Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2004-00119 Cancelled Addition - BLD Permit / Conditions - 9/28/2006
Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNI•T Y DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton,WA 98584 M_Iplo RESIDENTIAL BUILDING PERMIT BLD2004-00119 OWNER: DANIEL BYRNE RECEIVED: 2/4/2004 CONTRACTOR: LICENSE: EXP: _. i C ISSUED: 3T1/2004 SITE ADDRESS: 3862 E STATE ROUTE 302 (HO) BELFAIR EXPIRES: 9/1/2004 PARCEL NUMBE 2-13'M00094.- LEGAL DESCRIPTION: SURVEY 16/120 PCL 2 BLA#93-95 AF#578192 3862/3864 E STATE HWY 302 BELFAIR PROJECT DESCRIPTION: DIRECTIONS TO SITE: ADDITION hway 3 to Allyn, right onto North Bay Road to State Route 302, follow approx. 4 m address on right(water side) General Information Construction &Occupancy Infor tion Square Footage Information No.of Bedrooms: 0 Type of C tr V-N Type of Use: SF Insp.Area: No.of Bathrooms: 4 G R-3, U-1 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No.of Stories: 2 oa Building:2,897 Garage-Attached 725 Valuation: Building Height: 22 cc. S S. Primary Basement: Covered 230 Manufactured Home Information Setback InformN4k IShoreline&Planning Information Make: Length: Ft. Front: E 152.0 Ft. Shore e: 96.0 Ft. Water Body: CASE INLET SEPA?: No Model: Width: Ft. Rear: W 96.0 Ft. to e: Ft. Shoreline Desi Side 1: N 37.0 Ft. g.: Urban Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Type By Date Amount Receipt Hosebibs 1 Furnace<100K 1 Plan Check Fee TW 2/4/2004 $966.26 S12004 Kitchen Sink 1 Ventilation Fan 4 Planning Review Fee TW 2/4/2004 $155.00 §i2bb4 Lavatories 5 Heat Pump 1 Adjust Plan Check Fee JRN 2/11/2004 $94.64 S22004 Water Closets (Toilets) 4 Building State Fee JRN 2/11/2004 $4.50 S22004 Water Heaters 1 Building Permit Fee JRN 2/11/2004$1,632.15 S22004 Bath Tubs 3 Mechanical Fee JRN 2/11/2004 $54.45 S22004 Mechanical Base Fee JRN 2/11/2004 $23.50 S22004 Plumbing Fee JRN 2/11/2004 $98.00 S22004 Plumbing Base Fee JRN 2/11/2004 $20.00 S22004 _ EH Plan Review PSD 2/12/2004 $35.00 S22004 Total $3,083.50 BLD2004-00119 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR B LD2004-001'I 9 CONDITIONS FOR B LD2004-00119 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X N 2) The Uniform Fire Code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such Monnect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department Drior to any further inspections being performed or approvals granted. X __� !�a 4) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contra ail to post the address on site prior to requesting inspections. X 5) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans n or the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 6) All slabs within the heated space shall be insulate 1 a inimum R-10 for at least 24". Monolithic slabs shall be insulated around the perimeter from the top of the slab to the bottom of the footing X 7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X r BLD2004-00119 Please referto the following pages for conditions of this permit. 2 of 4 'proved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"plot plan is not on site, then 31 will not be granted. In addition, a re-inspection fee (refer to current fct-schedule, minimum 1 hour)will be charged and shall be collected by the a Department prior to any further inspections being performed or approvals granted. 9) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and al a collected by the Building Department prior to any further inspections being performed or approvals granted. X a r 10) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X � 11) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X , 12) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X �Z2 13) THE D ITION AND DISPOSAL OF DEMOLITION DEBRIS MUST MEET REQUIREMENTS AS PER MASON COUNTY REGULATIONS. X 14) All property lines shall be clearly identified at the time of foundation inspection. X 15) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason nt ordinances and building regulations. X 16) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X P' 17) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connec�to , and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X IW 18) Approved per dimensions and setbacks on submitted site plan. X BLD2004-00119 Please refer to the following pages for conditions of this permit. 3 of 4 ;ies null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is J!Wscribe Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of eans of a ro ress inspection.The owneror the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above de proper nd structure for review and inspection. _ raj t OWNER OR GEN DATE: BLD2004-00119 Please referto the following pages for conditions of this permit. 4 of 4 U N CON(;RETE MECHANICAL MANUFACTURED HOME CD CD cyl Footings I Setbacks Date BY Ribbons Date By Gas Piping_ g Date By Foundation Walls Date By Set-up Date By INSULATION Date By BG A Stab insulation Floors FINAL I NSPECTION Date By Date By Date By FRAMING wails FIRE DEPARTMENT Date By Data By Date By PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING [}.W.Y Gate By Date By Water Line FINALINSPECTION Dato By Date By Date By 0 Type of Insp_ Pass/Fail Request Date Inspect. Date Done By Comments 61 A I, l R DS 1 b � > T- �64© CIO d CD ((D O 8 -ICE 'R"l E PP6640 1 Z-LD t ID-6- l C6- LS C� C7v CL zvC ► e- n N t1 b U FK - 5 -c t:2 ©� D3 oh Cat 105/06 IT US At► E"� wac( I s +- CcECc 0 � q N 1 N psi -r- o QONCRETE MECHANICAL MANUFACTURED HOME o — Footings / Setbacks Date B y Ribbons o Date 3-27-may By '/� Gas Piping Date B y Q Foundation Walls Date B tr Set-up Date By INSULATION Date By B G / Slab Insulation Floors Final Date By Date R / 6� P�YUPf Date By FRAMING Walls FIRE DEPT Date / Z -s= 0,5—By Date B y Date By PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING D.W.V. Date By Date S -- 2q -DSBy 4-/2C FINAL INSPECTION Water Line Date By Date -Lq .- OS By A/1C- Date By m Cn 0 0 �7' cn 8L��e �`,/ N ' -r✓ '` CL fQ - F M IB os os' (�CS N I u s ✓ o T o CD 1 S Cks.5 E "V k m Ft R ' o� R� Z 3 Z2:3 0 5- 2-1 /65- 'A le 'Dw IJ 5� /� P955 r:D `V � � o ry-& G rn , , �sZ1�v t' 1/10 t- t-pJ V- vru d0 Ge• S W V : S ti tT�,,,,,,� M g Permit # ��� MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 396Z EST 302 13y This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance ` T r- Ci s F2 Z "1Z cue -U S Z �FcoeD !>re- inkz-V You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection This is not a complete inspection Department Date D 'Z� l Inspector " son NooT Mo *V ' THt , T ,OL ' F3uild4�.F'ermit # Oy MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 38hz L This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been f d: Items Listed below must be corrected to gain code compliance 'AT Lc ' 2" D/Y 02 GA Gv s, E, C, we u EQ ' w Also t-v d 8 nd 04 cm Ale Ftoav' l.t)C F a Ci Q You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK q'Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to This is not a complete inspection Department Date /2-T LO�- Insp or Do * EmOsT MOOV THI Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 26 i��� � This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 42e G You are hereby notified that the above corrections shall be made. BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to P_-) !wi 0/?,y tL_ - This is not a complete inspection Department Date �� Inspector ■ isk s NOT ,MOOV THI ,Iqwft T ' ,�� rig i, op) n "tire "A � � � .7GIs n�-�al ��� .. n Wad L s Pi-D slab � m Gar �- c�c��"' S h�i.► b� p Pl-pyovide- d'e-fr-i' k5 ine� . v J CIVIC c b�e d uc-I- /d ftu AWN BY _ VISED AWING NUMBER �. v Building Permit # O — 06111 MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance �e� 50110 jf' k0+C.1cin!3 NtC--nE-O 'lli6 .5 /12c=i=-6 If U,1,4115 c 2 oeet'i< u. ocv% :�..s� l•�� .� . 1. SQ/,-<J /vim 5ei9Lnl r> o F A 4c-w'4 d 5 C-X - Ott � w� ink, #)I c +2 Sh e7A-,z �-�.„a a7 .1-_ry . C c c H 25e c2 ('pvee,"," c .r pre Oc viov o� o 2 r t Vol c� � You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK xCall for re-inspection when corrections are made before continuing Q Make corrections, items will be checked on next inspection C�-B+E-to 'pa Nc+ ':T7u5u 1A4-C 0 427R5 a C�K-p jdv►�l ❑ This is not a complete inspection Department ( D Dc.D Date `t c s �' t2 Inspector A 2G L 0 It nnN * *T 'i , M0V ', TH1VftkTm ,f%w Building Permit'# �' MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 ORRECTION NOTICE Job Location ffV/7r1/ Sew Z \r-'zfi c-7?� This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 4�,� t-ri�GL ,o/S��✓r9 Gs GL _/ ` f r A S /S AZ �/''J�' !�-�16J�G7lc�.✓ cf�g'� d,I�e= �.��d�� Td You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department Date l© ' 2 cf Inspector —7 _ ■ *0 NOOT ' MO *V THlqqftk T ' ,Oqi IP14Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma Shelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection January 07, 2008 DANIEL BYRNE 3862 E S.R. 302 BELFAIR WA 98528 Case No.: BLD2004-00119 Parcel No.: 122213100080 Proiect Description: ADDITION The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from the date of this letter. Failure to contact our office to make the necessary scheduled inspections will result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $68.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you will be charged $68.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 359. Sincerely, Terry Ryan Mason County Departm' nt of Community Development Cc: Property File January 07, 2008 BLD2004-00119 8/23/2005 Case Activity Listing 3:10:47PM Case#: BLD2004-00119 i� Assigned Done Activity Description Date I Date 2 Date 3 Hold Disp I'o By Updated Updated By BLDC140 Framing/Plumbing/Mechanical 7/22/2005 7/25/2005 None FAIL MEC 7/26/2005 MRB NOT READY WENT OVER ITEMS WITH OWNER 1.INSTALL CAULK AND SEAL PACKAGE 2. PUT DWV UNDER TEST 3.SEAL FLOOR PENETRATIONS AT TUB/SHOER DRAINS USE 12"PLY OR FLASHING 4.GARAGE MUST MEET WSEC TO BE HEALED CLOSE OFF DUCTING WITH NON OPENABLE COVERS 5.POSITIVE CONNECTION REQ'D WHERE RAFTERS MEET VALLEY RAFTERS ALSO HURRICANE TIES NEEDED AT MIN 48"O/C 6.SOLID BLOCKING NEEDED WHERE ROOF MEETS WALL 7.DRILL OUT RAFTERS FOR COMMUNICATION AIR FLOW 8.BLOCKING REQ'D AT DROP CIELINGS BLDC140 Framing/Plumbing/Mechanical 8/17/2005 8/18/2005 None FAIL TFR 8/19/2005 KLW NOT READY, 1.DISCONNECT GAS PIPE AND PUT UNDER TEST,2.NO PLANS OR PERMIT ON SITE NO INSPECTION 3.#1,3,6,4,NOT DONE FROM LAST INSP DO NOT DRYWALL. BLDC140 Framing/Plumbing/Mechanical 8/18/2005 8/22/2005 None FAIL RLS 8/23/2005 KLW ITEMS BELOW 1.NO COUNTY APPROVED PLANS,2.DWV NOT UNDER TEST,3.DISCUSS ENERGY TRADE OFF FOR HEATING GARAGE,WITH DEBRA COKER EXT 510,4. DISCUSS WITH LARRY WATERS ABOUT FIRE DAMPER FOR HEAT DUCT OPENINGS,5.CHANGE FIRE SEPERATION FROM 97 UBC TO 2003 IRC. BLDA910 Meeting 8/23/2005 None DONE RTB 8/23/2005 RTB new contractor came in asked for a copy of plans also attached letter allowing occ.seperation from 2003 IRC instead of 97 UBC 8-23-05 RTB BLD13007 Plan Revisions Submitted 8/23/2005 None DONE DLC 8/23/2005 DLC VNEC- Options approved as follows: HEATED GARAGE: Fire damper required,R-0 slab,R-0 concrete walls,R-21 walls,insulated/weatherstripped doors. Information about garage doors required at inspection(final?) UNHEATED GARAGE: Insulate ducts,remove heat diffuser in garage,R-30 in ceiling of garage. D Coker-8/23/2005 Page 2 of 2 CaseActivity.apt