BLD2013-00844 Final Garage - BLD Permit / Conditions - 5/30/2014
Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2013-00844 OWNER: THOMAS HAMILTON RECEIVED: 9/19/2013 CONTRACTOR: TOWN & COUNTRY POST FRAME BLDS 425-743-1555 LICENSE: TOWNCPF099LT EXP: 6, ISSUED: 10/15/2013 SITE ADDRESS: 7102 E GRAPEVIEW LOOP RD ALLYN EXPIRES: 4/15/2014 PARCEL NUMBER: 122291400000 LEGAL DESCRIPTION: GOVT LOT 3 &GOVT LOT 4 &TR 5 OF GOVT LOT 5 &TAX 411-B PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW GARAGE -30-ft x 24-ft post frame bldg HWY 3, RIGHT ON GRAPEVIEW LP RD, CONTINUE TO ADDRESS General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 3 No. of Stories: 1 Occ. Load: Building:720 Valuation: $ 30,283.20 Building Height: 14 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 890.0 Ft. Shoreline: Ft. Water Body: CASE INLET Rear: N 205.0 Ft. Slope: Ft. SEPA?: NO Model: Width: Ft. Shoreline Desig.: Side 1: E 405.0 Ft. Year: Serial No.: Side 2: W 270.0 Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee JWH 9/19/2013 $293.70 S120130000000i Planning Review Fee JWH 9/19/2013 $205.00 S1201300000001 EH Plan Review ALP 9/19/2013 $ 103.00 S720130000000i Building State Fee DLC 10/7/2013 $4.50 S120130000000( Building Permit Fee DLC 10/7/2013 $451.85 S120130000000i Total $ 1,058.05 BLD2013-00844 Please refer to the following pages for conditions of this permit. Page 1 of 5 I CASE NOTES FOR BLD2013-00844 CONDITIONS FOR BLD2013-00844 1) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No fou drains within 30ft, down gradient of drainfield/reserve area. X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-64J. 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X .. 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building DepartmenM any further inspections being performed or approvals granted. X 4) Owner/Agent isponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approocuments will result in failure of required building inspections. X 6) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be ap a for, reviewed and approved prior to the change. X L 7) THE FOUNDATMSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X BLD2013-00844 Please refer to the following pages for conditions of this permit. Page 2 of 5 8) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building artment prior to any further inspections being performed or approvals granted. 9) WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Xt T 10) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X 11) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor kno wledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X r 12) This structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes a on County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X 13) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and sblalbe collected by the Building Department prior to any further inspections being performed or approvals granted. X he 14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. , -X BLD2013-00844 Please refer to the following pages for conditions of this permit. Page 3 of 5 15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. 16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or rig ration, must be reviewed and approved by Mason County prior to construction. &X 17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be m�tleprior to requesting additional inspections. X � 18) All property lines shall be clearly identified at the time of foundation inspection. X � 19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X OFIL 20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (older have prevented action from being taken. No more than one extension may be granted. 21) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 22) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shorelister Program. X /G — 23) All construction and demolition debris must be removed from the site after project completion. Pr isposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 24) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent.waters or properties. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X �' BLD2013-00844 Please refer to the following pages for conditions of this permit. Page 4 of 5 25) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. xJ1 26) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X ��e This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason Count access to th ove described property and structure for review and inspection. OWNER OR AGENT: ` DATE: Z —/�` �� BLD2013-00844 Please refer to the following pages for conditions of this permit. Page 5 of 5 ao o CONCRETE MECHANICAL MANUFACTURED HOME D No Date B y .._.. w Footings!Setbacks Gas Piping Ribbons r o Interior Date By interior-Dane By Date By00 O Exterior Date By Exterior-Date Set By _ y Z Point Load I Isolated Footings INSULATION Date By BG!SLAB INSULATION Z Date By Data By FIRE DEPARTMENT 0 Foundation Walls Floors Date By D Date By Data By DECKS C/) FRAMING walls Date By Date I ,K . 9 By Data By PROPANE TANKS PLUMBING Vault Da19 By Date By OTHER Groundwork Attic Date By Date By Type. Date By O.w.)f DRYWALL Type_ Int Brace Wall Date By W Date By Date By r m FINAL INSPECTION v y water Line Fire Separation IV m Date By Dale By Date s Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments 00 o 10025 46 o l AN N — � CD J7rYi7 �s at►-t f/1 ,�/� C- � 0 /t0 /-Y V' r- C0Affk(/�V2 C>^ if, :, 7 . s will G/rN.t OA'( L 0s.e- 50"U -�/dam" (,t ✓"dw, -ec) jo.—)s (/f (D 3 tr��G /''I iw� j%H.� 27� l'� N L3 I H j� jUrrt �.,;,,.� W!'t�•'� d'�"t�'[,r,2 0` f I'A& v 0 o W S Ex. SIt�D -�o PCia�,oGEbcv ��S SAP M M FX, �4C.f�c�s ac r -� � rl r � l Town punt��,�° 16521 Highway 99.Suite C•Lynnwood,WA 98037-3161 P ase Check After Doing'9Ite Plan: B Septic and drainfleid of�f ze Draw North Arrow in Circle POST FRAME BUILDINGS7— Everen:(a25)z5e 4171 • Puyallup:(253)840-9552 roperty dimensions O ewer lines Lr]EleVgtion of property ° Admihlstrative Headquarters: (425)743.1555 xlsting buildings6etbacks of proposed&existing buildings ❑Bodies of water ■ FAX: (425)742-4378 •600.824-9552 p g fly a1n road with name aroma Contractor'sUc.#:TOWNCPF099LT Pro osedbuildin Ioorplan ermabllt.com'•facebook.corr✓permablit 0 Easements Access to proposed building YO Slopes&Contours(5'Increments) Quality:Our Future Depends r7r,It.'" p p p0 g Job Name: Job Site Address: Tax Account#: —I (1— i—Iw O O n O,r� Legal Description: r �_ T RECEIVED SEP 19 2013 426 W. CEDAR S-T , APPROVED 5 T MASON COUNTY DCD PLAN NCB ate:• �� - R„ t; i�,., SITE PLAN REQUIRED TO BE ON TE ' h CHANGES SUBJECT TO APPRO AL BY VIA V Date a ALL SETBACKS ARE MEASURED FROM THE FURTHEST PROJECTION OF THE BUILDING �° Shop V76 Si ` AzAr u �'y i n' � -•testa, Q �aorosE-D zy x3o xO� �`ti kA&-FI R6P1.A�rNC r � G u�oo�sn t D �s J 4 CAR.P0 fIi-`17 . I KtKtz'K t 5V T fACK 'Tt, EXI�TI KC i sNa? is � To ftD V RvN7104 Ng?'o 1MF'5;e✓roc-J S ; / 1 5#OP 7zo;e I i_APUAREo F ' X tkl 0 ,� tt to 0 NOT SIGN INCOMPLETE SITE PLANI -ro', .\)IrLW istomer has verified and approv a location of the building,orientation of the building to the North,and verifies that all Grid White-Customer Copy Plain White-Office Copy ilities are shown on this drawing in correctTation. JSTOMER SIGNATURE LEAD# , 1 0 2012 Perma-MIND Industries FR-34 07/12_ I I�IIII IIIII IIII IIII 1 0 - •OV "„ww"4d ss�e� m -rb'",`'99 it* -*U77,614 fi 407 r -YI70W AL&VIO d �„is ,OF,is /Y v'e 9f 'bog 1 • h� IT 000 W • �„1 w srv1�/1lOdI 7iv,�7 �b'yOvno� .. q r k • t r .PA1070 .�� ms•s d101r ..,,,.w„s,,,,,,icyw,OwM�,�i7H;1u,,,,,,nrH.,,C,.....,-...kr..�.......rr.rurr�.r...w.o.r�+r++-----•-- - ._....,.r.M;V,Y J���,y,,,f�..,,....... .++........- '1 • t7►�li'S-+S'� 000g70 Ala�+►J41% La Aft � ptr,rr•1, �� Na✓1�� 0• . db/ W N/y Ar6forrytWir . yh&Vd0"e(a 1 Masm Cou*Map Output Page Mason County Map is twip� mo tua t t. Et �K a �.- DISCLAIMER AND LIMITATION OF LIABILITY: The data used to make this map have been tested for accuracy,and every e9brt has been made to ensure that these data are timely,accurate and reliable.However, Mason County makes no LEGEND guarantee or warranty to its accuracy as to labeling,dimensions,or placement or location of any map katures contained herein. The boundaries depicted by these data are approximate, Roads Fodmf Lends and are not necessarily accurate to surveying or engineering standards,and are intended for informational purposes only. Mason County does not assume any legal liability or /S'/I#Igt aye, City at$heltkn responsibility arising from the use of this map in a manner not intended by Mason County. �M P vor$& lresms (f] c ty ly 0)") In no event shall Mason County be liable for direct,indirect,incidental,consequential, special, or tort damages of any kind, including,but not limited to, loss of anticipated profits Pafls CcrrnmisSars6r lffCts or benefits arising from use of or reliance on the information contained herein Sectons takes. (0 2009-Mason County GIS Townships Puget Sound&Major Lekos IW100 W. Public Works Dr vqgW Shelton, W A 98584 ELEVLITIotiI W r_7-r7 �5 t'nt V EWTZ) l fib- f NCW 0 60 z3��O MASON COUNTY PERMIT NO. MIQIII— 0&tLlf { DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL _ WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext.352 185 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 BUILDING PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFO/R�MATION: NAME: /.�fD�fr¢5 9hf[-7-c/U' NAME: �o�vy Nat rSrf.�s1 S �Ci T MAILING ADDRESS:f'OBcx //Q MAILING ADDRESS:�� -- She CITY: />t STATE:_Zv,4 ZIP: ' Zy CITY:LYiv1c;w,%!p STATE: iA.f— ZIP: W03 "7 PHONE: 3��C2 _ Z 75--d3f ELL: PHONE: CELL: EMAIL: EMAI n ,1k L&IPARCEL INFORMATION: INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) /ZZ09-/V-OOpOd FIRE DISTRICT LEGAL DESCRIPTION(ABREVIATED): - 4 12.4 4 9 -2- SITE ADDRESS 7/DZ C: CITY DIRECTIONS TO SITE ADDRESS IS PROPERTY WITHIN 200 FT: SALTWATER R LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO J, TYPE OF JOB: NEW [3 ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) ' G— 110'-zll—leTY IS USE: PRIMARY❑ SEASONAL❑, NUMBE9 OF BEDROOMS NUMBER OF BATHROOMS DESCRIBE WORK,aoPoSD�yX.3o"/-�SiQP✓T�ET�Gy�D /°ns�r� ,a��sP SOUARE FOOTAGE: 1 ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE 7ZZO sq.ft. ATTACHED❑ DETACHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED ❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTIO . INACTIVIDr OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. x Signature of Ap licant Date x i i OWNER REPRESENTATIVE/CONTRACTO J Print Name ICATE) BUILDING DEPARTMENT I PLANNING DEPARTMENT FIRE MARSHAL �3 Di a �1�3 &LPeg0A23 -0o9y Name wN /',oa T ,L Parcel#1ZZZ�—1�dDDo BL {—EIZ Mason County --- Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: httpHwww.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIALBELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) ✓ The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described perty for revie and inspection as may be required. Xt Own Agent/ ontractor(circle one)Date: j Page 2 of 2 4 . Name;L,,v F 6oa wr1ey<e7 Parcel# 1ZZ 1`j/f/-0W0e9 BLD# 17b T�lor�rs r/�'Nie-To•,.i Mason County P'q/4� EpT//V Department of Community Development �� �B//Ty Small Parcel Stormwater Management Application/Worksheet (page L Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please`Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings p X Z' _ X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = —Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described pr for review and inspection as may be required. X _ &deOwn /Agent/ ntractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 r Hamilton Small Project SWPPP Narrative and Site Plan 7102 E. Grapeview Loop Road Allyn, WA 98524 Minimum Requirement#2 for small projects as defined the Department of Ecology criteria for stormwater pollution prevention plan Project File Number: Parcel: 12229-14-00000 Narrative: Proposed 24'x 30' post and frame garage/shop (720 sq. ft.)Access provided by an existing gravel driveway. Proposed gutters to downspouts, to splash blocks. This project qualifies as a small project because: This project disturbs less than 1 acre and is not part of a comment plat development. This project will not create, add or replace more than 2,000 square feet of impervious surface. This project will move less than 100 cu. yds. of material graded on site and less than 500 cu. Yds. Of material under the foundation of a building to be built pursuant to an approved building permit. This project will cause less than 7,000 sq. ft. of land disturbing activity. This project is not located within a floodplain or shoreline designation. This project will not adversely impact a wetland, stream or water of the state, or change a natural drainage course. This project does not require engineering to comply. i I I Page 1 J t Element 1—Preserve vegetation/mark clearing limits The area to be cleared and graded shall be marked prior to clearing with visible flagging to preserve vegetation and to clearly show clearing limits. Only the areas marked on the SWPPP site plan to be cleared. Vehicles will only be allowed in the areas to be graded. Element 2—Construction Access BMP C105-There is an existing stabilized construction entrance that is a minimum of 12' onto site. Element 3—Control Flow Rates Does not apply as there will be no substantial grading of site. Post holes only for building. Element 4—Sediment Control Sediment control will be controlled on-site by placement of BMP C233 Silt Fence Element 5—Stabilize Soils Soils will not be stockpiled during the building stage of 2-3 weeks. No soils shall be exposed for more than 24 hours. Element 6—Protect Slopes Does not apply. No cut slope over 4 feet high will exceed 2 feet horizontal to 1 foot vertical, and no fill slopes over feet high will exceed 3 feet horizontal to 1 foot vertical. No engineered slope protection. Element 7—Protect permanent drain inlets There are no storm drain catch basin on site for which will install a temporary protection device, per storm drain inlet protection BMP C220 detail. Element 8—Stabilize channels and outlets Construction will occur during the dry weather. No storm drainage channels or ditches shall be constructed either temporary or permanent. Element 9—Control Pollutants Any and all pollutants, chemicals, liquid products and other materials that have the potential to pose a threat to human health or the environment will be covered, contained and protected from vandalism. All such products will be kept in a locked job site trailer. Element 10—Control De-watering No de-watering of the site is anticipated Element 11—Maintain best management practices Best management practices or BMPs will be inspected and maintained during construction and removed within 30 after the County Inspector or Engineer determines that the site is stabilized provided that they may be removed when they are no longer needed. Element 12- Manage the project This SWPPP will be implemented at all times. The erosion control BMPs will be implemented in the following sequences: 1. Mark clearing limits 2. Install stabilized construction entrance 3. Install protection for existing drainage systems and permanent drain inlets 4. Establish staging areas for storage and handling polluted materials and BMPs 5. Install sediment control BMPs 6. Grade and install stabilization measures for disturbed areas 7. Maintain BMPs until final site stabilization, at which time they may be removed Steve Triplett Permit Coordinator Town & Country Post Frame Buildings ® 16521 Highway 99,Suite C•Lynnwood,WA 98037-3161 Town & COuntry_ Everett:(425)258-4171 •Puyallup:(253)840-9552 POST FRAME BUILDINGS Administrative Headquarters: (425)743-1555 ® FAX: (425)742-4378.800-824-9552 Contractor's Lic.#:TOWNCPF099LT - DIVISIONOF permabilt.com•facebook.com/permabilt Quality: Our Future Depen&On It.' DIRECTIONS TO SITE JOB NAME: !!to MAS AA M I LT QbJ 1 SHIP TO ADDRESS: I��. E. GRAP>�� Lo RY ALLYN , WA -- 21 TELEPHONE#AT JOB DROP: 3�60- 27S Jd!k33 THOMAS GUIDE �" V Can a semi' turn around at the job drop? ❑Yes l(No ❑Back-in Only ❑Other Can a two tone get into the job drop? /Yes ❑No ❑Other Can a concrete truck get into the drop? N(Yes ❑No ❑Other Will a 4 wheel drive vehicle be required for deliveries? ❑Yes /No ❑Other Directions DIRECTION S(Z3 -rN Rou C fA A WI N ( Koss A P I"6 E �R � no nAY) . GO l �R SOALL * E C)Vtg SnLTW#� -r-go Tf\k FTPF F I Ks-c �.��� © TQ MSPHAL 1 'DR�\A wAy ER � ^ aPER (20 A06S) • W ) LL NE ErD f RvM c�J � -To -r RE a PT 'Truck Dimensions:65'long, 8'wide, 121/2'high,and it weighs 35,000 lbs.empty. PtY• 2Truck Dimensions:30'long,8'wide, 121/2'high, and it weighs 18,000 lbs.empty. ©2012 Perma-Bill®Industries FR-35 07/12 I IIIIII IIIII'III I'II li� * 10;4 a7-3fnff 4 V1 S2 1 4