5A-WATER CONSERVING FAUCETS AND SHOWER HEADS (0.5 CREDITS) x 9) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECCLWSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in %<or'/2 sheets. The Mason County Permit Center will also have some available. X t1, I ,,� 1 10) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1./ X l l L4, 11) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (I RC 2012 R905.2.8.5) � 11 X / 1 Q , Vt 12) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 3 of 7 13) Archaeological or historical resources, such as ruins, sites, buildings, artifacts, fossils, or other objects of antiquity that may have significance from an historical or scientific standpoint, which may be encountered by the developer/contractor, shall not be further disturbed. If the developer/contractor encounters any such artifacts, he/she shall immediately stop work and notify Mason County and the Washington State Department of Archaeology and Historic Pr se ation. Failure to do so may result in civil penalties. X E 14) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air frn tside in accordance with the international codes. X 3 \-)it 15) A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet 1 designate wall(s) type PORTAL with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submiitt�d to he Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. X ( z,t� 4 16) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concfreete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). ca 17) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X 18) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where X such ropd1oonnne,cct with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. 'I LL 4 19) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit re cation. X ft.0I// BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 4 of 7 20) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. X /RD 21) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your Xproject./9Z 1�/ 22) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance gr g la jion, must be reviewed and approved by Mason County prior to construction. �/ 23) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector s spector t1all tgmade prior to requesting additional inspections. � ,� i BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 5 of 7 24) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10'from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards yr�kst�installed. 25) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X ►(z 26) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the in t la ion requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. Xr 27) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used un it the final inspection has been performed and approved by a Mason County building inspector. X 4izL I 28) Owner/applicant must obtain a seperate permit for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit prior to the placement of the tank. X 44 r 29) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think such features-exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 30) All property lines shall be clearly identified at the time of foundation inspection. X!M !� 31) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason CouU��l inances and building regulations. X 32) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have ented action from being taken. No more than one extension may be granted. X BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 6 of 7 33) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, Xnnectors,, d flashing. Install metal connectors approved for contact with the new types of pressure treated material. 34) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X j"�`.1�, 35) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your Approved Site I�Ipn"to ensure these structures are shown and meet the setback conditions listed. 36) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLYAFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAY. x 6241-3 OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLIC TION OF 180 DAYS WILL INVALIDATE THE APPLICATION. 7- z e-/-J7 Signature Date 14� OWNER - REPRESENTATIV - CONTRACTOR 'Print Name (Circle one to indicate) BLD2016-01191 Please refer to the following pages for conditions of this permit. Page 7 of 7 Parcel 3y BLD# A 01 JP — LO I II Mason County -- ADepartment of Community Development DEC 2 3 116 Small Parcel Stormwater Management Application/Worksheet(page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: hMHwww.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A v ✓ e relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in th'dir entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. i Q� An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the sy m will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14-48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowl m to such is y signature below.I declare that I am the owner,owner's legal representative,or the contractor,I further ac t the fo�a6on provided is accurate and employees of Mason County are described pro f vi n d in ection as may be required, ty panted access to the above- X /Agent/Contractor(circle one)Date: �14 t L(Eb Page 2 of 2 �6 NameBeit C (AV_5 i'n par'cel#�22 � �d — O06 _BLD# `�.�el�n �a►leY Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. Surface Type Length X Width = Area "All dimensions In feet Buildings O X ©© X Measurements for buildings are taken at the X = perimeter of the farthest projections(example.- eaves/gutters) X = Driveways 3 O X _ clo X — Length of drive begins at the right of way X = Parking Areas X 'Z X Any paved,gravel or packed area per definition X _ above table Patios/Walks X = X Any paved, gravel or packed area per definition X _ above table Others X _ X X = El 2� If the Total Impervious Surface Area is LESS THAN 2000 Sguare Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement f such * by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further Lat information provided is accurate and employees of Mason Countyare descri pr f inspectio as may be required. gran access to the above. X Owner/ gent/Contractor(circle one)Date: If the Total Impe loos S rface Area is G ER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 WSEC/Ventilation Code Compliance Application Submit with heating/cooling system size worksheet (see instructions #4) u6o Owner: Parcef#. Type oADU project:V'v .. Peter S Austin Jacquelyn B Talley Total Sq. Ft. 1000 15'Floor: 2nd floor- Heated Basement: of heated area:: Heating System Type: ©Electric wall heater MElectric Central Furnace ` LPG Furnace " Heat Pump with electric furnace IflHeat pu�!p with gas furnace GNDuctless Heat Pump Boiler, specify fuel type: 00ther: Specify: Prescriptive Option Table R402.1.1 (see table on previous page) Compliance Method RO Component Performance, R402.1.3— calculation worksheets required Must Check one:: `° Other (Specify); Check one ®Whole House Ventilation system 191Whole House Ventilation Ventilation using exhaust fans&window or wall Integrated with a Forced Air "3 ther,describe. fresh air vents(M1507.3.4), If using System (M1507.3.5) System window vents be sure to order windows with vents. Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements,"all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason wa.us/forms/Community Dev/iecc wsec odf a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor Additional area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc). Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor Efficiency but less than 1,500 sq ft of floor area. Requires 1.5 credits Requirements b) Medium dwelling units that are not included in (a) above (small dwelling), OR(c) below Energy credits {large dwelling)Requires 3.6 credits required: EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5 L' credits. See page two for description. c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq, ft. of heated or cooled floor area. Requires 4.5 credits d) Additions less than 500 sq feet. Requires .5 credits (Fenestration is defined in the IECC as skylights, ro azed-doors that include of windows, vertical windows, opaque doors, l products with lass and non-.glass glazinq materials. Describe Energy Credit Option(s): ? Using Option number(s): 3 FENESTRATION'SCHEDULE USE FOR ENERGY CREDIT,a1 SMALL DWELLING OPTION&COMPONENT PERFORMANCE COMPLIANCE List all windows, doors skylights (If needed attach an additional sheet) 'Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include produI is with glass and non- lass glazing materials. Manufacturer Location U-Factor Size quantity Total (rough opening) Square Feet Ei�ey CooRS 3 r � Sl�d�n d sr C2-0 I c� PtC+ cited ( � ' r^� er bet '- w r%I4OkLj Total Fenestration: windows, skylights and door area 4 MASON COUNTY RESIDENTIAL PLANS SUBMITTAL =CKLIST �14tr I �a. la.ltP Owner's Nam -A U6ti n :.ate: Project description: .5 F P_ - ��{U, Documents: y "� ►/wilding Permit Application Completed. D L uG DIX 2 3 LGo6 ✓_Mechanical/Plumbing Application Completed. 615.W. Alder Street _✓Planning Intake Checklist Completed. ✓Site plan includes:Allowable building area, roof ovediangs, decks etc' 'n ire Apparatus &Access Road info required? Yes No EX164� roc 7v C.C.255 _Stormwater Checklist Completed. �✓Energy Code Application Form- O Electric wall heater O Electric cen I furnace O LPG Furnace O Heat pump with electric furnace • Heat pump with LPG furnace O Boiler(heat type ) O Ductless Heat Pump O Other. Specify: Construction Plans: ,2,_�Sets (2 full size sets w/engineered calculations & 1 reduced sized set 11X17 min.(no calculation needed ) _/Plans Legible _/Recognized Scale ✓Elevation Views _✓Cross Section L1Foundation Plan Roof Framing Plan _✓Floor Plan—Use of rooms labeled (all floors) 7/ Floor Framing Plan -all floor levels including loft, crawlspace, etc. _/Deck Framing Plan including covered porch, carports Plan Details: _✓Roof framing details, truss lay-out may be needed (Hip and girder location shown) _✓Wall Framing - Does bearing-wall height exceed 10'?(Engineering may be required) 16 m A X ✓Floor framing: Floor joists (size& spacing)I x i;;), 1 Jsi-. I Uoc— , Floor beams:KryA_LU �, ux 7 Window headers. Typical header. +XIQ t 4X 12 Garage header. 3 6 X IO.S _✓ Foundation: footing size, reinforcement 56rdAe,came. Concrete Walls- Does Concrete Wall Height Exceed 8'? (Engineering may be re ulbd see details) � �� 9 ( 9� 9 Y q � ✓Landings at all exits? Less than 30' above grade'.�Y N (must be shown on site plan) ,l{ f 1 �Nater Heater. Location:5r}p Type: . LP I l 7 Heated By Furnace- Location of umace uel type, -) L.P61 � �6 _ Location(s): V Window Sizes Marked on Plans. _✓Braced wall panels(shear walls) MUST be markedfindicated on plans. - -ZEngineered. Yes/ 1 Snow load: Seismic: D2 Design Code: Are plans stamped Manufactured Homes: Q4f 5nCc4 _64'E _4 Floor Plans (rooms &areas must be labeled) 11_*011nA ,_- Foundation Type: ANSI/Manufacture method Engineered foo undation Basement Decks": 4x4 min. landings requi each entrance (must be shown on site/plot plan) "`Covered decks or an decks are than a 4'x4' that exceed 30.fromgrade) requires a permit and constructi ins. CO TS: Intake review (initials): Date: �� H:\permit tech building checiclist2015.doc evised 8.52016 If any of the items listed below are either indicated or missing within the construction documents,- the plans must be engineered or returned to the applicant for resolution. ENGINEERING REQUIRED: Braced vrall paneis/brace wall lines are not marked on plans (R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRfTEfclA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B (unless proven otherwise). Seismic Zone: D2, Snow_psf. IRREGULAR BUI LDINGS R301.2.2.2.5 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur. 1) Exteric>r shear wall or braced wall fine are not in one plane vertically from the foundation to the uppermost story in which they are required. See exceptions. 2) Roof or floor is not laterally supported by shear walls or brace walls fines on all edges. 3) Portion of roof or floor extend more than 6 ft. beyond the braced wall line. 4) End of BWP extends more than 1 ft over an opening more than 8 ft in width below. 5) Opening in a floor or roof exceed the lesser of 12 ft. or 50% of the least floor or roof dimension. 6) Portions of door level are offset Vertically 7) Shear wall fines do not occur in two perpendicular directions. 8) If a story above grade includes masonry or concrete construction*When this applies the entire story shall be designed. In accordance with accepted engineering practice. *(exception: fireplaces, chimneys, and veneer as permitted by the code). ***Applicant must take plar s to a design professional to address items indicated above-" Notes/Comments for design professional: L\permit tech buildin-checkLst2015.doc Revised 8.52016 MASON COUNTY COMMUNITY SERVICES PERMIT ASSISTANCE CENTER: Permit No:. •BUILDING • PLANNING • FIRE MARSHAL 615 W. Alder St- Shelton, WA 98564 /LL+ Phone Shelton:(360)427-9670 ext.352 • F8x:(360)427-7798 Phone QL I. 1 3 2Q�6 ^j Be!(aa:(360)275-4467• Phone Elma:(360)482-5269 > BUILDING PERMIT APPLICATION KOO Mr smmt PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Peter S Austin Jacquelyn B Talley NAME: Same as Owner MAILING ADDRESS: 5511 E btate ou e MAILING ADDRESS: 1!7 CITY: Belfair STATE: VVA ZIP: 98528 CITY: STATE: ZIP: PHONE#I: 52_203�-� PHONE: CELL: PHONE#2: EMAIL EMAIL r O e nop I L&I REG# EXP. CONTACT PERSON : OWNER X CONTRACTOR X OTHER❑ NAME: Le- -f U A l Al[Ct MAILING ADDRESS: E�34 �3012 � t CITY: STATE'.\&)-L—ZIP: PHONE:3�06��303! CELL:2419949LO l�l EMAIL: l9 Cp �l PARCEL INFORMATION: � PARCEL NUMBER(12 Digit Number) 12233-50-00032 ZONING B J 5 LEGAL DESCRIPTION(Abbreviated) Olympic Shores North 150 feet of Ttract 16 FIRE DISTRICT '-�z SITE ADDRESS 55l ) E State Route CITY Belfair r DIRECTIONS TO SITE ADDRESS 7 miles East of Belfair Center on Route 302 IS THE PROTECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%:?YES hd'-/ NOD IS PROPERTY WITHIN 200 FT: (Check all that apply): ` SALTWATER D LAKE❑ RIVER/CREEK D POND O WETLAND D SEASONAL RUNOFF ❑ STREAM❑ TYPE OF WORK: NEW X ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER D USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.} A D U IS USE: PRIMARY)tl SEASONAL❑ NUMBER OF BEDROOMS 1 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(Whole Bldg)D YES(Part[s]of Bldg) X NO D DESCRIBE WORK 106 C 6 �, w nrdcc BidAmQatttt;';3 SQUARE FOOTAGE: U TU, 06 YK— U n Kitje ISTFLOOR sq.ft. 2ND FLOOR 1000 sq.ft. 3RD FLOOR sq.ft. BASEMENTA sq.ft. DECK__sq.ft. COVERED DECK L4 8 sq.ft. STORAGES ' �q.ft. OTFIER_ �q.ft. GARAGE sq.& Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH TH BEDROOMS BATHS SERIAL NUMBER OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the worik as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or legal representative, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 1 so rlavc IlL0 VW- 15't-z- Z'ed 1'7 L"i p"LiCID MASON COUNTY COMMUNITY SERVI CES PERMIT ASSISTANCE CENTER.- ZNUIL.DING 0LANNING®IRE MARSHAL Putt No: 615 W. Alder St-Shelton, WA 98584 _ v".co.Mason.wa.us Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 C Phone$elfair. (360)275-4467• Phone Elma:(360)482-5269 D`C 2 3 2016 PLUMBING & MECHANICAL PERMIT APPLICATION W. Alder Street. OWNER INFORMATION: NAME: Austin acquelyn B Talley CONTRACTOR INFORMATION: MAILING ADDRESSS Routre NAME: — - Epp CITY: Belfair STATE: MAILING ADDRESS: lu PHONE:360-55 -2036 WA ZIP. CITY: STATE: '� 1`ZIP: EMAIL:PHONE:` 219-398 996 PHONE: CELL: EMAIL: EMAIL mail.com L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number): 12233-50-00032 LEGAL DESCRIPTION(Abbreviated). YmpIc Zoning: SITE ADDRESS: 551 1 E Sla CYDIREC7GSSsGlE mileE0 W 2 -- --- WP E OF JOB: ADD ALT REPAIR OTHER LOCATION OF FL TU_S/UNITS_1sT FLOO-RR—Y 2NDFLOOR USE OF BUILDING BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) TL+ne o— fF__i_� fFixtures_xture No. MECIIANICAL UNITS Toilets Fees Fuel Type:Electric_LPG Natural Gas Ductless Bathroom Sink Tvae of Unit No,of Units Fees Bath Tubs ---- Furnace Showers Heat Pump —--- Water Heater Spot Vent Fan Clothes Washer ----- Propane Tank I '�— Kitchen Sinks Gas Outlets Dishwasher — Wood/Gas/Pellet Stove Hose bibs Kitchen Exhaust Hood 1 Other Dryer Vent —'----- Solar Panel —`-- Base Fee Other ---- TOTAL PLUMBING Base Fee —---- TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that 1 am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder aor parties of interest regarding this project The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null 8 void if wo cons ction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF c%v ATI OF S PERMIT IS BY MEANS OF INSPECTION.INACTNITY 0 THIS RMIT APPLICATION WILL�� E A QAT10N. ��A �1� OF 180 DAYS X �YY Signature of Owner 1�_( t' Date \ DEPARTMENTAL REVIEW APPROVED DATE BUILDING DEPARTMENT 7 f DENIED DATE TAGS/NOTES/CONDITIONS PLANNING DEPARTMENT FIRE MARSHAL Visit us nn-1;n kf# i,. ._.. PL/`"iNN a �. � ■ r'_.L SETBACKS A-RE ' _ 31,11r,Er FROM THE FUrN! '-' "?T PLANNING PROJECTION OFT, ?if s' 615 W. Air Street / ADJACENT S.F.R. �il1 ELE. �...._........__..- `J 20' G# / 154' / ELE. ELE. \ _- 40'. so 80 NORTH ELE. — / \ Rj. N89*12'12"W 518.86' / I 100' / I \ �� 6 —C 5' SETBACK LINE /- - — j - - -T- - - - - jEXIST. U.G.-SEWER-LINES-`c=__� \ 5 L}p'A�..C1 \ / I \ / { SHED I� / ao �•1: \ SEPTIC io /�,�� L/ I I ..<GRAV@l.DRNEWAY �y.. \\ �` I JANK tn- _fTl I u�i W W N I I \ 274 ,� Vim✓ w //� j I I 1398 IIt 04 Ld E——_ _ I PROPOSED �C�� /_ 70>\ to C9 0: LI SEPT I I S3 �.G. T 6 � I , —A.D.U. 1000 SQ. FT. / T\ N \ L) o I I TANK 30 DECK 572 SQ. FT. / \ p m z j _ 1 1 I j�, ENTRY PORCH 47 SQ. FT. p\\ / 11 55 I \J \I D.J. AREA 1359 SQ. FT. 2p\\\ +/ - v ��PUMP 0— F q \ _ I � TANK QO�FFL t `\ _ / r" SUBJECT PROPERTYoZ20 ` r_' a 5511 E STAT/ O Site Plan Requirements Checklist \���' --� - Qo�� / BELFAIR WASI3INGTON 8528 f W Parcel k J/ / N PARCEL 1 2133-50-0003 2 Shown N/A Namber 12233-50-00032 / A General Property Information: exlsnNc eLncKroP_,p — —'` � - — — 1 Q3 SETBACK LINE Tax ID Number and Property Address •�--= ----�— —T _ P D+MAY ,j- —�� -r/ — —_ — — / —� -- Pit S89*12'12"E 500.60' Property lines and dimensions I \ 20D' \ POT, 17- ELE. / Elevations of property and the 4\ ELE. f direction of natural drainage ❑ Slopes that exceed 157l including any - 60\ ' ����� I $O cut banks greater than 4' in height - - - ,iL„Jji.;'. North arrow and site plan scale - ! ❑ Marine waters lakes and ponds and i _ MASON COUNTY D�CD PLA+NNI� Streams, creeks & wetlands and thier thier associated high water lines SITE PLAN I SITE PLAN REQUIRED TO BE ON SITE Cl associated Duffer areas SCALE 1 �► I CHANGES SUBJET TO APPROVAL B Existing Property Improvements: INCH=5 0 FEET t Location of all existing structures ,�� �8x$ —, �� km ❑ including the locations of existing I structures on adjacent waterfront properties Location of all existing wells and t dj. ❑ well rid..,including Nose wells on adjacent j properties within 100' of property Iinea f ❑ Location of all existing droinfields including the 10' "No Build Zone" as well as the locations of existing drainfields on r� adjacent properties within of any well - ❑ Locations of existing drainage facilities, including all sub—surface infltraGon systems Location of all existing and abutting road ❑ ways, driveways, easements, buffers and - regmred open spaces - - ❑ Location of existing water, sewer and - utility lines C Proposed Property Improvements: PROPOSED A.D.U. 1000 SQ, FT. PETER & JACQUELYN AUSTIN Locations and dimensions of all pact. - COVERED ENTRY PORCH 47 SQ. FT. 551 1 E STATE ROUTE 302 ❑ tp,t.rea, or building envelopes n relation to property lines,other structures,act. ❑ Location of all proposed well, including DECK 572 S Q. FT. B E L FA I R WAS H I N GTO N 98528 thier 100' well radii and all water lines Locatiopre treatmn of all prent units,oposed se an dreinfi e am pticd tank,pas. tanks, TOTAL ROOF AREA 1359 S0. FT. PARCEL #122.33-50 including the 10'"no build" ne .-00032 ❑ zo ❑ Location and dimensions of all proposed drainage and infiltration systems NeLocations, dimensions, surfacing materials, SITE P L/�N 1 2/0 6/1 6 ❑ and clearing limit. of all proposed parking anaa,driveway..sidewalks.R road Opp— - ❑ Location lity l nes of,proposed water, sewer !:� JaCgMe1yj7 Austin PAGE and uti SITE PLAN of 1