Loading...
HomeMy WebLinkAboutPAR2018-00034 - PAR Letters / Memos - 10/15/2018 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Building Division Mason County Bldg. 8, 615 West Alder Street, Shelton, WA 98584 ' www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269 MASON COUNTY PRE-SUBMISSION CONFERENCE NOTES • BUILDING DEPARTMENT REPRESENTATIVE: Tricia Woolett (360) 427-9670 ext. 281 E-Mail: tw@co.mason.wa.us • DATE: October 15t", 2018 • PROJECT/ PROJECT TRACKING NUMBER: PAR2018-00034 • PARCEL NUMBER: 12208-23-6000 • SITE ADDRESS: 200 E Campus Drive, Belfair • PROJECT REPRESENTATIVE (S): Erickson McGovern Architects (Raymond Mow) DESCRIPTION & SIZE OF PROJECT/OCCUPANCY CLASSIFICATION & USE: Minor tenant improvement at the existing community gym. Converting an unused music classroom into a health center to be run by Peninsula Heath. Peninsula Health Center provides services to students and staff(physicals etc.) Tenant improvement will consist of additional new non-load bearing walls, plumbing and electrical improvements (22,430 square feet) ALL COMMERCIAL SUBMITTALS ARE BY APPOINTMENT. PLEASE CALL 360.427.9670 EXT. 352 TO SCHEDULE A APPOINTMENT. COMMENTS: Previous occupancy was North Mason High School (E occupancy). Now a community gym (A occupancy) the portion under review will be a B occupancy. Employees indicated on the application equal two. THE FOLLOWING MUST BE INCLUDED ON THE PLANS: • Code Analysis: Must be supplied in the construction plans and completed by a Washington State Licensed Design Professional for the scope of work. • DISTANCES TO OTHER STRUCTURES: Site plan, drawn to scale shall clearly identify distances, where required include fire-resistive details, including continuity, &tested assembly details. • FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details, including continuity, & tested assembly details. • IDENTIFY TYPE OF CONSTRUCTION & PROVIDE ALLOWABLE AREA CALCULATIONS WHERE NEEDED. See Chapter 5, IBC • FIRE-RESISTIVE RATED CONSTRUCTION &TYPE OF CONSTRUCTION: Where required demonstrate compliance. Identify the location of the assembly, compliance to continuity requirements and construction details: Exterior Wall (IBC704), Fire Wall (IBC705), Fire Barrier (IBC706), Shaft Enclosures (IBC 707), Fire Partitions (IBC 708), Smoke Barriers (IBC 709), Smoke Partitions (IBC 710), Horizontal Assemblies (IBC 711), Penetrations (IBC 712), Fire Resistant Joint Systems (IBC 713), Fire- Resistance Rating of Structural Members (IBC 714), Opening Protection (IBC 715), Duct and Air Transfer Openings (IBC 716), Concealed Spaces (IBC 717), ETC, • NUMBER OF EXITS REQUIRED/OCCUPANT LOAD:(IBC 1004): Table 1004 is used to determine occupant load used to evaluate the structure for exiting purposes, plumbing fixture requirements, and other code related concerns. Include design calculations, demonstrating how occupant loads were calculated, on building plans. • EXIT PLAN: Clearly identify the exit path and exit signage on construction plans. • ENGINEERING REQUIRED: Structures that do not comply with prescriptive specifications of the 2015 International Code (IBC) shall be designed in accordance with Chapter 16 of the IBC. Referencing Washington State RCW 18.08.410 - Structures 4000 sq. ft or more shall have all plan pages reviewed and stamped by a Washington State licensed design professional. The review shall include a code evaluation addressing life-safety, plumbing & mechanical evaluation, and structural analysis. (ref. RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED BY THE DESIGN PROFESSIONAL, including plumbing and mechanical pages. • ACCESSIBILITY REQUIRED: YES, must include compliance information and plan details including design details and analysis demonstrating compliance to Chapter 11 and details demonstrating compliance to ANSI 117.1, in effect at the time of submittal. Include information demonstrating compliance for restrooms, employee work areas, parking spaces, accessibility to structure, drinking fountain, signage, etc. Construction plans will NOT be accepted without compliance details include on the plans. • PLUMBING SYSTEMS (Chapter 29 Washington Amendment to IBC): Using IBC Chapter 10, determine occupant load. The number of plumbing fixtures is determined based upon the occupant load. Plumbing fixtures need not be provided for unoccupied buildings. Permitted building shall comply. On plans include design calculations for the following: water closets (M/F), Lavatories, Drinking Fountains, etc. Referencing IBC/WAC 2902.2 separate plumbing fixtures shall be required for each sex, except when the calculated occupancy load is 15 or less, and then unisex fixtures shall be allowed. Plumbing fixture count can be for the entire facility, including all structures) for compliance purposes. Provide design calculations demonstrating how the fixture count was determined on construction plans. • LIGHTING: All non-residential structures shall comply with IECC/WSEC lighting requirements. Complete compliance forms and provide a lighting plan that includes switching locations. Forms are available at: Lighting: http://neec.net/sites/default/files/neec codes/forms15/LTG15-v1.xlsm • Ventilation Code compliance: Must provide calculations and compliance documentation. • INTERIOR FINISHES: Include information demonstrating compliance to Interior finishes required in IBC Chapter 8. • STORAGE SPACES: Identify material stored, anticipated quantities, height, and if hazardous, include MSDS sheets for each product. • STORAGE RACKS: greater than 5'9" shall be permitted either with the proposed project or separate building permit. Where required documents shall include design information demonstrating stability for seismic conditions. Special inspection may be necessary, reference IBC Section 1707.6 and 1705.3 (4.5), storage racks, provide compliance information. • MECHANICAL EQUIPMENT: Identify the location and type of mechanical equipment located within, and outside the structure. Address foundation and support systems for equipment. Where new equipment will be placed on site provide UL listing information and/or construction details shall be stamped by a Washington State licensed design professional. Where applicable include duct information and duct support compliance information. • FIRE MARSHAL REQUIREMENTS: Fire Marshal comments requirements including fire protection requirements and identify compliance information on the proposed building plans. Show the location of fire extinguishers and identify type. The following items must be completed for the project approval: • EMERGENCY VEHICLE ACCESS: "Standards for Fire Apparatus Access Roads: adopted through Mason County Code Title 14 Section 14.17 is attached. Submit documents should clearly identify code compliance. • ADDRESSING: Referencing IFC, Section 505 and Mason County Code Chapter 14.28, all new buildings shall have an approved address. Should discuss with addressing (possible suite numbers) • KNOX BOX: Referencing IFC, Section 506 and access shall be required. Contact your local Fire District for detail to order your Knox box. • SUSPENDED CEILING SYSTEMS: Provide details and specifications relating to suspended ceilings where applicable. Please note we are in a D2 seismic region. Details shall be designed and approved for seismic loading in accordance to IBC Chapter 16. Where required designate special inspection plan. PERMITS REQUIRED FOR PROJECT: n BUILDING (each structure) o PLUMBING / MECHANICAL (each structure) GRADING PERMIT (When greater than 200 cubic yards) D CHANGE OF USE/OCCUPANCY (When each Tenant is identified for use) FIRE SUPPRESSION, See Fire Marshal comments (each structure) o SIGN (each business) FENCE (Greater than 7'0" above grade) RETAINING WALL(S) (one permit for all walls on parcel) ADDITIONAL NOTES: Current Code: 2015 IBC and 2015 IECCM/SEC. ADDITIONAL REQUIREMENT FOR PERMITING: WHEN YOU SUBMIT PERMITS, YOU WILL NEED TWO (2) COPIES OF YOUR SITE/PLOT PLANS, DRAWN TO SCALE, 11X17 PAPER SIZE, ALL NECESSARY PERMIT APPLICATIONS INCLUDING THREE (3) COMPLETE SETS OF BUILDING PLANS WITH CALCULATIONS WHEN REQUIRED. (NOTE: ALL PLAN PAGES SHALL BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHEN: (1)THE STRUCTURE EXCEEDS 4000 SQ. FT., (2) THE STRUCTURE IS ENGINEERED/DESIGNED. • CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section, construction details, etc. • MECHANICAL PLAN, (If a deferred submittal must be indicated on plans at submittal) • PLUMBING PLAN AND (If a deferred submittal must be indicated on plans at submittal) • NON-RESIDENTIAL ENERGY CODENENTILATION & INDOOR AIR QUALITY CODE INFORMATION. • A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED. VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF THE 1997 UBC. DESIGN CRITERIA: SEISMIC ZONE: D2 WIND SPEED: 85 MPH basic 110 ultimate, Exp. B (Unless proven otherwise) GROUND SNOW LOAD: 25 PSF REFERENCE CODE EDITIONS: Effective August 9, 2016 2015 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING H106; SECTIONS 101 THROUGH 107, PUBLISHED BYTHE INTERNATIONAL CODE COUNCIL, AND EXCLUDING APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND; ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51- 50. 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2015 UNIFORM PLUMBING CODE (UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND MECHANICAL OFFICIALS (IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC 51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15, AND 16, PART I. 2015 INTERNATIONAL MECHANICAL CODE(IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC 51-52. 2015 INTERNATIONAL FIRE CODE (IFC) PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING APPENDIX A, D, AND K AND ADOPTING APPENDICES B,C,E,F, G AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-54. 2015 INTERNATIONAL ENERGY CONSERVATION CODE(IECC), AS AMENDED BY WASHINGTON STATE BUILDING CODE WAC 51-11 To view the Mason County Building and Construction Code and adopted amendments go to the Mason County website at: www.co.mason.wa.us MASON COUNTY COMMUNITY SERVICES / Building,Planning,Environmental Health,Community Health / 615 W.Alder St.—Bldg.8,Shelton,Wa 98584 DATE Z�- W 1 Phone:(360)427-9670 ext.352 ♦ Fax:(360)427-7798 PRE-APPLICATION CONFERENCE REQUEST FORM The purpose of the pre-submission conference is to identify and/or eliminate as many potential problems regarding a proposal. Representatives from the Fire Marshal's Office, Building Department, Environmental Health, Planning, and Public Works Departments may attend the meeting to discuss rules and regulations applicable to the proposed project. Topics covered during the meeting may include the comprehensive plan, land divisions, shoreline program, zoning, availability of sewer and potable water, development concepts, building conen ion,-fae`pfotecti n and life safety concerns of the proposed project. The pre-submission conference is intended as an informative`meeting. The intent is to provide detailed information to the applicant in regards to codes and process. (Iz!? L 7 L iB Incomplete applications will not be accepted. If application is deemed incomplete it wilt.-be returned. All Conferences are on Mondays (except h&lidays� To schedule a meeting you must complete the requirements for submittal including the required six(6) copies of detailed site plan(max. size 11"xl7"). To submit either by mail or in person at: Mason County Permit Assistance Center at 615 W Alder Street, Shelton WA 98584 by 3:00 PM on the Monday two weeks prior the proposed meeting. Please make check pavable to: Mason County Treasurer Check amount: $615.00 Owner: Name: North Mason School District (Contact Joan Moore, Maintenance Director) Mailing Address: 250 East Campus Drive, Belfair, WA 98521 Daytime Telephone: 360-277-9085 Email address: -imooree north masonschools.org Fax number: Representative: Name: Erickson McGovern Architects. (Contact Raymond Mow) Mailing Address: 101 East 26th Street, Suite 300, Tacoma, WA 98421 Daytime Telephone: (253) 531-0206 ext. 2008 Email address: Ray(@ericksonmcgovern.com Fax number: Tax Parcel Number (12 digits): 122082360000 Site Address: 200 East Campus Drive, Belfair. Rev.January 2018 *Description of Project: Minor tenant improvement at the existing community gym. Converting an unused music classroom into a health center to be run by Peninsula Health. Health Center provides services to students and staff (physicals etc..). Tenant improvement will consist of additional new non-load bearing walls, plumbing, and electrical improvements ♦Square footage of structure: 22,430 S.F. ♦ Use of building and rooms (i.e., office, warehouse, restaurant, storage, etc): Community use gymnasium, wrestling room and proposed health center. *Occupancy classification per IBC, Section 302.1, and construction type: From an existing E occupancy to an A-4 occupancy with the tenant improvement a B occupancy ♦ Will grading or excavation be included in the project? If so what is an estimate the amount of grading: cut (} cy ,, fill 0 cy ♦ Will Forest Practices be included in the project? If so what is the estimated amount of logging: 9 board feet ♦ Are there any historical stormwater and/or geotechnical reports (prepared for previous development)? Please Indicate Yes ❑ No 0 ♦ Has the project been discussed during a previous Pre-Application Conference? If yes, please indicate date. No ♦ Will the building have employees? Yes ® No ❑ If yes, how many? Two at health center. ♦ What is the proposed source of water? (Please indicate): ❑ Proposed Individual Well, E Existing individual well, ❑ Proposed water system, ❑ Existing Water System, Name of existing water system: ♦ What is the proposed source of sewage disposal? (Please indicate): Existing onsite sewage system, ❑ Proposed onsite sewage system, ❑ Existing sewer connection, ❑ Proposed sewer connection, Name of Sewer System connected to: ♦ Will the project include signage? Yes P No ❑ If Yes, describe; size, material and location: Exterior wall mounted informational signage. ♦ Is there a fire hydrant located within 400 feet? Yes KI No ❑ If, yes include on site plan. The following items must be included (attached): ♦Provide two sets of proposal/plans including a floor plan. Max. paper size 11" x 17". ♦Provide Six (6) copies of the site plan including all items required (see page 3) Provide specific comments or specific questions we can help you with: What the minimum requirements for the proposed improvements. 2 Site Plan Requirements 6 copies are required at submittal Include thefollowing information Indicate Scale and North Arrow (] Property line dimensions, easements, and right-of-ways. The location of all existing and proposed structures. Include square footage of existing and proposed structures. ] Setback distance, in feet from all property lines and structures. Existing and proposed road access to and from the site. ® Parking sites Location of on-site sewage tanks and drainfields. Location of drinking water supply. Include location on the proposed site and surrounding parcels. J Steep slope, wetlands, streams, and bodies of water Location of fire hydrants and emergency vehicle access roads, including grade. ❑ Surface and storm water run-off routes. The site plan should be provided on letter (8.5" by 11"), legal (8.5" by 14"), or 11" by 17" (a larger one could be provided in addition to this). ❑ If there are several buildings on the site and/or proposed, to label each one A, B, C, D, ... ❑ Show EXISTING drainage features (infiltration ditches, retention ponds, etc). ❑ Show BOUNDARIES, area and volume of proposed site disturbance (this includes clearing and grading limits, proposed timber harvest activity/tree-cutting, landscaping. ❑ Show all the existing and proposed impervious surface areas (including gravel driveway, loading, parking etc) in square feet. APPLICABLE BUILDING CODES 2015 International Building Code/2015 International Residential Code 2015 International Fire Code-ANSI A117 2015 International Mechanical Code—WAC 51-42 2015 Uniform Plumbing Code—WAC 51-56/51-47 2015 International Energy Code/Washington State Energy Code—WAC 51-11C & 51-11 R Mason County Ordinance Title 14 &Code changes are on a 3 year cycle; effective in July of that particular year. Date of Conference: I C)- +5 , 2_0 1 8 Time of Conference: 9 : �36 A YY1 Location of Conference: 415 N 6th Streets, Shelton WA PIanner'�C)r} ext. Z8 rf 3 Plotted: Sep 26,2018- 3:28pm File: %!\2018-37 NMS)Health Center Remodel\6 Drowinge\9-Currant\A- AutoCAD\2018-37 A2.00.dwg By. JOSH 3 L1 O 0 �0 m -InI A I IIJJ _ _— o Llo 0 0 o a o o j - I m a� :I I III,ail OO D ��' IIIIitI' a N E z� I I !l m 17,7 I �v. o6z NOE� �o I I. �o Ei / I I HXo I �� I I ti I Z O F,0 I� � I y r rL — — — — — — — — — — — \ T ' ----- ' r 0 O m 70 og -u \ -- — — � — � — � � II Z � e 7-7 o D o o OVERALL FLOOR PLAN ERICKSON • McGOVERN O q�W HEALTH CENTER REMODEL NORTH MASON SCHOOL DISTRICT 101 E.261h Street.S01.300,Tom—,WA 98421 No.403 ee L J r- Lu > of GENERAL NOTE: O 0 0 1. CONTRACTOR TO COORDINATE WITH THE OWNER ON ACCESS,SECURITY AND FIRE ALARM SHUT Off DURING DEMOLITION AND NEW CONSTRUCTION. I, .TT Mm 2 CONTRACTOR TO PROVIDE DUST AND DEBRIS BARRIERS AS REQUIRED FOR THE WORK 6 r 3. CONTRACTOR REQUIRED TO PATCH ANY AND ALL REMOVED EXISTING MATERIALS TO ACHIEVE THE FINAL PRODUCT. a = 6. VERIFY ROUTING OF ALL ELECTRICAL WIRING AND DEVICE Z PRIOR TO STARE OF WORK O � DEMOLITION NOTES: N WAITING AREA 1. DEMOUSHIXISRNGRM. u 21 w LI..I LAB EXAM 21B 21A 21C Z OFROOM STORAGE J O co J O u_ O Z REFLECTED CEILING PLAN Q J C) SCALE 1/4"=1'-d' J NORTH Lu O 0 ° 0LL 0 LL. 0 0 wU OFFICES STORAGE "EL f.— N a77 t8 INSTRUMENT STORAGE PRACTICE OFFICE/LIBRARY PRACTICE w Z Z u10 0 TH,nY U cQc n V = G m Z t _ x W0 B w 2 Z 3 I b MUSK/VOCAL ———————————————-- L YIIOND sc I `POWER POLENr I j j j Ah � SON * I I I I I I COPIER/PRINTER/FAX I I I I I WAITING AREA I I ♦ I I �� € i ` ♦ ♦`-----------� ;J � I ♦ / I L ♦♦ ------------------J hgect 2018-37 z / \ ♦ / LAB ♦ / Drown: JTM t 0 0EXAM 278 EXAM I \\ / 21A • r2IC \\ / / 4 ❑ \`—————————————————————————JIT I( IDF ROOM OH STORAGE STORAGE STORAGE C DC ryX n mSheet: ry vd Bal? rat? 'I FLOOR PLAN EXISTING / DEMO FLOOR PLAN A2.0 1 - - NORTH — - 1 NORTH SCALE:1/4"=V-7SCALE:1/4"=1'•d' 0 s r z PER ^j SCMED. PER DOOR Lu o: 3 SCHFD. > 344 6 ASM E O � 0 � U s� g $ I; !� � Z t O � SG O N o UG 6 DOOR 25 O SG SAFETY FEMPERED)GLAZING DOOR TYPES FRAME TYPES U Lie SCALE:7/4"=1'-0" 2 (ALL FRAMES ARE TO BE 7 HOLLOW METAL SCALE:7/4"=1'-0" 1 Lu UNLESS OTHERWISE NOTED) Lu J 0 Lu Al U HEADER AS APPLIES Ln SEE STRUCT. - I/7'(BOTH SIDES) 0 CONT.SEALANT(BOTH SOESI O DOORFEAD T-T AFF Q H.M.FRAME-GROUT FILLED Z Q Q N v DOOR(PER SCHEDULE) Lu O a_ Z r J J U J Lu C) DOOR/HEAD JAMB DETAIL o 00 J INTDROI.dwc Scale:3"=1'-0" Z Lu 0 Lu O Q m Lu N H 9 8 Lu O Z < U cQ n R O _ 3 O Lu 0 8 p 2 Z 3 ABBREVIATIONS ACV ACOUSTICAL CEILING PANEL I ASV ABRASIVE SHEEP VINYL 1100 CONC CONCRETE E ff M9llIG10N % CPT CARPET CB COVE BASE(6.UNO) e CL CHAINLNK ECONC EXISTING CONCRETE E EM ENTRY MAT �p EPT EPDXY PAINT L ESV EXISTING SHEET VINYL FF FACTORY FINISH FRP FIBERGLASS PANELS I TO B'-O'AFF LINO) GWB GYPSUM WALLBOARD OTSA OPEN 705TRU( ABOVE B PL PLASTIC LAMINATE(TO 44r UNO) FLOOR BASE EAST WALL SOUTH m NORTH WALL CEILING PLWO PLYWOOD ROOM No.ROOM NAME MATERIAL FINISH MATERIAL FINISH MATERIAL FNISH MATERIAL ISH MATERIAL FNISH MATERIAL FINISH HEGHT NOTES: u PT PAINT 21 WAITING - FF IX FP EX PT IX IX PT EX6TNG - RB RUBBER BASEI4'UNOI 21A EXAM CPT FF RB FF GWB PT GWB GWB PT qCi FF y ST STAIN = SV SHEET VINYL 21B LAB CPT FF RB FF GWB PT GWB GWB PT ACT FF S SEAL 21C EXAM CPT fF RB FF GWB PT GWB I GWB I PT I ACT FF Q V VARIES Project 2018-37 5 FINISH SCHEDULE O DTOWT vA" _p SCALE:- ABBREVIATIONS IX EXISTING FF FACTORY FINISH FRP FIBERGLASS HM HOLLOW METAL INSUL INSULATED LSG LAMINATED SAFETY GLASS 5/8'GWB TYPE'X' n MTL METAL Ol 2X6 MINIMUM- FRAYING O TB'o.c. ON OVERHEAD DOOR SIZE DOOR SELF PANIC A FILL CAVITY WITH SOUND ATTENUATION BLANKET m SG SAFEtt GLAZING(Tl?.LPERED G1A551 DOOR IN PAR WIDTH HEIGHT THICK TYPE MATERIAL FINISH CLOSING RATING HARDWARE TYPE MATL FINISH REMARKS BA9c YAIl rrr� INSULATION Sheet. SS STAINLESS STEEL 21A 34r 7.(r 13/4' A WD ST 20 MIN. I HM PT 5/B GWB TYPE'XSTEELST STAIN 21C 3V 7-713/4' A WO ST 20 MIN. 1 HM PT N WD WOOD -NEW HOLLOW METAL FRAMES d W OOD DOORS SHALL MEET N WA BD FOR RAT®ASSEMBLES DOOR SCHEDULE WALL TYPES A5.00 SCALE-© SCALE 7"=1'-0" 4 s r ' � NORTH MASON SCHOOL DISTRICT HEALTH CENTER REMODEL w 56 0 E O 00 NORTH MASON SCHOOL DISTRICT No. 403 VICINITY MAP PROJECT INFORMATION (CONT.) SCHEDULE OF DRAWING NORTH _ t ' EXISTING BUILDING SUE VENT S.F. O N AREA OF TENANT IMPROVEMENT:1.6995.F. THE DRAWINGS CONTAIN REFERENCE TO EXISTING CONDITIONS.MATERIALS.ft1Rr..;r„I:�;1 K INFORMATION. A0.00 PROJECT w EX ING OCCUPANCY TYPE F(EDUCATIONAL) AND EQUIPMENT.THE INFORMATION IS DEVELOPED FROM EXW14G DRAWINGS AND SITE V) o PROPOSED OCCUPANCY TYPE:'A-4"WITH TENANT IMPROVEMENT TOE'"OCCUPANCY AND BUILDING OBSERVATIONS,AND IS PROVIDED FOR REFERENCE ONLY.THE CONTRACTOR ARCHITECTURAL DRAWINGS �Iz 1 SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.IT IS TO BE ASSUMED THE EXISTING CONSTRUCTION TYPE:TYPE 4 HEAVY TIMBER BUILDING IS NOT LEVEL.SQUARE OR PLUMB.SUBMITTING A 810 SHALL INDICATE THE AAD ENLARGED SITE PLAN v EXISTING HAWKINS GYM FIRE ALARM SYSTEM:YES(EXISTING) CONTRACTORS ACCEPTANCE OF THE EXISTING CONDITIONS.AND WILLINGNESS TO PROVIDE Al2.00 OVERALL FLOOR RAN FIRE SPRINKLER SYSTEM:NO THE LABOR.MATERIALS,AND EQUIPMENT NECESSARY TO COMPLETE THE WORK INTENDED BY A2.01 EXISTING FLOOR PLAN/NEW FLOOR PLAN/REFLECTED CEII Ir IC PLC.r, 01 THE CONTRACT DOCUMENTS. A5.00 DETAILS LjJ 0 o�'. NEW NORTH MASON HIGH SCHOOL SYMBOLS T EXISTING ANNEX W 4 HALLWAYEXISTINGNORMMASON 100 ROOM NAME AND NUMBER HIGHSCHOOL/NWHAWKINS CODE NORTH AAROW MIDDLE SCHOOL SCOPE ^ ^ ^ I/ 20:51NTERNATIONAL BUILDING CODE W/WASHNGTON STATE AMENDMENTS S l.l J P E l J F W�J R I� � WINDOW,RELRE LOUVER TYPE .o.YCT 9 DETAIL SYMBOL Qj REVISION SYMBOL 20151NTERNATIONAL FIRE CODE W/WASHINGTON STATE AMENDMENTS A8.1 20:5 INTERNATIONAL MECHANICAL CODE W/WASHINGTON STATE AMENDMENTS MINOR REVISIONS THE EXISTING COMMUNITYGYM.CONVERT EXISTING MUSIC PAINT TYPES MBOL A CLASSROOM INTO A HEALTH CENTER LEASED TOO PENINSULA HEALTH CARE STATE ROUTE 302 A NOTE REFERENCE SYMBOL 205 UNIFORM PLUMBING CODE W/WASHINGTON STATE AMENDMENTS GYMNASIUM BUILDING IS NO LONGER ALLOWED TO BE USED FOR EDUCATIONAL G �Ie PURPOSES PER OSR. 3 INTERIOR ELEVATION 2014 NATIONAL ELECTRICAL CODE INFPA 70) PROJECT PER RESULT IN A CHANGE OF USE FROM AN F OCCUPANCY TO AN"A'• B4 A7.02 SYMBOL IA W ALL TYPE SYMBOL SEE AS.00 PROJECT INFORM/s T l/1 1 2015 WASHINGTON STATE ENERGY CODE OCCUPANCY.WITH THE HEALTH CENTER BEING A'TY OCCUPANCY. C % WHERE MULTIPLE WALL TYPES OCCUR IVL LJf[)V1/-1 IJIV 18"412CUR U.N.O. BARRIER FREE-INTERNATIONAL CODE COUNCIL-ANSI STANDARD 117.1 i 4 SECTION SYMBOL U.N.O. T.O.GLULAM I TYPICAL DOOR LAYOUT PROJECT ADDRESS: 20O E.CAMPUS DRIVE BELFAIR.WA 98528 ENLARGED SITE PLAN HEIGHT ABOVE SYMBOL L O_T A.F.F. (� PARCEL NUMBER: 12207 1 i 600101 6.70 ACRES) SEE I LJ FIRE EXTINGUISHER WITH CABINET O 12207 22 60000 143.36 ACRES) A 1 Ek SEE AO.01 8 SPECS. 1 T'CLR TYP.U.N.O. 122D8 23 60010 110.00 ACRES) 0 z I z2ae 236000012o.os ACRES: 2400000 140.00 ACRE) Li J ~ 12208 53 020761 0.14 ACRES( roxEn rare n.n Tarr n.lo �.I n-lo -rox...� r® ter�m Il•",�"III - W w U f00"�-'� - - "..L- nullllia.•wea liullul N Q N AREA: SffSITE:120.25 ACRES _ ticll.a z O o O J i PARCEL 122082260000: \ 111II: LOTS I TO B.LOTS 13 TO 20.AND LOTS 23 TO 28,ALL INCLUSIVE BLOCK I: I-"on1O 1 +/I�4 - i Lu O LOTS 6 TO 15 AND LOTS I B TO 56.ALL INCLUSIVE BLOCK 2 _ < y LOTS I TO 56.BOTH INCLUSIVE BLOCK 3: mvmm�� I m m m C m LOTS 1 TO 56,BOTH INCLUSIVE BLOCK 4: r 1 r a I _c W U o, LOTS 1 TO 56.ALL INCLUSIVE BLOCK 5; O ' Z 3 LOTS I TO 56,ALL INCLUSIVE BLOCK 6: _ of L o LOTS 7 TO 22,BOTH INCLUSIVE BLOCK 7; I a ' O I Z w O IIIIIIIIIIIIIIIIIIIIIIII11111111111111111 I - `J v7 a LOTS 170 45.BOTH INCLUSIVE BLOCK 8: �o.e n.lo Q LOTS 1 TO 12 AND LOiS 14 TO 45.ALL INCLUSIVE BLOCK 9; LOTS I TO I5.BOTH INCLUSIVE BLOCK 10: r Ivro �, 7 I W �. m LOTS 1 TO 45.BOTH INCLUSIVE BLOCK 11; I { Q I J = j LOTS I TO 45,BOTH NCLUSNE BLOCK 12 J1 16�y I J w O if n„ Ll ALL IN THE PLAT OF LAKEWOOD KEW OODU PT"K".VOLUME 2 OF PLATS.PAGE 35.RECORDS OF MASON L w j >6 i} LLJ 0 o COUNTY. I CL 2 Z WASHNGTON. C mRev ^ Yf0 TOGETHER WITH ALL VACATED STREETS IN SAID PUT WHICH ATTACHED THERETO BY OPERATION OF n n j LAW ? UPON THEIR VACATIONS. lor�en Ivn _ r4nlo XRR'�I'NT sLTRm u _ - � TEEXCEPTING THEREFROM THAT PORTION THEREOF CONVEYEDTO MASON COUNTY,WASHINGTON.A q.MUNICIPAL CORPORATION.IN DEED RECORDED AUGUST 29,1967.AUDITOR'S FILE NO.2287B.5. ' AIIISF@IGTpR w I 'PARCEL 12208 23 60010: o ALL THAT PORTION OF THE NORM 330 FEET OF THE SOUTHWEST QUARTER(SW'A)OF THE NORTHWEST S o QUARTER 'AI OF SECTION B,TOWNSHIP E NORTH.RANGE I WEST,W.M.LYING EASTERLY OF EASTERLY RIG RIGHT-0f-WAY LINE OF STATE ROUTE 3. o woa u EXCEPTING THEREFROM THAT PORTION THEREOF PARTICULARLY DESCRIBED AS FOLLOWS: I nu BEGINNING AT THE SOUTHWEST CORNER OF SAID NORTH 330 FEET OF THE SOUTHWEST QUARTER SW I In o'er s' n3 11°� c 'A)OF THE NORTHWEST QUARTER(NW'/.): U THENCE NORTH O°41'54"EAST,ALONG THE WEST UNEOF SAID SOUTHWEST QUARTER ISW'AI OFTFE NORTHWEST QUARTER(NW'/.),95.00 FEET: i mr 8 Tj I & Ip ' 6 oum Bn °o THENCE SOUTHEASTERLY TO A POINT ON THE SOUTH LINE OF SAID NORM 330 FEET OF THE SOUTHWEST QUARTER(SW'A OF THE NORTHWEST QUARTER(NW'A)•SAID POINT BEING 95.00 FEET EASTERLY OF VOr THE POINT OF BEGINNING: I I I - - ' I Project: 2018-37 THENCE WESTERLY,ALONG THE SOUTH LINE OF SAID NORTH 330 FEET OF THE SOUTHWEST QUARTER ISW z ' IQ �' .•R'�..�. �r I'/.)OF THE NORTHWEST QUARTER(NW'/.I,95.00 FEE i0 THE POINT OF BEGINNING. o Drawn: JTM n C ~tea TOGETHER WITH ALL THAT PORTION OF THE SOUTHEAST QUARTER(SE'/.)OF THE NORTHEAST QUARTER - a INE _ v.I OF SECTION 7.TOWNSHIP 22 NORM.RANGE I WET,VIM..PARTICULARLY DESCRIBEDAS 'T- x FOLLOWS: d4r NORM BEGINNING AT THE NORTHEAST CORNER Of SAID SOUTHEAST QUARTER(SE'/.)Of THE NORTHEAST E QUARTER INE'/.);THENCE SOUTH.ALONG THE EAST LINE THEREOF,95.00 FEET: THENCE NORTHWESTERLY TO A POINT ON THE NORTH LINE OF SAID SOUTHEAST QUARTER ISE'A)Of Scale:V=150'-0" THE NORTHEAST QUARTER(NE'/.)WHICH IS 95.00 FEET WESTERLY OF THE THE POINT OF BEGINNING: THENCE EASTERLY,ALONG SAID NORM LINE 95.00 FEET TO THE POINT OF BEGINNING. PROJECT TEAM Sheet: ZONE- COMMUNITY PTMk ARCH OWNS OCCUPANCY TYPESET 101 EAON McGOVERN_PLLC NORM MASONS DRIVE DISTRICT Na 403 ♦ 0.00 CONSTRUCTION TYPE:TYPE" 101 EAST 267E STR G SUITE 421 71 EAST CAMPUS DRIVE A TACOMA.WASHINGTON 98421 BflFAIR,WASMINGTON 9852E FIRE SPRINKLER YES P 253�53140206 P:13601277-2300 FIRE ALARM:YE F 253-531-9197 F:1360)277-2320 CONTACTS:RAY MOW,AIA CONTACT:ERIC NELSON-HAINUNE EMAIL:r @eridwnmcgov6m.can a w Plotted: Sep 28•2018- 3:27pm File: X:\2018-37 NMSD Health Canter Remodel\B Drawings\9-Currant\A-AutoCAD\2018-37 A1.00.dwg By. JOSH 71 i L—. .. o i �P r 199 lvkl , f r � r I I r t A j. � 4 J r Q. a z A Vx m 1 r 0 w , ` ti ORII.E - r w .- fll , I tip' h i i � PI M o 0 r m > I I � a Or F D m Q z m I sN z 0 D o a ENLARGED SITE PLAN ERICKSON • McGOVERN HEALTH CENTER REMODEL O 3 ILI Erickson McGovern P.L.L.C. NORTH MASON SCHOOL DISTRICT No.403 101 E.261h Street.Suite 300,Tacoma,WA 98421 — J