Loading...
HomeMy WebLinkAboutGEO2010-00018 for BLD2010-00278 - BLD Engineering / Geo-tech Reports - 6/8/2010 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Planning Division P O Box 279, Shelton, WA 98584 11910 (360)427-9670 Geotechnical ReportReview Acceptance Letter June 08, 2010 MICHAEL LEENHOUTS 3016 NIAGARA ST BELLINGHAM WA 98226-4216 Case No.: GE02010-00018 Parcel No.: 322365100011 Proiect Description: GEO REPORT SUBMITTED FOR BLD2010-00278 The Geotechnical Report for MICHAEL LEENHOUTS has been received and reviewed by the Planning Department. The report was prepared by Alan Tahja dated 4/26/2010. Based on the certification provided by the licensed engineer/geologist, the referenced Geotechnical Report was prepared in general accordance with the requirements in the Mason County Resource Ordinance, Landslide Hazard Areas 17.01.100.E.5. Mason County considers the review valid until such time as scope of project, site conditions, and/or regulations change. Should the scope of work, site conditions, and/or regulations change after the original review, then an addendum from the original author of the report may be required to address these changes. The report would only be re-reviewed if a permit for development were submitted after these changes occur. Mason County does not certify the quality of the work done in this Geotechnical Report. Please contact me at (360) 427-9670, ext. 365 if you have questions. Sincerely, Z�Z N � Allan Borden Land Use Planner Mason County Planning Department Comments: 6/8/2010 Page 1 of 1 GE02010-00018 RECEIVED �&o Zv Io - 6(oc) 18 APR 2 9 2010 FnL -61d W1 D QO 278 426 W. CEDAR ST. Mason County Department of Community Development Submittal Checklist For a Geotechnical Report Instructions: This checklist must be submitted with a Geotechnical Report and completed, signed, and stamped by the licensed professional(s)who prepared the Geotechnical Report for review by Mason County pursuant to the Mason County Resource Ordinance. If an item found to be not applicable, the report should explain the basis for the conclusion. Applicant/Owner Michael & Becky Leenhouts Parcel# 32236-51-00011 Site Address 100 E Pebble Beach Lane,Union, WA 98592 (1) (a)A discussion of general geologic conditions in the vicinity of the proposed development, Located on page(s) _Pages 1 —3 (b) A discussion of specific soil types Located on page(s) Pages 2-3,4& 5 (c) A discussion of ground water conditions Located on page(s) Page 2 (d) A discussion of the upslope geomorphology Located on page(s)_Pages 1 -3 (e) A discussion of the location of upland waterbodies and wetlands Located on page(s) Page 2 (f) A discussion of history of landslide activity in the activity in the vicinity, as available in the referenced maps and records Located on page(s) Page 2 (2) A site plan which identifies the important development and geologic features. Located on Map(s) Plan Sheets 1 &2 (3) Locations and logs of exploratory holes or probes. Located on Map(s) Plan Sheet 2 (4) The area of the proposed development, the boundaries of the hazard, and associated buffers and setbacks shall be delineated (top, both sides, and toe) on a geologic map of the site. Located on Map(s) Plan Sheets 1 & 2 (5) A minimum of one cross section at a scale which adequately depicts the subsurface profile, and which incorporates the details of proposed grade changes. Located on Map(s) Plan Sheet 3 & GALENA Stability Printout Shts 1 &3 (6) A description and results of slope stability analyses performed for both static and seismic loading conditions. Analysis should examine worst case failures. The analysis should include the Simplified Bishop's Method of Circles. The minimum static safety factor is 1.5, the minimum seismic safety factor is 1.1. and the quasi-static analysis coefficients should be a value of 0.15. Located on page(s) Page 4 (7) (a)Appropriate restrictions on placement of drainage features Located on page(s) Page 4 (b) Appropriate restrictions on placement of septic drain fields Located on page(s) Page 1 (c) Appropriate restrictions on placement of compacted fills and footings Located on page(s) Pages 4& 5 Page 1 of 2 Form Effective June 2008 Disclaimer: Mason County does not certify the quality of the work done in this Geotechnical Report. (d) Recommended buffers from the landslide hazard areas shoreline bluffs and the tops of other slopes on the property. Located on page(s) Page 4 and Plan Shts 1 & 2 (e) Recommended setbacks from the landslide hazard areas shoreline bluffs and the tops of other slopes on the property. Located on page(s) Page 5 and Plan Shts 1 &2 (8) Recommendations for the preparation of a detailed clearing and grading plan which specifically identifies vegetation to be removed, a schedule for vegetation removal and replanting, and the method of vegetation removal. Located on page(s) Page 5 (9) Recommendations for the preparation of a detailed temporary erosion control plan which identifies the specific mitigating measures to be implemented during construction to protect the slope from erosion, landslides and harmful construction methods. Located on page(s) Page 5 and E&S Plan Sheet (10) An analysis of both on-site and off-site impacts of the proposed development. Located on page(s) _ Page 5 (11) Specifications of final development conditions such as, vegetative management, drainage, erosion control, and buffer widths. Located on page(s) Page 5 (12) Recommendations for the preparation of structural mitigation or details of other proposed mitigation. Located on page(s) Page 5 (13) A site map drawn to scale showing the property boundaries, scale, north arrow, and the location and nature of existing and proposed development on the site. Located on Map(s) Plan Sheets 1 & 2 I, Alan A. Tahia,P.E. hereby certify under penalty of perjury that I am a civil engineer licensed in the State of Washington with specialized knowledge of geotechnical/geological engineering or a geologist or engineering geologist licensed in the State of Washington with special knowledge of the local conditions. I also certify that the Geotechnical Report, dated 4/26/2010 and entitled Leenhouts Geotechnical Report meets all the requirements of the Mason County Resource Ordinance, Landslide Hazard Section, is complete and true, that the report demonstrates conclusively that the risks posed by the landslide hazard can be mitigated through the included geotechnical design recommendations, and that all hazards are mitigated in such a manner as to prevent harm to property and public health and safety. (Signature and Stamp) pF WASy 76 �O 4 �014 ���STER�� �ww ssjONAL Page 2 of 2 Form Effective June 2008 Disclaimer: Mason County does not certify the quality of the work done in this Geotechnical Report. TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Mason County DCD �� A. 1' Planning Division y of WAgJ�! PO Box 279 Shelton, WA 98584 Michael&Becky Leenhouts 3 016 Niagara St 01;'�, CI ST V, Bellingham, WA 98226-4216 SSIONAL (360) 739-5537 (cell) Re; Geotechnical Report Hazard Area Reduction Request 100 E Pebble Beach Lane Union, WA 98592 Parcel No.: 32236-51-00011 Case No.s: SWG97-00435,DDR2010-00035 BLD2010-00278 Mason County's geotechnical document review process will determine that the proposed Michael and Becky Leenhouts residential improvements on their 100 E Pebble Beach Lane property in Union, Washington, Mason County,will result in encroachment inside the 50-foot vegetated Hazard Area Buffer required under Resource Ordinance 17.01.100. Stability analysis of the slopes located on the northwesterly portion of the site between the existing residential features and State Route 106 at the toe of the steep slope (>40%) is itself stable and not likely to produce any slope instability as a result of the Leenhouts' proposed activities. The currently proposed residential remodel and residence addition on the location of the existing concrete patio are proposed to be inside the 50-foot Hazard Area buffer. With the exception of an existing garage,the existing property improvements are all already inside the 50- foot hazard area buffer. A Hazard Area Buffer reduction down to as little as 5-feet is requested for future residential development of the Leenhouts' property. This reduction request is equivalent to a request for an intrusion as great as 45-feet into the hazard area buffer. These requests are predicated on residential foundations being excavated to such depths that the foundation footings bear on the natural undisturbed glacial till soil layers underlying the site. Therefore, on behalf of the Leenhouts, I request that a reduction in the Landslide Hazard Area buffer required in Section 17.01.100 be reduced to as little as 5-feet for 100 E Pebble Beach Lane to allow the construction of currently proposed development of the property as promoted in my site plans and geotechnical report dated 4/26/2010, and building construction plans as prepared by Tami Selby of SELBY DESIGNS, LTD. Sincerely, c�4' v A an jA. Tahja, File:C.TrojecWLeenhoutsIHA Buffer Reduction Rqst 1 of 1 4/26/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Mason County DCD Planning Division PO Box 279 Shelton, WA 98584 Michael& Becky Leenhouts 3016 Niagara St Bellingham, WA 98226-4216 (360) 739-5537 Re; Geotechnical Report 100 E Pebble Beach Lane Union, WA 98592 Parcel No.: 32236-51-00011 Case No.s: SWG97-00435, DDR2010-00035 BLD2010-00278 INTRODUCTION I was contacted in mid April this year by Mr. Mike Leenhouts who requested my investigation and documentation of slope stability and landslide hazard issues relating to the remodeling and addition to their seasonal residence located approximately 0.1 miles up E Pebble Beach Lane from US Highway 106, approximately two miles west of Twanoh State Park. The property is identified as Mason County tax parcel number 32236-51-00011. I visited the site on April 22°d and 25d'of this year to collect topographic information and verify measurements and feature locations. Measurements were made using a 4-foot Soil Probe Rod, a Sokkia model No. 8047-55 inclinometer, 100 foot and 300 foot long fiberglass surveyor's tapes and other field equipment common to surveying. Software employed in creating a site plan and writing this report included AutoCAD 2006, a SoftreeTM Terrain 3-d contour modeling program, GALENATM Slope Stability Analysis software and Microsoft Office Word 2003. Arial topography and an elevation datum were developed from Mason County's website GIS mapping. The site is generally located on the northerly facing hillside located along the south shore of Hood Canal. The steepest slope in the vicinity of the Leenhouts property was found to be a slope paralleling Hood Canal on the Leenhouts property approximately 85 feet southeast of Hood Canal's southerly shoreline. The slope between the level portion of the Leenhouts property and the toe of slope at the Highway 106 elevation measured approximately 75%over an elevation difference of approximately 30+feet. E Pebble Beach Lane, a private road, generally defines the Leenhouts' southeasterly property boundary. A site plan is appended to the end of this report to help visualize the property's layout and topographic features. The Leenhouts property includes a recently upgraded(SWG97-00435)onsite septic system,two residential features and a detached residential garage. File:C.1Projects1LeenhouWGeo-Rpt 1 of 6 4/26/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 With slopes on or within 300 feet of the property exceeding 40%with a height of 10 feet or more, Mason County requires a geotechnical report to be developed to address stability issues relating to the property's development or improvement. Mason County classifies properties with a slope exceeding 40%as a Landslide Hazard Area and are further designated b the County as "critical � Y tY areas requiring immediate protection from incompatible land uses.", requiring the preparation of a geotechnical report. Mason County's Resource Ordinance stipulates "The intent of the Geotechnical Report is to specify how hazards are to be mitigated when development is proposed within the landslide hazard area itself or its buffers or setbacks.". This report is intended to show how development can be mitigated and occur within the landslide area buffer on the Leenhouts' property. The following thirteen elements are required by Mason County to be addressed in geotechnical reports prepared to comply with Mason County's Critical Resource Ordinance Sections 17.01.100 through 17.01.104. 1. SURFACE AND GEOLOGIC CONDITIONS: The property has been logged in the past,but has second growth timber scatter over most of the property's unimproved areas generally either on the slope between the dwellings and the highway or between the garage and Pebble Beach Lane. The vegetated areas of the property are covered with young and medium aged second growth Douglas Fir, Hemlock, Cedar trees and low growing native vegetation,mainly Salal, Oregon Grape, and Huckleberry plants. The south shore of Hood Canal in this area is comprised mainly of steep slopes which connect the sea level elevation of Hood Canal northwest of the Leenhouts property and the relatively level upland area approximately a quarter mile southeast of Hood Canal,typically at less than a 600 foot sea level elevation. Washington State's Coastal Atlas indicates the Leenhouts property is located in an area of"Intermediate" stability,typically stable but susceptible to instability if disturbed. No wetlands or upland water bodies were found or observed during the property's reconnaissance/inspection. Surface soils may become saturated through the course of the wet season, but the static groundwater elevation likely coincides with the tide elevation of Hood Canal. Inspection of the Geologic Map of Shelton 1:100,000 Quadrangle, Washington' on the following page finds the property located in an area between Hood Canal to the northwest, and an upland area southeast of Hood Canal. The map reveals that the site soils are classified as Continental Glacial Deposits, Fraser Glaciation,Vashon Stade(Qga),which are further described on the following page. Inspection and soil analysis finds the soil to be classified under the Unified Soil Classification System(USCS)as a coarse grained soil with a fairly high percentage of fines which gives it a dual soil classification of GW-SW. Probing areas of the property with a titanium probe rod, inspection of the cut banks located along Jenn's Way, and inspection of soil log holes excavating for designing a new septic system drainfield found a fairly uniform soil layer of the loamy sandy gravel to a depth of 50 feet or more underlain by a consolidated glacial till layer. The shallow surface soil(s)displays a modest amount of cohesion,but most of the soil's strength is derived from its granular texture and internal friction characteristics of the soil. 1 DNR OFR2003-15 Geologic Map of Shelton 1:100,000 Quadrangle,Washington File:C:IProjectslLeenhoutslGeo-Rpt 2 of 6 4/26/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Advance outwash,late Wisconsinan (Pleistocene}—Glaciofluvial sand and gravel and lacustrine clay,silt,and sand deposited during the advance of glaciers;sandy units commonly thick,well sorted,and fine grained,with interlayered coarser sand,gravel,and cobbles and silt rip-up lag deposits at their base;may contain nonglacial sedi- ments;generally overlain by till. Fault n '.:, Q g a -S\-� �, Qa ogo Qap Qapo �, ✓,. J ga Qgo 1 Qa Qgt J Qapo Tah u va Q Qga � BE'f1(� - °tas Allapo `- �r Qis _ Bail �v � Qa Qapo - - Qapo �� � --� i L?apo Leenhouts Site Qga. 1-� 2. SITE PLAN WITH IMPORTANT DEVELOPMENT AND GEOLOGIC FEATURES: The attached site plan shows the location of the slope located between the Leenhouts property and Highway 106 and the general locations of the existing and proposed dwelling features. 3. LOCATIONS OF LOGS OF EXPLORATORY HOLES OR PROBES: Soil probe locations are provided on the attached plan sheets along with depths from the ground's surface to the hardpan layer underlying the site. The slope between the Leenhouts building area and the Highway 106 elevation is modeled as a hardpan soil layer underlying a moderately firm surface soil layer approximately 3 to 4 feet thick. 4. AREA OF PROPOSED DEVELOPMENT&BOUNDARIES OF HAZARDS, BUFFERS, AND SETBACKS: The attached site plan shows the locations of existing property improvements(single family residence&detached garage),the location of the existing septic system,the landslide hazard areas (areas containing slopes greater than 40%) as well as the 50-foot wide landslide hazard area buffers required around Landslide Hazard Areas by the County. The major proposed development proposed on the property at this time is the remodeling and addition to the existing residence. File:C.lProjecWLeenhoutslGeo-Rpt 3 of 6 4/26/2010 f ' TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 5. CROSS SECTION WITH PROPOSED GRADE CHANGES: A cross section view is provided in the attached plan sheets. This same cross section was used in modeling the site's stability. No grading or grade changes are required or proposed on the property's steep slope. 6. SLOPE STABILITY ANALYSIS: The steep slope generally descending from southeast to northwest on the property appear stable in their present condition. Back analysis of the standing cut banks in the area provided values in what soil characteristics can be expected from the site's soils and can be used in stability modeling. The steep hillside is modeled as a cemented glacial till layer beneath a moderately firm surface soil layer composed of weathered glacial till approximately 3-feet thick. As indicated earlier in this report, Unified Soil Classification System typing places the soils in a dual symbol category due to its gravel, sand, silt and clay components. A USCS soil classification of GW-SW is used for modeling the site's slopes. The soil mechanical properties used in the stability analysis are based on the shallow soils characterized as having a soil unit weight of 125 lbs/ft, a phi angle of 42°, and a cohesion character of 2001bs/ft2. The deeper cemented till substrate is modeled as having a soil density of 130 lbs/ft3,a phi angle of 42°, and a cohesion character of 4001bs/ft The slope geometry and soil characteristics provide a factor of safety for the site in a static analysis of 2_3 and a dynamic analysis of 1_8, both of which meet the County's minimum safety requirements. 7. RECOMMENDED SETBACKS &DRAINAGE: The existing residence is located southeast of the crest of the northwesterly descending slope on the property and may be considered safe in its present location. The existing residence is located approximately 16+feet away from the crest of the steep slope and an existing concrete patio 8-feet wide extends from the existing house towards the crest of the slope. The dwelling addition is proposed to be located in the approximate footprint of the existing concrete patio,which will provide an approximate 8-foot separation between the dwelling and the top of the Hazard Area. This location may be considered an intrusion of approximately 42'f which stability analysis indicates is a safe location. A hazard area buffer reduction request accompanies this report which requests an intrusion of roughly 45-feet be allowed into the hazard area buffer. Drainage from the present leveled building location sheets to its natural drainage relief generally to the northwest, Highway 106's drainage ditches, and ultimately to Hood Canal. The dwelling addition adds no new imperviousness to the property and the existing drainage regime functions adequately. If remodeling of the dwelling includes the addition of gutters and downspouts,the downspout discharges should be located as far back from the crest of the steep slope as practicable. Splash blocks which disperse downspout discharges would be an acceptable stormwater management feature,but should be located no nearer than 5-feet back from the crest of the steep slope. File:C:IProjectsUenhoutslGeo-Rpt 4 of 6 4/26/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 8. CLEARING, GRADING,AND VEGETATION MANAGEMENT: The currently proposed dwelling remodel and addition will require clearing of the area where the existing patio concrete is,but otherwise no actual site clearing will be required. Trees on the steep slope may be topped or limbed for view enhancement, but the tree stumps and roots should remain and the existing vegetation on the slope should be preserved, or may be replaced with landscape plantings which would provide a root structure for soil stability and erosion resistance. 9. EROSION AND SEDIMENT CONTROL: Inspection of the Soil Survey of Mason County found the site to be located in an area with an Alderwood soil type (A,,),which is identified in the County's Critical Resource Ordinance as an erodible soilsusceptible and to severe erosion when disturbed. As roe located over a property rtY potentially erodible soil, Mason County requires the development of an Erosion and Sediment(E&S) Control Plan. An E&S Plan sheet is included in the appendix which includes minimum E&S measures which need to be employed when land disturbing activities are undertaken during the property's development activities. Any silt or mud escaping the Leenhouts property onto neighboring properties could be identified as a violation of Mason County's Stormwater Management regulations. All measures necessary to remove mud&turbidity from construction runoff should be implemented and maintained until the completed construction area has become permanently stabilized with vegetation or gravel. Recommended silt fence installation locations are indicated on the Erosion and Sediment(E&S) Control Plan sheet prepared for the proposed land disturbing activities. A permanent access to the existingresidence and existing garage already exist and are stable in their resent condition. The gg g Y p proposed work is expected to be performed during favorable weather during the dry season of 2010. 10. ON-SITE AND OFF-SITE IMPACTS: The proposed remodel and addition to the existing residential features on the Leenhouts property are not expected to result in either any onsite or offsite detrimental impacts. 11. SPECIFICATIONS OF FINAL DEVELOPMENT: Upon completion of the proposed dwelling improvement(s), any denuded soils should be seeded with grass and covered with a 3-inch or thicker layer of straw or hay to protect the bare soil from potential erosion impacts until permanent vegetation is able to perform that function. 12. RECOMMENDATIONS FOR THE PREPARATION OF STRUCTURAL MITIGATION OR DETAILS OF OTHER PROPOSED MITIGATION: Modeling of the slopes in the area of the proposed work indicate that the hillsides located on the Leenhouts property are stable,requiring no structural measures or mitigation. Footings constructed adjacent(>5' back) from the crest of the steep slope should bear on the undisturbed glacial till layer underlying the site. File:C.TrojectslLeenhoutslGeo-Rpt 5 of 6 4/26/2010 r TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 13. SITE PLAN WITH THE LOCATION OF EXISTING AND PROPOSED DEVELOPMENT ON THE SITE: A site plan is attached as an appendix to this report and is hereby made a part of this report along with the cross section view of the property,the stability analysis printout,and an Erosion and Sediment Control Plan Sheet. Summary& Conclusions: The Leenhouts' property and proposed land disturbing activities,though located in an area designated in Mason County's Critical Resource Ordinance as a Landslide Hazard, does not contain any landslide hazard features that cannot be overcome or mitigated. Please feel free to contact me if there are any questions or concerns regarding this report or my findings. Sincerely, 1' �,of WA t Alan A. Tahja, P.E. w � �P 3D784� w� �ECISTER�9 ' Attached: Geotechnical Report Checklist �SSIONAL S�' Hazard Area Reduction Request Plan Views, Cross Section Sheet and E&S Plan Sheet GALENATM Stability Analysis Printout File:C:IProjectslLeenhouts)Geo-Rpt 6 of 6 4/26/2010 Rev# Description Date TAHJA ENGINEERING,INC. SITE PLAN Alan Tahja,P.E. Michael&Becky Leenhouts Leenhouts PO Box 235 3016 Niagara A Hoodsport, WA 98548 Bellingham, WA 98226-4216 1 of 4 Mason Co.Prcl No.: 32236-51-00011 (360)877-9512 (360)739-5537 (cell) o- 0 8 � \ � o \\\ II \ U N 9of \ \ 4 z � O , Q \ J � ¢ n -0 C mW a kn ¢ o Y \ N � Rev# Description Date TAHJA ENGINEERING,INC. SITE PLAN P4 A Alan Tahja,P.E. Michael&Becky Leenhouts Leenhouts PO Box 235 3016 Niagara St. AM Hoodsport WA 98548 Bellingham, WA 98226-4216 2 of 4 Mason Co.Prcl No.: 32236-51-00011 (360)877-9512 (360)739-5537 (cell) j o •" IN L a 8 /` a) �.a € y � N� X �_ _ o � � j F \ z --g v C� a � 0 c bD o [c1 �= b = Lon E \ I y w z = \ \ o 0 \ a IQO e o ' N O U \ *a 00 o A .01 CID \ \ oZ \\ \ 0 \ Rev# Description Date TAHJA ENGINEERING,INC. CROSS SECTION A-A Pi4 mb Alan Tahja,P.E. Michael&Becky Leenhouts Leenhouts PO Box 235 3016 Niagara St. HoodspoA WA 98548 Bellingham, WA 98226-4216 3 of 4 Mason Co.Prcl No.: 32236-51-00011 (360)877-9512 (360)739-5537 (cell) CO 0 I I � auul pea8 al99ad H Q c ---�— v: --- --- --- --- --- --- ar SPA .a E Az- I I 40 T FC --- --- --- --- .R � 1 U lu R U L z h C) --- ---�---� OC AVE 901 AMH ch I I I I I I luawaned JO aONI ————— augialua�A— auglalu3D AMH JWMAed 3o a3PH i AVE 901 AMH N Erosion & Sedime Control: I.Install silt fences befor commencing land disturbing activitie / near house&SR 106. 2.Cover un-worked denuded s 'Is with a 3"+thick layer of str or hay as soon as practical(7 day ' it summer,2 day limit inter). / Z 3.Seeded completed work areas wit rass seed and co v straw Maintain temporary E&S measures til site beco s rman s bilized with grass&native vegetatio Its, HOOD CANAL 'lt Fe e / N W E Af \ 0 1 30 50 00 V k �, / Exist. / // ' �• Drainfield / E ' tin g arage / C) `�S-„ / F WA N a \ � Cyr�'�'�s�'C 3TERF' `SIGNAL Property Line* imension Provided by SEL DESIGN,LTD. bi qqqmq TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Leenhouts X-Section A-A Static Stability Analysis GALENA v«a.&o, 160 140 A. 120 pF WASFj Phreatic Surface(saturated surface soils) - 80 -3'Tltick Weathered Surfers Soil Layer., I 784 w4 60 .....�...._.....- S E TR�9 'w Leenhouts Dwelling �`sSIONAL 40 Cemented Glacial Till substrate i 20- HWY 106 /s Analysis: 1 Multiple Stability Analysis 0 Method: Bishop Simplified Surface: Circular -20 Results Critical(minimum) -40 Factor of Safety: 2.26 0 50 100 150 200 250 300 Edited:25 Apr 2010 ProwaW 25 Alx 2010 Proiect: Leenhouts Pebble Beach Residence Static F& C:\Documents and Settings\Owner\My Documents\Projects\Leenhouts\Galena Files\Leenhouts Static 1.gmf Tahja Engineering,Inc. Galena 5.01 Analysis Results Licensee: Tahja Engineering, Inc. DATA: Analysis 1 - Static Material Properties (2 materials) ------------------- Material: 1 (Mohr-Coulomb Isotropic) - Weathered Till Surface Soil Layer Cohesion Phi UnitWeight Ru 200.00 34.0 125.00 1.10 Material: 2 (Mohr-Coulomb Isotropic) - Cemented Glacial Till Layer Cohesion Phi UnitWeight Ru 400.00 34.0 130.00 1. 10 Water Properties ---------------- Unit weight of water: 62.400 Unit weight of water/medium above ground: 62.400 Material Profiles (2 profiles) ----------------- Profile: 1 (2 points) Material beneath: 1 - Weathered Till Surface Soil 0.00 120.00 300.00 120.00 Layer Profile: 2 (10 points) Material beneath: 2 - Cemented Glacial rill Layer 68.50 0.00 27.00 18.00 54.00 19. 00 57.00 20.00 81.10 37.50 85.00 39.00 125.30 46.00 175. 10 56.00 220.30 66.00 265.50 76.00 Slope Surface (8 points) ------------- 81. 10 40.00 125.30 0.00 19.00 54.00 20.00 67.50 30. 00 50.00 175.10 60.00 220.30 70.00 265.50 80.00 File:C:IProjectslLeenhouts X-Sec A-A Analysis Printout I of 4 4/2 6/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Phreatic Surface (2 points) ---------------- 0.00 100.00 300.00 100.00 Failure Surface --------------- Initial circular surface for critical search defined by: XL,XR,R Intersects: XL: 46.00 YL: 19.85 XR: 86.00 YR: 41.11 Centre: XC: 61.03 YC: 39.83 Radius: R: 25.00 Variable Restraints ------------------- Parameter descriptor: XL XR R Range of variation: 25.00 25.00 15.00 Trial positions within range: 12 12 12 ------------------------------------------------------------------------------------- RESULTS: Analysis 1 - Static Bishop Simplified Method of Analysis - Circular Failure Surface --------------------------------------------------------------- Critical Failure Circle Search using Multiple Circle Generation Techniques Factor of Safety for initial failure circle approximation: 3.81 There were: 1028 successful analyses from a total of 1729 trial circles 701 analyses terminated due to unacceptable geometry Critical (minimum) Factor of Safety: 2.26 Circle and Results Summary (Lowest 16actor of Safety circles) -------------------------- Circle X-Centre Y-Centre X-Left Y-Left X-Right Y-Right Radius FoS 1 64.57 31.80 51. 68 19. 96 80.32 39.43 17.50 2.261 2 67.80 32.81 53. 95 20.00 84.86 40.85 18.86 2.471 3 68.87 33.75 56.23 21.65 84.86 40.85 17.50 2.530 4 65.14 33.18 51. 68 19. 96 82.59 40.34 18.86 2.531 5 61.21 29.25 44 .86 19.83 78.05 37.75 18.86 2.583 6 65.73 30.84 47.14 19.87 84 .86 40.85 21.59 2.617 7 59.77 28.99 44.86 19.83 75.77 36.08 17.50 2.790 8 63.47 34.68 53. 95 20.00 80.32 39.43 17 .50 2.809 9 62.37 33. 62 49.41 19.91 80.32 39.43 18.86 2.818 10 62. 64 32.09 44 .86 19.83 82.59 40.34 s9 2.856 2111 65.62 34 .61 51.68 19.96 84.86 40.85 20.23 2.873 12 68.14 34.42 53.95 20.00 87.14 41.37 20.23 2.889 13 71.18 32.07 51. 68 19.96 91. 68 42.39 22.95 2. 913 49.41 19.91 7805 37.75 14 61.27 32.79 . 17.50 2.956 34 .76 49.41 19.91 82.59 40.34 15 63.15 20.23 2.959 20.00 82.59 40.34 16 64.29 35.78 53.95 18.86 2.963 File:C:IProjects\Leenhouts X-Sec A-A Analysis Printout 2 of 4 4/26/2010 TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Leenhouts X-Section A-A Static Stability Analysis GALENA v ryon5,01 160 o.1so 140 120 P^ceatic Surface(saturated surface soils) F'p 100 ___.._----------_-------------_..__....__..-.�... so -3'Thick Weathered Smlace Soil Layer., Co Laenlawta Dwelling 40 Cemented Glacial Till Suhatrate HWY 106 20 Analysis: 1 Multiple Stability Analysis 0 Method: Bishop Simplified Surface: Circular -20 Results Critical(minimum) Factor of Safety. 1.84 -40 0 50 100 150 200 250 300 Edted:25 Apr 2010 Prateaaa l 25 Apr 3010 Project Leenhouts Pebble Beach Residence Dynamic Ei(a: C\Documents and Settings\Owner%My Documents\Projeas\Leenhouts\Galena Files\Leenhouts Dynamic 1.gmf Tahja Engineering,Inc. Galena 5.01 Analysis Results Licensee: Tahja Engineering, Inc. DATA: Analysis 1 - Dynamic Material Properties (2 materials) ------------------- Material: 1 (Mohr-Coulomb Isotropic) - Weathered Till Surface Soil Layer Cohesion Phi UnitWeight Ru 200.00 34 .0 125.00 1.10 Material: 2 (Mohr-Coulomb Isotropic) - Cemented Glacial Till Layer Cohesion Phi UnitWeight Ru 400.00 34.0 130.00 1.10 Water Properties ---------------- Unit weight of water: 62.400 Unit weight of water/medium above ground: 62.400 Material Profiles (2 profiles) ----------------- Profile: 1 (2 points) Material beneath: 1 - Weathered Till Surface Soil Layer 0.00 120.00 300.00 120.00 Profile: 2 (10 points) Material beneath: 2 - Cemented Glacial Till Layer 0.00 18.00 54.00 19.00 57.00 20.00 68.50 27.00 81.10 37.50 85.00 39.00 125.30 46.00 175. 10 56.00 220.30 66.00 265.50 76.00 Slope Surface (8 points) ------------- 0.00 19.00 54.00 20.00 67.50 30a00 81. 10 40.00 125.30 50.00 175.10 60.00 220.30 70. 00 265.50 80.ao File:C:IProjectslLeenhouts X-Sec A-A Analysis Printout 3 of 4 4/26/2010 Oppol- TAHJA ENGINEERING, Inc. PO Box 235, Hoodsport, WA 98548 (360) 877-9512 Phreatic Surface (2 points) ---- 0.00 100.00 300.00 100.00 Failure Surface --------------- Initial circular surface for critical search defined by: XL,XR,R Intersects: XL: 46.00 YL: 19.85 XR: 86.00 YR: 41.11 Centre: XC: 61.03 YC: 39.83 Radius: R: 25.00 Earthquake Force ---------------- Pseudo-static earthquake (seismic) coefficient: 0.150 Variable Restraints ------------------- Parameter descriptor: XL XR R Range of variation: 25.00 25.00 15.00 Trial positions within range: 12 12 12 --------------------------------------------------------------------------- RESULTS: Analysis 1 - Dynamic Bishop Simplified Method of Analysis - Circular Failure Surface --------------------------------------------------------------- Critical Failure Circle Search using Multiple Circle Generation Techniques Factor of Safety for initial failure circle approximation: 2.54 There were: 1028 successful analyses from a total of 1729 trial circles 701 analyses terminated due to unacceptable geometry Critical (minimum) Factor of Safety: 1.84 Circle and Results Summary (Lowest 15 Factor of Safety circles) -------------------------- Circle X-Centre Y-Centre X-Left Y-Left X-Right Y-Right Radius FoS 1 64 .57 31.80 51. 68 19. 96 80.32 39.43 17.50 1.844 2 67.80 32.81 53.95 20.00 84.86 40.85 18.86 1. 983 3 65. 14 33.18 51. 68 19.96 82.59 40.34 18.86 1.992 4 68.87 33.75 56.23 21.65 84.86 40.85 17.50 2.022 5 61.21 29.25 44.86 19.83 78.05 37.75 18.86 2.099 6 65.73 30.84 47. 14 19.87 84.86 40.85 21.59 2.113 7 63.47 34 . 68 53.95 20.00 80.32 39.43 17.50 2.115 8 62.37 33. 62 49.41 19. 91 80.32 39.43 18.86 2.143 9 62.57 51.34 53. 95 20.00 93.95 42. 91 32.50 2. 156 10 64.56 50.72 53. 95 20.00 96.23 43.42 32.50 2. 166 11 65.62 34.61 51. 68 19.96 84.86 40.85 20.23 2.167 12 60.58 51.82 53. 95 20.00 91. 68 42.39 32.50 2.172 13 62.39 5o.64 51.68 19.96 93. 95 42.91 32.50 p.Z73 14 63.55 49. 62 53.95 20.00 93. 95 42.91 31.14 2.179 15 61.54 50.20 53.95 20.00 91.68 42.39 31. 14 2.182 File:coiprojectslLeenhouts X--Sec A-A Analysis Printout 4 of 4 4/26/2010 Mason County Review Checklist For a Geotechnical Report Instructions: This checklist is intended to assist Staff in the review of a Geotechnical Report. The Geotechnical Report is reviewed for completeness with respect to the Resource Ordinance. If an item is found to be not applicable, the Report should explain the basis for the conclusion. The Report is also reviewed for clarity and consistency. If the drawings, discussion, or recommendations are not understandable, they should be clarified. If they do not appear internally consistent or consistent with the application or observations on site, this needs to be corrected or explained. If resolution is not achieved with the author, staff should refer the case to the Planning Manager or Director. Applicant's Name: 1 wP hjofs Permit# U �� `V ) Parcel # 7Z36 S I✓v OZ C Date(s)of Mlihentto(s) revie l bw 2-0 to (1) (a)A discu sion of general geologic conditions in the vicinity of the proposed development, OK?__V Comment: (b) Adis ssion of specific soil types OK? Comment: (c) A discussion of ground.water conditions OK? V Comment: (d) A dis ussion of the upslope geomorphology OK?L Comment: (e) A discussion of the location of upland waterbodies and wetlands OK? V Comment: (f) A discussion of history of landslide activity in the activity in the vicinity, as available in the refer ced maps and records OK? Comment: (2) A site plan y�hich identifies he import n�pme and geologic features. OK? ✓ C m m oent: Pte� (3) Locations d logs of a lorato oles or grebes. OK?Comment: (4) The area of the proposed de elopment, the boundaries of the hazard, and associated buffers and setbacks Pall be delineated (to t s, an toe)on a geologic map of the site. OK? I Z Comment: l 7/ (5) A minimum of one cross section at a scale which adequately depicts the subsurface profile, and which incorporates the details f ropos� es. OK? Comment: (6) A description and results of Alope stability analyses performed for both static and seismic loading conditions.Analysis should examine worst case failures. The analysis should include the Simplified B' hop's Method of Circles. The minimum static safety factor is 1.5, the minimum seismic s ety factor is 1.1. and the quasi-static analysis coeffients should be a value of 0.15. OK? Comment: (7) (a)Apprc iate restrictions on placement of drainage features OK?___V Comment: (b) Appropriate restrictions on placement of septic drain fields OK? Comment: (c) Appropriate restrictions on placement of compacted fills and footings OK? Comment: (d) Recommended buffers from the landslide hazard areas shoreline bluffs and the tops of other slopes on the property. Page 1 of 2 Form Effective June 2008 OK?__ ,--Comment.- (e) Recommen ed setbacks from the landslide hazard areas shoreline bluffs and the tops of other sl es on the property. OK? Comment: (8) Recommendations for the prep a on of a detaile clearing and grading pla �ich specifically identifies vegetation to be removed, a schedule for vegetation removal and replanting, and the method of vv etation removal. OK? ✓ Comment: (9) Recommendations for the preparation of a detailed temporary erosion control plan which identifies the specific mitigating measures to be implemented during construction to protect the slope from�rosion, landslides and harmful constr ction methods . OK? ✓ Comment: C� 5 (10) An analysis both on-site and off-site impac s of the proposed development. OK? Comment: (11) Specifications of final development conditions such as, vegetative management, drainage, erosion cont and buffer widths. OK? Comment: (12) Recommendations for the preparation of structural mitigation or details of other proposed mitigation. OK? Comment: (13) A site map drawn to scale showing the property boundaries, scale, north arrow, and the location and nature existing and proposed development on the site. OK? Comment: - - E�g_"e- Are the Documents signed and stamped? Type and #of License: ,/ 1- 36 Z 8 1( If not approved, what is the next action/recommendation for further action? L Reviewed by , on Time spent in review: SECOND REVIEW/UPDATE: Reviewed by , on Time spent in second review: THIRD REVIEW/UPDATE: Reviewed by , on Time spent in third review: Disclaimer: Mason County does not certify the quality of the work done in this Geological Assessment Page 2 of 2 Form Effective June 2008 Mason County Review Checklist 1` For a Geotechnical Report Instructions: This checklist is intended to assist Staff in the review of a Geotechnical Report. The Geotechnical Report is reviewed for completeness with respect to the Resource Ordinance. If an item is found to be not applicable, the Report should explain the basis for the conclusion. The Report is also reviewed for clarity and consistency. If the drawings, discussion, or recommendations are not understandable, they should be clarified. If they do not appear internally consistent or consistent with the application or observations on site, this needs to be corrected or explained. If resolution is not achieved with the author, staff should refer the case to the Planning Manager or Director. Applicant's Name: La6w,hiry Permit#_otlb �6a Parcel # �7-?�6 S� s Date(s) of tt�e-Docdrri'e t�s re 'W� (1) (a)A discu pion of general geologic conditions in the vicinity of the proposed development, OK?I/Comment: (b) A disc ssion of specific soil types OK? Comment: (c) A disc ssion of ground,water conditions OK? V Comment: - (d) A di s ussion of the upslope geomorphology OK? Comment: (e) A discussion of the location of upland waterbodies and wetlands OK? V Comment: (f) A discussion of history of landslide activity in the activity in the vicinity, as available in the refergmed maps and records OK? V Comment: (2) A site plan�ich identifies he important developmeand geologic features. OK? ✓ Comment: (3) Locations d logs of a lorato oles or pcpbes. OK?Comment: G (4) The area of the proposed de elopment, the boundaries of the hazard, and associated buffers and setbacks all be delineated(to , t , s, an toe,)on a geologic map of the site. OK?__. Comment: tql/ (5) A minimum of one cross section at a scale which adequately depicts the subsurface profile, and which incorporates the details f ropos� �� es. OK? IZ Comment: (6) A description and results of Alope stability analyses performed for both static and seismic loading conditions.Analysis should examine worst case failures. The analysis should include the Simplified t3' hop's Method of Circles. The minimum static safety factor is 1.5, the minimum seismic s ety factor is 1.1. and the quasi-static analysis coeffients should be a value of 0.15. OK? Comment: (7) (a)AppropFiate restrictions on placement of drainage features OK?__V Comment: (b) Appropriate restrictions on placement of septic drain fields OK? Comment: (c) Approp late restrictions on placement of compacted fills and footings OK? Comment: (d) Recommended buffers from the landslide hazard areas shoreline bluffs and the tops of other slopes on the property. Page 1 of 2 Form Effective June 2008 OK?_'ZComment: (e) Recommen ed setbacks from the landslide hazard areas shoreline bluffs and the tops of other sl es on the ro ert P P Y OK? Comment: �i s (8) Recommendations for the prep a on of a detaileb clearing and grading plan Aich specifically identifies vegetation to be removed, a schedule for vegetation removal and replanting, and the method of vegetation removal. OK? ✓ Comment: (9) Recommendations for the preparation of a detailed temporary erosion control plan which identifies the specific mitigating measures to be implemented during construction to protect the slope from osion, landslides and harmful constr ction m hods. OK? Comment: (10) An analysis both on-site and off-site impac s of the proposed development. OK? Comment: (11) Specifications of final development conditions such as, vegetative management, drainage, erosion conter and buffer widths. OK? Comment: (12) Recommendations for the preparation of structural mitigation or details of other proposed mitigation. OK? V Comment: (13) A site map drawn to scale showing the property boundaries, scale, north arrow, and the location and nature existing and proposed development on the site. OK? Comment: Are the Documents signed and stamped? Type and (� YP ��f License: .� �� If not approved, what is the next action/recommendation for further action? g ` � l Reviewed by on Time spent in review: SECOND REVIEW/UPDATE: Reviewed by on Time spent in second review: THIRD REVIEW/UPDATE: Reviewed by , on Time spent in third review: Disclaimer: Mason County does not certify the quality of the work done in this Geological Assessment Page 2 of 2 Form Effective June 2008 I