HomeMy WebLinkAboutBLD2009-00087 Final SFR - BLD Permit / Conditions - 1/12/2010 Insction Line
36 )427- 262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427(9600,ext7352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT
BLD2009-00087
OWNER: TIMOTHY BOVEY RECEIVED: 2/10/2009
CONTRACTOR: REALITY HOMES INC. 253-926-6330 LICENSE: REALIH1984CN EXP: 2/15/2010 ISSUED: 4/27/2009
SITE ADDRESS: 7490 E GRAPEVIEW LOOP RD ALLYN EXPIRES: 10/27/2009
PARCEL NUMBER: 122295002040
LEGAL DESCRIPTION: ALLYN BEACH TRACTS BLK: 2 TRS: 40 &41 EX
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Residence HWY 3 TO 2ND ENTRANCE TO GRAPEVIEW LOOP ROAD TO ADDRESS
ON LEFT,
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: V-B
Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3, U-1 Lot Size: Deck:
Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,824 Garage-Attached 491
Valuation: Building Height: Occ. Status: Seasonal Basement: cov. deck 144
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: W 38.0 Ft. Shoreline: 52.0 Ft. Water Body: Case Inlet
Model: Width: Ft. Rear: E 52.0 Ft. Slope: Ft. SEPA?: No
li orene es Shoreline Di
Side 1: N 5.0 Ft. 9.: Urban
Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Dishwasher 1 Exhaust Hood 1 Plan Check Fee TW 2/10/2009 $1,006.30 S22009000
Hosebibs 2 Ventilation Fan 4 EH Plan Review TW 2/10/2009 $41.00 S220i)9000
Kitchen Sink 1 Dryer Vent 1 Water Adequacy Plan Review TW 2/10/2009 $41.00 S22009000
Lavatories 3 Planning Review Fee TW 2/10/2009 $205.00 S22009000
Water Closets (Toilets) 3 Address Fee TW 2/11/2009 $173.50 S22009000
Water Heaters 1 Building State Fee RTB 2/12/2009 $4.50 S22009000
Bath Tubs 1 Building Permit Fee RTB 2/12/2009 $1,548.15 S22009000
Clothes Washer 1 Mechanical Permit Fee RTB 2/12/2009 $58.20 522009000
Mechanical Base Fee RTB 2/12/2009 $28.50 S22009000
Plumbing Permit Fee RTB 2/12/2009 $103.14 S22009000
Plumbing Base Fee RTB 2/12/2009 $24.70 S22009000
Total $3,233.99
BLD2009-00087 Please referto the following pages for conditions of this permit. 1 Of 5
CASE NOTES FOR
BLD2009-00087
CONDITIONS FOR
BLD2009-00087
1) Approved per dimensions and setbacks on submitted site plan with replanting in wetland area and 15-foot building setback. Setbacks are measured from
the furthesLprojection of the structure.
X
2) Proposed decks and patios on saltwater side of new residence shall be located in the northeast area, upland of the shoreline setback, and no closer than
10 feet from the edge of the revegetated wetland area.
X •:12�
3) Mason County Utility staff will need to inspect the connection to the grinder from the house before it is covered.
X
4) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are re wired for this proposed development and
construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X /l
5) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X ° j-13
6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X
7) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
8) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
X
9) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X C11
BLD2009-00087 Please referto the following pages for conditions of this permit. 2 of 5
10) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X !:L;
11) Washington State Energy Code Compliance has been approved using the following:
Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors
(Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab
Insulation R-10.
Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the
underside of the roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation.
X
12) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X '�
13) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X �°�Z.,
E�
14) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted.
X
15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X j
BLD2009-00087 Please referto the following pages for conditions of this permit. 3 of 5
16), Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
• stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
informcition regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X �
17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
X t"Z,
18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall bye,made prior to requesting additional inspections.
X 1�
19) All property lines shall be clearly identified at the time of foundation inspection. X i '
20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
XZ,
21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X
22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, and fl hin g. Install metal connectors approved for contact with the new types of pressure treated material.
X_
23) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
X_ `1z
24) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
X_ :�z
BLD2009-00087 Please referto the following pages for conditions of this permit. 4 of 5
1
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWNER OR AGENT: ----, DATE
BLD2009-00087 Please refer to the following pages for conditions of this permit. 5 of 5
o CONCRETE MECHANICAL MANUFACTURED HOME -
0
0 Footings/Setbacks Date By Ribbons M
Gas Piping
o Interior Date By interior-Date By Date B�
o f
0D Exterior Date '7--- Bye` Exterior-Date B -�
Set-up
Point Load I Isolated Footings INSULATION Date By 0
BG f SLAB INSULATION — - -- —I
Date By Data By FIRE DEPARTMENT
Foundation Walls Floors Date By
Date By Data By DECKS
FRAMING walls Date By
Date /Z-- By Data By PROPANE TANKS
PLUMBING vault Date By
Date By OTHER
Groundwork Attic
Date By Type.
Data By Date By
D.W.v DRYWALL Type.
_ r Int Brace Wall Date By ca
Date By �� Date B r
-0y FINAL INSPECTION 0
m Water LineFire Separation N
W 0-11- lDateBy Date By Date / —�� "�� By O
m �
Pass or Request Inspect. c
Type of Insp. Fail Date Date Done By Comments ono
CD
ZA
8 �i
a
0
0 .L r4Oa
to
CD C
.Qt`
0
•
7
T k
6AV
t Of
W Al
i
o
c
t
� ._....... . ._.:., Vim.+
E E APPROWD
MASc,N COUNTY DCD .'l..ANr4lNG
S
t JITE PLA>PEQUIREr r7 PF ON ,ITE
"D Ar '+ JAL
1
date
Q a7
\`' a.® ❑ 0
w �
c 0O ❑ 0d },
sue, o 0 0 0 �
0 0 0 0
0 0 0 0 0
W UUUUU
,� •� cn M M M �` E � � Y
Q V1 N N N cV s i UX
o
cd
� xzxuo
MASON COUNTY PERMIT N0..
BUILDING PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner iItoriay t_ f5 ✓cy Company Name k/n,,4e- 1-.JC
Mailing Address !Zs3C, S�. to;k S-7 Mailing Address i3o,; AL&;<A j2>64 sf,✓e ( s,.4,-rc
City CA ;—,i_6 State dA Zip Code `VO 6 City r r r E State WA Zip Code A F`IZ�
Phone `(dq • 04 71 Other Ph. 42S 7q 3 - q 3;� Phone Z53 `12(-,6v¢ZZ Other Ph.
Lien/Title Holder Contractor Reg.# A64L-1 fa I y€3-FCs1 Exp.
E mail address J � E Mail Address 644i), Dc,Jr/t S /2eA��rrrf.f4ES•c o.K
Drivers Lic.# &,,✓E y r L. L'I°1 C r- DOB I 73 Drivers Lic.# DOB
SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well. X Water System Name of Water System
PARCEL INFORMATION- 12 Digit Parcel No,`j 222 C1<0C) 2_J 1{y Fire District
Legal Description A t,y,J J'AA s qc, r 1
Site Address(Please include street name,street number and'city) 14gC) i,JA
D" tions to site LZ ) c� +�Ai L is A✓ T� ,.a S i i T,f 'r' S
Will timber be cut and sold in parcel preparation?Yes/N.o
Is property within 200'of Saltwater CAS Lake n10 River/Creek r ,9 _Pond nl`�
Wetland ,'10 Seasonal Runoff i.fcv Stream rJc> Slopes or Bluffs > 15%
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No
TYPE OF JOB - New X Add Alt Repair Other_ PRIMARY RESIDENCE ❑ SEASONAL
Use of Building,'/--N M Res, Describe Work
No. of Bedrooms :?> No. of Bathrooms 3 Square Footage- 1 st Floor 1 U 1 2nd Floor 7 -2 2
3rd Floor Basement Deck Covered Deck Other Sq. ft.
Garage 1 Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width Serial No. No.of Bedrooms No. of Bathrooms
Type of Heat Purchase Price$ Replacement Unit? Yes/No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF OF CONTIN ATIOt( WORK IS BY MEANS OF A PROGRESS INSPECTION.
X c ,' Date:
Owner/Owners Re or indicate which one
FOR OFFICIAL USE BEYOND THIS POINT Accepted by:_ Date 1
DEPARTMENTAL REVIEW AP ROVED DENIED NOTES
Building Department -
Planning Department0n
Environmental Health Department
Public Works Department
Fire Marshal
FEES
Building Permit Fee - Site Inspection
Plan Review Fee EH Review Fee
Plumbing & Base Fee 03• 01 a Y 76 Planninq Review Fee
Mechanical & Base fee J-0 Other
Wood/Gas/Pellet Stove Fee State Fee I
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES
_
MASON COUNTY PERMIT NO. "-
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W. Cedar•P.O. Box 186, Shelton, WA 98584
Shelton(360)427-9670•Belfair(360)275-4467•Elma(360)482-5269
On the web www.co_mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner �,vY,c t M f�n v� y Company Name L-I'r l iLM E> ldc_
Maili g Address 115 t Mailin Address ILO O A-E x��t4�E,, ty v� E
City State Zip Code 651 City F& State y�A Zip Code `7F'4 Zq
Phone(AQ6)LIOq-Oh`+1 Other Ph. L`i 2-0-7,7 y.� y Phone 2S `f z6 ' �_e z2 Other Ph.
Lien/Title Holder Contractor Reg. # K 6AL 1 H i q F tC_-yExp z of
Email address -J: 't em, Q f S I C- Corn E Mail Address "'A'). ye..rjj(r c /-�
Drivers Lic.# L.z DOB 1 /61 Drivers Lic.# DOB
SEPTIC INFORMATION - Connect to New Septic Existing Septic- Connect to Sewer System
Name of Sewer System
PARCEL INFORMATION- 12 Digit Parcel No, 7.L1Z� sc. Z.oNw Fire District
Legal Description T%�nc-•S qe Y( , 5-„c P1 iXAe—L-
Site Address(Pleas include street name,street number and city) 6 lgrJO f 'AL v tc�! 'Ce)a u 7e z
Directions to site(E c,( *J,: (,)/,A,) S li r.-i Sr (i-) A7 tf S7 1 TS ,a;.
aC ;E L�r_
Is property vyithin 200'of Saltwater Y&s Lake River/Creek 40 Pond
Wetland ,N(c Seasonal Runoff_6(O'Stream s�Ic Slopes or Bluffs > 15%
TYPE OF JOB - New Add Alt Repair Other Use of Building
Location of Fixtures/Units- 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric—LPG Natural Gas_Heat Pump_
Toilets Type of Unit No.of Units Fees
Bathroom Sink 3 Furnace
Bath Tubs Heatpumps
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer ) Gas Outlets
Kithen Sinks Wood/Gas✓Pellet Stove
Dishwasher Kitchen Exhaust Hood _
Hosebibs Dryer Vent P
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I dedare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION.
X Date:
Owner/Owners Representative/Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by:__ Planning Pd Ck# Date Bid?d_ Receipt No.---
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Occ Group—Type Constr.
Planning Department
Environmental Health Department
FEES
Plumbing & Base Fee Site Inspection
Mechanical & Base fee UFC Plan Review Fee
Wood/Gas/Pellet Stove Fee Other
Violation Fee TOTAL FEES
0 CO& MASON COUNTY Shelton (360) 427-9670
DEPARTMENT OF COMMUNITY DEVELOPMENT
Belfair (360) 275-4467
Planning
Mason County Bldg.1 411 N.5th Elma (360) 482-5269
P.O.Box 279 Shelton,WA 98584
1854
March 4, 2009
Timothy L. Bovey
12536 SE 70"' Street
Newcastle WA 98056
RE: Building Permit BLD2009-00087 on Parcel Number 12229-50-02040
Dear Mr. Bovey
This letter is to bring to your attention an issue that will affect the further review of your
building permit and the location of your proposed residence on the subject property
located along Grapeview Loop Road. Staff made a site inspection for the building permit
was made on Friday February 20, 2009. At that time, staff verified the location of the
proposed residence on the property and noted the presence of surface water and
ground seepage in the footprint of the proposed building.
Staff checked office records on past permitting or reviews done on the subject parcel. A
site pre-inspection was done on this property in May 2002 [SPI2002-00058] that
described certain wetland characteristics on the property at the time of inspection and
that a wetland study be completed prior to further development. A subsequent case
was begun in October 2004 that was in response to filling and grading on the property
done without county review [ENF2004-00424]; this case remains outstanding as the
property owner needed to submit a wetland study and vegetation restoration plan that
addresses the past filling and site corrections. An additional site pre-inspection
SPI2008-00105 was done in June 2008 to state current standards for development on
the property, and no mention of this pending 2004 enforcement case was made by the
property owner at that time.
The current issue is to resolve this enforcement case ENF2004-00424 regarding the
affected wetland or shoreline vegetation buffer as Mason County reviews the proposed
residence under permit number BLD2009-00089. As part of the proposal review, you
need to have a qualified biologist prepare a wetland report that delineates the wetland
edge, characterizes the wetland category, and determines the proper vegetation buffer
using the information from Mason County Resource Ordinance Chapter 17.01.070
Wetlands. Proposed development near the wetlands and shoreline shall have the
vegetative buffer determined by the biologist, and proposed buildings must be set back
an additional 15 feet from the outer edge of that buffer.
The wetland and vegetation buffer currently contain gravel fill but some surface water
and ground seepage is still present. The Wetlands Chapter offers management
standards for restoring and enhancing wetland and buffer areas. Some tree limbs in the
buffer may be trimmed for view improvement on a limited basis in accordance with the
Wetland chapter standards.
Once the biologist assists you in preparing a site plan that includes the wetland and
vegetation buffer areas, you will need to show the locations of your proposed
improvements (buildings, decks or balconies, patios, sewer connection, yard areas) on
that site plan, which will be used for the review of your building permit and for future
permit inspections. You must include that all development must be landward of the
shoreline setback that is the diagonal line crossing the subject property from northeast
to southwest as noted in the findings of SPI2008-00105; the exception to this standard
is decks or patios built at grade within the 15-foot building setback forward of the
shoreline setback.
Specific County Codes standards for future development noted above may be found at
the County website address http://www.co.mason.wa.us. then Codes & Regulations,
and Community Development. If you have any questions please feel free to call me at
(360) 427-9670 extension 365. Thank you.
Sincerely,
Allan Borden
Senior Planner
Site Reviews and Long Range
Enc: SPI2008-00105 findings
Page 1 of 1
r
h_
x"
https://fortress.wa.gov/ecy/shorephotos/yr2000/Mason/010512-160136_lg_wb.jpg 2/24/2009
Page 1 of 1
R
tt `
V
` y5�11C IAY�i ;••
m
https:Hfortress.wa.gov/ecy/shorephotos/yr2006/Mason/060811_11484.jpg 2/24/2009
Case Activity Listing 4 2/24/20099:58:20AM
Case #: ENF2004-00424
i�
Assigned Done -:
Activity Description Date 1 Date 2 Date 3 Hold Disp To & By Update' Updated By
ENFA400 Compliance Due Date 11/18/2004 3/1/2005 None PEND KLF KLF 2/8/2005 KLF
12/27/04-submit Restoration Plan,Restoration Bond and$360 Restoration Plan Review and Tracking Fee as detailed in letter dated 11/18/04 mailed 1st cl/cert.klf.
***Per phone call w/atty,re-set due date to 3/l/04 to provide for consultant retention,development of comprehensive proposal and coordination with County.klf.
***following meeting 1/3/05 with attorney James Tracy(360)779-7889-not yet formally retained-due.date extended to 2/14/05. By that date,submit either Restoration Plan,Bond and$360 or submit
wetland delineation/categorization,ATF MEP application,ATF SMP Variance and associated documents. ***if permit applications are submitted,the fees are tripled due to After the Fact status,w/ 1/3 of
the amt.to pay the standard case fees and 2/3 of the amt.to"after the fact"in this ENF case.klf.
***due date extended to 3/l/05 per phone call with Vaughn of Wiltermood. He has the delineation completed(was not able to dig through fill placed,but referenced adjacent parcels to determine
approximate line. He believes that because of the system's connectivity to Case Inlet,we are looking at a Category I Wetland. He will contact owner and attorney and determine course of action(permit vs
restore).klf.
ENFA010 Complaint Received 10/4/2004 None KLW 10/4/2004 KLW
COMPLAINT RECEIVED AND FORWARDED TO KLF 10/4/04
ENFA911 Miscellaneous Action 10/4/2004 10/4/2004 None KLF 10/4/2004 KLW
ROUTED FOR INSPECTON
ENF13001 Inspection 10/15/2004 10/15/2004 None DONE KLF KLF 12/l/2004 KLF
10/15/04-site inspection and photo documentation(attached in TM). Observed vegetation removal and grading/fill deposition in shoreline buffer/potentially jurisdictional wetland(see SP12002-00058).klf.
Page 1 of 1 CaseActivity..rpt
Page of
s@� t Mtn � •�� f '� P.T %.;l�.,
u
j
• D• 114 1141 14 11'
Page 1 of 1
4
i
_
1
µ
`a b•t, y 4 •. it '"
`h .
yr ,! .,7ki �,.. , .• ', x ti e � 3 '";''` s.$ t #5 ,'t,�".��.�.. p '.:'fit
���`}�..-„�� �.._ ,r�'�'�.�`r E '.�''-` �A ';:. +kwR.x L` Y e .r -"w ! � L, °'"�r�;+ rb �E.��h:' �•.'ir'� �k�
.44
•
.. u./i a A . �;:}�'' 1 •... ss, i a i r �a,.+r. ,�"`t`` `" vS.• K*{T-1 'a• '«.
g
wky'.ly "x -` � eS.` i ��!'1 i � w"' X♦ .. 4 5a 4 k i "„R a - _-a .
vf
zs
ir
lb
e+
r
m K
z
.i
�. � � �+; ..� �. � �.,.act f _ � ` '" !r; �+r, ���-' `5•
a
:, .M e. • - � ;J � `., . s. ,. fit.• F +'*"� � ,.
-S,y •T . '�,.. _ +-.. ram{ "'M�"' { C•l`.
_ `.. sue,;,_ '. �. ..:.�... _ ' _.'.. �u •A.II � �. � `. •a _ . �. _ t. . ..� ��:+'.v
ev-Y"
file:HQ:\Documents\200411\ENF20040.042\4\GRAPEVIEWI.JPG 3,4 2009
a .
a
'L 1-r akr„ air.' ,'<•�� :t ,4 _
L o s _ ,_ tl?A'`.a,r. M.,•:� ! +.s; r I C t� �wy,1��jypf
lit
a p:
1, .A e.3is,�,;,.... � - x • � - !- +r�""'��'i•�'a� � )k�..�t tla ���1r� flw.aa•�'�zr�; �n,s �,,., �
- .t � " a r .� ' ,M�. `" Yea � 4 '�• '�
_ _ A
t
Aw
-
P* a
_ t r
aK a
a~
-r
r
,
r ,
r
,
w s
�._ .�t x .. 7��l `sR.''.� ,�, �:Z' .,'War.� . ...4�yd ��1•.��'.��YP.tl" .. .. �`.. �_.. ..tic
file://Q:\Documents\20041 1\ENF20040.042\4\4HALL.JPG 2/24/2009
Name O✓ Parcel# 1 .2-2 2 q 5-6 0 L CG BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/Commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone:(360)-427-9670 EXT.450
Mail:P 0 Box 1850,Shelton WA 98584
Physical:415 N 6th St,Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352
Mail: P 0 Box 1666,Shelton WA 98584
Physical:426 W Cedar St,Shelton WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X �( Owner/Agent/Contractor(circle one)Date: .2 - /D- 20cx,
Page 2 of 2
Name (3 QVe Parcel# 2 Z Z 9 5- " 2 O l 0 BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area "All dimensions in feet
Buildings X =
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page I of 2
3
r
S
2 }4}4}
I
Y \
�l ti
X 1
APPROVFO
� at� MAS N COUNTY DCD PLANNING
�o a ITE PLA3NREQUIRED TO RE ON ,ITE
t S BJEC1 TOAD f'Ru'JAL
1
5 � �YLW Date
Wetland and Buffer Enhancement Area Planting Schedulet'`s'v�' �`a- lt✓A�
I!A
Species Size Condition Quantity Spacing
��� r UCH
Red alder 2-3' Container or bare root 7 Q 10' on center
Nootka rose 2-3' Container or bare root 11 ❑ 10' on center
Hard hack 2-3' Container or bare root 11 Q 10' on center 4,kr2v N OVAL
Sitka willow 2-3' Container or bare root 10 0 10' on center
1C)f D
� J^ Fla_ ,!'� i ��� ►�.�.�—� , � .ge...
6�-
i_
�69 V'Oq ev-) �0,-P AC,
}
2
T �
f
vrow4rR�`+^`+n.+.+c�+�.b.rX..r<.✓�...\�Mw\Mh<�.cic1<aia'.^.ti'.•�• �yyrr-.V�....v�<.. -.............�.w.w.�.�..... ._,_ ,_. ......�.�.._................i-_._..+....v+..r.r`i,..