Loading...
HomeMy WebLinkAboutBLD2006-01358 Final Replace Bulkhead - BLD Permit / Conditions - 11/1/2007 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 A. Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 IP4 RESIDENTIAL BUILDING PERMIT BLD2006-01358 OWNER: MAXINE CLOW RECEIVED: 7/28/2006 CONTRACTOR: JAPHET BULKHEADING INC 360-866-0377 LICENSE: JAPHEB1168LH EXP:6/14/2007 ISSUED: 8/30/2006 SITE ADDRESS: 220 N AYOCK BEACH DR LILLIWAUP EXPIRES: 2/28/2007 PARCEL NUMBER: 323035001015 LEGAL DESCRIPTION: AYOCK BEACH BLK: 1 LOT: 15 PROJECT DESCRIPTION: DIRECTIONS TO SITE: REPLACE 15' OF FAILED WOODEN BULKHEAD WITH CONCRETE TO NORTH ON HIGHWAY 101 TO AYOCK BEACH DRIVE. PROTECT THE SEPTIC TANK FROM EROSION. THE EXISTING WOODEN BULKHEAD FAILED DURING THE 2006 STORM. General Information Construction&Occupancy Information Square Footage Information No.of Bedrooms: Type ofConstr.: Type of Use: SF Insp.Area: No.of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: RW Fire Dist.: 17 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: bulkhead 170 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Hood Canal SEPA?: Yes Model: Width: Ft. Rear: Ft. Slope: Ft. Shoreline Desi Side 1: Ft. 9•: Urban Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KKK 7/28/2006 $39.07 S22006000 Planning Review Fee KKK 7/28/2006 $155.00 S22006000 ADJUST--Plan Check Fee RTB 8/29/2006 $15.04 §22006000 Building State Fee RTB 8/29/2006 $4.50 S22006000 Building Permit Fee RTB 8/29/2006 $83.25 S22006000 Total $296.86 BLD2006-01358 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR .. BLD2006-01358 CONDITIONS FOR BLD2006-01358 1) Water qualit of to be degraded to the detriment of the aquatic environment as a result of this project. X � t 2) Prior to fin val, all upland areas disturbed or n Jvl reated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X ` 3) The proposed project must be consistent with all I a�policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program.X 4) All construction and demolition debris must b re oved from the beach after project completion40djac'ent isposal of construction debris must be on land in such a manner that debris cannot enter or ca se water quality degredation of State waters. X 5) Temporary erosion control measures must be implemented to prevent water quality degradati i waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X L 6) Approv r dimensions and setbacks on submitted site plan. Setbacks are measured frLo,6hu'rthest projection of the structure. X 7) All o essary permits from Mason County, Washington State and/or Federal Agencies that are requ' e r this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION.X IT 8) Replacement of bulkhead is for the sole purpose of protecting septic tank from erosion. The septic to t be monitored so any erosion can be addressed immediately. Any questions regarding the condition of the septic tank should be directed to the Mason County Dept. of Environmental Health. 9) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be gr d. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depa rior to any further inspections being performed or approvals granted. X BLD2006-01358 Please refer to the following pages for conditions of this permit. 2 of 4 101 In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting in t ns. X 11) roved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approv I w' not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildi D rtment prior to any further inspections being performed or approvals granted. X 12) Co cre d for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertic co cr to work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 13) Any kha es ' proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Depa ent prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. 1"w--,yments are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged n� hall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 14) All con�ruc, ust meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of 1 on. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev c ti X 15) All chan as �' proved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance r btion, must be reviewed and approved by Mason County prior to construction. X 16) CONST UC ,IO PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDIN The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the ' to ational codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect r s �I be made prior to requesting additional inspections. X 17) All pr e I' es shall be clear) identified at the t'y e time of foundation inspection. BLD2006-01358 Please referto the following pages for conditions of this permit. 3 of 4 18)• All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure • to re ea final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Masounty ordinances and building regulations. X 19) All p s expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hass 'eate prevented action from being taken. No more than one extension may be granted. X 20) P wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connecto a d lashing. Install metal connectors approved for contact with the new types of pressure treated material. X 21) Must m co tions of SEPA see SEP2006-00122 22) This permit has been reviewed and approved as a temporary erosion control bulkhead only. Applicant/owner certifies that it is not intended to support surchar a f,(om upland sources or structures. Owner shall continuously monitor bulkhead for signs of failure and take remedial action as necessary. Prior approv I rbr Mason County is required for any bulkhead maintenance, repair or construction. X ju This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a rogress ins tion.The ow er or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described Ordlperty-wfJ strbcture for revi+and inspection. OWN ER OR AGENT: 1 ` DATE: r i BLD2006-01358 Please refer to the following pages for conditions of this permit. 4 of 4 W o CONCRETE MECHANICAL MANUFACTURED HOME r_ o Date 0 Footings/Setbacks Gas By Ribbons 0 Interior Date By interior-Date By Daps By CnExterior Date By Exterior-Date B INSULATION Set-upPoint Load l Isolated Footings Date By Z BG 1 SLAB INSULATION M Date By Date By FIRE DEPARTMENT Foundation Wails Floors Date By Date By Data By DECKS FRAMING Walla Date By Dale By Data By PROPANE TANKS PLUMBING vault Date By Date By OTHER _^ ^ Groundwork Attic Date B Date By Type: y Date By D.W.V DRYWALL Type: Int Brace Wall Date By W � Date By Dam By FINAL INSPECTION 2 Water Line Fire Separation C 2 Date By Date By Date By O m � Pass or Request Inspect. 0 Type of Insp. Fail Date Date Done By Comments w 00 a 0 � T SEcri�u 70 Fix3V)' s kA I1S 9 1p 14 r, 9 b 14, a 8 o_ 0 0 m El O I MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 0 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR I3F9RMATION Owner •#",Q It I rji JOLe) Company Name P► gajkk f* d#X* I me. Mailing Address 2=O /4 0 nk L — Mailing Address /`/()`i' -,,,,,,,. Re f1i60 City It 1�Av State Zip Code Ss . City�/ �9 State Zip Code -s1D Phone Other Ph.—__----_, Phone 3 0-fs66-136 Oth h. Lien/Title Holder __ _�_�� Contractor Reg. xp. .o� ,--. E mail address E Mail Address L�F P l ov►�eRST Ivt / Drivers Lic. # DOB _ Drivers Lic.# _ " DOB s ` SEPTIC / WATER SYSTEM INFORMATION - Connect to New Septic Existing Se i Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. 3ZLr: x Svca/C/S Fire District Legal Description Site Address (Pleasq include street name, street num er a,�} city) 2 o W / A0 Directions to site �'I �� / o C O r Will timber be cut and sold in parcel p eparation?Yes o Is property within 200' of Saltwater _ Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair Other6,4kja PRIMARY RESIDENCE [�]. SEASONAL ❑ Use of Building Describe Work U & No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEAT OFAPROGRESSINSPECTION.INACTIVITYOFTHISPERMITAPPLICATIONOF180DAYS WILL INVALIDATE THEAPPLICATION. X _�- Dater Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW AP OVED UNJED NOTES Building Department }9 G� Planning Department 3 Environmental Health Department Fire Marshal FEES Building Permit Fee 3_ Site Inspection Plan Review Fee S—L/� EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee `� - Other Wood /Gas/ Pellet Stove Fee _ State Fee . S Violation Fee - '- D 6 Pre-Paid at Submittal Valuation $ TOTAL FEES 7 0 -"--- Existing Bulkhead 8„ Rep #4 Gr.60 12" OC Horiz. #4 Gr. 60 8" OC Vert. 6'-0" 14.4'Tidal level Beach matt. 5° sand & gravel 2" Drain 8' OC o —o- 1 W 4'-0" —0 Notes: Property owner: Concrete: Cys 6 sack to the yard mix Maxine Clow Concrete below MHHW: Cys N 220 Ayock Beach Dr. Reinforcement: All #4 Gr.60 , 2.5" min. coverage Lilliwaup WA 98555 Wall: 8" OC vert. 12" OC horiz. Par# 32303 5001 01 5 Footing: 8" OC cross 12" OC run Sec 3 Twp 23 Rg 3W Drains: 2" drain 8' OC entire length Lat N 47.30.43 Top of footing min. 18" below beach grade Long W123.03.24 All work to be done at periods of low tide Applicant/Contractor: No construction debris will be left on beach Japhet Bulkheading Inc. 1407 Summit Lake Shore Rd. Nw. Olympia, Wa. 98502 Ph. (360) 866-0377 Fax (360)866-7702 Lic.# JAPHEB1168LH Owner Maxine Clow N220 Ayock Beach Dr Lilliwaup WA 98555 �S ��Q3J M 9Zb Site: Plot/ Site Plan 9001 220N Ayock Beach Dr. R a 7nr Lilliwaup WA 98555 Scale 1 /16' Q3�'3 County of Mason ��1, State of Washington �J HOOD CANAL Lat. N47.30.43 Long. W123.03.24 Par# 323035001015 Purpose: Residence had a 15' section of wood bulkhead that was lost in a storm early 2006,13each erosion is threatening the residence and septic system Proposed: Install a concrete bulkhead to protect the residence and septic system APPROVED Contractor/Agent: Japhet Bulkheading Inc. "',SC ��JUNTY DCD PLANNING 1407 Summit Lake Shore Rd NW SITE PL.' l REQUIRED TO BE ON SITE Olympia, WA 98502 CHh 4,;-; SUBJECT TO APPROVAL3 360-866-0377 JAPHEB1168LH gy Date Maxine Clow N220 Ayock Beach Lilliwaup, WA 98555 Par# 323035001015 N.Prop Line N Septic Tank 15, N.Prop Line Replacement bulkhead •• • • • location of Richard Chester destroyed 20429 Welsh Rd wood Snohomish WA bulkhead 98296 Site: 230 N Ayock Beach Dr Concrete bullkhead Lilliwaup, WA to be built July 06 I Sa � Y �,�; � _ ,• - � -_ . - � - --� ��--- --1-�=- ---�_ � � . -� _ �- � '. •�-= - .�- L 1 .. _.. �_ _ �� i