Loading...
HomeMy WebLinkAboutCracks in Slab, Fireplace and Sheetrock - BLD Inspections - 5/22/2001 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Processing/Inspections/Addressing Mason County Bldg.III 426 W.Cedar P.O.Box 186 Shelton,WA 98584 (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 April 6, 2001 Kelly D. and Sheila A. Jackson 409 "H" Street Shelton, WA 98584 RE: Site inspection of March, 2001 409 "H" Street, Shelton Dear Mr. And Mrs. Jackson Our office conducted a site inspection on 03/14/01 for possible earthquake damage at the above location. The inspection was a result of a referral that you made to the Mason County Department of Emergency Services. At the time of the inspection, the inspector noted cracks in the slab, substantial cracks and damage to the masonry fireplace and some sheetrock cracking. During the inspection, you spoke with the inspector regarding the necessity for a thorough inspection by a Washington State licensed Structural Engineer. Please contact the Building Department at (360) 427-9670 Ext. 284 regarding permitting requirements once the engineered report and recommendations have been completed, if they include provisions for new construction or repair of the chimney. The file records indicate that the inspector did not find cause to post the structure for non-occupancy and therefore, the file regarding the earthquake damage has been closed. If we can be of any further assistance, please contact our office at (360) 427-9670 Ext. 356. Sincere Tami Griff Building InspectorLCodeforcement Cc: Property File 3/14/01 Activities for Case #: ENF2001-00043 12:58:23 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes ENFA010 Complaint Received 3/2/01 LW DONE No Hold TLG 3/6/01 ENFB002 Site Invest 3/14/01 3/14/01 LW DONE No Hold LW 3/14/01 THE OWNER WAS ON SITE AND WAS CONCERED ABOUT 3 ITEMS IN THE HOUSE.ONE IS A CRACK IN THE MASONARY FIREPLACE, THE CRACK IS LARGE ENOUGH AND RUNS THRU THE CENTER OF SOME OF THE CMU BLOCKS.AND IS AT LEAST 3/4 THE VERTICL HIEGHT OF THE CHIMNEY. THIS NEEDS TO BE REPAIRED AND SHOULD NOT BE LET GO.THE OWNER IS TO CONTACT A STRUCTURAL ENGINEER TO EVALUATE THE DAMAGE AND DESIGN A FIX.THE OTHER TWO ISSUES APPEAR TO BE NON-STRUCTURAL,SOME MINER CRACKING IN THE UP STAIRS SHEET ROCK AT THE JIONTS AND THERE IS A CRACK IN THE SLAB UNDER THE KITCHEN.THE CRACK DOES NOT APPEAR TO HAVE CAUSE ANY STRUCTURAL DAMAGE BUT IT NEEDS TO BE SEALED TO PREVENT ANY FUTURE WATER DAMAGE. Page 1 of 1 L Li