Loading...
HomeMy WebLinkAboutBLD2015-000384 Final SFR - BLD Permit / Conditions - 1/8/2016 Inspection Line (360)427-7262 "60 co' MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 1854 RESIDENTIAL BUILDING PERMIT BLD2015-00384 OWNER: JOHN MCNEIL RECEIVED: 5/20/2015 CONTRACTOR: LICENSE: EXP: ISSUED: 6/16/2015 SITE ADDRESS: 7320 E GRAPEVIEW LOOP RD ALLYN EXPIRES: 12/16/2015 PARCEL NUMBER: 122291300090 LEGAL DESCRIPTION: TR 9 OF GOVT LOT 2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR ST RT 3, R ON GRAPEVIEW LOOP RD, ALLYN END, TO SITE ADDRESS ON THE LEFT SIDE General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3, U Lot Size: Deck: 0 Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:2,137 Garage-Attached 427 Valuation: $ 261,980.64 Building Height: Occ. Status: Basement: cov deck 279 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: W 46.0 Ft. Shoreline: Ft. Water Body: CASE INLET Rear: E Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 5.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 3 Furnace<100K 1 Plan Check Fee GMM 5/20/2015 $ 1,235.62 S1201500000001 Lavatories 3 Heat Pump 1 EH Plan Review GMM 5/20/2015 $205.00 S1201500000001 Bath Tubs 1 Ventilation Fan 4 Planning Review Fee GMM 5/20/2015 $205.00 S1201500000001 Showers 3 Exhaust Hood 1 Building State Fee RTB 6/16/2015 $4.50 S1201500000001 Water Heaters 1 Dryer Vent 1 Building Permit Fee RTB 6/16/2015 $ 1,900.95 S1201500000001 Clothes Washer 1 Mechanical Permit Fee RTB 6/16/2015 $94.70 S1201500000001 Kitchen Sink 2 Mechanical Base Fee RTB 6/16/2015 $28.50 S1201500000001 Dishwasher 1 Plumbing Permit Fee RTB 6/16/2015 $ 136.70 S1201500000001 Hosebibs 2 Plumbing Base Fee RTB 6/16/2015 $24.70 S1201500000001 Total $3,835.67 BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 1 of 6 CASE NOTES FOR BLD2015-00384 CONDITIONS FOR BLD2015-00384 1 Ow er must show proof of satisfactorywater sample prior tot te mporary/permanent occupancy of the residence. X 2) Approved per dimensions and setbacks on submitted site plan. Setbacks that are set forth in SP12014-00044 are measured from the furthest projection of the tructure. X 3) The proposed project must be consist t with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program.X 4) All construction and demolition debris must be removed from the site after project completion. r er disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X0, 5) Temporary erosion control measures must be implemented to prevent water quality degradation of adj�nt waters or properties. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X /1 6) Co rete leachate and wash water must be contained during construction pouring, such that water quality degradation of adjacent waters does not occur. X 7) All property lines shall be clearly identified at the time of foundation inspection. X 8) All surface water and potential runoff from the proposed development will be controlled on site in drywells and infiltration trenches, and shall not adversely affect any adjacent properties, cause sediment deposits, nor increase the velocity flow entering or abutting to any state or co my culvert or ditch system or road way. 9) Lan ngs and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "A t_o ved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 2 of 6 10) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure the structures meet the setback conditions listed. X 11) Retaining walls needed to support a su harge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 12) All other necessary permits from Mason County, Washington State and/or Federal Agencies th are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X '�, 13) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. Ther are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1.. -647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 14) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not Pe granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building De68rtment prior to any further inspections being performed or approvals granted. X 15) Ow r/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 16) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Offici I. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or remyalof approved documents will result in failure of required building inspections. X 17) The "approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Builq'nb Department prior to any further inspections being performed or approvals granted. X i 18) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In ad tion the following credits from R406.2 shall be completed as follows: 3b H.P. min. HSPF 8.5, 5a elec.W.H. min. EF 0.93 = 1.5 X BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 3 of 6 19) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in %or%sheets. The Ma n County Permit Center will also have some available. X 20) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R40 .1. X 21) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For ore information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X 22) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other ve al concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 23) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), rep rjs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 4 of 6 24) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be • ch ged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Xf, 25) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State f Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in per 'revocation. X 26) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your proj ftt/- X 27) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordA nce or regulation, must be reviewed and approved by Mason County prior to construction. X 28) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Insp for shall be made prior to requesting additional inspections. X 1�6 29) All property lines shall be clearly identified at the time of foundation inspection. X 30) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Masofl County ordinances and building regulations. X 'n,M 31) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for actin for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hol r have prevented action from being taken. No more than one extension may be granted. X t BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 5 of 6 32) Pre sure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, co ectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. ' X OWNER / BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PER IT (CATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. 61(G140 Si ature �(� Date -JeAr�/`� �27VY�-ee OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2015-00384 Please refer to the following pages for conditions of this permit. Page 6 of 6 a CONCRETE MECHANICAL MANUFACTURED HOME 0 o v, Footings 1 Setbacks Date By Ribbons m Gas Piping o Inter►or Data By Inlerior-Data By Date By r o Exterior Date jp• By Exterior Date E3 O Y m Set-up Load!Isolated Footings INSULATION pate By 2 BG!SLAB INSULATION w Z Data ._. y Data By FIRE DEPARTMENT Foundation Wails Floors Date By Date . 1'2,1 B [fate By DECKS FRAMING Walls Date; By r. tp By Data By PROPANE TANKS PLUMBING vault Date ley Dato By «...,.. OTHER Groundwork Attic Dale By Date Ely Type- Date By D.w.v DRYWALL Type_ Int.Brace Wall Date By W �,� By Dace By r 0 FINAL INSPECTION 0 N Water Line Fire Seperation C m eo EAE, By Date+ By Date/ —z 3 —�J (S B Q g Pass or Request Inspect. c Type of Insp. Fail Date Date Ilene By Comments -- - C4 00 o _ .I lri '✓� A S. y 5✓ -7 31 CV) I co o 116 Cn 0 y �+ G'CG �j r• c�• 1 �� i Zt 5 y (' L �y ✓1 3 h •' L.r.r• L( CD Q�r-.1 �` �i►eats Q Jae s V CA, t-,o/,IJS � SITt v CD 0 Permit# MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location -7300 6 6!2��LAzL-) big- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been nd: Items listed below must be corrected to gain compliance 714)00 44 LIAMIV i,d-r to vi e- -re(-r -tA rs T n t ed c.t _n_.P 9d� ykt -rkb -eH-f )I /r— T 4 Cep I v44 1.a r+ rdl Zti 4 el S n 1%YJ at J I ,n n► e yv► ,'�1 I.,f► c,tocA You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Please contact our office 0 Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" This is not a complete inspection(���tir� disasters.This is NOTa Date 9,11 f l �� Department n L CORRECTION NOrICAL Inspector *�- N, N* VT , r - A* ' THUmb, T`-oqu Permit# �� y MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location �3 �� G r t- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance / 0-C eL V ¢ 4" o^ Ct �► C e S S You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office ,,,d,make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑ This is not a complete inspection disasters.This is NOT a Date S✓ Department 9 �l✓ CORRECTION NOTICE. Inspector RI , 0 NOT , i-�1�,�4 ' ' THImak T,,vnomr 12/31/2015 Conditions Associated With L 10:03:02AM Case #: BLD2015-00384 i� Permit Condition Status Updated item# Code Title Status Changed By Tag Date By 1) 3005 WATER ADEQUACY NOT MET 6/5/2015 CEW Owner must show proof of satisfactory water sample prior to temporary/permanent occupancy of the residence. X 2) 200 SITE PLAN NOT MET 6/5/2015 AHB Approved per dimensions and setbacks on submitted site plan. Setbacks that are set forth in SPI2014-00044 are measured from the furthest projection of the structure. X 3) 1000 NEW DECK CONDITION NOT MET 12/31/2015 AHB The applicant acknowledges that this additional deck to the east of the new residence is allowed but cover or roof oV deck i not al we to location in the building setback. X 4) 70 Shoreline Management Act NOT MET 6/5/2015 AHB The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act,its rules,and the Mason County Shoreline Master Program.X 5) 100 Construction Debris Removal NOT MET 6/5/2015 AHB All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 6) 170 Temporary Erosion Control NOT MET 6/5/2015 AHB Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or properties. Silt fencing,straw,or surface matting must be installed and maintained until upland vegetation has become established. X 7) 110 Concrete Leachate NOT MET 6/5/2015 AHB Concrete leachate and wash water must be contained during construction pouring,such that water quality degradation of adjacent waters does not occur. X 8) 5510 Property Lines NOT MET 6/5/2015 AHB All property lines shall be clearly identified at the time of foundation inspection. X 9) 1000 SURFACE WATER CONTROL NOT MET 6/5/2015 AHB All surface water and potential runoff from the proposed development will be controlled on site in drywells and infiltration trenches,and shall not adversely affect any adjacent properties,cause sediment deposits,nor increase the velocity flow entering or abutting to any state or county culvert or ditch system or road way. X 10) 6550 LANDINGS AND STAIRS NOT MET 6/5/2015 AHB Landings and stairs must meet the same setback conditions as any permitted structure;and,must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 11) 6500 ACCESSORY STRUCTURE NOT MET 6/5/2015 AHB By definition,propane tanks and heatpumps are structures,which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. Page 1 of 5 CaseConditions..rpt PLANN "iNG SITE PLAN FOR: MAY 2 0 2015 7320 E. GR,APEVIEW LOOP ROAD 426 W. CEDAR ST PLANNING - ALL SETBACKS AR MEASURED I FROM THE FU THEST cco.. ��z —}— �Q PROJECTION OFT E BUILDING aPUMP HOUSE �'r�� , r ' ► . �� N 894722■ 187,76 65.29' R ROOF 19.25' HEAT PUMP 3.670 ► W` �- OVERHANG I 3 L ► �, `\ 1 ROOF OVERHANG 1.5� PROPOSED RESlOf1VCE 4"X4°POST(TYPICAL) TO BUILDING FACE TYP.( r ' 49.8T t� S TY POLE HE 1� (TO BE RELOCATED) 'S,�E 8L YT, ► 50.99' 66.26' 70.3T V r S 894722" w 187.62' PROVED ► I MASON Co LINTY DCD PLANNING j SITE PLA REQUIRED TO BE ON SITE CHANG SU JECT TO AP ROVAL IRESIDENCE BY Date 241 PREPARED FOR. �,McAEa OLand FOR PROPERTY SURVEY DATA REFER TO RECORD OFSURVEY RECORDED UNDER MASON COUNTY AUDITOR'S FILE N0. 2031226. Surveying o . 20 0 20 60 o"6s a�018Tyo �`�� at The Landing in Key Center LLC AL LA Oa 15510 92nd Street KPN Scale 1"= 20 /t0{4 Gig Harbor, WA 98329 P.O. Box 124, Vaughn, WA 9H394-0124 DRAMNC NO.46259 ORANN BY• M(P DATE• 10123114 JJL')f-2�5-12 DANIEL B. JOHNSON, PLS 128408 11 (253) 303-0270 FAX (253) 303-0273 ealul 12z29- i�- ooa9a �► MASON COUNTY PERMIT NOT id2C,60 -36q DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 n i IA r) ILDING PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: M it I --Xy�bVt I NAME: FftyKj[ 1 G(GSS�C PaWt.eS MAILING ADDRESS: MAILING ADD SS: 6d NC- "KC Dr CITY: [—alr\e.)oW STATE: Wc, ZIP: lq 4II CITY. a N STATE: VJ 6k ZIP:CIA$ss PHONE: J CELL: PHONE: - 3$3 CELL: ),S3-S 14--q-Aa L( EMAIL: EMAIL : 'L Cte, .Co VA L&I REG#C C FAM LCN33 3jJ EXP. A /lo/266 PARCEL INFORMATION: �r PARCEL NUMBER(12 DIGIT NUMBER) -1- 13 6a 09 FIRE DISTRICT_ LEGAL DESCRIPTION(ABBREVIATED): ( _! GE c1 S -11 P1. SITE ADDRESS 1310 E Gx c pey a�fw Lg eiy CITY A Il j y\ DIRECTIONS TO SITE ADDRESS IS PROPERTY WITHIN 200 FT: SALTWATER LAKE❑ RIVER/CREEK❑ POND ❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO❑ TYPE OF JOB: NEW t�' ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) IS USE: PRIMARYISL SEASONAL❑ NUMBER OF BEDROOMS_ NUMBER OF BATHROOMS 3 DESCRIBE WORK SQUARE FOOTAGE: I ST FLOOR ^sq.ft. 2ND FLOOR_tl5 7 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK a71 q sq.ft.STORAGE sq.ft. OTHER sq.ft. GARAGE--sq.ft. ATTACHED, DETACHED❑ CARPORT sq.ft. ATTACHED ❑ DETACHED❑ MANUFACTU N: *4 COPIES OF THE FLOOR PLAN M MODEL LENGTH W H BEDROOMS BATHS SERIAL OWNER!BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTIO CTIVI OF THIS PERMIT APPLICATION OF 180 DAYS VYIILL INVALID THE APPLICATION. mu� re of Applicant Date 5 x r,�� OWNER/REPRESENTATIV /C T CTOR Print Name (CIRCLET T DEPARTMENTAL REVIEW APPROVED DATE, DENIED DATE tXOTES/C TI'IONS BUILDING DEPARTMENTAL PLANNING DEPARTMENT 2r . CEP FIRE MARSHAL J Aff*fs Ir We 20, COU�Tr MASON COUNTY PERMIT NO"M2M -tp,7C}4 DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 3 Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext. 352 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext.352 �&BING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: p�\ 'S8wv\, 1 $�I V A4 NAME: 'ra&Ki� (kev% C MAILING ADDRESS: Za V,ok SO4 MAILING ADD SS: 60 NC— Lake 1), CITY: (.a eba STATE:W 4 ZIP:q9,3ga CITY: t4imui c STATE:W r1 ZIP: q05Q PHONE: CELL: PHONE:-5( ,Z4-1-G3�i CELL: X3-514-1 l,�t4 EMAIL: EMAIL : it4c,QFa L&I REG#CC Fh41Az t EXP.a/a0/ dkc PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): �a��l l� ^ 000cf o LEGAL DESCRIPTION(ABBREVIATED): TVC Ci 0 F (p d v: a, 5 (f.- SITE ADDRESS: :�.0 F- G-,&Jge\)wW � YZL CITY:Mkm 'v\. DIRECTIONS TO SITE ADDRESS: TYPE OF JOB NEW ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS—I'FLOOR_2NDFLOOR NK_BASEMENT GARAGE K OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNIYS T_vne of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_ Toilets Type of Unit No.of Units Fees Bathroom Sink 3 Furnace 1 Bath Tubs I Heatpump Showers 7 Spot Vent Fan Water Heater 1 Propane Tank Clothes Washer i Gas Outlets Kitchen Sinks `a Wood/Gas/Pellet Stove Dishwasher I Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the informoo rovided is accurate and grants employees of Mason County access to the above described property and structure(s)for revie iih!*aetion.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days iidon work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INS 'IVXMAI CTIVI�?F THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. (:�` S� x Signature of Applicant Date F x G, ��� 42 � < Owner/Owners Re resentativ Contracto , Print Name (indicate which one DEPARTMENTAL REVIEW APPROVED ATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT 1� PLANNING DEPARTMENT FIRE MARSHAL )W# S Name o G Nei \ Parcel# "I ' —yw"I 0 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per M;.son County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surfaceZ. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = oyj X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X X = Any paved, gravel or packed area per definition above table X Patios/Walks X X = Any paved, gravel or packed area per definition above table X Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described pro rh or review and inspection as may be required. /g X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name C rC Parcel# q'' BLD# Mason County 131 n ' z Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requil��3ltlte: Management in this jurisdiction. A complete copy of the ordinance can be found on thty http//www.co.mason.wa—us/code/commissioners/index.htm MAY 2 0 201' Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". 426 W. CF DA,, Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) z The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/d ra infield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described prope for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 J Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information FAMILY CLASSIC HOMES Indoor Comfort Systems 7320 E GRAPEVIEW LOOP RD 118 violet meadows st s ALLYN,WA. tacoma,wa.98444 Heating System Type: O All other Systems O Heat Pump RECEIVED To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature _ M4Y Z 0 2015 Instructions - Design Temperature Difference(A-0 fhll� 1 a5eattle:Sea Tat AP AT=Indoor(70 degrees)-Outdoor Design Temp 426 W. CEDAR ST Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 2,328 Average Ceiling Height Conditioned Volume t0 Instructions Average Ceiling Height(ft) 9.0 2C,952 Glazing and Doors U-Factor X Area = UA Instructions 0.30 262 78.60 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions R-49 0.026 F17364 35.46 Single Rafter or Joist Vaulted Ceilings }! U-Factor X Area UA Instructions Select R-Value �j No selection Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions -211ntermedata �1 0.056 2.375 133.00 Floors U-Factor X Area UA Instructions 0.029 ® 27.96 I; R-30 "J i Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions Select R—aiue No selection --- Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions No selection — Select conditioning '� - Slab on Grade(see Figure 1) F-Factor X Leh UA , 10 Fully insulated 0.360 R Instructions Location of Ducts Instructions — --- Duct Leakage Coefficient ricondttloned space _ .v.�_. --1 1.10 Sum of UA 275.02 Envelope Heat Load 12,651 Btu/Hour Figure 1 Sumof UAXAT Air Leakage Heat Load 10,409 Btu/Hour Volume X 0.6 X AT X 018 AM-Grade Building Design Heat Load 23,060 Btu!Hour Air Leakage+Envelope Heat Loss Below fYed! Building and Duct Heat Load 25,366 Btu/Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 Duds in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 31,707 Btu/Hour Building and Dud Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) ^fJf * 1f--pZ MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST , Owner's Name. / n - e: I Reviewed By. Documents./ ".Building Permit ApplicationApleted _Lrnwater Chet �/=�Intake Checklist Completed, U I L D I N G ,�plan includes:Allowable building area,roof o gs,decks,etc. �n__ILr c Apparatus Access Road info required? Yes/ o ergy Code Application Form-O Electric wall eater b Electric central furnace O LPG Furnace ®Heat pump with electric furnace O Feat pump with LPG furnace O Boiler(heat type ) O Ductless Heat Pump O Other.Specify: v,' Mechanical/Plumbing Application-WATER TER F17ELPATsqOCATI0N —Engineering? Yes/No Snow load: Se' c: D2 Stock Plan-approved snow load: Seismic: D2GT I 1 C-) Man actor mes-4 S Foundation Type: ANSI/Man ethod Engineered footing/foundatiori Baseme Decks: Covered? Uncovered over 4 x 30"? Construction plans r Construction Plans:_3 COMPLETE SETS � D laps Legible �✓' ecogaized Scale _Eel vation Views VGYoss Section RECEIVED ✓- Foundation Plan J Roof Framing Plan �loor Plan-Use of rooms noted(all floors) or Framing Plan-all floor levels including loft,crawlspace,etc. (<L 00 S.F.??-stairs?) MAY 2 0 2015 PZan—De—tails• eck Framing Plan,incl.cov.porch framing l 1p 6 c' 426 W. CEDAR ST ,� ✓"Yoof framing details,truss lay-out may be needed (Hip and girClocation shown) �1�� 11'le7 Z2 y Wall Framing-Does bearing-wall height exceed i n'9���^���Mmbe required) rY1 1�}X (C+' door framing. Floor joists(size&spacing): �2. (YI Floor beams: �} endow headers. Typical header:__�X I A X IR `Garage header. �undation:footing size,reinforcement n t7_Soncrete Wails-Does Concrete Wall Height Exceed 8'?(Engineering maybe required see details) _�✓/ dings at all exits?Less than 30"above eZ N.. eated By Furnace-Location of Furnace IL. ill's Q Q � LFuel type: Stove Information Shown-Fuel Type? Location(s): endow Sizes Marked on Plans A —W I rld O W � Li:C A-Z raced wall panels(shear walls)marked on plans or lateral en i ? (WJ SF� COMMENTS: ENGINEERING REQUIRED Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the'engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: Snow_psf. IRREGULAR BUILDINGS R301222.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: - 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft beyond the braced wall line. 3)End of BWP extends more than 1 ft_over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces, chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. H:\permit tech building checklis-doc Revised 11-29-2007