Loading...
HomeMy WebLinkAboutFire Alarm Inspection - FIR Inspections - 10/22/2009 3 as 3 3 -so - Ono I Mason County Fire Marshal Inspection Contract No. Mason County Bldg. III File NO. 426 W. Cedar PO Box 186 Shelton WA 98584 FIRE ALARM SYSTEM REPORT OF INSPECTION Date: 10 a a -cx� Name of Facility: Alderbrook Inn Occupied as: Hotel/Resort Address: E. 7101 State Route 106 County: Union Zip: 98592 Telephone: 360-898-2200 Building Designation (if more than one building) Resort & Dock Acct #: 85-4921 Inspection by: .510ck(_1),P_ Title: Tech. Date of Inspection. tO —aa `d7 1. Type of Test: Monthly [ ] Quarterly [ ] Semi-Annual [ ] Annual [X] 2. Type of system: Noncoded [X] Common coded [ ] Selective coded [ ] Dual Coded [ ] (as pertaining to Chapter 212-14 WAC) 3. Local Fire Department: Mason County 898-4871 4. Fire Department Official Contacted: Rich Hienrich 5. Test Received at Alarm Center: N Yes ( ] No 6. Master Box Reset AM 61, 00 PM 7. All Tests Satisfactory Yes [ ] No / l 8. Comments, explanation of unsatisfactory results, action taken, etc.. /jSct`��l//�,c� pliptly ccv f a ! e .sA)A Original Form to be returned to Fire Marshal r - EQUIPMENT TESTED # of Units Test Satifactory Type of Equipment Tested Date Yes No N/A Type and Manufacturer 9. Control Panel '� FCI 7200 10. Manual Station 3 FCI 7200 11. Heat Detectors 3 R ✓o 6(onec 12. Smoke Detectors C�c) 13. Audible Alarm Devices 14. Visual Alarm Devices kGe ��. 15. Code Transmitters X 16. Automatic Door Releases ( C) 17. Trouble Indicators 18. Master Alarm Box X 19. Batteries j 5 ASC 12/7 & 2 12/18 20. Charger 21. Generator X 22. Ventilation Control X 23. Fire Dept Interconnection X 24. Central Station Interconnection i/ H 25. Ext Sprinkler Elec Alarm Bell 26. Sprinkler Water Flow Switch 27. Sprinkler Gate Valve Super Switch po��e 28. Annunciators 2L I FCI 29. Automatic Time Delay of General Alarm Minutes. None Installed �t]. 30. Test of alarm system on-emergency power, satisfactory? [( Yes [ ] No 31. This is to certify that this fire alarm system has been properly inspected for reliability covering the items listed in this report and is consistent with NFPA fire alarm Maintenance Standards. A. Signature of Owner or Representative B. Signature of Fire Alarm Firm Repesentative : r7�56­ C. Name of Firm: PIONEER FIRE & SECURITY, INC. D. Mailing Address: PO Box 597, E. Olympia, WA 98540-0597 Phone No. 360-491-8141 E. Electrical Contractors License #: PIONEFS963LC Original Form to be returned to Fire Marshal