Loading...
HomeMy WebLinkAboutBLD2001-01080 Retaining Wall - BLD Permit / Conditions - 4/18/2002 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY Phone: (360)427-9670, ext. 352 DEVELOPMENT Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2001-01080 OWNER: DOUGLAS HASER RECEIVED: 10/15/2001 CONTRACTOR: NORTH BAY DEVELOPMENT CORP LICENSE: NORTHBL024MW EXP: 06/01/2002 ISSUED: 04/18/2002 SITE ADDRESS: 4410 E STATE ROUTE 302 BELFAIR EXPIRES: 10/18/2002 PARCEL NUMBER: 122214300150 LEGAL DESCRIPTION: TR 15 OF GOVT LOT 4 & SW SE & TAX 56-A-2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RETAINING WALL TAKE HWY 302 NORTH TO 4410 PERMIT NULL & VOID BY EXPIRATION DA.Tt (A-0 General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No. of Stories: Occ. Load: Building: Valuation: $7,125 Building Height: Occ. Status: Basement: Retaining 750 Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft Front: N 12.0 Ft. Shoreline: 180.0 Ft. Water Body: case inlet SEPA?: No Model: Width: Ft. Rear: S Ft. Slope: Ft. Shoreline Desi Urban Side 1: E 5.0 Ft. g.. Year: Serial No.: 11 Side 2: W 10.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KLW 10/15/200 $183,01 57610 Adjust Plan Check Fee DLC 10/19/200 -$83.40 1430 Building State Fee DLC 10/19/200 $4.50 1430 Building Permit Fee DLC 10/19/200 $153.25 1430 Violation Investigation Fee DLC 10/19/200 $47.00 1430 Violation Fee DLC 10/19/200 $111.25 1430 Shoreline Pre-Inspection GBM 11/01/200 $70.00 1430 Fww Total $485.61 BLD2001-01080 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2001-01080 CONDITIONS FOR BLD2001-01080 1) This applicati n is subject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 1�* 2) The use, handling and storage of hazardouq materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X -� 3) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work wIEK fect your project. X 4) Proposed structure or any portion thereof greater than 30" in height from rad line, must maintain a minimum of 5' setback from all property lines, easements and 10' from all County and State Road right of ways. X� 5) Strong tie expoxy use will require a WABO Certified special inspector or a certified testing laboratory to inspect the installation of grouted construction anchors as stated in the ICBO ER-5279 report. The agency shall complete complete a rep rt and submit the findings to the Mason County Building Department for review and approval prior to the final inspection of the project. X 6) This project is approved subject to a minimum setback of 10 feet from the road right of way as required by Mason County Ordinance No. 45-99, Amen ments to Title 14. X 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the Building Departmen prior to any further inspections being performed or approvals granted. BLD2001-01080 Please refer to the following pages for conditions of this permit. 2 of 4 8) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contrclqtor fail to post the address on site prior to requesting inspections. X 9) The "approved" plot plan is.required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour (minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 10) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee of$47.00 per hour (minimum 1 hour) will be charged and hall be collected by the Building Department prior to any further inspections being performed or approvals granted. X JjQ 11) 1997 UBC Chapter 17, Section 1701. In addition to the inspections required by UBC Section 108, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under UBC Se ion 1701.5. The special inspectors' duties & responsibilities shall be as specified in 1701.2 and 1701.3. X 12) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occuq�ncy, would result in permit revocation. X ,�`�i 13) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordin nce or regulation, must be reviewed and approved by Mason County prior to construction. X 14) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building X spec or all be made prior to requesting additional inspections. 15) All property lines shall be clearly identified at the time of foundation inspection. X �22 16) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-ggmPliarlt with Mason County ordinances and building regulations. X ` 1PI, BLD2001-01080 Please refer to the following pages for conditions of this permit. 3 of 4 17) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit h er ave prevented action from being taken. No more than one extension may be granted. X 18) All recommendations specified by the engineer of record, J Bartram, shall be followed including 1) specific material, such as turfstone which allows for grass, be installed in the area between the wall and the road and 2) a sign indicating "NO TRUCKS on shoulder." The engineer of record further states that proper maintenance shall be followed including limiting truck traffic (>10,000 GVW) be prevented from having their wheels within 8 feet of the walls, stormwater shall be diverted away from retained fills, remaining slopes shall be planted for erosion control, no excavations shall occur near the wall toe, and if wall movement, piping or similar problems occur the site shall be investigated and corrected. X� 19) All upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. OWNER OR AGENT: �r°�,5��/yim14 q DATE: BLD2001-01080 Please refer to the following pages for conditions of this permit. 4 of 4 MECHANICAL MOBILE HOME { CONCRETE by F tic date (date Ribbons data by Fdatfon Walks date Set up by date by INSULATION FFinN BCC by Floors by date by date date FRAMING Waft date DEFT. date by date by date by OTHER PLUMBING Attic Groundwork date by date byWALLBOARD NAIUNG D.W.V. dale by date by FINAL INSPEgTION Water Line date by date by date by r