00MMERCIAL BUILDING PERMIT COM2011-00082
OWNER: NORTH MASON SCHOOL DISTRICT RECEIVED: 9/15/2011
CONTRACTOR: SCOTT& FROM CO INC 1.253.473.6644 LICENSE: SCOTTI*225DZ EXP: 7/11/2013 ISSUED: 10/18/2011
SITE ADDRESS: 300 E CAMPUS DR (HAWKINS MS) BELFAIR EXPIRES: 4/18/2012
PARCEL NUMBER: 122082360000
LEGAL DESCRIPTION: SW NW E OF R/W" SEE SURVEY 9/14
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Replacing 9 Furnace units with new Gas furnace units, 4 ST RT 3 TO BELFAIR, R ON NORTH MASON SCHOOL RD, R ON CAMPUS
exhaust fans, DR TO SITE ADDRESS
General Information Construction &Occupancy Information
Type of Use: COMMERCIAL Insp.Area: No. of Units: Type of Constr.:
Type of Work: MEC Fire Dist.: 2 No. of Bathrooms: Occ. Group:
Valuation: No.of Stories: Exit Design. Load:
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPA?: Comp. Plan Desig.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2011-00082 Please refer to the following pages for conditions of this permit. Page 1 of 5
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Furnace>100K 9 Mechanical Permit Fee i Aw iniig»ni VA17 rn Ri9ni inn
Gas Outlets 9 Mechanical Base Fee i Aw ini19nni �9a rn gi9niinn
Ventilation Fan 4 Non-Res. Energy Code ni r. iniivnni ItTi nn Ci9ni inn
Total $439.00
CASE NOTES FOR
COM2011-00082
CONDITIONS FOR
COM2011-00082
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X LIZ
2) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to
construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are
removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and
X collected by he Mason County Building Department prior to any further inspections being performed or approvals granted.
3) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND
OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD
RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x T
4) Changes to approved building plans that affect compliance to the current Washington State Energy Code (WSEC), ventilationrequirements),
Building/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction.
X 4
5) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE
ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in
conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a
Mason County Building Inspector shall be made prior to requesting additional inspections.
X <
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-com plian with Mason County ordinances and building regulations.
X
COM2011-00082 Page 2 of 5
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the
time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control
Xthe permit have prevented action from being taken. No more than one extension may be granted.
R 8) The mechanical system for which energy consumption, performance, or mode of operation are regulated by the Washington State Energy Code
(WSEC) shall be tested to ensure that control devices, equipment and systems are calibrated, adjusted and operate in accordance with approved
plans and specifications.
Drawings and notes shall require commissioning in accordance with WSEC section 1416 . For all mechanical systems, commissioning shall
include, as a minimum:
a. A Commissioning Plan (See WSEC 1416.2.1),
b. System Testing and Balancing (See WSEC 1416.2.2),
c. Equipment Functional Performance Testing (See WSEC 1416.2.3),
d. Controls Functional Performance Testing (See WSEC 1416.2.3),
e. A Preliminary Commissioning Report(See WSEC 1416.2.5),
f. Post Construction Documentation (all) (See WSEC 1416.2.4), and
g. A Final Commissioning Report(See WSEC 1416.2.5).
Buildings or portions thereof, required by this code to comply with this section, shall not be issued a final certificate of occupancy until such time
that the building official determines that the preliminary commissioning report required by Section 1416.2.5.1 has been completed.
Lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in
accordance with the approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the
owner. Drawing notes shall require commissioning in accordance with WSEC 1513.7.
Commisning reports shall be made available for the Mason County Building Inspector during the final occupancy inspection.
X
9) All return and supply air opening shall maintain a minimum of 3 feet to all existing smoke and heat detectors.
X Z -
10) This project is approved to replace 9 furnace units with new Gas furnace units and 4 exhaust fans.
Installation of equipment and replacement furnaces shall comply with Chapter 14 of the 2009 Washington State Energy Code. Air economizers
shall be capable of providing 100% of the design supply air as outside air to reduce or eliminate the need for cooling. All new ductwork shall be
insulated and sealed in accordance with section 1414 and shall be leak tested. Leak testing and balancing reports shall be available for inspection.
A comissioning compliance checklist shall be available for the building inspector during the final inspection or submitted to the building department
prior to the final inspection of this project, reference figure 14B Section 1416.
X e- -
COM2011-00082 Page 3 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate
and grants employees of Mason County access to the above described property and structure for revvi w and inspection.
OWNER OR AGENT: DATE: , / 7/q
COM2011-00082 Page 4 of 5
O Z
K CONCRETE MECHANICAL MANUFACTURED HOME 0
N
CD
Footings Isatbacks Dale Gas piping By Ribbons =
o Interior Date By Interior•Date By Date By ic
NExterior Date BY Exterior Date By Set-up (n
Point Load I Isolated Footings INSULATION date By Z
BQ I SLAB INSULATION
Date __.._ By Data By FIRE DEPARTMENT n
Foundation Wails Floors Date By Z
Date, By Data By DECKS 0
FRAMING Walls Date By r
Date By Data By PROPANE TANKS
PLUMBING vault Date By
Date By OTHER
Groundwork Attic n
Date By Type.
Data B y _---•---- Dale By
o.w.v DRYWALL Type. n
Int Brace Wall Date By O
Date By
Date By FINAL INSPECTION N
Water Line Fire Seperation
Date By Date By Date By
O
Pass or Request Inspect. o
Type of Insp. Fail Date Date Done By Comments co
1-1 L Cc
f
I
cfl i
m
cri
0
Na
(D+ 4-t�p
IJ4 i fs i n rbo/rt -
�
MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST
Owner's Name: Date: Reviewed By:
Documents:
_Building Permit Application Completed Stormwater Checklist
_Planning Intake Checklist Completed,
_Site plan includes:Allowable building area,roof overhangs,decks,etc.
Fire Apparatus Access Road info required? Yes/No
_Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace
O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type )
O Other. Specify:
_Mechanical/Plumbing Application-WATER HEATER FUEL TYPE/LOCATION
_Engineering? Yes/No Snow load: Seismic:
Stock Plan—approved snow load: Seismic:
Manufactured Homes—4 FLOOR PLANS
Foundation Type: ANSI/Manufacture method Engineered footing/foundation Basement
Decks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required.
Construction Plans:_3 COMPLETE SETS
—Plans Legible _Recognized Scale _Elevation Views _Cross Section
_Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors)
_Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F. ??—stairs?)
Deck Framing Plan,incl cov.porch framing
Plan Details:
_Roof framing details,truss lay-out may be needed (Hip and girder location shown)
_Wall Framing-Does bearing-wall height exceed 10'?(Engineering may be required)
_Floor framing: Floor joists(size&spacing): ,Floor beams:
_Window headers. Typical header. Garage header:
—Foundation:footing size,reinforcement
_Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required see details)
_Landings at all exits?Less than 30"above grade?Y/N
—Heated By Furnace-Location of Furnace Fuel type:
_Fireplace/Stove Information Shown-Fuel Type? Location(s):
_Window Sizes Marked on Plans
_ Braced wall panels(shear walls)marked on plans or lateral engineering?
2-story garage? (Engineering may be required) 1'`story of two story D1—45%,D2—55%
COMMENTS:
ENGINEERING REQUIRED
Braced wall panels/brace wall lines are not marked on plans(R602.10)
Amount and location of bracing does not meet minimum required in Table R602.10.1
DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed
building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: ,Snow_psf.
IRREGULAR BUILDINGS R301.2.2.2.2
Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be
considered to be irregular when one or more of the following conditions occur:
1)Exterior braced wall line or BWP cantilevered or offset by more than 4'
2)Roof or floor is not laterally supported on all edges
2A)Portion of roof or floor extend more than 6 1 beyond the braced wall line.
3)End of BWP extends more than 1 $.over an opening more than 8 ft in width below.
4)Opening in a floor or roof exceed the lesser of 12$.or 50%of the least floor or roof dimension.
5)Portions of floor level are offset vertically
6)Shear wall lines do not occur in two perpendicular directions.
7)When a story above grade is includes masonry or concrete construction(exc: fireplaces, chimneys,and veneer).
When this applies the entire story shall be designed.In accordance with accepted engineering practice.
H:\permit tech building checklist.doc Revised 11-29-2007
r PERMIT NO.
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360)427-9670;Belfair(360)275-4467•Elma(360)482-5269
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner North Mason School District Company NameScott & From Co. , Inc.
Mailing Address 71 E Campus Drive Mailing Ad 3820 S. Junett St.
City Belfair State WA Zip Code 98528 City Ta ma tate��Zip Code 98409
Phone360-277-2300 Other Ph. Phone — — Other Ph.
Lien/Title Holder N A Contrac e *225DZ Ex 7/11/2013
E mail address N/A E Mail Address oug scottan rom.�6m
Drivers Lic.# N/A DOB Drivers Lic.# DOB
SEPTIC INFORMATION - Connect to New Septic N/A Existing Septic. N/A Connect to Sewer System N A
Name of Sewer System N/A
PARCEL INFORMATION - 12 Digit Parcel No Fire District
Legal Description NW NW Ex Vacated Part of Lakewood Platte bo
Site Address (Please include street name,street number and city)$ • Campus Drive, Belfair, WA
Directions to site Site is Hawkins Middle School. Turn onto Campus Drive off of Hwy 3 about
1 mile south of Belfair
Is property.within 200'of Saltwater ° Lake IN 0 River/Creek ° Pond °
Wetland Unknowl8easonal Runoff U Stream _ Slopes or Bluffs > 15%
TYPE OF JOB - New Add Alt Repair Other Replace Use of Building School
Location of Fixtures/Units- 1 st Floor X 2nd Floor Basement Garage Closet
PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:Electric X LPG_Natural Gas X Heat Pump_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace ^9
Bath Tubs Heatpumps
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kithen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
ll TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF 0 CO UATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION/
X Date:
Owner/Owners Representativ /Contractor (indicate which one)
�►`S �y���� FOR OFFICIAL USE BEY T S POINT
Accepted b Planning Pd Ck# Date Bld Pd Receipt No.
DEPARTM NTAL REVIEW APPROVED DENIED NOTES
Building Department C 'e-vn i 't7 %n / l/
Occ Grou —Type Constr.
Planning Department ' 6 n 0 te 1(4 i
Environmental Health Department A t+
FEES
Plumbing & Base Fee Site Inspection
Mechanical & Base fee UFC Plan Review Fee
Wood/Gas/Pellet Stove Fee Other S E� 2P6
Violation Fee TOTAL FEES
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
General/Specialty Contractor
A business registered as a construction contractor with Llil to perform construction work within the scope of
its specialty.A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name SCOTT fx FROM CO INC UBI No. 600270220
Phone 2534736644 Status Active
Address 3820 S Junett St License No. SCOTTI'225DZ
Suite/Apt. License Type Construction Contractor
City Tacoma Effective Date 3/9/1978
State WA Expiration Date 7/11/2013
Zip 98409 Suspend Date
County Pierce Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name Role Effective Date Expiration Date
NUGENT,MARVIN DUANE President 03/09/1978
NUGENT, DOUGLAS PAUL Vice President 06/30/2011
NUGENT, PAUL W Secretary 01/01/1980 06/23/2011
Bond Information
Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date
7 DEVELOPERS SURETY 579187C 07/01/2007 Until Cancelled $12,000.0006/14/2007
8 INDEM CO
6 GREAT AMERICAN INS 0794329 07/01/2002 Until Cancelled 07/04/2007 $12,000.0006/11/2002
Co
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date
26 West American BKW53745894 07/01/2009 07/01/2012 $1,000,000.0006/28/2011
Ins Co
25 CEENTURY SURETY 01CCP553906 07/01/2008 07/01/2009 $1,000,000.00 07/07/2008
24 CONTINENTAL CWP2622672 07/01/2006 07/01/2009 $1,000,000.0006/24/2008
WESTERN INS CO
23 T INS CO RANSPORTATIONTCP2025351 44707/01/2005 07/01/2006 $1,000,000.0007/13/2005
1 - - i
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https:Hfortress.wa.gov/lnilbbip/Print.aspx 9/15/2011