HomeMy WebLinkAboutBLD2013-00816 Revised Demo, Replace SFR FINAL - BLD Permit / Conditions - 8/7/2014 Inspection Line (jeu)4z/-/ztiz MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 too RESIDENTIAL BUILDING PERMIT BLD2013-00816 OWNER: KENT ROBERTS RECEIVED: 9/11/2013 CONTRACTOR: LICENSE: EXP: ISSUED: 10/15/2013 SITE ADDRESS: 3490 E STATE ROUTE 302 BELFAIR EXPIRES: 4/15/2014 PARCEL NUMBER: 122212100100 LEGAL DESCRIPTION: TR 10 OF GOVT LOT 1 &T.L. PROJECT DESCRIPTION: DIRECTIONS TO SITE: DEMOLISH EXISTING RESIDENCE AND BUILD NEW RESIDENCE LEAVING ALLYN GO EAST ON HWY 302. HOUSE ON THE RIGHT AFTER OVERHEAD POWERLINES General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building:1,895 Garage-Attached 624 Valuation: $ 236,712.35 Building Height: Occ. Status: Primary Basement: cov entry 72 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 25.0 Ft. Shoreline: 3§.0 Ft. Water Body: CASE INLET Rear: W 24.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Shoreline Desig.: Urban Side 1: N 13.0 Ft. Year: Serial No.: Side 2: S Ft. .5 ) _j I Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures - �i - I� C �� FEES Type Qty. Type Qty. Tye By Date Amount Receipt Water Closets (Toilets) 2 Heat Pump 1 Plan Check Fee TW 9/11/2013 $ 1,144.62 S2201300000001 Lavatories 3 Furnace<100K 1 Planning Review Fee TW 9/11/2013 $205.00 S2201300000001 Bath Tubs 1 Ventilation Fan 3 Building State Fee DLC 10/3/2013 $4.50 S1201300000001 Showers 1 Propane Tank 1 Building Permit Fee DLC 10/3/2013 $ 1,760.95 S1201300000001 Water Heaters 1 Gas Outlets 2 Mechanical Permit Fee DLC 10/3/2013 $237.90 S1201300000001 Clothes Washer 1 Fireplace 1 Mechanical Base Fee DLC 10/3/2013 $28.50 S1201300000001 Kitchen Sink 1 Exhaust Hood 1 Plumbing Permit Fee DLC 10/3/2013 $ 110.60 S1201300000001 Dishwasher 1 Dryer Vent 1 Plumbing Base Fee DLC 10/3/2013 $24.70 S1 2 01 300000001 Hosebibs 3 EH Plan Review CEW 10/4/2013 $ 103.00 S1201300000001 Laundry Tray 1 Total $ 3,619.77 BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 1 of 6 CASE NOTES FOR BLD2013-00816 CONDITIONS FOR BLD2013-00816 1) A Road Access Permit or Approval must be granted by the Washington State Depaent of Transportation. For more information contact Paula r Hammond, Transportation Planning Engineer, at(206)357-2620, ext. 630. X C_- 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-72. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X � C a 3) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X SC 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted.o X �— 5) Owner/A entis responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X c 6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. x C 8) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building DeRartment prior to any further inspections being performed or approvals granted. X BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 2 of 6 All windows and doors shall be installed and flashed in accordance with the manutacturers written installation instructions and snali be available during inspections. In addition to other inspection(s), an inspection of the flashing shall be required for projects located in an area with a wind exposure of C or D, reference IRC R301.2.1.4 & IBC 1609.4. The design criteria for this project is established at 85 mph wind speed, exposure C. X 10) WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X �- 11) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X 12) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 13) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be X charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 15) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 3 of 6 16) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project., X C w 17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building X Inspector shall be made prior to requesting additional inspections. w 19) All property lines shall be clearly identified at the time of foundation inspection. X C 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X C� 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X s 22) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD�VAY. X C, .J 23) EXISTING GRINDER PUMP TANK WILL NEED TO BE MOVED. THIS MUST BE DONE IN ACCORDANCE WITH PUBLIC WORKS UTILITIES. AN APPROVED PERMIT FROM UTILITIES MUST BE COMPLETED AND SIGNED OFF PRIOR TO OCCUPANCY. X C_ v BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 4 of 6 A&4) Washington State Energy Code Compliance has been approved as tollows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table R406.2 shall be completed: Using option 313 and 5A: Heat pump HSPS 8.5 or better 5A Electric WH, EF 0.93 or better. Heat equipment max output:27069 btu/hr, or 8 KW, or provide heat load calculation demonstrating compliance to energy code specifications. X 25) This building permit is approved to demolish and remove the existing dwelling structure and construct a 3-bedroom single story dwelling and garage. Decks more than 30-inches above grade, measured 3-ft beyond the walking surface, shall require review and approval prior to construction. Storage or other space provided above the garage or dwelling with headroom height greater thna 7-0"shall be approved by the Mason County Building Department. Areas with more than 200-sq. ft. shall be provided with a stairway constructed in accordance with the code in effect at the time of construction. To obtain approval for changes, deck requiring a permit, and areas above the garage or dwelling submit a written request to the Mason County Building Department along with approved plans. Include SITE approved construction plans, floor plans, and framing plans that clearly identify proposed construction. X \ 26) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 27) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County S oreline Master Program. X C— 28) All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X C_ 29) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or properties. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X- 30) The applicant acknowledges that this development was sited such that further shore protection measures (low wall concrete bulkhead exists)will not be required for protection of the new structure. X �, BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 5 of 6 31) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X C— 32) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 33) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 34) Retaining walls needed to support a surchar a such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: d l.5 c- 2, BLD2013-00816 Please refer to the following pages for conditions of this permit. Page 6 of 6 60 y� o CONCRETE MECHANICAL MANUFACTURED HOME oFootings I tbac GatePiping By(tic.. Ribbons rn o Interior Date z//N/�� By, �;I Interior-Date /� ByLU, Date By 00 Exterior Date B Exterior-Date B N Point Load lisolated Footings INSULATION p By m BG I SLAB INSULATION Z Date By Data By FIRE DEPARTMENT ..� Foundation Walla Floors Date By Die"Z�l•I �vt By ! Data By DECKS FRAMING Walls Date By Date /"I By ��. Data f( I&J By ` X— PROPANE TANKS PLUMBING Vault Date By Date By OTHER _. Groundwork Attic Type: date By Date By Date By D_W.v DRYWALL Type_ By Int Brace Wall Qpw k o5 3 Date By (A v Date y Date By FINAL INSPECTION p Water Line Fire Seperatitxt IV Date By�lj Date By Date m W o Pass or Request Inspect, c s Type of Insp. Fail Date Date Done By Comments o C TO y on t t� /� •� �7 Z/ �f ✓ !� Gcc1 5 GCS��%-�l 7 a o' -� O'1 'l'�- — (e �t C-a.. S I D`n t ' tl Lk n (n / ° /i' � /t U — 7T CTVI S /1 N 40 rwt- ;I c 541cr-lo A-4 ;t-3�. *. 0 0 y MASON COUNTY BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 3176 6 9, X41-f 3,,Z This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been kound: Items listed below must be corrected to gain compliance ICY.- � 7.�•-� S,tl,l Lc dlb �L�.: 1 ✓' N / /�S"�h /� � � L�6.G.. 21 K- /i.%/.S 't YEN kJYi-) hp+r3 ,r'� 7G' '✓ILL �:� IIot You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Q Call for re-inspection when corrections are made before continuing Lj please contact our office Make corrections, items will be checked on next inspection regarding possible structural OK to (�ee�i C- � damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is NOT Date CORRECTION NOTICE. Department_ �' _ Inspector s 0 V NUT , MUV ' TH/ mak T A rmll Permit# MASON COUNTY BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location n6o g -<;' P-r This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been ,f0 nT Items listed below must be corrected to gain compliance 't► T I n T" 4 0 A IOTTZ o 42 - i Z ,A '7�i Lc ? C,,h d �'T Lc.'tw . You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made,before continuing ❑ please contact our office Make corrections, items will be checked on next inspection regarding possible structural © OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is_NOT a CORRECTION NOTICE. Date T J ) f'( Department Inspector 1/ voo NoT R iill �4 ; ' THIa Two AW " Permit # MASON COUNTY BUILDING /II 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 3gJ0 6 S>. /?-t 30z This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found' Items listed below must be corrected to gain compliance 4 A!, i4wcl 0kV,-1.,4 kUr "d b& 41p 61ot-i0- Z ha flit$ 4 T ,- A Le-,t-dr ( s'L '7J h S'rH t ✓�ST� �.7.1�.. c: GS u G.t1 �.� Ll Csv�s.t CiG• 1," It 1'-`S i i v Ti) F (,.j w t/ Gu gtfi►t 4-4k-, v Ar_c..cS s. o^tS --r14 CA vi* 4irew, , I -1� "i(.e C,<,, T You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Please contact our office ❑ Make corrections, it s will be checked on next inspection regarding possible structural ® OK to .r rk C) u damage incurred by recent "natural1man made" ❑This is not a complete inspection 77 disasters. This is_NOTa Date 5� / Department v CORRECTION NOTICE. Inspector Doi ,$ dOT PEiml� ,#V ' THIS TAa* qr Perm it /3 Q�'�!(v MASON COUNTY BUILDING III 426 W, CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location ` 0 6 S'f, �T This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance DeAe �.�.l�:.s Oaf 1 iti �"T'7e 7ii —�f 1/v► '1 v'C�.- .+•I lt'1.41d'� T,j l z.!'i.r.�i •L•u l�;.z,1i J%Jw� tr Y`.. - ;�'T i G .�c.r.J if C'-zr� �9 T �l-z�7',r.�=:..1 Ac...-►-c I ✓� ` C c+�,a-f -r,�-.-.. Gy-� You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑ This 1is no``t a complete inspection disasters.This is NOTa Date 7/- Department 1`'�^J CORRECTION NOTICE. Inspector 71�� f)sr v NnT , M9 ,0V THI _ T AOME Will Langemack Ltd 1115 Wing Point Way NE Field Change/Clarification Bainbridge Island, WA 98110 Walter Galitzki 2-7-2014 Sun Path Custom Construction Inc. 3460 No.Mission Road W. Bremerton WA 98312 Re: Roberts Job.No. 2013-290 Enclosure None Comments Responding to an inspection question/confusion, regarding the typical noting reinforcing, using 2#-4 as noted in reinforcing notes instead of 245 as shown in Detail 1 is permissible for standard foundation walls less than 48". This is consistent with IRC requirements and meet minimum Mason County standards. Any walls taller retaining earth or surcharge loads should use #5. Action For your use and records. Please contact may office if you have any questions or concerns From; Will Langemack, Architect Retired Pres/Will Langemack Ltd. 206-948.1076 [Voice/Message] will@langemack.com [email] -WBPA C&R 18f,5 � _ RECORD OF SUR VE Y jl -----w_(__ 't' LEGEND-- l I SITE �_� MASON COUNTY, WASHINGTON I IB a FOUND MONUMENT I —.._..�..c_.—__—_-__L _ __-___�p� O FOUND RE-BAR k CAP TOM 8P156 YQW IIFNT N"0'E-20SS�REC400 I — — 121 2 �.oDWeN N MIYIY E-2055e'YFA4AW8.. NORW WMIER CORNER ® SET MAG NAR&WASHER 4UGVSr 20011 \t I SEC 21,!T2 N.R I K W.Y. I _ FtwNo BRA,, • SET HUB'RE-BAR h CAP �� u SET HUB k TAfX o m r o SMNTARY LAG 21 — ~ CLEAN OUT n KFOR ROM ® „ELL Y W 1 I Faw BRASS M&AYIENr fQ ARY LdNF RESOLUTION a UnITY POLE AUWSi TDoa 1j \ \ SACIT TO RCW 58.04.007 x—X FENCE ^J 2 I I ff' I` SEE �ty u\la�l ASPoULT PA4EMENT 4 I I I \ A1/fED KN 201 b8910 ® GRAVEL CONCRETE 20 0 20 60 Ilcm VICWTY MAP Qf�/ \ I sGae!"_20 N I i' SCALE.' i'.114 ABLE SEC 21, T.22 N.,R. i W... W.M. I Ad I''o. TI EAST-166.0'(DEED) FOIRO EYEASaV RE-BM A,CAR r 10.. N 89 00'E-I57112' (\ LEGAL DESCRIPTIONS /� CONCREIF� SHED `! PARCEL N0.12221-21-00100 w, I A TRACT OF LAND IN GOVERNMENT LOT 1 SECTION 21,TOWNSHIP 22 NORT I RANGE 1 WEST, W.Y.,PARTICULARLY DESCRIBED AS FOLLOWS PARCEL NO. O j {� COMMENCING AT THE MEAAJER CORNER AT THE NORTHWEST CORNEA-0&�SAID \\ 12221-21-OOIW O1 Iyl I `l GOVERNMENT LOT 1;THENCE SOUTH 11'30'00"WEST ALONG BALD MEANDER LINK. 335.18 FEET TO A FOUND BRASS MONUMENT;THENCE SOUTH 42337 272.66 FEET TO THE TRUE POINT OF BEGINNING THENCE k01�f11 B2'47'17' j } 157.12 FEET TO THE WESTERLY MARGIN OF HIGHWAY 30�2(ALSO�XNOWN AS O 111 SECONDARY STATE HIGHWAY NO 14B,ALLYII-VIC70R�AD)ANe A""pOIr p0/ T . I/ CURVATURE 0F'A 1030.14-FOOT-RADIUS CURVE TO TNT I.'�FI'(HAD,U5 PQIAfy r r}I ,�' s I $ (`�ilvQ BEARS SOUTH 84'33'13'EAST);THENCE ALONG SAND CUR 17 If rTNROUOR h A CENTRAL ANGLE OF 06'2736;Tfigll ,SOUTH'BD'4T17" 1B0.01 FEET TO W Q,d • THE MEANDER LINE;THENCE NORTfI 04•$3'50'fIILST ALONG p�'YEANDER LINE, V O'^ = slAws a ® o BB 32 FEET TO THE TRUE PO4VT OF BEGINNING. J 2 m PARCEL N0. I2221-21-00080 -'�� w I 3480 1 \\ re 2a o ALL THAT PORTION OfTHE 50UTH 52 FEET OF\THE NORTH 760 FEET OF STAIRS I RESOD" W� COVERNMEIM LOT-1.9ECM0�!21"TOWNSHIP 22 NORTH,RANGE I WEST, M.M., WHICH II&WESTERLY,O TIIE,WESTERLY RIGHT-OF-WAY LINE OF SECONDARY rnlitRnE xwE IENCE 4 I 1 STATE{HG�!'WAY N0.3d$ 0,\Alf,TIDEGNDS OF THE SECOND-CLASS, 6YUrIWADS \IT EIEV I'ORYERL7(OWNED BY 111N ITC�Q3'WASHBfCTON,AS DEFINED BY CHAPTER 266 -u.1T h Tom. 7 I I ('OW T SXC770M LAWS OF 1 27.SITUATE IN FRONT OF,ADJACENT TO OIT / k1BUTTINQ UPON THE ABA DESCRIBED UPLAND,EXCEPTING THEREFROM ALL T PORTION.OF SAID TIDELANDS INCLUDED WITHIN A TRACT OF OYSTER LANDS 10.T—— —, ,-65eT— —— DEEOED BY'7Hf STATE GF WASHINGTON TO THOMAS O'NEHJ.AND A.L McDONALD, 1RDrx S Bg'4Y17'W IBCOI "` - DECEUR7 IBO�"UNDER APPLICATION NO.3001. EAST-Ie7.4S(DEED)" j RENSED LNE CRLWLLL LNE �. I. WIS SURI•F,Y 6'OMPUES WIN ALL STANDARDS AND q TALE "GlaO(ONES(Y or RECORLWlG AC!'OWAER qq1l[C Na BEITA RApUS M W $ I Q ` SB,09,RCW AN?, 2-130-090 WC 1222 RQLNO. CI OOUB 10 IOSQ 11 zoo V 1. SLWEY WAS ACCa PUSHED USING HERO TR41£RSE 21-00090 I .. Sq K CPS PROCFWRfS Of TABLE "5'A&OOWETER MODEL 610.J-SECOND TOM STAROV Z9 S 0 AND LDCA 12M GPS RECf11ER RERE USED FOY DRS SURIfY Nn DwECDON MSTANCE � ll N O4TS'SB E 201 fl a S49S OF WARWG:MASON CM NTY RECORD OF SIARVEY,WN 197697d taE.JZ PG I= lam — CnI AUDITOR'S CERTIFICATE SURVEYOR'S CERTIFICATE MA"ma"'1A a°nW B""" OAS:I1-15-13 °°=�s Aspen FILED FOR RECORD THIS'A I DAY Q•' 1A�L1lLCAC- 20�AT I I�Zlo M N, DVS MAP CQPR£CftY REPRESENTS A SURVEY r'LRSe , '� MADE BY ME OR UNDER MY DIREC17ON IN 41 A PORTION Of THE UNDER AUOlpYS FILE No. CONFORMANCE WTH THE REQUIREMENTS OF THE ^ �Oa I 1 '2 AE/4OFTF#NW/� a�.. Land Surveying W VOLUME�Q_ OF SURVEYS,PAGE.�S SURVEY RECOROINC ACT AT THE REQUEST C1r ) > J b SE(',11, T 2I N,R 1 W, W.M. AT THE REQUEST Of 6;!jM Laid 51M'/G(fhO LLG. RccoRswC FEE l,>' I a KfNT& IUL/A ROBERTS 2 Pfs Aeclets+e° v4 at TA.Len4/p in Bey Center LLC MASON COL.NTY, / ��� 1 SONAL LANOgg P.O.Box 124, Vaughn, WA B83B4-0124 13510 - 92ud Street, KPN, Gig Harbor.WA 98320 WAShWYGTON DEPUTY COU/STY AUDITOR `O1 (253) 303-0270 FAX(253)303-0273 Lp�I3 +Oo� 1yr ft' no rue Won w (IO ft, nominal on North Pt and 5 ft on 5outh PLj f i' shoreline setback_---_- ----Exist. Buildings - ?GI"Z j N 89°47'17" E 257.12' 25 ft Front yard Ca M �•�C) tom' — —— O g 64stI Existing Approach d Orive o Field modify to provide garage access ( I in 400 I Exist.boat ramp _ 1 I Exist,beck I 1 \ LL o Q Q to be grondfath ed , I � >= CV �0 Q 'S and repurpos I ; for new dwells I ; Proposed Dwelling ', U Cob +J I =� o N M 6_2 C.) a. o N _ N N 89047'17" E 160.17'V/4— i Exist. Buildings bashed li s indicate exist-buildings Exist. Buildings to be removed - Tor 31Ueyuru5 rcyulreu [ 10 ft. nominal on North PL and 5 ft on South PL] 5' shoreline setback--__ Exist. Buildings N 89047'17" E 157,12' T LLJ ,25 ft Front yard CO E g H , x o S Existing Approach& Drive I� o -------— --———;—-- -- Field modify to provide garage access ( f I M 00 Exist. boat ramp j l � ti —--- Cz -- ---=-- N ; • \ I ------ ------ Exist. Deck I � , v rn to be grandfath ed I J 1 and repurpos W W c 1 for new dwelli g I Proposed Dwelling ' I 1 Lr.r-� lA 1 (�( N 89047'17" E 160.17' i 1 I re. f 60'-0" ± 58`-0" ± 2'-2" Exist. Buildings -- Dashed His indicate exist-buildings Exist. Buildings to be removed - �GOV cou MASON COUNTY PERMIT NO. - y DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WAUS (360)427-9670 Shelton ext.352 Bldg. III,426 West Cedar Street Mason County g. (360)275-4467 Belfair ext. 352 r. txw PO Box 4 9,Shelton,WA 98584 (360)482-5269 Elma ext. 352 BUILDING PERMIT APPLICATION OWNER INFORMATION: I CONTRACTOR INFORMATION: NAME: Kent & Julia Fcberts NAME: Sun Path Custom Construction, Inc. MAILING ADDRESS: 143 S 163rd Lane MAILING ADDRESS:3460 N Mission Rd W CITY: Burien STATE: wA ZIP: 98148 CITY:Bremerton STATE: WA ZIP: 98312 PHONE: (206)853-7763 CELL: PHONE: (360)275-0774 CELL: EMAIL: EMAIL : sunpath@tscnet.com L&I REG# 489,127-01 EXP. 1 / 3 /14 PARCEL INFORMATION: " PARCEL NUMBER(12 DIGIT N-UNIBER) 1 2221-21-001 00 FIRE DISTRICT LEGAL DESCRLI'TION(ABR=-,-TATED): TR 10 of Goyt Lot 1&T.L. SITE ADDRESS 3490 E State Rt 302 CITY Belfair DIRECTIONS TO SITE ADDRESS Leaving Allyn, go east on Hwy 302. House on the right after overhead power lines IS PROPERTY WITHIN 200 FT: SALTWATER R LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO TYPE OF JOB: NEW Ld ADDITION ❑ ALTERATION ❑ REPAIR ❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) SFR w/attached garage IS USE: PRIMARY ® SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS .75 DESCRIBE WORK Remove i ng ahi n� tx�i 1 c3 nPw SF'R SQUARE FOOTAGE: VN 1ST FLOOR 1 ,895 sq.fL ?ND FLOOR sq.fL 3RD FLOOR sq.ft. BASEMENT sq.ft. Z DECK sq.fL CON EKED DECK 48 sq.fL STORAGE sq. ft. OTHER sq.ft. GARAGE 624 sq.ft ATTACHED] DETACHED l CARPORT sq. ft. ATTACHED ❑ DETACHED ❑ MANUFACTURED HOME nFORMATION: *4 COPIES OF THE FLOOR PLAN 1 MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER N OWNER/BUILDER admowl snr:assion of inaccurate cformation may result in a stop work order or permit revocation. Acknowledgement of such is by signatwe below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entbed to remove ffiis permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easemerit holder or parties of interest regarding this project.The owner or authorized agent represents that the C information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for _ review and inspection_This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if co st on work is suspend or a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTI I A nkTY r R IT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X 9/11/13 (vl S `n ure of plicank Date x Walter Galitzki OWNER REPRESENTATIVE /CONTRACTOR Print Name kC"IRCLE TO iNu,;;H i c) DEPARTMENTAL REVIEW-- APPROVED DATE DENIED DATE TAGS/NOTEStC©ND3TIQNS BUILDING DEPARTMENT .01 PLANNING DEPARTMENT FIRE MARSHAL C� f Q-0), 5b�1 � t-7 � -� � h t-7(2� X � l MASON COUNTY (360)427-9670 Shelton ext.352 DEPARTMENT OF COMMUNITY DEVELOPMENT (360)275-4467 Belfair ext. 352 BUILDING• PLANNING•FIREMA,-Sr' (360)482-5269 Elma ext. 352 Mason County Bldg. III,42c Wes~ --.ar St PO Box 279, Shelton,WA 98584 www.co.mason.wa.us 1854 PLUMBING & MECHAN1 1CAL PER-NUT APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Kent & Julia Roberts Company Name Sun Path Custom Construction Mailing Address 1,43 S 163rd Lane ' MaiTing Address 3460 N Mission Rd W City bur1en State WA Zip Code 98148 ! City Bremerton _,-X-I a Imo—25p Code-98312 Phone (�)RS 1-776R Other Ph. � Phone (360)275-0774 Other Ph. Lien/Title Holder Owners I Cantractor Reg.# -simpapc941 be Exp. 11 R/14 E mail address E Mail Address s (dtscnet-com Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION -Connect to New Sep E)dstina Septicc, Conmectto Sewer System Yes Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No 1 2221-21-001 00 Fire District Legal Description TR -10 of Govt Lot 1&T.L. Site Address(Please include street name, street rr,--per a: y) 3490 E State Rt- 302 Belfair Directions to site Leaving Allyn, qo east on Hwy 302, House on the right after overhead Is property within 200'of Saltwater�:es Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Biuffis > i5% TYPE OF JOB - New x Add—Alt—Repair Other Use of Building SEE Location of Fixtures/Units- I st Floor x 2nd Floor Basement Garaae x Cioset PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electiic x LPG_Natural Gas—Heat Pump X Toilets 2 Type of Unit No.of nits Fees Bathroom Sink Furnace Bath Tubs - 1 Heatpumps 1 Showers 1 Spot Vent Fan Water Heater 1 Propane Tank 1 Clothes Washer �_ Gas Outlets a, Kithen Sinks 1 Woodc-AasvPeliet Stove 1 Dishwasher 1 K►dher Exhaust Hood 1 Hosebibs 2 Dryer Vent 1 Other Other JBase Fee Bese Fee TOTAL PLUMBING' i v tAL MECHANICAL OWNER/BLM DER Acicmwiedges submission of ina=xa---' ray resat in a stop work order or perms revocation.Acknowiedgement of such is by signature below.I declare that i am the owner av�-i�s iega �,or the ca-&acmr P:,rpr declare that I am entitled to receive this permit and to do the work as proposed in the application.I d9dars t oba>e?=ie per rim trxn al the necessary parties.If pemnission is reauired from any easement holder or arty other party in ir,m regarslr-m aoi+r�n or t-re axk n the application,i have obtained permission m them tc apply for this permit and conduct me wax rr�� T_��or ar:�mr.�doff,represents that the information pro ' i� and grars}s er eesrof Cow:ac:�_ �oes=bed prop_ aric�a for review and inspection. PR OF dNUA' OF Ism OF A �i IO�L X 9 11 13 er Owne Representative r con or (mom w ate; FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bid?d Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED i NOTES Building Department i Occ Group T Constr. 1 Planning Department Environmental Health Department FEES Plumbing& Base Fee Site Inspection Mechanical.&Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Voiation Fee TOTAL FEES MASON COUNTY (360)427-9670 Shelton ext_352 ro��so� �'ap DEPARTMENT OF COMMUNITY DEVELOPMENT (360)275-4467 Belfair ext- 352 BUILDING PLANNING•FIRE MARSHAL (360)482-5269 Elma ext 352 Mason County Bldg. Ill, 426 West Cedar Street PO Box 279, Shelton,WA 98584 www.co.mason.wa.us 18 PLUMBING & MECHANICAL PEPMT APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Kent & Julia Roberts Company Name Sun Path Custom Construction Mailing Address-1 43 S 163rd Lane Mailing Address 3460 N Mission Rd W City Burien State WA Zip Code 98148 City Bremerton State W—Zip Code 98312 Phone (206)RS-4-7763 Other Ph. Phone (360)275-0774 Other Ph. Lien/Title Holder owners Contractor Reg.# srnc941bc Exp. 1/3/14 E mail address E Mail Address s mPathtaf-, t.com - Ddvers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septin Existing Septic Connectto Sewer System Yes Name of Sewer System PARCEL INFORMATION-12 Digit Parcel No 1 2221-21-001 00 Fire District Legal Description TR 10 of Gout Lot 1&T.L. Site Address (Please include street name,street number and city) 3490 E State Rt 302 Belfair Directions to site Leaving Allyn cio east on Hwy 302 House on the right after Qverheadlines. Is property within 200' of Saltwater des Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New x Add Alt Repair Other Use of Building SEE Location of Fixtures/Units- 1st Floor x— 2nd Floor Basement Garage x Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric x LPG_Natural Gas—Heat Pump X Toilets 2 Type of Unit No. of Fees Bathroom Sink Furnace 1 Bath Tubs 1 Heatpumps 1 Showers 1 Spot Vent Fan 3 Water Heater Propane Tank 1 Clothes Washer 1 Gas Outlets Kichen Sinks 1 Wood/GasfPellet Stove 1 Dishwasher 1 Kitchen Exhaust Hood 1 Hosebibs -2 Dryer Vent 1 Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BULDER Pclmowiedges submission of inaccurate h1ormation may result in a stop work order or permit revocation.Ac r E 1 such is by signature below.I declare that I am the owner,owners legal representative,or the contractor I further declare that I am ertbec to*�,re=s permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the rosary parties.If perr-Jssior.s required from any easement holder or any other party in interest regarding this application or the work proposed in the application,1 haw obtined pe7ission,ftpm them to apply for this pem-d and conduct the work proposed. The owner or agent on owners behalf,represents that t`;e irrorrr nr- PrOVE i and grants em eestof Courtly access to the above described property and structure for review and insp-oc ow- PR OF �IUATION OF R MEANS OF A PROGRESS INSPECTION. X Date- 9/11/13 er Owne Representative Contra or (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW J APPROVED DENIED NOTES Building Department Occ Grouo—Type Constr. Planning Department lA 1 Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical.&Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Vioiation Fee TOTAL FEES Exist. Buildings Administrative variance {,)r sideyards required 15 ft. nominal on North PL PLAi~ PLO ISIO and 5 ft on South PL] EIVED DATE 35' shoreline setbac I xist. Buildings I N 89047'17" E 157.12' 1 — -- -- — v (— i �tFront I co I 117 \ I h o N - M t OIL o Existing Approach& Drive N --- j Field modify to provide garage a,�cess PLANNING: - Exist. boat ramp I — �_— ALL SETBACKS ARE MEASURED ��- _--_-______� FROM THE FURTHEST --------- I - PROJECTION OF THE BUILDING j �l -- -- ------- o Exist. Deck to be gran ath ed I \ w �'f and repur ��ANNINtj for new dwel i I Proposed Dwelling i I ' V. / 1/2' Tit HD o l I APPROVED ' N 89°47'17" E 160.17' i I - MASON COUNTY DCD PLANNING I 2'-2 -- — ®-1 = ---- o SITE PLAN REQUIRED TO BE ON SITE 60'-0" ± 58'-0" ± " CH NGESSUBJECTTOAPPROVAL I By Date a Exist. Buildings Dashed li indicate exist buildings Exist. Buildings to be removed i 0 09-11 -13P02 : 45 RCVD i o I 0 20 40 60 80 100 FT I Schematic Site Plan i I Scale: 1" = 20 ft --————---———————— Parcel No. 12221-21-00100