HomeMy WebLinkAboutBLD2006-01517 Cancelled Garage - BLD Permit / Conditions - 2/22/2021 Inspection Line(360)427-7262
NoMASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton,WA 98584
t
RESIDENTIAL BUILDING PERMIT BLD2006-01517
OWNER: LANNY ZWAN RECEIVED: 8/24/2006
CONTRACTOR: LICENSE: EXP: MSSUED: 10/6/2006
SITE ADDRESS: 2121 NE BLACKSMITH DR BELFAIR EXPIRES: 4/6/2007
PARCEL NUMBER: 223107600350
LEGAL DESCRIPTION: TR 35 OF SURVEY 10/102 (NW SW)
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
GARAGE W/ PLUMBING (Unheated, single story) West on Bear Creek Dewatto Rd. to Blacksmith Dr., South on Blacksmith Dr. to
end of road.
General Information Construction &Occup InifiLmajon Square Footage Information
No. of Bedrooms: 0 0
Type of Use: SF Insp.Area: No.of Bathrooms: 1 ro Lot Size: Deck:
Type of Work: ACC Fire Dist.: 2 No. of Stories: 1 Building: Garage-Detached 1,144
Valuation: Building Height: atus: PrimaryBasement:
Manufactured Home Information t In ation Shoreline& Planning Information
Make: Length: Ft. Ce
: Shoreline: Ft.
Water Body:
: E 0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Shoreline Desig.: Not Applicable
: 32.0 Ft.
Year: Serial No.: S Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Lavatories 1 Ventilation Fan 1 Plan Check Fee KKK 8/24/2006 $274.01 B12006000
Water Closets (Toilets) 1 Planning Review Fee KKK 8/24/2006 $155.00 612006000
Water Heaters 1 EH Plan Review TW 9/12/2006 $35.00 S12006000
Building State Fee DLC 9/20/2006 $4.50 S12006000
Building Permit Fee DLC 9/20/2006 $421.55 S12006000
Mechanical Fee DLC 9/20/2006 $7.25 S12006000
Mechanical Base Fee DLC 9/20/2006 $23.50 S12006000
Plumbing Fee DLC 9/20/2006 $21.00 S12006000
Plumbing Base Fee DLC 9/20/2006 $20.00 S12006000
Total $961.81
BLD2006-01517 Please referto the fo!iowing pages for conditions of this permit. 1 of 5
CASE NOTES FOR
BLD2006-01517
CONDITIONS FOR
BLD2006-01517
1) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. Xc- /'
J
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800- 7 :She person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X c-
3) Appro3ed.a r i ensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted, fo i addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Depahko rio�,to any further inspections being performed or approvals granted.
X �—< f--
5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that
require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the
access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background.
Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted
by the juris Tfti and—it— international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting
inspectio ))
X MZK
6) The plan review check and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of ap o ? R ents will result in failure of required building inspections.
X
7) This structure is.apprqued as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit shall sappy reviewed and approved prior to the change.
X
BLD2006-01517 Please referto the following pages for conditions of this permit. 2 of 5
8) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then
approval 4=1 Fb granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building t�rior to any further inspections being performed or approvals granted.
X
9) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum wi.2d loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609
BASIC WI D (3-SECOND GUST)the wind speed for Mason County is 85 MPH.
X
10) Per 2003 IRC_-_S TION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in
accordance plicable provisions of this section and the manufacturer's installation instructions.
X
11) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical co erete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X /
12) This structureis._limited_to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international 'Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved.
X
13) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Wa in t,�Sn�;Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revo 'a n.
X 1
14) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be I a wittlin;25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.'.`
X
15) All changes to "a iS-J- � uilcAng plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or reguii mu be reviewed and approved by Mason County prior to construction.
BLD2006-01517 Please refer to the following pages for conditions of this permit. 3 of 5
16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the internatiQ. al codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector. �e'rrade prior to requesting additional inspections.
X
17) All property lines shall be clearly identified at the time of foundation inspection. X
18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason Count dices and building regulations.
X
19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period t-expeeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have 6 ac&n from being taken. No more than one extension may be granted.
X
20) Pressure treated wood' anufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors , d,fl`ash�g. Install metal connectors approved for contact with the new types of pressure treated material.
X i
r
21) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved
access road._Roa" required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roads a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
X
22) Water qualit s e degraded to the detriment of the aquatic environment as a result of this project.
X
23) Prior to final approva , all upland areas disturbed or n d by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X
24) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure
these str4ztures meet the setback conditions listed.
X /
25) Landings an tail must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved '\o ensure these structures are shown and meet the setback conditions listed.
X
BLD2006-01517 Please referto the following pages for conditions of this permit. 4 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
.work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described prop a sVv6 re for review and inspection.
OWNER OR AGENT: yc DATE:
BLD2006-01517 Please refer to the following pages for conditions of this permit. 5 of 5
Case Activity Listing 1/28/2015
3:10:50PM
Case#: BLD2006-01517
IF,
Assigned Done
Activity Description Date 1 Date 2 Date 3 hold Disp To By Updated Updated By
BLDA010 Application Received 8/24/2006 8/31/2006 None DONE KKK 8/31/2006 KKK
BLDB200 Environmental Health Review 8/31/2006 9/12/2006 None DONE TW 9/12/2006 TW
CONDITIONED
BLDB110 Building Plan Review 8/31/2006 9/20/2006 None DONE DLC DLC 9/20/2006 DLC
The following letter was prepared for mail on 9/8/2006:
Dear Mr.Zwan,
Thank you for submitting the building permit application referenced above. In order to complete the building department review additional information will be needed which is listed below. When you
have compiled the requested information please submit it to the Mason County Building Department,attention D.Coker.
PLAN REVIEW REQUIREMENT COMMENTS:
1.Sheet 2 of the building plans state that storage trusses will be used for the roof. A floor plan,drawn to scale,showing the use of the area is required. In addition when the upper floor exceeds 200-sq.ft.an
exit stairway is required. I did not see a stairway on the building plans.
2.The building is considered a 2-story structure with storage trusses. Referencing Table R602.10.1 of the 2003 International Residential Code,walls with a floor above shall have 55%of the exterior walls
braced when the structure is located in seismic zone D2. The wall with two overhead doors is 26'0"long;the wall must have at least 14'4"of braced wall. When the amount and location of bracing does not
meet the minimum requirements that portion shall be designed by a Washington state licensed design professional in accordance with accepted engineering practice as specified in Chapter 16 of the
International Building Code.
To complete an engineered analysis your design professional will need the following information:
Snow load: 25 psf
Wind load: 85 mph,exp"B"
Seismic zone: D2
When you have compiled the requested information return two sets of revised building plans and 2 sets of calculations. If you have questions please contact me at(360)427-9670 ext.510 or via e-mail at:
dlc@co.mason.wa.us
BLDB130 Planning Review 8/31/2006 9/25/2006 None DONE CMM CMM 9/25/2006 CMM
Site visit 9/22/06. No issues.
BLDA100 Approved for Issuance 9/27/2006 None DONE CMH 9/27/2006 CMH
Page 1 of 4 CaseActivity..rpt
Case Activity Listing 1/28/2015
3:10:50PM
Case#: BLD2006-01517
i
Assigned Done
Activity Description Date I Date 2 Date 3 hold Disp To By Updated Updated By
BLDA500 Issue Building Permit 10/6/2006 None DONE KS 10/6/2006 KS
BLDA540 Print Inspection Card 10/6/2006 None DONE KS 10/6/2006 KS
BLDC105 Progress Inspection 1/17/2007 1/17/2007 None DONE RLS 1/23/2007 MRB
FOOTING DUG OUT
BLDC110 Footing Inspection 7/11/2007 7/17/2007 None PASS TFR 7/18/2007 MRB
SETBACKS/EXT FOOTINGS
BLDC105 Progress Inspection 1/8/2008 1/1 1/2008 None FAIL BTA 1/14/2008 KDM
foundation wall framing about complete
BLDC115 Foundation Wall Inspection 7/9/2008 7/11/2008 None PASS TFR 7/15/2008 KDM
DWV THRU-STEMWALL @ OWN RISK,NO TEST
BLDC120 Underground Plumbing 7/18/2008 7/21/2008 None COND TFR 7/22/2008 KDM
ONLY T OF HEAD TEST OK TO POUR @ OWN RISK.
BLDC105 Progress Inspection 1/6/2009 1/7/2009 None PASS TFR 1/8/2009 KKK
BLDC120 Underground Plumbing 6/30/2009 7/1/2009 None PASS TFR 7/8/2009 PIB
test passed.
BLDB007 Plan Revisions Submitted 7/9/2009 None DONE GMM 7/9/2009 GMM
Property owner submitted revision to add an additional 4'to the front for the detached garage.
BLDB410 Planning Review Revision 7/9/2009 7/9/2009 None DONE GMM 7/9/2009 GMM
Revision was not sent to planning,the additional 4'on the garage will still be within the approved setbacks
Page 2 of 4 CaseActivity..rpt
Case Activity Listing1/28/2015
3:10:50PM
Case#: BLD2006-01517
i
Assigned Done
Activity Description Date I Date 2 Date 3 hold Disp To By Updated Updated By
BLDB400 Building Review Revision 7/9/2009 7/17/2009 None DONE DLC 7/17/2009 DLC
Add 4'to front of garage(4'x26')
BLDA150 Revisions Approved for Iss. 7/23/2009 None DONE GMM 7/23/2009 GMM
CALLED AND TALKED WITH MR ZWAN LET HIM KNOW THAT THE REVISION IS DONE,ALSO GAVE HIM REMAINING AMOUNT DUE.
BLDC 110 Footing Inspection 7/28/2009 7/29/2009 None PASS TFR 8/3/2009 PIB
BLDC115 Foundation Wall Inspection 8/24/2009 8/27/2009 None PASS TFR 9/1/2009 PIB
garage extension
BLDC105 Progress Inspection 7/27/2010 7/27/2010 None DONE TW 7/27/2010 TW
plumbing not quite done.
BLDC105 Progress Inspection 1/27/2011 1/27/2011 None DONE PIB 2/11/2011 PIB
Phone: Installed doors
BLDC105 Progress Inspection 7/26/2011 8/2/2011 None PASS TFR TFR 8/3/2011 KS
FRAMED,ROOFED,TYVEKED,DOORS AND WINDOWS 1
BLDC105 Progress Inspection 1/30/2012 2/2/2012 None DONE PIB 2/3/2012 PIB
Phone: Holes drilled for wiring.
BLDC105 Progress Inspection 8/1/2012 8/1/2012 None DONE KS KS 8/1/2012 KS
DOING ELECTRICAL
BLDC105 Progress Inspection 2/1/2013 2/1/2013 None DONE KS KS 2/1/2013 KS
MORE ELECTRICAL AND BLOCKING CEILING JOISTS
BLDC130 Plumbing Inspection 7/31/2013 8/5/2013 None PASS TFR 8/6/2013 PIB
Heads Up: On back of electrical permit for framing inspection-draft stop at top plate penetration and 10'o.c.horizontal-provide wet stamped truss engineering-fill holes in truss,clips to plates and truss.
Page 3 of 4 CaseActivity..rpt
Case Activity Listing 1/28/2015
3:10:50PM
Case #: BLD2006-01517
P14
Assigned Done
Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By
BLDC105 Progress Inspection 1/31/2014 2/5/2014 None DONE PIB 1/31/2014 Pla
Progress/Phone: Putting in ventilation fan in bathroom.
BLDC 105 Progress Inspection 8/1/2014 8/1/2014 None DONE MK W 8/1/2014 M K W
Working on electrical and putting the siding on.Explained next inspection would need to be an onsite progress inspection. Asked him to contact us before the end of another six-month period of time.
Page 4 of 4 CaseActivity..rpt
CQNCRETE Gas Piping MANUFACTURED HOME
-- Irztiarbr-Date By
Footings 1 Setbacks axtemr_Hate Dy Ribbons
Date By INSULATION Data
Fourt.dation Watts 3G I SLAB 3 NSU LATi ON set-Up
Date By date By hate By
FRAMING
Firs FIRE DEPARTMENT
Clato E!, Eote DY
Date via tis DECKS
PLUMBING Date Date By
vault
amundwark TANKS
Date By Date, By
Date By A,ttic
Oate By
€3TI`i,ER
Type.
Date BY DRYWALL Date By
WzterLine Date BY Type,
Date By Int,Brace Wa Date By
MECHANICAL tes���s� BY FINAL INSPECTION
Fimt7s.te Qyy Date By Date By
Pass or Request Inspect,
Type of Insp. EaII Date DatO pone By Comments
�irw k
s
t
r
1
I
l
o CONCRETE MECHANICAL10 MANUFACTURED HOME
Date
rn Footings I Setbacks Gas Piping By Ribbons ----
o lrttedor Date /' By Interior-Date By Date By r
vExterior Date/ ..ems 8y Exterior-Date By set-up Z
Point toad I Isolated Footings INSULATION _ oats g Z
Date By BG I SLAB INSULATIONy �
Data By FIRE DEPARTMENT
Foundation Wallis '.i_� / � Floors Date By
Date By 1-1-72 Data By DECKS
FRAMING Wads Date By
Date By Data By PROPANE TANKS
PLUMBING vault Date By
Date By
Groundwork Arc OTHER
Datte �- _p B y Date By Type'
Daps By
D.W.V DRYWALL Type.
Data By Int Brace Wall Date By, W
Date By FINAL INSPECTION p
v Water tine Fin Seperation IV
m Date By Date By Date By C
m �
Pass or Request Inspect. o
zr Type of Insp. Fail Date Date Done By Comments aCD ,
0
C �E okA d 1{ol l 7 6� jai�S t �, < ✓ -1
0
-aYPs� S P-�-oB t-Il -o$ +�7/ �;•� Un
Lt/v— Si !zi -cc
opz*iiY ,CSi4 �o �T
7E,s7—
CD
72r'
s Doge 7-Z7-I0 -77-10 T b1n.n of v1 e
,r1/
07-21614)
vdtGt� CGIJ' ni
0
clipsvel
d- 6, `'