Loading...
HomeMy WebLinkAboutMIS99-0718 Fire System - MIS Permit / Conditions - 10/20/1999 MASON COUNTY Mason County Bldg. 111 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 I V-',C-- F= L- t- A N U--- C3 kJ S P IE- R M I 'T FOR INSPECTIONS CALL 427-9670 MIS99-0718 PARCEL : 123301063000 PLAT - DIVt BLK : LOT : JOB ADDRESS : 791 NE SAND HILL RD BELFAIR APPLICANT : NORTH MASON SCHOOL DISTRICT 360-275-2883 OWNER : NORTH MASON SCHOOL DISTRICT 360-275-2883 LEGAL - E112 OF If EX PROJECT DESCRIPTION : AUTOMATIC FIRE ALARM PROJECT LOCATION : NORTH MASON S .D .791 NE SAND HILL ROAD PROJECT NOTES : TVpf" AMOUNT BY DATE RECEIPT IFIR2 50 .00 KW 10/28/99 0136 �FIR2 $ 50 .00 TMJ 11 / 12/99 0141 77 TOTAL : 100 .00 OWNER OR AGENT DATE ifts-PINT, rev, 14101192 COMPLIANCE TO ATTACHED CONDITIONS IS REOUIRED CONCRETE MECHANICAL MOBILE HOME 'Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by date by PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by • MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 PERMIT COND I T i C]N .S Case No . : MIS99-0718 For : NORTH MASON SCHOOL DISTRICT Page : 1 1 ) 1 . FINAL INSPECTION REQUIRED . SCHEDULE AT LEAST 24 HOURS IN ADVANCE X j._ONCriETE MECHANICAL MOBILE HOME rootings-Setback date by Ribbons date by Gas Piping date by Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by date by PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by r MASON COUNTY FI RE MARSHAL o Mason County Bldg. III 426 W. Ced P.O. Box 186 Shelton. Washington RL E C 0 P Y n ir,, (206) 427-9670 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATIOW PUBLIC EDUCATION PERMIT NO. M=" 17 0 '7l ? MASON COUNTY FIRE PROTECTION SYSTEMt� PERMIT APPLICATION 61 (0 NOTE: This application must be completed and accompanied by a minimum of three (3) copies of plans, specifications and applicable calculations per Mason County Fire Protection Standards and brought to the office of the Mason County Fire Marshal. This is not a permit, and failure to submit all necessary information will cause a delay and/or rejection of your submittal. When a permit has been issued, you will be notified. PLEASE PRINT #1 OWNER North Mason S.D. / Sand Hill E1qzEONg 360-275-6080 SITE ADDRESS 791 NE Sand Hill Road FIRE DIST. Belfair CITY Belfair STATE Wa, ZIP 98528 DIRECTIONS TO JOB SITE see attached OWNER MAILING ADDRESS P.O. Box 167 CITY Belfair STATE Wa. ZIP 98528 LIEN/TITLE HOLDER ADDRESS CITY #2 CONTRACTOR Sound Electronics CONTRACTOR REG # SOUNDE%',14OR3 ADDRESS 4621 Pacific Ave._ EXP. DATE 12 / 23 / 00 CITY Tacoma STATE Wa ZIP 98408-7739 #3 PARCEL # 12330 - 10 - 63000 LEGAL DESCRIPTION #4 BLDG. SQ. FT (EXISTING/PROPOSED) - 1ST FL 44 00 / 2ND / 3RD / BASEMENT / DECK / #BR #BATH GARAGE / CARPORT / ENCL ATTIC: Y N OTHER portable SQ FT 1 , 792 USE OF BUILDING #5 DESCRIPTION OF WORK: SPRINKLER: WET DRY STANDPIPE: WET DRY AUTOMATIC FIRE ALARM_X_ CORRIDOR SMOKES HOOD & DUCT DRY CHEMICAL WET CHEMICAL HALON NEW SYSTEM MODIFICATION NUMBER OF NEW DEVICES 10 MONITORING STATION PHONE #6 DOES YOUR SUBMITTAL INCLUDE: I. DIMENSIONS, SCALE, NORTH ARROW? YES X NO 2 . FLOOR PLAN AND CROSS SECTIONAL ELEVATION? YES NO_ N/A 3 . ALL CONCEALED SPACES (LABELED COMBUSTIBLE AND NON-COMBUSTIBLE) ? YES NO N/A 4 . ALL AREAS ON OPPOSITE SIDE OF NEW WALLS? YES NO_ N/A 5 . CUT SHEETS OR REFERENCES FOR ALL NEW DEVICES? YES X NO_ 6 . LOCATION/DESCRIPTION OF ANY EXISTING DEVICES YES X NO_ 7 . BATTERY CALCULATIONS FOR FIRE ALARM SYSTEMS? YES NO SEE LETT; 8 . RISER/WIRING DIAGRAM FOR FIRE ALARM SYSTEMS? YES NO X 9 . HYDRAULIC CALCULATIONS FOR SPRINKLER SYSTEMS? YES NO_ N/A NOTE: WORK MAY PROCEED ONLY IN ACCORDANCE WITH A VALID FIRE PROTECTION SYSTEM PERMIT ISSUED BY THE MASON COUNTY FIRE MARSHAL. A VALID PERMIT AND AN APPROVED SET OF PLANS MUST BE ON THE JOB SITE DURING .CONSTRUCTION AND MUST REMAIN THERE UNTIL A FINAL INSPECTION IS DONE BY THE MASON COUNTY FIRE MARSHAL. FAILURE TO OBTAIN A VALID PERMIT PRIOR TO WORKING ON A FIRE PROTECTION SYSTEM AND/OR FAILURE TO PROVIDE THESE PLANS AND PERMIT FOR THE MASON COUNTY FIRE MARSHAL MAY RESULT IN A CITATION AND FINE. OWNERS AFFIDAVIT I certify that I am exempt from the requirements of the Contrac- tors Registration Law RCW 18 .27, and am aware of the Mason County ordinance requirements for which this permit is issued and that all work will be done in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal . L OWNER .S DATE CONTRACTORS AFFIDAVIT I certify that I am a currently registered contractor in the State of Washington and I am aware of the ordinance requirements regulating the work for which the permit is issued and all work done will be in conformance therewith. No changes will be . made without first obtaining approval from the Mason County Fire . Mar BY I - DATE , � � NE Ne : ƒ � * � ƒ � ¥ / NC- M6; MRd � A � 51NE Sand q Rd,elwt w ® ® \ , « $ /.4 ƒ 6 J < ` u » �\ � � Q rs° 14 , 2ƒ & $ a �v ( U �f ƒ �� ƒ ! [ « ,mi%r § G2� ���, 1 SOUND ELECTRONICS October 18, 1999 4621 Pacific Ave.,Tacoma,WA 98408-7739 Tacoma:253.472.2955 Facsimile:253.472.2974 Mason County Fire Marshal Seattle:206.439.9647 426 West Cedar Shelton, WA 98584 Attention: Dave Salzar Regarding: Battery Calculations Dear Mr. Salzar, This is in reference to Sand Hill Elementary fire alarm permit application. Battery calculations cannot be provided for the following reason: 1. The addition of 4 new smoke detectors presents a load to the batteries (approximately 100 ten-thousandths of an amp each) that is below the threshold of the calculation formula and will not affect the standby capacity of the system in any material way. 2. The effect of the addition of these 4 new smoke detectors will have no measurable effect on the standby capacity of the existing system. If you have any questions, please don't hesitate to call. ie re and llison Sales Engineer Washington State Contractors License No.SOUNDE•140R3 A Division of Carl T.Madsen Inc. tv SOUND ELECTRONICS 4621 Pacific Ave.,Tacoma,WA SYSTEM SUBMITTALS 98408-7739 Tacoma:253.472.2955 Facsimile:253.472.2974 For Seattle:206.439.9647 SANDHILL ELEMENTARY NEW PORTABLES NE 791 SAND HILL RD. BELFAIR, WA 98528 Prepared For MASON COUNTY FIRE MARSHAL 426 WEST CEDAR ST. SHELTON, WA 98584 Index FIRE ALARM SYSTEM EQUIPMENT DRAWINGS Washington State Contractors License No.SOUNDE•140R3 A Division of Carl T.Madsen Inc. I� FIRE ALARM SYSTEM EQUIPMENT PART# DESCRIPTION PAGE# 2451 SMOKE DETECTOR 1 P241575 HORN/STROBE 2 BNG1 PULL STATION 3 HD604 HEAT DETECTOR 4 June 19, 1998 2451 1-125 2- re and 4- ire ONOTIFIER" Phot elect c 5 oke Detector A Pittway Company with optional thermal sensor Section: Conventional Initiating Devices GENERAL California State Fire The System Sensor 400 Series plug-in photoelectric smoke (YO U L� "� Marshal detectors are specifically designed to meet the stringent per- 7272-1209:131 formance requirements of industrial and municipal fire detec- tion/alarm systems. The design of these detectors empha- S911 CS308 sizes ease of installation and field maintenance. BSA F M FEATURES • Unique optical sensing chamber: 1232-88-SA 0Q1A0.AY -„sl4 — Superior signal-to-noise ratio. — Built-in signal processing. — 3.0% nominal sensitivity. • Removable cover for field cleaning. • Visible LED"blinks"in standby. • Sealed against dirt, insects, and back pressure. • Three-year limited warranty. • Field metering of detector sensitivity. , • Built-in magnetic test switch. • Low standby current. • Built-in tamper-resistant feature. 1 • Designed for direct surface or electrical box mounting. • 360'field viewing angle of the visual alarm LEDs • Insect-resistant screening (0.020"/0.508 mm openings). ' • Easy plug-in of the head to base. ° • SEMS screws for easy wiring. • Optional recess mounting. • Air velocity up to 3,000 feet(914.4 m) per minute. mm)octagonal or smaller box. Easy-to-wire screw terminals allow fast and simple field wiring of in,out,and remote annun- APPLICATIONS ciator connections. Use to contribute to life safety, fire protection, and property Consult NOTIFIER control panel specifications for the maxi- conservation. Photoelectric detectors are recommended in mum allowable loop resistance for the particular control panel areas where slow smoldering fires are likely to ignite. In areas to be used. where small combustion particles are usually present from To prevent wiring mistakes,observe polarities and make cer- forklift trucks, cooking stoves, etc., they are less likely than tain that each conductor is identified.A copy of Installation and ionization detectors to produce false alarms. Maintenance Instructions is packaged with each detector. For CONSTRUCTION AND OPERATION further information, refer to NFPA 72"Standard on Automatic All 400 Series photoelectric smoke detectors contain a unique Fire Detectors,"and to local Authority Having Jurisdiction. optical sensing chamber designed to sense the presence of A MOUNTING BASE SELECTION GUIDE is included on page smoke particles produced by a wide range of combustion 2 of this document. sources and meet the performance criteria designated by UL JUNCTION BOX SELECTION GUIDE: Box depth is contin- 268. A new custom integrated circuit incorporates signal pro- gent on base and wire size. Refer to National Electrical Code cessing to reduce false alarms and sample/hold circuitry to or local applicable codes for appropriate recommendations. provide easy field metering of sensitivity. Bases B401 and B401B can utilize a single-gang,3-1/2"(88.9 An additional key feature is the range of mounting bases, to mm) octagonal, 4" (101.6 mm)octagonal, or 4" square junc- meet a variety of applications. tion box. Bases B402B and B406B can utilize a single-gang, 3-1/2"octagonal,4"octagonal, 4"square, 50 mm, 60 mm, or INSTALLATION 75 mm junction box. Base B404B can utilize a 4"octagonal Model 2451 detectors are designed for systems use with NO- or 4"square junction box. TIFIER UL-listed control panels. For two-wire applications, GENERAL SPECIFICATIONS refer to the Device Compatibility Document. Easy to install and maintain,this detector is designed for direct surface mount- Operating voltage: mounting base dependent(see chart). ing (mounting bracket included), or mounting to a 4" (101.6 Standby current: 120 pA max.; 100 pA max.for thermal. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or ISO-9001 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information,contact NOTIFIER. Phone: (203)484-7161 FAX:(203)484-7118 Quality System Certified to ^ International Standard ISO-9001 1 J N OTI FI E R' 12 Clintonville Road,Northford,Connecticut 06472 Made in the U.S.A. DN-1217 — Pagel of 2 Sensitivity: 3.0%/ft. nominal. t-) Weight: 0.6 pounds(272 g.). H t-) Size: model 2451 is 2.4"(60.96 mm)high,2451TH is 2.9" OP77ONAL RA400Z OPTIONAL a (73.66 mm)high;4.0"(101.6 mm)diameter with unflanged RA40DZ t-i 2 3 ^a' t-) 2 3 bases, 6.2"(157.48 mm)diameter with flanged bases. 0 (_) W W 1 W 1Ir Construction: flame-retardant white Noryl®plastic. J Temperature: for 2451, 32*F to 120°F (0°C to 49*C); for W WI LU 0 thermal model 2451TH, 32*F to 100*F(0°C to 38°C). Alarm point,thermal: 135*F(57*C),or 15*F/min.rate-of- M W rise. ----------- Humidity range: 10%to 93% RH (non-Condensing). ___________OPTIONAL FAULTTOLE RAN T WIRING-- Airvelocityrating: 3,000 feet per minute(15 meters/sec.). A B401B/B401 Wiring Diagram PRODUCE LINE INFORMATION EOLPOWER SUPERVISION Model Description RELAY,A77-7168 2451 Photoelectric Detector. Must be mounted to (+) RED (+) one of the B40 B Series Bases listed above. PURPLE 2451TH Same as model 2451 above, but with a 135°F (57°C)fixed-temperature heat sensor. RA40OZ Remote Annunciator for 2- or 4-wire applica- RAaooz RAaooz tions. Use with any 400 Series plug-in detec- (OPTIONAL) (OPTIONAL) tor. Fits standard U.S. single-gang electrical () \ (-) () box. 3 3 EILK MOD40OR Field Test Module for all of the System Sensor (+)2 140 coM (+ 2 140 COM o 400 Series Smoke Detectors. 1723 N O 1D'230 N. w¢ () a C. AUXILIARY AUXILIARY w 120 VAC 120 VAC CONTACTS CONTACTS 9 cc RA400Z B a B(9 �qC (OPTIONAL) O () () ALARMCIRCUIT "so 2®® 2®® B402B Wiring Diagram ¢Q 1130 COM 1190 COM 1 12 0 N.C. 12 0 N.C. W 087 91010 N.O. (+) 0067 111 N.O. 8 AUXILIARY 8 AUXILIARY - ---- FORM C FORM C (+) CONTACTS CONTACTS EOL SUPERVISION CIRCUIT RESISTOR 0 3 3 o n 2 I� 2 �4 ------------- w¢ 1® 14 COM T 1® 1< COM 13 N.0 13 N, 12 N.O. 12 N.O. AUX. AUXILIARY CON- ALARM CONTACTS COW CONTROL TACTS PANEL ALARM CIRCUIT (-) ----------------- ----- ---- --------' OPTIONAL NFPA CLASS"A"WIRING j B404B Wiring Diagram ------- -- B406B Wiring Diagram MOUNTING BASE SELECTION GUIDE Base Current Alarm Current Model Version Loop Limit Contact Nominal Standby Draw Cover Number Type Resistor Type Voltage Voltage on Alarm 6401 & UUULC/ 2-wire* No — 12/24 VDC 8.5 to 35 10 to 100 B401B EN-54 VDC mA** B402B UL&ULC 4-wire Yes Form-A&-C 24 VDC 17 to 32 14 to 39 VDC mA Screen 64046 UL&ULC 4-wire. Yes Supervisory Form-A&-C/A 120 VAC 120 VAC 75 mA AC maximum B406B UUULCI 2-wire* No Form-C 24 VDC 15 to 32 12 to 100 EN-54 VDC mA** *Functionality contingent on panel compatibility. **Must be limited by control panel. Detector RELAY CONTACT RATINGS: resistive or Inductive(60%power factor)load. Form-A: 2.0 A at 30 VAC/DC. Form-C: 0.6 A at 110 VDC;2.0 A at 30 VDC; 1.0 A at 125 VAC;2.0 A at 30 VAC. Page 2 of 2 — DN-1217 September 16, 1998 J-89 NOT 1 F 1 E W SpectrAlert TM Series FIRE SYSTEMS Horns, Strobes, and Horn/Strobes A PITTWAY COMPANY Section: Audio/Visual Devices GENERAL System Sensor SpectrAlert Series strobes,horns,and combina- -4 S4011 &S5512(P1215,P121575,P2415, tion horn/strobes are UL listed for primary signaling in life safety �L P241575,P2475,P24110). S5512(S1215, systems and meet ADA public mode visible signaling requirements. ® S121575,S2415,S241575,S2475,S24110). SpectrAlert products can be connected to the alarm indicating cir- S4011 (HC12/24). cuit of a fire alarm control panel and are compatible with DC line � CS549(P2415A,P241575A,P2475A,P24110A, supervision. The SpectrAlert product line mounts to standard S2415A,S241575A,S2475A,S24110A). backboxes using a universal mounting plate included with each unit. CS548(1-112/24A,HC12/24A). An optional small footprint mounting plate fits to a single-gang box. An accessory backbox skirt gives a cosmetic finish to a 4" x 4" x 1-1/2" or a 2" x 4"x 1-7/8" surface-mounted backbox. All strobe 0B8A4.AY(P1215,P121575, ► F M and horn/strobe mounting options require only one screw attach- P2415,P241575,P2475,P24110, ment of product to plate. S1215,S121575,S2415,S241575, These products are designed for 12 and 24 VDC and full-wave rec- S2475,S24110,H12/24). OD4A7.AY(HC12/24). tified unfiltered power. Full-wave rectified operation requires more current than DC operation. For detailed current draw information, 7135-1209:173(P1215,P121575,P2415, consult the Current Draw Tables (page 2). The horn/strobe com- P241575,P2475,P24110). bination products are factory-assembled with jumper wires for in- ' 7125-1209:174(S1215,S121575, tandem operation. For independent wiring of horn and strobe, re- S2415,S241575,S2475,S24110). move jumper wires. When wired for independent operation, the California 7135-1209:143(1-112/24,HC12/24). strobe will continue to run while the horn can be silenced. How- State Fire ever, the strobe must be running for horn to operate. Marshal V 1�AEA -4 319-96-E(P1215,P121575, Horns - The SpectrAlert Series horns and horn/strobes pro- /�-� P2415,P241575,P2475, vide two different field-selectable/reversible tones,a high-low field- P24110,S1215,S121575, selectable/reversible sound output setting (low setting on 24-volt S2415,S241575,S2475, models only) and a field-selectable/reversible temp 3 pattern or . .............. S24110,H12/24,HC12/24). i�INUi�r,ir wwr�A _ non-temporal continuous pattern. These field-selectable features are accomplished using pins and jumpers located on the back of each SpectrAlert horn and horn/strobe. An accessory module is not needed to make these field selections. The horn on horn/strobe models will operate on a coded power supply. Those horn-only models with "HC"in their part numbers will also operate on a coded power supply. The horn and horn/strobe series includes weatherproof models. ilu�fitliurm uY(ie�,if9il�" Strobes - The ADA-compliant SpectrAlert strobes are elec- tronic visible warning signals that flash at 1 Hz over their operating I�ybtii voltage range. These products are available in 24-volt models at 15, 15/75,75 and 110 candela intensities and in 12-volt models at 15 and 15/75 candela intensities. The strobe series includes weath- erproof models. SpectrAlert products feature dramatic reductions in current requirements. Sync-Circuit Module (MDL)-The Sync-Circuit Module is available for synchronization of strobes and horns and can syn- chronize two Style Y (class B) circuits or one Style Z (class A) circuit. The module can also generate a synchronized temp 3 tone for System Sensor's Multi-AIertTM and PA400 horn products.' The synchronization module allows the SpectrAlert horns on combina- tion horn/strobes to be silenced on two-wire systems. SpectrAlert's Sync-Circuit Module can be daisy-chained for multiple zone syn- chronization. The module does not operate on a coded power sup- ply. 'For Multi-Alert and PA400: Strobes must be wired to a continuous SpectrAlertTM,Sync•CircuitTM,and Multi-AIertTM are trade- source of power(non-coded power supply). marks of System Sensor, a division of Pittway Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or ISO-9001 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing MEE more information,contact NOTIFIER. Phone:(203)484-7161 FAX:(203)484-7118 Quality System Certified to �J N OTI FI E R One Fire-Lite Place,Northford,Connecticut 06472 International Standard ISO-9001 Made in the U.S.A. DN-5939 - Page 1 of 6 FEATURES Single-gang mounting without the use of a mounting plate • 24-volt strobe models: 15, 15/75,75 and 110 candela. (horn model only). • 12-volt strobe models: 15 and 15/75 candela. Self-contained screw covers. • Horn models operate on 12 and 24 volts. Aesthetically pleasing design. • Low current draw: reductions as high as 45%. Synchronize horn and strobe with Sync•CircuitTM module (MDL). • Two field-selectable/reversible horn tones: Silence horn on horn/strobe over a single pair of wires using — 3000 Hz interrupted — electromechanical a Sync-Circuit module(MDL). • Field-selectable/reversible high-low dBA output on horn *Sound output varies with tone and output options selected;sound (low output on 24-volt models only): levels based upon anechoic room measurements. — 101 peak dBA @ 10 ft. high output.* — 96 peak dBA @ 10 ft. low output.* SPECIFICATIONS • Field-selectable/reversible temp 3 pattern or non-temp 3 con- Input terminals: 12 to 18 AWG (3.25 mm'to 0.51 mm2). tinuous pattern on horn. Dimensions: see diagrams page 3. • Horn/strobe can be wired either in tandem or independently. • Weatherproof strobes, horns, and horn/strobes available. Weight, horn only: 7.2 oz. (204 g). • Horns for use with coded power supply available. Weight, strobe and horn/strobe: 8.8 oz. (250 g). • Universal mounting plate included with each unit. Mounting: see diagrams page 4. • One-screw mounting of strobe and horn/strobe to mounting Operating temperature: 32'F to 120OF (0°C to 490C). plate. Operating voltage range:** 12 V: 10.5-17 V. 24 V:20-30 • SpectrAlert strobe and horn/strobe take up no room in the V. backbox. ** These products should be operated within their rated voltage range. UL does, however, test functional integrity to -20% and +10%of manufacturer's stated ranges. CURRENT DRAW TABLES Strobe Only AVERAGE CURRENT(mA) PEAK CURRENT(mA) IN RUSH CURRENT(mA) 12V Models 24V Models 12V Models 24V Models 12V Models 24V Models 10.5V 12V 17V 20V 24V 30V 10.5V 12V 17V 20V 24V 30V 10.5V 12V 17V 20V 24Y 30V Candela DC MR DC MR DC MP DC MR DC MR DC MR DC �WR DC MR DC MR DC MR DC MR DC MR DC MA DC MR DC MR DC MR DC MR DC MR 15 WNANA 14 157 81 128 59 120 53 80 46 79 460 460 450 460 120 480 1. 2711 1. 210 110 250MNA 124 140 190 170�230220. 2B0 270 370 15n542 171 99 150 78 92 66 83 56 132 490 520 490 526 660 480 170 270 170 270 160 270 126 180 185 170 270 270 360 75 A NA NA NA 145 170 123 159 102 141 NA NA NA NA NA NA 350 440 340 460 330 480 NA NA NA 190 280 290 380 110 A NA NA NA 169 220 140 191 115 174 NA NA NA NA NA NA 460 560 450 570 420 620 NA NA NA 190 290 290 370 Horn Only AVERAGE CURRENT(mA) 12V Models 24V Models_ High/Low Temp 10.5V 12V 17V 20V 24V 30V Tone Volume Mon x MR DC MR DC MA DC MR DC I MR DC I MA Electro- High Temp 10 11 10 101 14 14 19 21 251 18 291 26 mach. Non 10 16 10 191 14 25 17 29 23 34 30 42 Low Tamp NA NA NA INA NA NA 11 12 13 13 17 15 Non NA NA NA NA NA 12 i6 14 19 17 24 3000 Hz High Tem 11 13 11 16 16 24 26 28 23 37 33 Interrupt. Non 11 17 11 14 28 19 34 27 39 35 45 Low Tam NA NA NA NA NA 14 14 17 15 21 19 Non NA NA NA NA NA 13 1B 16 21 22 25 Horn/Strobe - 15 cd Horn/Strobe - 75 cd AVERAGE CURRENT(mA) AVERAGE CURRENT(mA) 12V Mods 24V Models 12V Models 24V Models High/Low Temp 10.5V I 12V 17V 20V 24V 30V High/Low Temp 10.1V I 12V 17V 20V 24V 30V Tone Volume Mon x MR Dc MR DC MR DC MA DC MR Dc Mn Tone Volume /Non DC MR DC MR DL MR DC FWR DC I Mn or MR Electro- High Tern 1431 1701 124 1671 951 1421 781 101 78 98 75 141 Electro- High Temp NA NAI NA NA I NA NA 1641 1911 1481 167 131 167 mach. Non 1431 1701 124 167 95 142 69 98 76 100 76 136 mach. Non NA NA NA NA NA NA 163 188 1461 169 132 169 Low Tem NA NA NA NA NA NA 70 92 86 83 83 132 Low TempNA NA NA NA NA NA 156 182 136 162 119 156 Non NA NA NA NA NA NA 71 92 67 93 63 132 Non NA NA NA NA NA NA 157 182 137 162 119 157 3000 Hz High Tem 144 172 125 168 97 144 83 106 81 103 83 146 3000 Hz High TeMP NA NA NA NA NA NA 1691 196 151 172 1id Interrupt. Non 141 173 125 161 95 146 78 102 80 106 81 142 Interrupt. Non NA NA NA NA NA NA 164 192 150 175 1 Low TO NA NA NA NA NA NA 73 94 70 95 67 13 Low TempNA NA NA NA NA NA 159 184 140 164 1NA NA NA 72 92 89 94 88 132 Non NA NA NA NA NA NA 158 188 139 163 1 Horn/Strobe - 15/75 cd Horn/Strobe - 110 cd AVERAGE CURRENT(mA) AVERAGE CURRENT(mA) 12V Models I 24V Models 12V Models 24V Models High/Low Tamp 10.5V I 12V 17V 20V 24V 30V High/Low Temp 10.5V 12V 17V 20V 24V 30V Tone Volume /Non x MR DC MR DL PWR DC MR DC MR x MR Tone Volume /Non DC MR M IIIMR OC MR OC MR DC MR x MR Electro- High Temp 178 1931 1521 1811 113 1641 951 1131 911 111 87 153 Electro- High Temp NAI NAI NAI NAI NA NA 188 241 165 209 144 200 mach. Non 178 193 152 181 113 164 93 110 89 113 88 150 mech. Non NA NA NA NA NA NA 186 238 183 211 145 202 Low Temp NA NA NA NA NA NA 87 104 78 106 75 144 Low Tem NA NA NA NA NA NA 180 232 153 204 132 189 Non NA NA NA NA NA NA 88 104 80 106 75 144 Non NA NA INA INA NA NA 181 232 154 204 132 190 3000 Hi High Temp179 195 152 183 115 166 100 118 94 116 95 158 3000 Hz High Tem NA NA NA NA 193 246 168 214 152 207 Interrupt. Non 179 196 152 183 113 168 95 114 93 119 93 154 Interrupt. Non NA NA NA NA 188 242 167 217 150 210 Low TampNA NA NA NA NA NA 90 106 83 108 79 146 LOW TempNA NA NA NA 183 234 157 206 136 193 Non NA NA NA NA NA NA 89 104 82 107 80 144 Non NA NA N11 NA 182 232 156 205 137 195 Page 2 of 6 — DN-5939 ENGINEERING SPECIFICATIONS Horn/Strobe Combination—Horn/strobe shall bea General — SpectrAlert horns, strobes and horn/strobes System Sensor SpectrAlert model listed to UL 1971 shall be capable of mounting to a standard 4" x 4" x 1-1/2" and UL 464 and shall be approved for fire protective service. (10.16 x 10.16 x 3.81 cm)backbox or a single-gang 2"x 4"x Horn/strobe shall be wired as a primary signaling notification 1-1/2" (5.08 x 10.16 x 3.81 cm) backbox using the universal appliance and comply with the Americans with Disabilities Act mounting plate included with each SpectrAlert product. Also, requirements for visible signaling appliances,flashing at 1 Hz SpectrAlert products, when used in conjunction with the ac- over its entire operating voltage range. The strobe light shall cessory Sync-Circuit Module, shall be powered from a non- consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility coded power supply and shall operate on 12 or 24 volts. 12-volt rated devices shall have an operating voltage range of options(at 24 volts)and the option to switch between a tem- poral 3 pattern and a non-temporal continuous pattern. Strobes 10.5- 17 volts. 24-volt rated devices shall have an operating shall be powered independently of the sounder with the re- voltage range of 20-30 volts. SpectrAlert products shall have moval of factory-installed jumper wires. The horn on horn/ an operating temperature of 32°F to 120°F(0°C to 49°C)and strobe models shall operate on a coded or non-coded power operate from a regulated DC or full-wave rectified, unfiltered power supply. supply. Horn— Horn shall be a System Sensor SpectrAlert model Module—Module shall be a System Sensor Sync-Circuit capable of operating at 12 and 24 volts. Horn shall model listed to UL 464 and shall be approved for be listed to UL 464 for fire protective signaling systems. The fire protective service. The module shall synchronize horn shall have two tone options,two audibility options(at 24 SpectrAlert strobes at 1 Hz and horns at temporal 3. Also,the volts) and the option to switch between a temporal 3 pattern module shall silence the horns on horn/strobe models, while and a non-temporal continuous pattern. The horn-only model operating the strobes,over a single pair of wires. The module shall NOT operate on a coded power supply except those shall be capable of mounting to a 4-11/16" (119.0625 mm) models (model numbers contain"HC")designed to do so. square x 2-1/8"(53.975 mm)deep backbox and shall control two Style Y(class B)or one Style Z(class A)circuit. Module Strobe — Strobe shall be a System Sensor SpectrAlert shall be capable of multiple zone synchronization by daisy- model listed to UL 1971 and be approved for fire chaining multiple modules together and resynchronizing each protective service. The strobe shall be wired as a primary other along the chain. The Module shall NOT operate on a signaling notification appliance and comply with the Americans coded power supply. with Disabilities Act requirements for visible signaling appli- ances,flashing at 1 Hz over the strobe's entire operating volt- 2-15/16" 15/16" age range. The strobe light shall consist of a xenon flash tube �(74.6125 min) (23.8125 mm) and associated lens/reflector system. O DIMENSIONS 3-3/8" 5-5116" (85.725 mm)�I (134.9375 mm) O OO (142.875 mm) 1-5/16" (33.3375 mm) UPPER LEFT: Horn/Strobe with Small Footprint Mounting Plate (same dimensions for strobe only). LOWER LEFT: Horn/Strobe with Universal Mounting Plate IF (same dimensions for strobe only). �t2-5/16' UPPER RIGHT: Horn only(maybe mounted with either Small (58.7375 mm) Footprint or Universal Mounting Plate). 2-15/16" LOWER RIGHT: Sync-Circuit Module(MDL). (74.6125 mm 2" (50.8 mm) 5-1/4"(133.35 mm) RT7 OUTER: 5-518" O O (142.875 mm) O 0 INNER: 5-5/16" (134.9375 mm) 5-1/4" (133.35 mm) 6IF IF O Ll O 5" f 2-5/16" O O r---(127 mm) (58.7375 mm) DN-5939 — Page 3 of 6 MOUNTING DIAGRAMS 4"x 4"x 1-1/2"backbox Horn Surface Mount 2"x 4"x 1-7/8"backbox \ fie® BBS with accessory Horn Backbox Skirt Direct O O Mount O O b O ®® ®® D-MP Horn with Universal Mounting Plate ® \ (included with each product) OO m.f • 2"x 4"x 1-7/8"backbox O S-MP ® O � B 4"x 4"x 1-1/2" ® ® O backbox ® tj /4"x 4" 1-1/2"backbox ®®® Strobe or Horn/Strobe with OUniversal Mounting Plate 0 0 (included with each product) Strobe or Horn/Strobe with accessory Small Footprint 0 0 0 � Mounting Plate 4"x 4"x 1-1/2"backbox 4-11/16"x 4-11/16"x 2-1/8" (119.0625 x 119.0625 x 53.975 mm)backboxPro O O � � O � OO Sync•Circuit Module Direct Mount Strobe or Horn/Strobe Surface Mount with accessory Backbox Skirt SOUND OUTPUT GUIDE (dBA) UL Reverberant Room dBA @ Volts DC Anechoic Room Peak dBA @ 10 ft./VDC 10.5 12 17 20 24 30 10.5 12 17 20 1 24 30 LOW Electromechanical NA NA NA 75 75 79 NA NA NA 94 96 98 Temporal TONE 3000 Hz Interrupted NA NA NA 75 79 79 NA NA NA 94 96 98 HIGH Electromechanical 75 75 79 82 82 82 94 95 98 100 101 102 TONE 3000 Hz Interrupted 75 75 79 82 85 85 94 95 98 100 101 102 LOW Electromechanical NA NA NA 79 82 85 NA NA NA 94 96 98 TONE 3000 Hz Interrupted NA NA NA 82 82 85 NA NA NA 94 96 98 Temporal HIGH Electromechanical 79 79 85 85 88 88 94 95 98 100 101 102 Temporal TONE 3000 Hz Interrupted 79 82 85 88 88 90 93 95 98 100 101 102 Page 4 of 6 — DN-5939 WIRING DIAGRAMS NOTE: Do NOT loop wires under terminal screws. Independent Operation Tandem Operation FACTORY HORN AND STROBE INSTALLED HORNS HORN/STROBE COMBO JUMPER WIRES (_) REMOVED ® (+) TO NEXT < (_) HORN (-) OR EOL < ® NOTE: Strobes must be TO NEXT (+)TO NEXT ® ,® powered for horn operation. DEVICE (+) - STROBES OR EOL ® ® (-) MODULFA CP,E OR STROBE {r< (_) FROM FRCP, MODULE 0 FACTORY M PREVIOUS OR EOL `< (') PREVIOUS INSTALLED j DEVICE JUMPERS (A NOTE: Break wire as shown DEVICE for supervision of connection. DO NOT allow stripped wire leads to extend beyond switch (+) HORN HORN/STROBE STROBE ONLY housing. DO NOT loop wires. O M M L H H O O E R R O IN N L Two-wire system,any mix of models, wired for TANDEM OPERATION. iC O . Horns silenced over two-wire circuit. M B • Any mix of horn/strobes or strobe-only devices is M !o acceptable. s (+) S (+) • Horn control connects to interruptible power T T e R R O source. O O L MODULEI B B FACP el I.I HORN ZONE 1 II.1 I-I CONTROL OUT l-) TO NEXT Four-wiresystem,combo models, T pectrAlert wired for INDEPENDENT OPERATION. DEVICE NACt1) i•I ZONE 1 ZONE 2 I(q OR EOL (I�Om Can be turned Off at the pall@I (-) "I I" O1R l`"1R > while strobes continue to operate.) NACI2) i i\ZONE 2 TROUBLE(O TYPES OF 1 SpectrAlert Horn Only . Temp 3 coding of Multi-Alert Horn/Strobe •;}IN Bua Strobe only and PA400 sounders. NOTE: Strobes must be powered from non-coded TEMP JUNIPER OFF supply. MODULE 2 FACP M2 77 >TO NEXT MODULE 1 1-1 CONT"ORNROL ZOOUT I-1 S ctrAlert HORN ZONE 1 1.1 > I�l f DEVICE 1 CONTROL OUT a NAC 1 (•11 ZONE 1 ZONE Z L(•, OR EOL FACP O ALERTmuLTI_ TO NEXT 1-) IN OUT (-1 ALERT DEVICE (-) > I•I ZONE/ ZONE 2 I(•I ONLY OR EOL (+) O > NAC 1 1-I IN OUT 1-1 I•I ZONE 2 (.1 > NAC 2 (_( IN TROUBLE 1�1 TO NEXT (-) O SpectrAlert p > HORN ONLY NAC 2 1•I ZONE 2 TROUBLE1.1 p DEVICE I-I IN 0 MULTF (O7 SLAVE SLAVE J(.1 OR EOL ALERT TO NEXT (1 IN OUT 1-1 .PA/00 DEVICE HORN • Q suvE SuvE ONLY OR EOL TEMPJUNIPER OFF All SpectrAlert Io IN Our o > 7home,strobes will • • Horns will be and ate in s nc. — TEMP.JUMPER ON temporal-coded operate in sync. and in sync. DIAGRAM NOTES: 1) Any mix of SpectrAlert horn/strobe, strobe-only, or horn- only devices is allowable for Zone 1. 2) No devices or horn-only are allowed on Zone 2. If no de- vices are installed on Zone 2, terminate EOL resistor at horn control terminal. DN-5939 — Page 5 of 6 Z RED WHITE voltage candela avg.mA'@ avg.mA•@ O nom.VDC nom.FM_ P1215 P1215W 12 15 124 167 F Horn/Strobes P121575 P121575W 12 15175 152 181 P2415 P2415W 24 15 78 98 P241575 P241575W 24 15/75 91 ill P2475 P2475W 24 75 148 167 P24110 P2411OW 24 110 165 209 O 0 P241575K(weatherproof) — 24 15/75 91 ill N6 P2475K(weatherproof) — 24 75 148 167 P24110K(weatherproof) — 24 110 165 209 P2415A P2415WA 24 15 78 98 W P241575A P241575WA 24 15175 91 ill P2475A P2475WA 24 75 148 167 � Canadian Models, J Horn/Strobes P24110A P24110WA 24 110 1 165 207 P241575KA(weatherproof) — 24 15/75 91 ill VP2475KA(weatherproof) — 24 75 148 167 W P24110KA(weatherproof) — 24 110 165 209 Spanish Labeling, HIS P241575F(FUEGO) 24 15/75 91 ill in OS1215 S1215W 12 15 114 157 Strobes S 121575 S 121575W 12 15175 142 171 N S2415 S2415W 24 15 53 80 a S241575 S241575W 24 15/75 66 93 S2475 S2475W 24 75 123 149 S24110 S2411OW 24 110 j 140 191 S241575K(weatherproof) — 24 15/75 66 93 S2475K(weatherproof) — 24 75 123 159 S24110K(weatherproof) — 24 110 140 191 S2415A S2415WA 24 15 53 80 S241575A S241575WA 24 15/75 66 93 S2475A S2475WA 24 75 123 149 Canadian Models,Strobes S24110A S24110WA 24 110 140 191 S241575KA(weatherproof) — 24 15/75 66 93 S2475KA(weatherproof) — 24 75 123 149 S24110KA(weatherproof) — 24 110 140 191 Spanish Labeling,Strobes S241575F(FUEGO) 24 15/75 66 93 H12/24 H12/24W 12124 NA 12/23 12/21 Horns H12/24K(weatherproof) — 12/24 NA 12/23 12121 HC12/24(coded power) HC12/24W(coded power) 12124 NA 12/23 12/21 HC12/24K(weatherproof, 12/24 NA 12/23 12/21 for coded power) — H12/24A H12/24WA 12124 NA 1 12/23 12 121 Accessories H12/24KA(weatherproof) — 12/24 NA 12/23 12/21 1W HC12/24A(coded power) HC12124WA(coded power) 12/24 NA 12/23 12/21 MDL MDLW 12/24 NA 16 24 Sync-Circuit Module MDLA MDLWA 12/24 NA 16 24 Small Footprint Mounting S-MP S-MPW NA NA NA NA Plate for Single-Gang ONLY Surface-Mount Backbox Skirt BBS BBSW NA NA NA NA Universal Mounting Plate D-MP D-MPW NA NA NA NA (replacement) Weatherproof Backbox WBB — NA NA NA NA NOTES: 1) Canadian model numbers end in"A". 2) Latin American model numbers end in"F". 3) All weatherproof models must use weatherproof backbox model WBB. 4) All SpectrAlert products are designed for wall-mount only. 5) Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec.2.2). However,it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. 6) All 15/75 candela strobes or horn/strobes are recommended for 20'x 20'rooms or less. 'For a complete listing of SpectrAlert current require- ments, please refer to the Current Draw tables on page 2 of this document, or the Instruction Manual. Horn and horn/strobe current draws assume the horn is set at Temp 3, electromechanical tone, and high audibility. Page 6 of 6 — DN-5939 3 February 26, 1997 1440 ONOTIFIERO BNG & BRG Series A Pittway Company Manual Fire Alarm Stations Section:Conventional Initiating Devices GENERAL M EA The BNG and BRG Manual Fire Alarm Pull Stations each u L� F M 38-93-E' provide a single-action, normally open contact, alarm initi- (V ating point for use with Fire Alarm Control Panels. The S692 CS119 0A0A3AY BSA BNG Station is non-code,non-break-glass type. The BRG 750-76-SA' Station is non-code, break-glass type. (BNG-1RC only) California ADA `See page 2. FEATURES State Fire Meets ADA Pull Force • Within ADA 5 lb. pull force. ;Uj Marshal • Sturdy metal construction. 7150-0028:003 • Simple operation. Operation does not require replacement of parts (BNG y) PULL • Drawing of flames on cover helps communicate pur- pose of this device to people who do not read. • Designed to prevent false alarms when bumped,shaken or jarred. �. r • Spanish version (FUEGO) (BNG-1SP). The BNG-1TSL • Meets UL 38 Standard for manually actuated signaling and BNG-1 TSRL boxes. 1 APPLICATIONS Designed for indoor use in atmospheres which are not po- tentially explosive. Use as a means of allowing anyone on the premises to turn in non-coded alarm quickly without FIRE chance of error. There is no need for delay. There is no ALARM danger of giving incorrect or incomplete instructions. Typi- cal users include: &NOTIFIER- 1. Schools. 2. Hospitals. The attractive design of the station highlights its engineered 3. Retail stores. simplicity and unusual dependability; bumping, shaking, 4. Industrial plants. or jarring will not activate the switch or circuit. Instructions 5. Warehouses. for operation of the station are provided on the front of the Compatible with any appropriate control panel.May be used pull cover. The BNG and BRG Stations are both die-formed to: from 1/8" thick satin-finish aluminum, with the operating instructions in raised letters. Stations come in surface 1. Initiate local alarm signals. mounting models only. BNG and BRG contacts are rated 2. Trip a municipal fire alarm box. at: 1 amp., 30 VAC, and 30 VDC. The master key fits all 3. Start fire pumps. stations used in an installation of the same series. 4. Initiate other functions which can be initiated by the closing. INSTALLATION OPERATION The station mounts with two screws (supplied)to a stan- dard single-gang electrical switch box. It can also be The stations are operated by a pull on the pull cover. This mounted to a surface-mount box. causes a key latch to act against a retaining mechanism until adequate force is applied to open the station. As the ARCHITECT/ENGINEERING station opens,a switch is released to initiate an alarm. The SPECIFICATIONS retainer used in Model BRG is a glass rod. When oper- ated,the cover hangs down (and cannot be made to stay Manual Fire Alarm Stations shall be non-code, non-break- in a closed position)indicating that the station was used to glass type, equipment with a key operated reset, and so turn in the alarm. OPERATED STATIONS CAN BE SEEN designed that after actual Emergency Operation,they can- UP TO 100 FEETAWAY. Resetting is easily accomplished not be restored to normal except by use of a key. An op- using a reset key. erated station shall be designed such that upon activation, This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications ISO-9001 or anticipate all requirements. All specifications are subject to change without notice. Engineering and Manufacturing For more information,contact NOTIFIER. Phone:(203)484-7161 FAX:(203)484-7118 Quality System Certified to RM §N OTI FI E W 12 Clintonville Road, Northford,Connecticut 06472 International Standard ISO-9001 Made in the U.S.A. DN-65 — Page 1 of 2 BNG(pictured below)uses a tension spring as a retainer. BRG looks the same,except the retainer is a glass rod. 7/8"(2.22) 11/32"(0.34) 1 1-1 (147).47) �--�� 1u r — t,►�TTP The DABC-SP J 4 3/4" �pi1t 1. i (12.06) 1-3/8" (3.4�9) PHYSICAL DIMENSIONS Length: 7.000 inches (17.64 cm) Overall dimensions of semi-flush mounted station: Width: 3.500 inches (8.82 cm) 3-1/4"(8.255 cm)wide x 4-3/4"(12.065 cm)high x 7/8"(2.222 cm)deep. Depth: 1.250 inches (3.15 cm) DABC-SP BACK PLATE 5/8"(1.59) 1-3/8" Length: 9.650 inches (24.318 cm) 3-1/4" �(3.49) Width: 6.750 inches (17.01 cm) (8.25) JALE PtX« PRODUCT LINE INFORMATION Model No. Description 4„ NG-I* Aluminum pull station with red lettering. (10.16) _ ' BNG-1TSL Standard"LOCAL"style BNG-1 (aluminum) 3-1/4" FUEGp unit with terminal strip. (8.25) BNG-1TSRL Standard"LOCAL"style BNG-1 R(red)unit with terminal strip. ® aTtw�K,. BNG-1SP* Spanish aluminum pull station with red FUEGO (FIRE) and JALE (PULL) letters. BG-2 Backbox The BNG-1SP UL listed (contact factory for current status of other listings and approvals). it will be visually detectable at a minimum distance of one BNG-lR** Red aluminum pull station with silver let- hundred feet, front or side. Manual stations shall be con- tering. structed of die-formed aluminum,with operating directions BNG-1RC*** Red aluminum pull station with silver En- provided on the front cover in raised letters. Stations shall glish/French lettering — ULC listed. be suitable for surface mounting on a standard single-gang BNG-1 F** Aluminum pull station with red lettering and box or switch plate, and shall be installed 48" above the DPDT switch. finished floor per ADA requirements. Manual stations shall be Underwriters Laboratories listed. BNG-ITS* Aluminum pull station with red lettering and The DABC Double-Action Cover and DABC-SP adapter pro- two-position, double-row terminal block. vide a simple and economical means to convert NOTIFIER BNG-1 FTS* Aluminum pull station with red lettering with single-action BNG-1 Manual Fire Alarm Stations into DPDT switch and two-position,double-row double-action units. terminal block. The purpose of these adapters is to deter false alarms BRG-1** Aluminum pull station with red lettering and caused by passersby who pull a station and continue on break-glass option. without stopping. Using the double-action adapter requires BRG-1R** Same as BRG-1, but painted red. a person to stop and perform two distinct actions: lifting the cover and pulling the breakstation. Such action is suf- BG-2 Surface-mounting backbox for BNG/BRG ficient to deter potential pranksters from initiating costly Series stations. One end tapped for 1/2" alarms. conduit. The DABC-SP consists of a red and white BSA approved 146-0601 Replacement glass retainer for BRG. back plate and the cover assembly which fits over the BNG- DABC Second action cover for BNG. 1. The cover is hinged to a bracket with nylon bushings DABC-SP NYC back plate with second action cover. which form the cover housing. The DABC-SP back plate and cover housing are punched and drilled to accommo- date field wiring and the mounting screws that secure the MEA 38-93-E BNG-1 and adapter to a wall backbox. ** BSA 750-76-SA *** ULC CS119 Page 2 of 2 — DN-65 April 2, 1998 1-304 (ONOTIFIE R® HD-boo A Pittway Company Heat Detectors Section: Conventional Initiating Devices GENERAL California State Fire The HD-600 Heat Detector is attractive, durable, and fea- Marshal tures combination rate-of-rise and fixed-temperature de- �L 99 7270-0028:170 tectors. Heat detectors are available in 135°F(57°C)and S747 ML361 200°F (94°C)temperature ratings. M EA (except HD622) Rate-of-rise elements detect heat by quickly responding to 250-94-E rapid temperature increase. HD-600 detectors use the F M ON3A8.AY(HD621,HD601,HD602) same reliable pneumatic rate-of-rise element used in former OF4A3.AY(HD603, HD604) models, but offer added aesthetic appeal. The pneumatic OF4A3.AY(HD622, HD623) rate-of-rise element responds to a rapid rise in tempera- OF4A3.AY(HD624) ture, approximately 15°F (8°C) per minute, by expansion of air within the sealed chamber faster than it can escape through a calibrated vent. The resultant increase in pres- sure depresses the diaphragm,causing the electrical con- tact to close the circuit. HD-600 rate-of-rise units have a wide spacing allowance of 50-foot (15.24-meter) centers. See Specifications table (page 2)for details. - Fixed-temperature elements react to heat by responding to a specific temperature setting. The fixed-temperature element uses a fusible alloy. When activated,the external heat collector drops away to provide quick visual confirma- tion that the element has operated. The units protrude only 1-3/8" (34.925 mm)from the ceil- ing surface with a junction box mounting. They have pleas- ing contours and an all-white finish that conforms to ceiling aesthetics. FEATURES n n • Rate-of-rise and fixed-temperature. • One-or two-circuit, normally open. 4-9/16" 2 1/8 • Easy installation. 1-3/8" • Low-profile design. 3-1/4"OR 4"OUTLET BOX Visual indication. �OR 4"SQUARE BOX Cut for HD-600 • surface MOUNTING • Operation testing. mounting. 4REERSIBLE INSTALLATION UNTING Each detector includes a patented reversible mountingLATE plate. In one position, it easily attaches to a 3-1/4" (82.55mm)octagonal box or 4" (101.60 mm)junction box. In reverse,the plate can be used for open wiring without a junction box. A 1/4" (6.35 mm) space between detector32" 8-32" und head �N,flat head and mounting surface allows for wire connections. AllcREWsmounting screws are concealed. C to 1" WOOD SCREWS The detector attaches simply to the mounting plate with a push and twist motion. No special tools are required. 0 The mounting plate is molded of white self-extinguishing thermoplastic rated at 105°C. The plate is extremely strong, JUNCTION BOX CEILING SURFACE yet adapts to uneven mounting surfaces. MOUNTING MOUNTING This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or ISO-9001 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information,contact NOTIFIER. Phone:(203)484-7161 FAX:(203)484-7118 Quality System Certified to ^ IN OTI Fill E R• International Standard ISO-9001 12 Clintonville Road,Northford,Connecticut 06472 Made in the U.S.A. DN-5075 — Page 1 of 2 HD-600 SERIES TESTING METHODS • Models HD-601/HD-621 and HD-602/HD-622 can be tested by the application of quick heat from any convenient source. A portable hair dryer is recommended. However, do not apply heat that exceeds the fixed-temperature rating of the detector. • Models HD-603/HD-623 and'HD-604/HD-624 cannot be tested. However, the fusible alloy element is generally con- sidered so reliable that testing is not necessary. SPECIFICATIONS HD-601 & HD-621 HD-602 & HD-622 HD-603 & HD-623 HD-604 & HD-624 No marking. 0 Gray ring. O Gray spot. O Black dot on white. O Model HD-601 (one circuit) Model HD-602(one circuit) Model HD-603(one circuit) Model"0-604(one circuit) Model HD-621 (dual circuit) Model HD-622(dual circuit) Model HD-623(dual circuit) Model HD-624(dual circuit) Rate-of-rise and Rate-of-rise and Fixed-temperature only Fixed-temperature only fixed-temperature fixed-temperature 135°F(57°C). 200°F(94°C). 135°F(57°C). 200°F(94°C). Application: normal Application: normal Application: unusually violent Application: unusually violent temperature fluctuations and temperature fluctuations and temperature fluctuations and temperature fluctuations and ceiling temperatures not ceiling temperatures ceiling temperatures not ceiling temperatures exceeding 100°F(38°C). exceeding 1007(38°C)but exceeding 100°F (38°C). exceeding 100°F(38°C)but not 150°F (66°C). not 150°F (66°C). Maximum spacing allowance' Maximum spacing allowance' Maximum spacing allowance" Maximum spacing allowance" UL: 50 ft.x 50 ft. UL: 50 ft.x 50 ft. UL: 25 ft.x 25 ft. UL&FM: 15 ft.x 15 ft. (15.24 x 15.24 meters). (15.24 x 15.24 meters). (7.62 x 7.62 meters). (4.572 x 4.572 meters). FM: 30 ft.x 30 ft. FM: 30 ft.x 30 ft. FM: 20 ft.x 20 ft. (9.144 x 9.144 meters). (9.144 x 9.144 meters). (6.096 x 6.096 meters). 'Refer to NFPA for application requirements. SCREW TERMINALS NOTES Application: Heat detectors should be Standard Dual-Circuit used for property protection. Reliance Single-Circuit Detector should not be placed solely on heat de- Detector tectors for life safety. When life safety is Used to send two involved,smoke detectors MUST also be independent signals. used. Detectors must NOT be painted. Wire from alarm panel Battery backup: Heat detectors should be electronically supervised with battery or previous Wire connected to Y ervised P detector. next detector or backup at the panel. \� end-of-line resistor. Rate-of-rise mechanism: The rate-of- rise mechanism may be subject to re- duced sensitivity over time. Annual test- • • ing of the rate-of-rise operation is recom- mended. Wire from ELECTRICAL RATINGS �O alarm panel O 6-125 Volts AC, 3.0 Amp. or previous • 6-28 Volts DC, 1.0 Amp. detector. • 125 Volts DC, 0.3 Amp. • • • 250 Volts DC, 0.1 Amp. Wire connected to Wire connected to next detector or next detector or end-of-line resistor. end-of-line resistor. NOTE: All single-circuit NOTE: All dual-circuit models come with one (1) models come with two(2) normally open dry contact. normally open dry contacts. Page 2 of 2 — DN-5075