Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2006-01931 Cancelled Convert Garage to ADU - BLD Permit / Conditions - 4/16/2011
Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 ' Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2006-01931 OWNER: RALPH EATON CONTRACTOR: LICENSE: EXP: �� •. RECEIVED: 10/31/2006 SITE ADDRESS: 1150 E PHILLIPS LAKE RD SHELTON ��� FD EXPIRES: 5/27 20006 PARCEL NUMBER: 221325100012 LEGAL DESCRIPTION: PHILLIPS LAKE DIV. 6 TRS 12 & 13 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Garage/Ag. Building Pickering Rd. to Phillips Lake Rd. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 0 Type of Constr.: V-B Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U (Ag) Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:5,908 Valuation: Building Height: Occ. Status: Primary Basement: Cov. Porch 60 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 285.0 Ft. Shoreline: Ft. Water Body: Rear: N 30.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: W 15.0 Ft. Shoreline Desi g.: Not Applicable Year: Serial No.: Side 2: E 20.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 6 Plan Check Fee KKK 10/31/200 $802.46 S22006000 Kitchen Sink 1 Planning Review Fee KKK 10/31/200 $155.00 S22006000 Lavatories 1 EH Plan Review TW 11/2/2006 $35.00 S22006000 Water Closets (Toilets) 2 Building State Fee JRN 11/2/2006 $4.50 S22006000 Water Heaters 1 Building Permit Fee JRN 11/2/2006 $1,234.55 S22006000 Bath Tubs 1 Plumbing Base Fee JRN 11/2/2006 $20.00 S22006000 C!othes Washer 1 Plumbing Fee JRN 11/2/2006 $55.00 S22006000 Total $2,306.51 BLD2006-01931 Please referto the following pages for conditions of this permit. 1 of 5 17). All slabs within the heated space shall be insulated to a--minimum R-10 for at least 24". Monolithic slabs shall be insulated around the perimeter from the top of the slab to the bottom of the footing X 18) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X �UJ 19) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to r6questing inspection . X \�' 20) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. 21) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X � 22) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. t XLL 23) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647- 982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X � 24) This parcel is located in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information. x 11 \,� 25) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 26) No Issues for EMS/Fire Apparatus BLD2006-01931 Please referto the following pages for conditions of this permit. 4 of 5 CASE NOTES FOR ' BLD20 0 6-01 9 31 CONDITIONS FOR BLD2006-01931 1) A separate permit is required for the change of use of any portion of this structure. Occupancy separation wall locations and ratings must meet or exceed minimum code requirements ir�effect at the time of application for required change of use permit. (See 2003 IRC Section R309.2, IBC Section 406.1, and IBC Appendix C). X K w 2) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors,.and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X )�\-k) 3) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X L__L 4) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 'r_ 5) All property lines shall be clearly identified at the time of foundation inspection. X ��,� 6) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector Shall be made prior to requesting additional inspections. X 't v 7) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance Qr regulation, must be reviewed and approved by Mason County prior to construction. X t( BLD2006-01931 Please referto the following pages for conditions of this permit. 2 of 5 8) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further i4ormation regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X Caw' 9) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev cation. x -4- 10) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged n�d}shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 11) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 12) Per 2003 IRC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accorda ce,with the applicable provisions of this section and the manufacturer's installation instructions. Xl,C. 13) Per 2003 IRC -SECTION 1609 -WIND LOADS- 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC W ND SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X IT 14) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38,Vault Insulation R-30, Slab Insulation R-10. X d \)v �c 15) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 1(�IJ 16) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X BLD2006-01931 Please referto the following pages for conditions of this permit. 3 of 5 27) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further ormation regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 28) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 29) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: _ � y�.J�`_ ` DATE: BLD2006-01931 Please referto the following pages for conditions of this permit. 5 of 5 f 8 1 t S� Inspection Line(360�127-7262 MASON COUNTY DEPT. OFI�'(MUNITY DEVELOPMENT Phone: (360)427-9670,ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2006-01931 OWNER: RALPH EATON RECEIVED: 10/31/2006 CONTRACTOR: LICENSE: EXP: ISSUED: 6/3/2008 SITE ADDRESS: 1150 E PHILLIPS LAKE RD SHELTON EXPIRES: 12/3/2008 PARCEL NUMBER: 221325100012 LEGAL DESCRIPTION: PHILLIPS LAKE DIV. 6 TRS 12 & 13 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE Pickering Rd. to Phillips Lake Rd. USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED "LIVING SPACE" (EXISTING HOME General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 0 Type of Constr.: V-B Type of Use: SF Insp. Area: No. of Bathrooms: 3 Occ. Group: R3/U (Ag) Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,776 Garage-Attached 3,912 Valuation: Building Height: Occ. Status: Primary Basement: Cov. Porch 60 Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft. Front: S 285.0 Ft. Shoreline: Ft. Water Body: SEPA?: NO Rear: N 30.0 Ft. Slope: Ft.Model: Width: Ft. Side 1: W 10,0 Ft. Shoreline Desi g Not Applicable Year: Serial No.. Side 2: E 15.0 Ft. Comp. Plan Desig.: Rural BLD2006-01931 Please referto the following pages for conditions of this permit. 1 of 7 Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 6 Exhaust Hood 1 Plan Check Fee KKK 10/31/200 $802.46 S22006000 Kitchen Sink 1 Furnace<100K 1 Planning Review Fee KKK 10/31/200 $155.00 S22006000 Lavatories 3 Gas Outlets 4 EH Plan Review TW 11/2/2006 $35.0o s22006000 Showers 3 Propane Tank 1 Building State Fee JRN 11/2/2006 $4.50 S22006000 Water Closets (Toilets) 3 Ventilation Fan 3 Building Permit Fee JRN 11/2/2006 $1,234.55 S22006000 Water Heaters 1 Heat Pump 1 Plumbing Base Fee JRN 11/2/2006 $20.00 smbo bbb Bath Tubs 2 Propane Stove 1 Plumbing Fee JRN 11/2/2006 $55.00 S22006000 Clothes Washer 1 Dryer Vent 1 Planning Dept. Permit KJM 5/22/2007 $55.00 S22007000 EH Permit Revision TW 11/20/200 $35.00 S12007000 Additional Plan Check Fee MAL 12/4/2007 $245.21 S12007000 Building Permit Fee MAL 12/4/2007 $377,25 S12007000 Plumbing Fee MAL 1 2/412 0 0 7 $59.40 s12007000 Mechanical Fee MAL 12/4/2007 S52.00 S12007000 Mechanical Base Fee MAL 12/4/2007 $25.30 S12007000 Mechanical Fee GMM 6/3/2008 $167.15 S12008000 Mechanical Base Fee GMM 6/3/2008 S8.40 S12008000 Total $3,331.22 CASE NOTES FOR BLD20 0 6-01 9 31 CONDITIONS FOR BLD2006-01931 1) Appr yrr dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 2) This parcel is located in a smoke management zone. Please contact a fire warden at (360) 427-9670 ext. 459 for further information. X Z 3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-6 7-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 4) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such rQJds connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ; BLD2006-01931 Please referto the following pages for conditions of this permit. 2 of 7 ` 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Departme t �py further inspections being performed or approvals granted. X l./ 7) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspec X4 8) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal f approved documents will result in failure of required building inspections. X 9) All slabs Within the heated space shall be insula o minim - r � um R 1 0 for at least 24". Monolithic slabs shall we insulated around the perimeter from the top of the slab to the bottom of the footing X 10) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X ,t 11) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildin e rt ent prior to any further inspections being performed or approvals granted. X 12) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight(Max U-Factor):0.58, DooNFZ%_ ax U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X 13) Per 2003 IRC -SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BAS X I D SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. 14) Per 2 03 IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in X with the applicable provisions of this section and the manufacturer's installation instructions. X BLD2006-01931 Please refer to the following pages for conditions of this permit. 3 of 7 w ` 15), Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical co to work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X t. 16) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be chargo and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X� 17) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in perm cation X . 18) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to b located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your pro X 19) All change to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance tion, must be reviewed and approved by Mason County prior to construction. XL 20) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with a international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Ins shall be made prior to requesting additional inspections. X 21) All property lines shall be clearly identified at the time of foundation inspection. X 22) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to requ st a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with ty ordinances and building regulations. X BLD2006-01931 Please referto the following pages for conditions of this permit. 4 of 7 23) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for. eriod not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (old r ented action from being taken. No more than one extension may be granted. 24) Pressur treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, co rs, flashing. Install metal connectors approved for contact with the new types of pressure treated material. X t� 25) A separate permit is required for the change of use of any portion of this structure. Occupancy separation wall locations and ratings must meet or exceed minimum code requi i effect at the time of application for required change of use permit. (See 2003 IRC Section R309.2, IBC Section 406.1, and IBC Appendix C). 26) No Issues for EMS/Fire Apparatus 27) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to b located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your t. X 28) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your 1. d Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 29) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. 30) No part of this plan has been reviewed for sleeping purposes. Any room for sleeping requires a smoke detector and means of egress. See items#2 and #3 in ched plan review checklist. X 31) Part of this structure (garage/ag use) is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, hange of use permit shall be applied for, reviewed and approved prior to the change. The heated portion must be thermally isolated from the un t portion. X 32) The use, handling and storage of ha ous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marsh BLD2006-01931 Please refer to the following pages for conditions of this permit. 5 of 7 33) Part of this structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of • the io odes a n County RegMio u ss a"Change of Use" permit is applied for, reviewed and approved. 34) Installation of heating equipment in single family residences shall meet the requirements of the current Washington State Energy Code. The furnace to be installed shall not exceed 150% of the heating and cooling design load. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted engineering practice, including infiltration and ventilation. Design calculations shall be available for inspection during the framing inspection. Warm-air furnaces shall have a minimum efficiency of 78%AFUE or higher or 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with manufacturers installation instruc uct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X = 35) Owner/applicant must obtain a seperate it for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit prior to the placement of the tank. X 36) Engineering for the changes to this structure were not available at Ian review. This review was expedited per the owner's request. Per conversations with owner and designer the engineering for any/all changes will to by the time of inspection. No construction should be undertaken without approval from the engineer for changes to the structure. X 37) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air fro tsi a in accordance with the international codes. X 38) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollard ust a installed. X t 39) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X 40) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet tfA installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X BLD2006-01931 Please referto the following pages for conditions of this permit. 6 of 7 ' 41)- Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not sed until the final inspection has been performed and approved by a Mason County building inspector. X id - 42) Owner/applicant must obtain a seperat rmit for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit prior to the placement of the tank. 43) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Suc regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think su res exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X t 44) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these tructures meet the setback conditions listed. X fey This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described pro and ucture for eview and inspection. �+ OWNER OR AGENT DATE: BLD2006-01931 Please refer to the following pages for conditions of this permit. 7 of 7 co ". o CONCRETE MECHANICAL MANUFACTURED HOME D o Date T Footings /Setbacks Crag Piping Ribbons Z o Interior Gate By interior-©ate By data By . w Exterior Date 1 O By !i Exterior-Date B Set-up Point Load/Isolated Footings INSULATION pate By � BG I SLAB INSULATION _ Date By Data By FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING -r rA Walls Date By Date r -13 — By Date -V �� �Y. PROPANETANKS PLUMBING vain Date By Date By OTHER Groundwork Attic — . Type: Data ,.3 -f 7By Date By Date By D.W.V DRYWALL Type: B Int Brace Wall Date By W y Date By _ r o FINAL INSPECTION Water line > Fire Separation G Ua1 By Date By Date By O m � `D Pass or Request Inspect. o Type of Insp. Fail Date Date Done By Comments CID w � iv w .9vi_s CD 22 cam` o 8 0 1'00 l-+ i1 =3o-1 61.4 El Afte, ,3,�,.y �, r�IJ yn�rc l-errir � �ftn co" P�,cIA wyi'+ Pu�.s IZz �� ► H � � � ,r ii �; �,�u �s a 1 -1 i f �s 1'0 i L�, c� �r 0 � Y� hors �117- `� �� � �� c0V pf�-% �1 r. �I-l�f-1 2b"8 �'�(� .�+I�n f}-t ✓�� T n FC:4;I INI Am, .J F/foNE, �b -I S—v�g l�c� y �av 7u4�v �o a� goy f�C f.�•z �.0 i Building Permit # 06 —0Vrt3 MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location L150 ��- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance t v'Stou k -rlo " 1 v` V ✓S rS be +4'roesw. . Covh f -Pya GF 1 o cL 4cb e>- t ►�S{all C0.0 I I�- b 2G l( �- a�o vv� o��C d V r 0.S 0.-�2v In c� Y 4-oo v V,J �-Xo w �aS 4 ls'i K� k o4 S r� [�f K&4 S Y v� " c�V G h4j-v CLJ V PAS �-i -�V Pam✓ ✓l aJ^'� . v�-i o'-1 S V O- - V 04- t')OLSI,-�s o ey aifS 40 3`r I r W -. o.." '% V, 'P-1I ` is `IS `I ���.rS -P,v✓t c.J h s4-^j 1 ( i e� Q oO VAnP (o.�-e SvP)2 Dell You are hereby notified that the above corrections shall b made BEFORE PROCEEDING WITH ANY FURTHER WORK all for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department Date ' ZZ_ Inspector ■ oo s :JOT Mk *V ; THI - T A Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance a You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department Date ✓� �l" 07 Inspector " ■ oks :JOT MOOV THI T ,�� Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items.Listed below mus be corrected to gain code compliance - - / `/ o-)-7 C� .✓ - ni At v Q You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ,;t� Call for re-inspection when corrections are made before continuing p Make corrections, items will be checked on next inspection This is not a complete inspection Department /9C-"e�-) Date g- F- Inspector -�72_ a nO NOT RFMOV ', THIS TArw ACCESS & GRADE WORKSHEET DATE: d i ADDRESS F 12 L(,,,p S LK /Zw INSPECTOR Z DRIVEWAY ACCESS Length: Width: 2 Surface: Size of turn-around: Condition of shoulders: / Vertical clearance: ) need post at end of driveway with reflective address numbers GRADE,OF DRIVEWAY % OF ROAD % ROAD ACCESS Length: Width: Surface: Condition: Vertical clearance: BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. ( LOT INSIDE SMZ, 4X4 FIRES ONLY. ( ) LOT INSIDE UGA, NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4X4 FIRES. REMARKS (continue remarks on back) RECEWL I� � a4lZ MASON COUNTY 0�e d,7, ;4, ��orti r 71-4-- R Muir Lodge LLC 3930 Alhambra Ave, Martinez, Ca, 94553, LWSON COUI,4 i 1 Phone: ( 925 ) 228 - 3308; Fax: ( 925 ) 370 - 7173 Folio # 170709171032 - Room 10 Guest Name JEFFREY AMES Check In Date 07/17/2009 Address 1150 PHILLIPS LA LAKE RD Check In Time 17:04:00 SHELTON, WA, 98584 Check Out Date 07/31/2009 Rental Charge Total Other Charges Amount Paid 07/17/09 55.00 1 American Express 07/17/09 423.5 07/18/09 55.00 ATM CARD 07/24/09 423.5 07/19/09 55.0 07/20/09 55.0 j 07/21/09 55.0 07/22/09 55.0 07/23/09 55.0 07/24/09 55.0 07/25/09 55.0 j 07/26/09 55.0 07/27/09 55.0 07/28/09 55.0 07/29/09 55.0 07/30/09 55.00 770.0 Transient Tax Local Tax 77.0 State Tax 0.00 77.0 I 847.0 0.00 847.00 Total Charges: 847.00 (Discount): 0.00 Guest Signature Amount Paid: 847.00 Date Balance: 0.00 Thank you for your stay with us. Please visit us again. we enjoyed having you here. CheckedIn By: Mukesh Checkedout By: Page: 1 / 1 Inspection Request Request taken by Time Date of Inspection Today's Date l� /V Date inspection requested " Name on permit Site address Permit number Q3 LE> a?00(ff — Q/ 9 3 Type of permit Telephone contact number & name Y «-'n 3G O - Type of Inspection: I-A6r0Ya qoe �Footing Wallboard s Foundation/Stem Final Other Slab insulation MH footing detail: b rough ' plum ' MH set-up i7NM `final �yn ulation oodstove/Gas stove �1 Kc. G lvs u✓e Confirm call back by �^ ate 0 Contacted e X 9/19/2013 Case Activity Listing , 9:21:28AM Case #: BLD2006-01931 Assig` Activity Description Date 1 Date 2 Date 3 Hold Disp T_ EE& Updated Updated By BLDA920 Miscellaneous Action 4/14/2008 None DONE CMH 4/14/2008 CMH Ryan Crater will be sending a letter to Mr.Eaton explaining that he must submit a new floor plan indicating conditions setforth in the Hearings Examiner Decision. New floor plans are pending. BLDA150 Revisions Approved for Iss. 6/3/2008 None DONE KS 6/3/2008 KS BLDA505 Issue Revisions 6/3/2008 None DONE KS 6/3/2008 KS BLDC140 Framing/Plumbing/Mechanical 7/10/2008 7/11/2008 None FAIL MAU 7/16/2008 KDM PLUMB/MECH APASSED BUT FRAME FAILED: 1)AS PER LAST C/N NEED TO COMPLETE#6 BEFORE OK TO INSULATE. #8,11,12,14 AND 15 ARE NOT COMPLETED. **CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE CONTINUING****OK TO INSULATE AFTER#6 IS COMPLETED. BLDC125 Framing Inspection 7/14/2008 7/15/2008 None FAIL BTA 7/16/2008 KDM OK TO INSULATE,#6 IS COMPLETED. BLDC145 Insulation Inspection 8/7/2008 8/8/2008 None FAIL TFR 8/11/2008 KDM AND DRYWALL: 1)#8-11-12-14-15 FROM FRAMING C/N DATED 2-22-08 NOT DONE. 2)NO INSULATION INSPECTION HAS BEEN DONE.PULL OFF 6-TX12'AREA FOR REVIEW ON DIFFERENT EXT WALL AND TWO 4'XIT AREAS ON CEILING. 3)PULL OFF DRY WALL IN BATHRM CEILING TO REVIEW ENGINEERS FIX FOR CANTILEVERED GLU-LAM 4)NO PLANS ONSITE,NO INSPECTION HAVE PLANS READILY AVAILABLE NEXT INSPECTION. 5)WINDOW BY D.W DOOR FIX PANE IS TEMPERED BRING SLIDER DOWN FROM V.W.BATHAND INSTALL D.S.AND ONLY UPSTAIR WILLNEED TEMPERED GLASSING IN BOTH PANES. **CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE CONTINUING****THIS IS NOT A COMPLETE INSPECTION"**DO NOT TAPE. BLDC145 Insulation Inspection 8/14/2008 8/15/2008 None PASS TFR 8/18/2008 KDM WALL AND CEILING.#11, 12, 14, 15 NOT DONE. BLDC105 Progress Inspection 2/3/2009 2/9/2009 None DONE MAU 2/10/2009 KKK BLDC250 Permit Extension 7/30/2009 8/9/2009 None EXTD PIB 12/10/2009 PIB Extended permit 6 months from 8-09-09 to 2-09-2010 per written request. He is working out of the area at this time. 9/19/2013 Case Activity Listing 9:21:28AM Case#: BLD2006-01931 11010 Assigned Done Activity Description Date 1 Date 2 Date 3 hold Disp To By Updated Updated By BLDC110 Footing Inspection 12/2/2009 12/4/2009 None PASS LDK 12/10/2009 PIB Footing/slab-Pass. Two locations-covered porch. BLDC125 Framing Inspection 4/12/2010 4/13/2010 None PASS TFR 4/14/2010 PIB BLDC105 Progress Inspection 4/4/2011 4/4/2011 None DONE PIB 5/1/2012 PIB Progress-Phone: worked on more of walls. BLDC100 Inspection 4/5/2011 4/6/2011 None FAIL TFR 4/7/2011 PIB Fire Wall-Fail: Only house wall done except in trusses-install studs at 16"o.c.and nail drywall to new studs(don't cover). BLDC105 Progress Inspection 10/4/2011 10/4/2011 None DONE KS KS 10/4/2011 KS FIREWALL TAPED/PAINTED BLDC105 Progress Inspection 4/4/2012 4/4/2012 None DONE PIB 5/1/2012 PIB Progress/Phone: Worked on more of walls. BLDC105 Progress Inspection 10/3/2012 10/3/2012 None DONE KS KS 10/3/2012 KS UPPER CONSTRUCTION ON FIREWALL "'BLDC105 Progress Inspection 3/29/2013 None DONE GMM 3/29/2013 G M M WORKING ON FRAME REPAIR AND TRUSS WALL SYSTEM Pine 7 of 7 CaseActiviiy..rpt 19/06/2007 11:13 1360-277-0486 P.S.PLUMBING PAGE 01 k SELBY DESIGN, LTD. 521 E. MASON BENSON RD GRAPEVIEW, WA. 98546 360.275-6550 FAX 360-277-0486 FACSIMILE TRANSMITTAL SHEET TO: '[t a&E�Z LcAk e_ DATE L Z - v 2 COMPAN)' MA'-smn Co - FAX: 1'<fc�` - �927 - 7 CC: -- PHONE: _ TOTAL NO PAGES R F _ �rf �CL�-- o! INCLUDING COV EK: T URGENT f FVIEW PLEASE COMMENT PLEASE REPLY NOTES: --- eL� l 12/06/2007 11: 13 1360-277-0486 P.S.PLUMBING PAGE 02 Hodgeinc. 12-5-2007 S7.1116B RE 1150 E Phillips Lake Rd: Shelton, WA I lodge Cng. Project 6.1193 Selby Design plan Ames Residence Tal' 2x6, Stud Wall To Whoo i It May Coilc efn: I have provided the lateral and gravity load engineering for the Selby Design plan Ames Res,idenre for Brian Ames. Per the bJildPr the wall separating the two garages will be about 22'-2"tall and is non bearing. Attached are calculations for the loading of the garage to 2x6 studs 22'-2" tall at 16" on cer-te, snowing that they are adequate for the axial loading. 2x6 22'--2' tall garage studs are acceptable for interior non bearing walls not exposed L: winr7 or floor or roof loads. See attached plan view of the area in question and calculations for 2x6 22'-2" tall studs a! 16" on center. The wall may be constructed having a 2x4 pony wall over as shown in the builder provided detaii attached. Please contact me with any questions regarding this project. R(p A.. ti 0. o m p O S/ONAti- 'EXPIRES: 12LI�5 This letter is the Professional opinion of the engineer of record and regards his engineering only. This letter does'not allow the hui'der to�diVrog,9rd Code requirements. Any schedule or cost impact is the responsibility of the bulldr�• ,,r-mner The Buildii6'Inspector has the final authority to allow field changes to approved build;ng pla!-!- 'ester may be signed electronically in accordance with WAC 196-23-070 and Chapter 19.34 RCVt ;;,()rT.!ri111�EI_a'.'/{.'1��"iyC,:�S Li[$' i�:►t-tJrl' t1 y<'';':'.,a :):IP =)7 70,j5 F-3X C 85.• ;)'lei 12/06/2007 11:13 1360-277-0486 P.S.PLUMBING PAGE 03 al 007 Version: 2 0 Designed : D�� Posts/Studsi and Desip Mow to Order Pro Developed by. Friar Dau Home Pont version Member# S1 ForuM Englineem Location : Front Entry Sits of",Sill Plate? yYes I Dimension Lumber" ••Dlmenslon Lumber" Nominal S-ze : f, t ) 2 x 6 Sill Plate Nominal Size: 2 x 8 Species = Hem-Flr Species or Symbol= Hem-Fir GiracP-= Stud Grade= No.2 Bearing at<3"of Sill End? No P Height(H) = 22 ft - 2 in H PM 200 lb - DL+SL Unbmoed Length r/,) = 22 ft - 2 in W W 0 Of = Wind IT Unbraoed Length (11) = 1 R - 0 In yy lu= 1 ft - 0 In Setup (pre,eed-down buttons are selected) Repetitive Use? Y�! Indeed for PT No � Max.Allowable P•12231b Fiat Use: No Moisture Content: `19% (or P only,fc(pal)= 24 C 140 ■ Fc I/ Temperature(-F) GO for P+w,fc(psi)- 24 C 150 - Fc 9 ! ' Cp = 1.15(P) b 1.60(P+w) fb(psi)- 0 C 986 - Fb Y -► K s 1.00 (fc!F'c)2 + fb/(Pb(1 -fe I Fce)) = 0.03 < 1.00 Stresses Chocked OK Section Properties Post/Stud Sill P)„ breadth(b) = 1,5 in 1.5 Adjustment Factor Sill PL depth(d) _ 15 in 5.5 jam r&W_I Area(A) = 3.3 In"2 8.3 Wet Service CM- 1.00 1.00 1.00 1.00 Section Modulus(S)_ '6 in^3 Temperature Ct= 1.00 1.00 1.00 1.00 Moment of Inertial 111 20 6 In44 Beam Stability CL- 0.99 NIA WA N/A Size CF- 1.00 1.00 WA WA Flat Use Co,= 1.00 N/A N/A NIA Design Values (pat) S/11 pL Incising C,W 1.00 1.00 1.00 1.00 Fk F SA Repeffth a#Aerobe► C,- 1.16 N/A WA NIA Tabulated !: S P00 1200000 405 Column Stability(P) Cp= N/A 0.18 N/A N/A Adjusted(P) 148 1200000 506 Column Stability(P+w) Cp.a N/A 0.12 WA N/A Adjusted(P+w) FM '50 12000M 5W Beefing Area Cb- WA N/A WA 1.25 12/06/2007 11:13 1360-277-0486 P.S.PLUMSING PAGE 04 rECEIVED 12/05/2007 11:29 2538577599 HODGE ENGINEERING 12/05/2007 It 1360-277-0406 P.S.PLLMBING PAGE 02 ..� 2k4 '.TrLAvS �a g� • ' c�w a �s�c. W P 35 f� �l✓I D cla t Kc, 1wr Wes► ^•, -1-pv�s s w e�s�� rp .l• .:a..+:i� '•r�+ cYCw.?.• -_,::_w:-�.a•. • : . : +..c: J• ice,.".., • _ ;�;��;� '• ..'•4:,i 1t":' vita`.;£3�rcif;i�+.'i,c:;4.:"�i +;. ,. ..r f7•�•i_S_ i _^:�._ .-' it•-.• :t' Ii � I ;� W P 3GGo 1Hf- �-i. WA.`- -pert Pt � � �. -ro Pa�v F 7�+�Tf•4`C� r.� �¢•O µ S CJ•r6 (M4Y. 7M Q 6plbesr-C., t G`04 6 Hodge engineering�+ inc. 7-17-08 Letter # 8487 RE. 1150 E Phillips Rd Hodge Eng. Project 6.1193 Selby Design plan Ames Residence Cut Glulam Beam To Whom It May Concern: I have provided the lateral and gravity load engineering for the Selby Design plan Ames Residence for Brian Ames. Per the builder Beam U7 (3-1/2"x11-7/8" Versa-Lam Beam) has been cut and scabbed together at the end to support the ends of the cantilevered floor joists as shown in the attached plan view. As a fix the builder shall add 6x6 DF#2 beam, Beam U1O cut in under the existing beams bearing on the outside foundation wall and internal thickened footing of the bathroom wall. The 6x6 shall be attached to the cut beam with ST9 straps either side. See attached plan view of the area in question and beam calculations. Please cont t m 'th any questions regarding this project. w 7-17-08 ti Letter#' tTi r- 885TEn"- SSl�NAL�yCs John Hodge _. 121101 .F Hodge Engineering, :Inc. John E. Hodge P. E. 2601 Jahn Ave NW Ste. Ax.Gig Harbor, WA 98335 (253)857-7055 Fax(2s3)857-7599 or 4x10 DF*2 U.N.O u5 �1 UNDISTURBED SOIL 4"AO"OF02 1 r - U1 0 - UP U .EVER JOISTS • UI o 1312 O x 11 Rl x 4"x8"DM i i v 4'xS'DFn R� x8 D RS U4 4NIO'DFn41 z D1 � r ,t utj 2 ENGINEERED TRUSSES @ 24" O.C. D1 COMPANY PROJECT Brian Ames Hq�4ge Ames residence 1150 E.Phillips Lake Rd. eI1Cjinn. 30 psf snow load July 17,2008 13:30 U10-Added 7-17-08 Design Check Calculation Sheet Sizer 8.0 LOADS: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Loadl Dead Full Area 10.00 (4.50)* psf Load2 Snow Full Area 40.00 (4.50)* psf *Tributary Width (ft) MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : 10, 5( Dead 112 112 Live 450 450 Total 584 584 Bearing: Load Comb #2 #2 Length 0.50* 0.50* Cb 1.00 1.00 *Min. bearing length for beams is 1/2"for exterior supports Lumber-soft, D.Fir-L, No.2, 6x6" Self-weight of 8.55 plf included in loads, Lateral support:top=at supports,bottom=at supports; WARNING:this CUSTOM SIZE is not in the database. Refer to online help. Analysis vs.Allowable Stress (psi) and Deflection (in) using NDS 2005: Criterion Analysis Value Design Value Analysis/Design Shear fv = 19 Fv' = 207 fv Fv' = 0.09 Bending(+) fb = 243 Fb' = 1035 fb/Fb' = 0.24 Live Defl'n 0.01 = <L/999 0.17 = L/360 0.09 Total Defl'n 0.02 = <L/999 0.25 = L/240 0.08 ADDITIONAL DATA: FACTORS: F/E CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 900 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 2 Emin' 0.00 million 1.00 1.00 - - - - 1.00 1.00 - 2 Shear : LC #2 = D+S, V = 584, V design = 467 lbs Bending(+) : LC #2 = D+S, M = 730 lbs-ft Deflection: LC #2 = D+S EI = 173e06 lb-in2 Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow W=wind I=impact C=construction Lc=concentrated) (All LC's are listed in the Analysis output) Load combinations: ICC-IBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. Case Activity Listing 4/19/2018 12:22:36PM I rot Case#: BLD2006-01931 Parcel #: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE"(EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activity Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By BLDA010 Application Received 10/31/2006 10/31/2006 None DONE KKK 10/31/2006 KKK BLDB200 Environmental Health Review 10/31/2006 I1/2/2006 None DONE TW 11/2/2006 TW BLDB110 Building Plan Review 10/31/2006 11/2/2006 None DONE JRN 11/2/2006 JRN review complete,sent to case manager.JRN 11-02-06 BLDB120 WSEC Compliance Review 11/2/2006 None DONE JRN 11/2/2006 JRN review complete,electric wall heaters,2004 WSEC path option IV,JRN 11-02-06 BLD13009 Fire Marshal Review 11/6/2006 11/6/2006 None DONE DHS 11/6/2006 DHS BLDB130 Planning Review 10/31/2006 11/21/2006 None DONE KJR KJR 11/21/2006 KJR BLDA100 Approved for Issuance 11/27/2006 None DONE CMH 11/27/2006 CMH NOTIFIED APPLICANT BLDA500 Issue Building Permit 11/27/2006 None DONE KKK 11/27/2006 KKK BLDA540 Print Inspection Card 11/27/2006 None DONE KKK 11/27/2006 KKK BLDA500 Issue Building Permit 11/27/2006 None DONE KKK 11/27/2006 KKK Page 1 of 8 CaseActivity..rpt Case Activity Listing 4/1 12 /2018 li Case #: BLD2006-01931 i Parcel #: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED "LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1 909982) Assigned Done —� Activity Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By BLDA990 Plot Plan Revision Received 5/16/2007 None DONE GMM 5/16/2007 GMM Revision turned in to move the new portion 5'to the East and the original portion F to the east still sitting on the original foundation. BLDB410 Planning Review Revision 5/16/2007 5/22/2007 None DONE KJR KJR 5/22/2007 KJR BLDB420 EH Review Revision 5/25/2007 6/1/2007 None DONE TW 6/1/2007 CMH REVISION WAS 5 FEET TO SIDE OF PROPERTY ONLY. WILL HAVE NO IMPACT ON DRAINFIELD. CMH BLDA510 Reprint Building Permit 6/1/2007 None DONE CMH 6/1/2007 CMH FIRST PAGE FOR SITE PLAN REVISION BLDC100 Inspection 6/1/2007 6/6/2007 None PASS TFR 6/12/2007 MRB SETBACK/FIRST 4/5 OF FOOTING WITH STEMWALL PASS BELOW GRADE DWV PASS W/COND 1.ALL DWV EXPOSED TO CONCRETE ON HORIZONTAL REQUIRED SLEEVE 2.COVER REST WITH PEA GRAVEL 3.OK TO FIX PHOTO AND PROCEED BLDC 110 Footing Inspection 7/3/2007 7/3/2007 None PASS BTA 7/5/2007 MRB BLDB007 Plan Revisions Submitted 9/6/2007 None DONE GMM 9/6/2007 GMM owner came in requesting a revision to change storage area to living space.the original plan due show the living space area. The total sq. ft. is 1061. The new living space will not have a cooking stove. BLDB201 More Info Letter-EH 9/10/2007 None DONE TW 9/10/2007 TW THIS PROPOSED CHANGE EFFECTS THE OCCUPANCY ON THE SEPTIC SYSTEM.AT MIN.THIS WOULD BE CONSIDERED AN ADDITIONAL BEDROOM.PLEASE ADDRESS BLDB 155 Letter of Incompleteness 10/30/2007 None DONE REC 10/30/2007 REC You have submitted a request for a site plan revision of which you have changed a portion of your garage to living space. Due to this change and it's intended use your request will require you to apply for a special use permit for an Accessory Dwelling Unit. Attached you will find an Application for Special Use and the requirements for an Accessory Dwelling Unit. Please fill out the application and submit it to the permit assistance center. If you have any questions give me a call. BLDA600 File Possession 11/2/2007 11/2/2007 None DONE TAM 11/2/2007 TAM File brought to planning for Barb to review. Page 2 of 8 CaseActivity..rpt r Case Activity Listing 4/19/2018 12:22:36PM Case#: BLD2006-01931 Parcel#: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By BLDA800 Documents Received 11/19/2007 None DONE TAM 11/21/2007 1AM Floor Flan has been revised to show building use as garage/hobby room.Made copies for all departments and distributed.Applicant is continuing with ADU process-see DDR 2007-00334. BLDA920 Miscellaneous Action 11/21/2007 None DONE TAM 11/21/2007 TAM REVISION SHEET DISTRIBUTED FOR SIGNATURES FOR APPROVAL OF GAME ROOM/RECREATION USE OF THE LIVING AREA BLDA900 Telephone Call 11/21/2007 None DONE DLC 11/21/2007 DLC Spoke with Mr.Brian Ames concerning proposed fire wall shown on the revised plans dated 11/16/2007. The section designated as a"U"occupancy will be used for agricultural purposes and may exceed 3000 sf but shall be separated from the the R3 occupancy with a 1-hour assembly(see 2003 IBC Chapter 3). The revised plans do not identify fire wall compliance relating to penetrations and continuity,see IBC Section 705. Requested that assembly details be provided demonstrating intended compliance as required in section 705. Note that if the U occupancy is identified as a garage,used for the storage of private or pleasure-type motor vehicles. A group U occupancy shall be permitted to be in the same building provided each 3000 sf area is separated by fire walls complying with 2003 IBC Section 706(IBC 406.1.2). The fire resistive rating for fire barriers in a"U"occupancy shall have a rating of 1-hour or better and be installed in accordance to Section 706,including continuity,opening&penetration protection. Mr.Ames stated that he will arrange to have his wife come in to pick-up information and deliver to designer. d coker 11/21/2007 Mrs.Ames came in immediately and picked up approved site plans and and revised plans dated 11/16/2007. do BLDA900 Telephone Call 11/1/2007 None DONE MAL 11/30/2007 MAL Spoke with Brian regarding the need for firewall specifications. He informed me that he had turned in a revised set of plans that was not in my possession. I located the plans and returned a call to him indicating this. I also left message that I would keep the plan on hold until I had information about the planning requirements for size of the ADU. Currently there is over 1600 sq ft in the proposed area on 2 separate floors.MAL 11/01/2007 also indicated to him during this conversation that we would still need the details for the firewall from the designer to make it continuous from floor to roof sheeting and wall to wall. BLDA910 Meeting 11/21/2007 None DONE MAL 11/30/2007 MAL Met with Mrs.Brian Ames to discuss the firewall requirements for the separation of the Ag building from the proposed residential area of this structure. A general indication of a one hour wall was made on a plan submitted for revision. I had previously told Mr.Ames that we would need the wall design and corresponding details for continuity of that assembly. When Mrs.Ames was in we spoke at length so that she could understand exactly why this separation was required and what type of details that we would need. She took notes and was given copies of numerous code sections. She thanked me for the explanations and said"now I understand what is being asked for." She said that she would go back to the designer to try to get that information for submittal. MAL 11/21/2007 Page 3 of 8 CaseActivity..rpt Case Activity Listing 4/19/2018 12:22:36PM Case #: BLD2006-01931 Parcel #: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By BLDA900 Telephone Call 11/29/2007 None DONE MAL 11/30/2007 MAL Spoke with Tammy Selby about the firewall requirements. She was unable to locate details that would provide continuity through the floor system(engineered I joists penetrating through the area requiring separation). I informed her that I had no such details that I could provide or had I seen any tested assemblies. After much discussion she decided that it would be far easier to separate the"U"occupancies with a firewall and provide the modified separation allowed between the private garage(adjusted to<3000 sq ft)and the residential portion. After our call I realized that during our discussion I was quoting the 2006 code regarding the 2hr requirement between the U occ's. I phoned back and left message on her machine that per the code for this plan(2003)the requirement was only I hour. I also mentioned some ideas for the creation of the sep.at the private garage/res.wall that would need to include 5/8 rock on horiz.members in the assembly and 1/2 on any supporting walls. MAL 11/29/20071 also suggested during this conversation that an architect or engineer that did commercial work may be able to provide some details for these assemblies. BLDA900 Telephone Call 11/29/2007 None DONE MAL 11/30/2007 MAL Met with Barb Robinson to review the status of the Ames project. Following the meeting I called the designer(Tammy Selby)to discuss the details needed for the fire separation that is required for this project. She said that she had met with Mrs.Ames following the meeting that took place at Mason County permit center on 11/21/2007. I spoke with her about the area in question and mentioned that there was engineering involved with the wall and that the engineer of record should be consulted about the changes and or additions that may need to be done to this wall. I also said that any changes would need to be approved by the engineer anyway so she may want to consult with them about the fire wall details also. Tammy Selby said that she would do that. I am awaiting details for the fire separation from the designer and/or engineer to complete the building revision review. MAL 11/29/2007 BLDA900 Telephone Call 11/30/2007 None DONE MAL 11/30/2007 MAL Spoke with designer regarding plan for firewalls. She is working with the engineer for the 1 hour wall to divide the U occupancies and designing a system for the garage house separation. She asked about the area above the new wall we discussed an option to protect the truss(I said I would need the detail and truss engineers approval for any modifications),she mentioned that they may do a 2x4 wall along side and I said that would require the structural engineers approval to be stacked on his engineered wall. MAL 11/30/2007 BLDA008 Issued-No Print 12/4/2007 None DONE KS 12/4/2007 KS BLDA510 Reprint Building Permit 12/4/2007 None DONE KS 12/4/2007 KS BLDA800 Documents Received 12/6/2007 None DONE MAL 12/6/2007 MAL engineering received for firewall,added to inspector file MAL 12/06/2007 BLDM200 Freeze Case 2/25/2008 None DONE REC 2/25/2008 REC Do not issue permit or a final. See Planning. Page 4 of 8 CaseActivity..rpt Case Activity Listing 4/19/2018 12:22:36PM Case #: BLD2006-01931 Parcel#: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLYAF#1909982) Assigned Done Activity Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By BLDC140 Framing/Plumbing/Mechanical 2/19/2007 2/22/2008 None FAIL BTA 2/26/2008 MRB 1.INSTALL EXHAUST FAN IN UNDERSTAIRS BATHROOM 2.COMPLETE INT WALL AT UPSTAIRS BATH DIVIDING FROM BELOW 3.ADD GAS FIREPLACE TO PERMIT 4.ADD LP GASS OUTLETS TO PERMIT 5.INSTALL SMOKE DECTORS ON EACH FLOOR 6.INSTALL CAULK AND SEAL PACK ALL TOP AND BOTTOM PLATE PENETRATIONS AND HORIZONTALLY 10' OC 7.ADD GAS WATER HEATER TO PERMIT 8. 1ST FLOOR WINDOW EAST SIDE BY DOOR NEEDS TO BE TEMPERED 9.COMPLETE ELECTRICAL WITH L&I SIGN OFF BOTH BOXES 10.DOWNSTAIRS EXHASUT MUST REMAIN 4"TO EXT 11.HAVE ENGINEER ADDRESS CANTILEVERD GLULAM 12.GARAGE PORTION OF TRUSSES REQUIRE 10'OC BRACING OR RIGID CEILINGS 13.WASHERS OVER ANCHOR BOLTS TO BE 3" 14.MID GARAGE INT WALL IS MISSING 15.UPSTAIRS BATH REQUIRES TEMEPERED WINDOW ON TUB 1/2 OF WINDOW 16.INSTALL NAILPLATE AT 1 ST FLOOR TOP PLATE SUPPLY PENETRATION CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE CONTINUING BLDM200 Freeze Case 2/26/2008 None MRB 2/26/2008 MRB BLDM300 UnFreeze Case 3/17/2008 None DONE REC 4/3/2008 REC Hearings Examiner approved request for reconsideration. Two new conditions added onto the project. See Hearings Examiners decision in case DDR2007-00334 under letter attached dated 3/17/08. REC. Ready to issue permits.4/3/08 REC. BLDA920 Miscellaneous Action 4/14/2008 None DONE CMH 4/14/2008 CMH Ryan Crater will be sending a letter to Mr.Eaton explaining that he must submit a new floor plan indicating conditions setforth in the Hearings Examiner Decision. New floor plans are pending. BLDB400 Building Review Revision 10/31/2007 12/4/2007 None HOLD MAL MAL 4/14/2008 MAL New requirements of hearing examiner must be added to plan and site copy returned for revision. See misc.action of 4/14/2008 MAL Review complete(some details not complete at this time but expedited per owner request)and sent to case manager. Per conversations,with owner and designer,engineering to support any/all changes will be onsite by the time of inspections. MAL 12/04/2007 04-14-2008-Ryan Crater will be sending out a letter to applicant asking for a new floor plan showing recommendations as setforth in decision of Hearings Examiner. -cmh Please see phone calls regarding plan review for further info MAL 11/30/2007 Please see meeting and telephone notes regarding this review process. MAL 11/29/2007 awaiting information on ADU requirements. MAL 11/01/2007 11/21/2007: See telpehone notes dated H/21/2007-do BLDA150 Revisions Approved for Iss. 6/3/2008 None DONE KS 6/3/2008 KS Page 5 of 8 CaseActivity..rpt 4/19/2018 Case Activity Listing 12:22:36PM Case#: BLD2006-01931 Parcel#: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTILAPPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activitv Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By BLDA505 Issue Revisions 6/3/2008 None DONE KS 6/3/2008 KS BLDB410 Planning Review Revision 9/10/2007 9/19/2007 None DONE REC REC 6/24/2008 REC Plans dated June 19,2008 approved. 6-24-08 REC. Hearings Examiner approved structure for use as an accessory dwelling unit. 4/15/08 REC. Hearings Examiner approved request for reconsideration. Two new conditions see attached letter dated 3/17/08 in the date file.3/17/08 ItEC. The Hearings Examiner denies the requested Special Use Permit for DDR2007-00334 2/25/08 REC. Hearing for ADU on Jan 22. REC. Needs to go through an accessory dwelling unit process. Cannot approve without going through a hearing process. BLDC125 Framing Inspection 7/14/2008 7/15/2008 None FAIL BTA 7/16/2008 KDM OK TO INSULATE,#6 IS COMPLETED. BLDC140 Framing/Plumbing/Mechanical 7/10/2008 7/11/2008 None FAIL MAU 7/16/2008 KDM PLUMB/MECH APASSED BUT FRAME FAILED: 1)AS PER LAST CM NEED TO COMPLETE#6 BEFORE OK TO INSULATE. #8,11,12,14 AND 15 ARE NOT COMPLETED. **CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE CONTINUING****OK TO INSULATE AFTER#6 IS COMPLETED. BLDC145 Insulation Inspection 8/7/2008 8/8/2008 None FAIL TFR 8/11/2008 KDM AND DRYWALL: 1)#8-11-12-14-15 FROM FRAMING CM DATED 2-22-08 NOT DONE. 2)NO INSULATION INSPECTION HAS BEEN DONE.PULL OFF 6-4'XIT AREA FOR REVIEW ON DIFFERENT EXT WALL AND TWO 4'XIT AREAS ON CEILING. 3)PULL OFF DRY WALL IN BATHRM CEILING TO REVIEW ENGINEERS FIX FOR CANTILEVERED GLU-LAM 4)NO PLANS ONSITE,NO INSPECTION HAVE PLANS READILY AVAILABLE NEXT INSPECTION. 5)WINDOW BY D.W DOOR FIX PANE IS TEMPERED BRING SLIDER DOWN FROM V.W.BATHAND INSTALL D.S.AND ONLY UPSTAIR WILLNEED TEMPERED GLASSING IN BOTH PANES. **CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE CONTINUING****THIS IS NOT A COMPLETE INSPECTION****DO NOT TAPE. BLDC145 Insulation Inspection 8/14/2008 8/15/2008 None PASS TFR 8/18/2008 KDM WALL AND CEILING.#11, 12, 14, 15 NOT DONE. Page 6 of 8 CaseActivity..rpt Case Activity Listing4/19/2018 12:22:36PM Case#: BLD2006-01931 Parcel #: 221325100012 Not Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTIL APPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By BLDC105 Progress Inspection 2/3/2009 2/9/2009 None DONE MAU 2/10/2009 KKK BLDC110 Footing Inspection 12/2/2009 12/4/2009 None PASS LDK 12/10/2009 PIB Footing/slab-Pass. Two locations-covered porch. BLDC250 Permit Extension 7/30/2009 8/9/2009 None EXTD PIB 12/10/2009 PIB Extended permit 6 months from 8-09-09 to 2-09-2010 per written request. He is working out of the area at this time. BLDC125 Framing Inspection 4/12/2010 4/13/2010 None PASS TFR 4/14/2010 PIB BLDB420 EH Review Revision 9/6/2007 11/20/2007 None DONE TW TW 3/17/2011 CEW 09.10.07 THIS PROPOSED CHANGE EFFECTS THE OCCUPANCY ON THE SEPTIC SYSTEM.AT MIN.THIS WOULD BE CONSIDERED AN ADDITIONAL BEDROOM.PLEASE ADDRESS 11.20.07 FLOOR PLAN OF EXISTING UNIT 2 BEDROOM,UNIT ABOVE GARAGE-1 BEDROOM SEE AF# 1909982 BLDC100 Inspection 4/5/2011 4/6/2011 None FAIL TFR 4/7/2011 PIB Fire Wall-Fail: Only house wall done except in trusses-install studs at 16"o.c.and nail drywall to new studs(don't cover). BLDC105 Progress Inspection 10/4/2011 10/4/2011 None DONE KS KS 10/4/2011 KS FIREWALL TAPED/PAINTED BLDC105 Progress Inspection 4/4/2011 4/4/2011 None DONE PIB 5/1/2012 PIB Progress-Phone: worked on more of walls. BLDC105 Progress Inspection 4/4/2012 4/4/2012 None DONE PIB 5/1/2012 PIB Progress/Phone: Worked on more of walls. BLDC105 Progress Inspection 10/3/2012 10/3/2012 None DONE KS KS 10/3/2012 KS UPPER CONSTRUCTION ON FIREWALL Page 7 of 8 CaseActivity-rpt /2018 Case Activity Listing 124/1936PM Case #: BLD2006-01931 Parcel #: 221325100012 Description: Garage/Ag. Building REVISED LIVING SPACE WITHIN GARAGE WILL BE USED FOR GAME ROOM AND RECREATION AREA UNTILAPPROVED FOR ADU 11.20.07 REVISED ADDED"LIVING SPACE" (EXISTING HOME 2 BEDROOM ADDITIONAL LIVING SPACE OVER GARAGE-1 BEDROOM ONLY AF#1909982) Assigned Done Activitv Description Date I Date 2 Date 3 Hold Disp To By Updated Updated By, BLDC105 Progress Inspection 3/29/2013 None DONE GMM 3/29/2013 GMM WORKING ON FRAME REPAIR AND TRUSS WALL SYSTEM BLDC125 Framing Inspection 9/19/2013 9/26/2013 None PASS TFR 9/30/2013 PIB Covered Entries Framing-Pass. Cond-both proched deed step flashing to building with a 1 X4 over too and caulking. BLDC105 Progress Inspection 3/25/2014 3/26/2014 None DONE PIB 3/25/2014 PIB Progress/Phone: Firewall framing. BLDC105 Progress Inspection 9/23/2014 9/23/2014 None DONE AMP 9/23/2014 AMP Progress over the phone:Truss updates for firewall BLDC105 Progress Inspection 3/20/2015 3/20/2015 None DONE AMP 3/20/2015 AMP Progress/Phone:Per owner working on truss renforcments for firewall BLDC105 Progress Inspection 9/14/2015 None DONE AMP 9/14/2015 AMP Progress/Phone:Firewall door installed. BLDC105 Progress Inspection 4/13/2016 None DONE AMP 4/13/2016 AMP Progress/Phone:Fire wall truss blocks to roof have been repaired. BLDC100 Inspection 10/11/2016 10/14/2016 None PASS SLC 10/14/2016 MLW FIRE DOOR:90 MIN.ASST.DBL.DOOR BLDC105 Progress Inspection 4/7/2017 None DONE JAK 4/7/2017 JAK STILL WORKING,SHOULD BE READY FOR INSPECTION WITHIN NEXT 6 MOS BLDC105 Progress Inspection 10/11/2017 10/11/2017 None DONE MLW 10/11/2017 MLW Progress Over the Phone:Upper truss stiffners to the firewall Page 8 of 8 CaseActivity..rpt