s RESIDENTIAL BUILDING PERMIT
BLD2017-00650
OWNER: CEDARLAND FOREST RESOURCES RECEIVED: 7/7/2017
CONTRACTOR: LICENSE: EXP: ISSUED: 9/13/2017
SITE ADDRESS: 381 E LAKESHORE DR ALLYN EXPIRES: 4/17/2018
PARCEL NUMBER: 122205400017
LEGAL DESCRIPTION: LAKE LAN D VILLAGE 5 TRACT 17
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW SFR: 1670 sq ft W/ATTACHED GARAGE SITE LOCATED AT THE CORNER OF E LAKESHORE DR AND E MOUNTAIN
VIEW DR
General Information Construction&Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size: Deck: 0
Type of Work: NEW Fire Dist.: 5 No.of Stories: Occ. Load: Building:1,670 Garage-Attached 731
Valuation: $ 225,641.23 Building Height: Occ. Status: Seasonal Basement:
Manufactured Home Information I Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: W 120.0 Ft. Shoreline: Ft. WaterBody:
Rear: N 20.0 Ft. Slope: Ft. SEPA?: Unkn
Model: Width: Ft. Shoreline Desig.: OWttApplicable
Side 1: E 10.0 Ft.
Year: Serial No.: Side 2: S ! 10.0 Ft. Comp. Plan Desig.: Urban Growth Area
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Water Closets (Toilets) 2 Furnace<100K 1 Plan Check Fee JBN 717/2017 $ 1,104.58 S2201700000001
Lavatories 3 Propane Tank 1 EH Plan Review JBN 7/7/2017 $210.00 S2201700000001
Bath Tubs 2 Gas Outlets 4 Planning Review Fee JBN 7/7/2017 $205.00 S2201700000001
Showers 2 Propane Stove 1 Address Fee JBN 7/7/2017 $ 173.50 S2201700000001
Water Heaters 1 Exhaust Hood 1 Building State Fee MPB 8/24/2017 $4.50 S3201700000001
Clothes Washer 1 Dryer Vent 1 Building Permit Fee MPB 8/24/2017 $ 1,699.35 S3201700000001
Kitchen Sink 1 Ventilation Fan 3 Mechanical Base Fee MPB 8/24/2017 $28.50 S3201700000001
Dishwasher 1 Plumbing Permit Fee MPB 8/24/2017 $ 119.30 S3201700000001
Hosebibs 2 Plumbing Base Fee MPB 8/24/2017 $24.70 S3201700000001
Mechanical Permit Fee MPB 8/24/2017 $219.70 S3 2 01 7 0000 0001
Total $3,789.13
I
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 1 of 8
Inspection Line (360)427-7262
PQVN Cou , MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County
615 W Alder St
Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT BLD2017-00650
OWNER: CEDARLAND FOREST RESOURCES RECEIVED: 7/7/2017
CONTRACTOR: LICENSE: EXP: ISSUED: 9/13/2017
SITE ADDRESS: 381 E LAKESHORE DR ALLYN EXPIRES: 3/13/2018
PARCEL NUMBER: 122205400017
LEGAL DESCRIPTION: LAKELAND VILLAGE 5 TRACT 17
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW SFR: 1670 sq ft W/ATTACHED GARAGE SITE LOCATED AT THE CORNER OF E LAKESHORE DR AND E MOUNTAIN
VIEW DR
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: SF Insp. Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size: Deck: 240
Type of Work: NEW Fire Dist.: 5 No. of Stories: Occ. Load: Building:1,670 Garage-Attached 731
Valuation: $ 225,641.23 Building Height: Occ. Status: Seasonal Basement:
Manufactured Home Information Setback Information Shoreline& Planning Information
Make: Length: Ft. (9 Front: W� Water Body:
Q Ft. Shoreline: Ft. SEPA :
Model: Width: Ft. FDA}� N ' Ft. Slope: Ft. Shoreline Desig.:
Side 1: 5 to Ft.
Year: Serial No.: Side 2: V tOl Ft. Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Water Closets (Toilets) 2 Furnace<100K 1 Plan Check Fee JBN 7/7/2017 $ 1,104.58 S2201700000001
Lavatories 3 Propane Tank 1 EH Plan Review JBN 7/7/2017 $210.00 S2201700000001
Bath Tubs 2 Gas Outlets 4 Planning Review Fee JBN 7/7/2017 $205.00 S2201700000001
Showers 2 Propane Stove 1 Address Fee JBN 7/7/2017 $ 173.50 S2201700000001
Water Heaters 1 Exhaust Hood 1 Building State Fee MPB 8/24/2017 $4.50 S320170000000(
Clothes Washer 1 Dryer Vent 1 Building Permit Fee MPB 8/24/2017 $ 1,699.35 S320170000000(
Kitchen Sink 1 Ventilation Fan 3 Mechanical Base Fee MPB 8/24/2017 $28.50 S320170000000(
Dishwasher 1 Plumbing Permit Fee MPB 8/24/2017 $ 119.30 S3201700000001
Hosebibs 2 Plumbing Base Fee MPB 8/24/2017 $24.70 S3201700000001
Mechanical Permit Fee MPB 8/24/2017 $219.70 S3201700000001
Total $ 3,789.13
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 1 of 8
CASE NOTES FOR
BLD2017-00650
CONDITIONS FOR
BLD2017-00650
1) Prior to final approval, all upland areas disturbed or ne I cr ated by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X L�
2) Approve a dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
3) Xpplica a knowledges that the structure is only permitted for a use consistent with the current zoning of the parcel. Zoning is Allyn UGA- R-1 P.
4) The site plans indicates a sub-standard front yard building setback of approximately 17 ft. (closest part of the structure measured to the road).
The site plan shall be amended to reflect a 25 ft front yard building setback or a 20 ft front yard building setback for garages with roll-up doors.
To accommodate for the revised front yard building setback, the house shall be shifted towards the rear property line, as the rear yard building
setback can be 20 ft. All portions of the structure shall conform to the front yard building setback as stated above. NOTE: 2 ft roof overhangs
into the pres a setbacks are allowed. Proponet shall acknowledge this amendment by initializing site plan on record prior to permit
issuance. X
5) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800 7 f)982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X (�
6) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be ranted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Dep t prior to any further inspections being performed or approvals granted.
X
7) Owner/ nt is sponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
8) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removalpproved documents will result in failure of required building inspections.
X off
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 2 of 8
9) THE QjD�ION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL.
10) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Buildi rtm nt prior to any further inspections being performed or approvals granted.
X TV—,
11) Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine -4C, Window (Max U-Factor):0.30, Skylight(Max
U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38,
and Slab Insulation R-10.
In addition the following credits from WSEC table R406.2 shall be completed as follows:
1A: EFFICIENT BUILDING ENVELOPE
Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab
or
Compliance based on Section R402.1.4: Reduce the Total UA by 5%.
3A: HIGH EFFICIENCY HVAC EQUIPMENT
Gas, propane or oil-fired furnace with minimum AFUE of 94%, or Gas, propane or oiled-fired boiler with minimum AFUE of 92%
5A: EFFICIENT WATER HEATING
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or
less.
5C: EFFICIENT WATER HEATING
Water heating system shall include one of the following: Gas, propane or oil water heater with a minimum EF of 0.91
or
Solar water heating supplementing a minimum standard water heater. Solar water
heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation (SRCC)Annual
Performance of OG-300
Certified Solar Water Heating Systems
or
Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water
Heater
X
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 3 of 8
12) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution
panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall
and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there
is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of
heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage
results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested
with a blower door in accordanve with IECC/.WSEC Section R402.4.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is
not required for additions less than 750 square feet. Reference IECC/WSEC R401.3.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are available in %or'/z sheets. The
Maso County Permit Center will also have some available.
X
13) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section
R404.1.
X a VJ..Z
14) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85
MPH.
X R&Z
15) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the
manufacturer's installation instructions.
A drip edge shall) be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5)
X C�J`
16) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wis to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contract now dging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 4 of 8
17) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation.
In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000.
X
18) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered.
A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations.
B. Septic tank(s) requires 5ft setback from all footing/foundations.
C. Nc�p�yr�dation drains within 30ft, down gradient of drainfield/reserve area.
X l7J �
19) A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2
and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule
shown on sheet S3 and D1 designate wall type Portal Frame with fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections,
the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in
Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building
Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and
submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project.
X L
20) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC
Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances),
repair , o additions requiring a permit occur, or when one or more sleeping rooms are added or created.
X
21) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
theret If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be
charg qnd shall be collected by the Building Department prior to any further inspections being performed or approvals granted.
X
22) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State f Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
perm t ca � n.
X
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 5 of 8
23) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the
IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC
systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be
available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts
shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets
equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance
to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are
available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct
tightnW testing is not required if the air handler and all ducts are located within the heated space.
X
24) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been
identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or
opera ha obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
X
25) The placement of buildings and structures on or adjacent to slopes steeper than one unit vertical in three units horizontal (33.3% slopes) shall conform to
the International Residential Code Section R403.].I for descending or ascending slopes.
Alternate setbacks may be approved subject to approval of the building official based upon the investigation and recommendations of a qualified engineer
licensed in the State of Washington. Such an investigation shall include consideration of material, height of slope, slope gradient, load intensity, and
erosiW characteristics of slope material.
X
26) Proposed structure or portions thereof, mus n in a ' separation distance between adjacent structures. Separation is measured from furthest
projection to furthest projection. X
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 6 of 8
27) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordin for regulation, must be reviewed and approved by Mason County prior to construction.
X
28) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENTAND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with he international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Ins e r shall be made prior to requesting additional inspections.
X
29) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled
on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system
air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane
tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public
way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be
the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective
bolla ust be installed.
X
30) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks
between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures,
compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements
shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as
specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be
installe
X 6L:�:
31) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must
X meet t Q i allation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks.
32) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the
time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall
not be d until
�a final inspection has been performed and approved by a Mason County building inspector.
X I �J
33) Owner/applicant must obtain a seperate per ' T th acement of any size propane tank serving a fixed appliance within a dwelling structure or unit
prior to the placement of the tank. X
34) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to
Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams,
wetlands, slopes, etc.) If you think such fVc�
n or nearby your property, please contact the Planning Department so that exact setback
requirements can be determined. X
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 7 of 8
35) All property lines shall be clearly identified at the time of foundation inspection. X 12�
36) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Maso o ty ordinances and building regulations.
X
v s
37) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
(older y vp prevented action from being taken. No more than one extension may be granted.
38) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connec , and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X
39) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approv "' to ensure these structures are shown and meet the setback conditions listed.
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s) for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PER T APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. qJ
--7
t
Signature 0
amdl
(1Date
v In OWNER - REPRESENTATIVE - CONTRACTOR
Print Nam (Circle one to indicate)
BLD2017-00650 Please refer to the following pages for conditions of this permit. Page 8 of 8
2,01 T 6)061�5-0
_ly.':,..r �1
e
C, JUL 0 7 20V
O e n
615 W. Alder Street m a A
FS ,� 00 1� 0
a
AN G
MASON CO*T11 B
SITE PLAN
E SITE
C-(,
CHANGESS ROYAL _§Re
By
OS�ro 0 '�
(� 2� rDA}'��� 0
c C) -
ti
SED
pT
Sig
3'
1 4p pp `-,I
Z cn cn
cn
z" I N(51
c �
'"Ile PLANNING:
a` o t;, 7►�-� --�` t Al SETBACKS ARE MEAS RED
30 FROM THE FURTHEST
Q m `� ROJECTION OF THE BUI . ING
c�
0
SITE PLAN MAP FGALAND SURVEY.FNG, PLLC
�,BEQi FESSIONAL LAND SURVEYOR
� ...o� WAS FOR E AGATE RD. - P.O. BOX 245
, WA 98584 - (350) 426-4172
CEDA,RLAND FOREST RESOURCES LLC
1 N THE DA TEQ6/31/2017 fOB N0: 3955
0A" 28237 Jy SE1 f4 SE114 SCALE: i L�ICH = 50' HEET.1 OF 1
o . CHE
NAL L&10) SEC 19, F22N, R1NJ, W1�.
SGB ILE N0: 3955_CFR.dwg
+ 41
Page 1 of 1
Joshua Luck-381 E Lakeshore Dr Permit#BLD 2017-00650
From: Joe Cedarland<joe@cedarlandforestresources.com>
To: Joshua Luck<jluck@co.mason.wa.us>
Date: 10/19/2017 8:25 AM
Subject: 381 E Lakeshore Dr Permit#BLD 2017-00650
Hi Josh,
Per our conservation yesterday we will be removing the rear covered porch from the plan at 381 E
Lakeshore Dr Permit#BLD 2017-00650,I will cross it off the approved plans onsite and initial and date
the change.
Best Regards,
Joe
Joseph T. Cedarland
Managing Partner
Cedarland Forest Resources,LLC
253-208-8136
i oena.cedarlandforestresources.com
www.cedarlandforestresources.com
file:///C:/Users/Jluck/AppData/Local/Temp/XPgrpwise/59E8616AMasonmail 1001616C 7... 10/19/2017
P1,10-ffiI /- GYJ62�
MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST
Owner's Name: Date: 4q o Project description: �" w 5K,
Documents: BUILDING RECEIVED
Building Permit Application Completed. JUL U 7 2017
Mechanical/Plumbing Application Completed.
✓tanning Intake Checklist Completed. 615 W. Alder Street
Site plan includes: Allowable building area, roof overhangs, decks, etc.
Fire Apparatus &Access Road info required? Yes
Stormwater Checklist Completed.
Energy Code Application Form - O Electric wall heater O Electric central furnace ® LPG Furnaces
O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type )
O Ductless Heat Pump O Other: Specify:
Construction Plans:
✓ Sets ( 2 full size sets engineered calculatio s & 1 reduced sized set 11X17 min.(no calculation needed )
Plans Legible _Recognized Scale V Elevation Views ✓Cross Section P`d Z
Foundation Plan �Roof Framing Plan c/Floor Plan —Use of rooms labeled (all floors)
Floor Framing Plan-all floor levels including loft, crawlspace, etc.
Deck Framing Plan including covered porch, carports
Plan Details: (Jn n
✓ Roof framing details, truss lay-out may be needed (Hip and girder location shown) " I' "y C`° )--cAm.
_✓Wall Framing - Does bearing-wall height exceed 10'? (Engi Bring maybe required)
Floor framing: Floor joists (size &spacing): < Floor beams: J�l0
✓Window headers. Typical header: X ME L Garage header: �-f�C Z DF el z—
Foundation: footing size, reinforcement X o2 "
Concrete Walls- Does Concrete Wall Height Exceed 8'? (Engineering may be required, see details)
Landings at all exits? Less than 30"above grade'/ N (must be shown on site plan)
Water Heater: Location: =�rG� Type:
----Heated By Furnace- Location of Furnace Fuel type:
A�Fireplace/Stove Information Shown -Fuel Type? Location(s):
✓' Window Sizes Marked on Plans.
_ Braced wall panels (shear walls) MUST be marked/indicated on plans.
_,,�ngineered<:Y No Snow load: Seismic:(15F) Design Code: �D1 Are plans stamped (�
Manufactured Homes:
Floor Plans (rooms &areas must be labeled)
Founda i n Type:
ANSI/ nufacture meth d E i eered footing/foun io Basement
Decks`: min. I dings required at each a (must be shown on lot Ian)
"Covered decks and/or any decks greater than a 4'x4' (that exceed 30"from grade) requires a permit and
construction plans.
COMMENTS:
Intake review(initia Date: 7 00
//7
H:\permit tech building checklist2015.doc Revised 8.5.2016
If any of the items listed below are either indicated or missing within the construction
documents; the plans must be engineered or returned to the applicant for resolution.
ENGINEERING REQUIRED:
Braced wall panels/brace wall lines are not marked on plans (R602.10)
Amount and location of bracing does not meet minimum required in Table R602.10.1
DESIGN CRITERIA:
All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans.
Wind 85 MPH, Exposure B (unless proven otherwise). Seismic Zone: D2, Snow psf.
IRREGULAR BUILDINGS R301.2.2.2.5 Irregular portions of structures shall be designed in accordance with accepted
engineering practice. A portion of a building shall be considered to be irregular when one or more of the following
conditions occur:
1) Exterior shear wall or braced wall line are not in one plane vertically from the foundation to the uppermost
story in which they are required. See exceptions.
2) Roof or floor is not laterally supported by shear walls or brace walls lines on all edges.
3) Portion of roof or floor extend more than 6 ft. beyond the braced wall line.
4) End of BWP extends more than 1 ft. over an opening more than 8 ft in width below.
5) Opening in a floor or roof exceed the lesser of 12 ft. or 5D% of the least floor or roof dimension.
6) Portions of floor level are offset vertically
7) Shear wall lines do not occur in two perpendicular directions.
8) If a story above grade includes masonry or concrete construction*When this applies the entire story shall be
designed. In accordance with accepted engineering practice. *(exception: fireplaces, chimneys, and veneer as
permitted by the code).
***Applicant must take plans to a design professional to address items indicated above***
Notes/Comments for design professional:
H:\permit tech building checklist2015.doc Revised 8.5.2016
Nam Parcel# 1 )_A)U 5g000 _1 BLD#
Mason County BUILDING
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
httn//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) > The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
Mail: P 0 Box 1850, Shelton WA 98584
Physical:415 N 6th St, Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved RECE �'V ED
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352 JUL 0 7 2017
Mail:P 0 Box 1666,Shelton WA 98584
Physical:426 W Cedar St, Shelton WA 98584 615 W. Alder Street
A condition will be added to the building permit that states,in part,that all conditions the Stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provid ccurate and employees of Mason County are granted access to the above-
described property for re ' 9d inspecti may be required.
X Owner/Agent/Contractor(circle one)Date:
Page 2 of 2
�Narn Parcel#l d1)Q BLD#
I V R-E JO
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area All dimensions in feet
Buildings X
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example.-
eaves/gutters)
X =
Driveways X
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X
Any paved, gravel
X = or packed area per definition
above table
X =
Others X
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area(sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Owner/Agent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
RECEIVED '13Lb - C)O(9 5-0
JUL 0 7 2017
615 W. Alder Street
r-
^ .. , ENVIRONMENTALz�
�. HEALTH
co
10,
14
\ m
O O CO ' � C,
ohooCA ^� �T7�
!`c)
c-
rnTi tact A O
m
/A APp
Z -� L�(,` NSA
n ni O 1n }-�C -�- �f s' AUG 0 4 2017
Z o o 3Q
m � •30 L�
o� Rl I�
�rn �
O
Fri
SITE PLAN MAP AGATE LAND SURVEYING, PLLC
G.BECH PROFESSIONAL LAND SURWYOR
'w� o wAs FOR 2680 E. AGATE RD. - P.O. BOX 246
SHELTON, WA 98584 - (360) 426-4172
CEDARtAND FOREST RESOURCES LLC No:
a I N THE DRA YN BY DATE:06/31/2017 ,1oa 3955
28237 9 'JW SE114 SE114 BECK SCALE: 1 INCH = 50' SHEET-1 Of 1
�'S pECISTE4F ' 4
s � CHECKm BY
j�A'AL LAIR SEC 19, T22N, R1 W, W.M.
SG8 ILE N0: 3955 CFR.dwg
WSEC/Ventilation Code Compliance Application
Submit with heating/cooling system size worksheet (see instructions #4)
Owner: P rc I#: Type of r lect:
265 sn-
Total Sq. Ft. Ist Floor: 2nd floor: Heat asement:
Dof heated area:: , �p I(01 O
Heating System Type: O Electric wall heater O Electric Central Furnace XLPG Furnace
O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump
O Boiler, specify fuel type: O Other: Specify:
Prescriptive Option Table R402.1.1 (see table on previous page)
Compliance Method ❑ Component Performance, R402.1.3 — calculation worksheets required
Must Check one::
❑ Other (Specify):
Check one El
Whole House Ventilation system Whole House Ventilation
Ventilation using exhaust fans&window or wall Integrated with a Forced Air El Other, describe:
fresh air vents (1141507.3.4). If using System (M1507.3.5)
System window vents be sure to order
windows with vents.
Referencing Table R406.2,"Additional Residential Energy Efficiency Requirements," all residential units
must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to
comply. If the table is not attached to this form you can access the table on our website at:
httpi//www.co.mason.wa.us/forms/Community Dev/iecc wsec.pdf
a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor
Additional area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc).
Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor
Efficiency but less than 1,500 sq ft of floor area. Requires 1.5 credits
Requirements b) Medium dwelling units that are not included in (a) above{small dwelling}, OR (c) below
Energy credits {large dwelling} Requires 3.5 credits
required EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5
credits. See page two for description.
c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled
floor area. Requires 4.6 credits
d) Additions less than 500 sq feet. Requires .5 credits
(Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque
doors, lazed-doors that include products with glass and non-glass glazing materials.
Describe Energy Credit Option(s):
Cam_
Using Option number(s): 2 i''�C(GAT BLDG CAV E3,0 PE
4.3
E FF I C I E tT \WATER W T-W G
3
Energy Credits
(2015 WSEC - Table 406,2)
OP DESCRIPTION CREDIT(S)
EFFICIENT BUILDING ENVELOPE 1 a: 0.5
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.28
Floor R-38
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
Corn liance based on Section R402.1.4: Reduce the Total UA by 5%.
1 b EFFICIENT BUILDING ENVELOPE lb: 1.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.25
Wall R-21 plus R-4
Floor R-38
Basement wall R-21 int plus R-5 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
_ Compliance based on Section R402.1.4: Reduce the Total UA by 15%.
`1 c EFFICIENT BUILDING ENVELOPE 1 c: 2.0
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.22
Ceiling and single-rafter or joist-vaulted R-49 advanced
Wood frame wall R-21 int plus R-12 ci
Floor R-38
Basement wall R-21 int plus R-12 ci
Slab on grade R-10 perimeter and under entire slab
Below grade slab R-10 perimeter and under entire slab
or
_ Compliance based on Section R402.1.4: Reduce the Total UA by 30%.
Id EFFICIENT BUILDING ENVELOPE Id: 0.5
Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U=0.24
2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a 0.5
Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per
hour maximum
and
All whole house ventilation requirements as determined by Section M 1507.3 of the
International Residential Code shall be met with a high efficiency fan(maximum 0.35
watts/cfin),not interlocked with the furnace fan.Ventilation systems using a furnace
including an ECM motor are allowed,provided that they are controlled to operate at
low speed in ventilation only mode.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the quali ventilation system.
2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M1507.3 of the
International Residential Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.70.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation system.
5
OPTION DESCRIPTION CREDIT(S)
2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: I.;
Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air
changes per hour maximum
and
All whole house ventilation requirements as determined by Section M1507.3 of the
International Residential Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery efficiency of 0.85.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum tested building air leakage and shall
show the heat recovery ventilation system.
HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0
Gas,propane or oil-fired furnace with minimum AFUE of 94°/y or
Gas,propane or oiled-fired boiler with minimum AFUE of 92%
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency.
3b b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0
Air-source heat pump with minimum HSPF of 9.0
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency.
3Cb HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5
Closed-loop ground source heat pump;with a minimum COP of 3.3
or
Open loop water source heat pump with a maximum pumping hydraulic head of 150
feet and minimum COP of 3.6
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency.
3d HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0
Ductless Split System Heat Pumps,Zonal Control:In homes where the primary space
heating system is zonal electric heating,a ductless heat pump system shall be installed
and provide heating to the largest zone of the housing unit
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and the minimum
equipment efficiency.
4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: 1.0
All heating and cooling system components installed inside the conditioned space.
This includes all equipment and distribution system components such as forced air
ducts,hydronic piping,hydronic floor heating loop,convectors and radiators.All
combustion equipment shall be direct vent or sealed combustion.
For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of
supply ducts may be located outside the conditioned space.All metallic ducts located
outside the conditioned space must have both transverse and longitudinal joints sealed
with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections
must be made with nylon straps and installed using a plastic strapping tensioning tool.
Ducts located outside the conditioned space must be insulated to a minimum of R-8.
Locating system components in conditioned crawl spaces is not permitted under this
option.
Electric resistance heat and ductless heat pumps are not permitted under this option.
Direct combustion heating equipment with AFUE less than 80%is not permitted
under this option.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the heating equipment type and shall show the
location of the heating and cooling equipment and all the ductwork.
6
Op DESCRIPTION CREDIT(S)
Sa EFFICIENT WATER HEATING 5a: 0.5
All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75
GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.`
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the maximum flow rates for all showerheads,kitchen
sink faucets,and other lavatory faucets.
5b EFFICIENT WATER HEATING 5b: 1.0
Water heating system shall include one of the following:
Gas,propane or oil water heater with a minimum EF of 0.74
or
Water heater heated by ground source heat pump meeting the requirements of Option
3c.
or
For R-2 occupancy,a central heat pump water heater with an EF greater than 2.0 that
would supply DHW to all the units through a central water loop insulated with R-8
minimum pipe insulation.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the minimum
equipment efficiency.
Sc EFFICIENT WATER HEATING 5c: 1.5
Water heating system shall include one of the following:
Gas,propane or oil water heater with a minimum EF of 0.91
or
Solar water heating supplementing a minimum standard water heater.Solar water
heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the
Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300
Certified Solar Water Heating Systems
or
Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards
of NEEAs Northern Climate Specifications for Heat Pump Water Heaters
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall specify the water heater equipment type and the minimum
equipment efficiency and,for solar water heating systems,the calculation of the
minimum energy savings.
5d EFFICIENT WATER HEATING 5d: 0.5
A drain water heat recovery unit(s)shall be installed,which captures waste water heat
from all the showers,and has a minimum efficiency of 40%if installed for equal flow
or a minimum efficiency of 52%if installed for unequal flow.Such units shall be
rated in accordance CSA B55.1 and be so labeled.
To qualify to claim this credit,the building permit drawings shall include a plumbing
diagram that specified the drain water heat recovery units and the plumbing layout
needed to install it and labels or other documentation shall be provided that
demonstrates that the unit complies with the standard.
6 RENEWABLE ELECTRIC ENERGY: 0.5
For each 1200 kWh of electrical generation per each housing unit provided annually
by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits.
Generation shall be calculated as follows:
For solar electric systems,the design shall be demonstrated to meet this requirement
using the National Renewable Energy Laboratory calculator PVWATTs.
Documentation noting solar access shall be included on the plans.
For wind generation projects designs shall document annual power generation based
on the following factors:The wind turbine power curve;average annual wind speed at
the site;frequency distribution of the wind speed at the site and height of the tower.
To qualify to claim this credit,the building permit drawings shall specify the option
being selected and shall show the photovoltaic or wind turbine equipment type,
Provide documentation of solar and wind access,and include a calculation of the
minimum annual energy power production.
a.Projects using this option may not use Option la,lb or 1c.
b.Projects may only include credit from one space heating option,3a,3b,3c or 3d.When a housing unit has two pieces of
equipment(Le.,two furnaces)both must meet the standard to receive the credit
c.Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and
showerheads)shall comply with the following requirements:
1.Residential bathroom lavatory sink faucets:Maximum flow rate-3.8 L/min(1.0 gal/min)when tested in accordance
with ASME A112.18.1/CSA B125.1.
2.Residential kitchen faucets:Maximum flow rate-6.6 Undo(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1.
3.Residential showerheads:Maximum flow rate-6.6 L/miu(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1
7
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
F-,
N -�o�
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed.In addition,based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
R-Valuea U-Factora
Fenestration U-Factor n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGCb•e n/a n/a
Ceilingk 49' 0.026
Wood Frame Wall9,°'." 21 int 0.056
Mass Wall R-Value' 21/21h 0.056
Floor 309 0,029
Below Grade Wall°°' 10/15/21 int+TB 0.042
Slab R-Value&Depth 10,2 ft n/a
'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
1. Small Dwelling Unit: 1.5 credits
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area.
Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet.
�. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in#1 or#3.Exception: Dwelling units serving R-2 occupancies shall require 2.5
credits.
C3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 0.5
1b Efficient Building Envelope I 1.0
1c Efficient Building Envelope I 2.0
-$.5--
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 2b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5
3a High Efficiency HVAC 3a 1.0 1.0
3b High Efficiency HVAC 3b 1.0
3c High Efficiency HVAC 3c 1.5
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 5a 0.5 05
r,
5b Efficient Water Heating 5b 1.0
5c Efficient Water Heating 5c 1.5 1.5
5d Efficient Water Heating 5d 0.5
6 Renewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits 3.50
*Please refer to Table R406.2 for complete option descriptions
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and
ACCA Manuals J and S.This calculator will calculate heatina loads only.ACCA procedures for sizing cooling systems should be used to
determine cooling loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-
factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each
section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU
Energy Extension Program at(360)956-2042 for assistance.
Project Information Contact Information
toe Cedarland
Allyn 253-208-8136
Heating System Type: lul Other Systems p tit PL„p
To see detailed instructions for each section,place your cursor on the word"Instructions"
Design Temperature
insiruc�ions Design Temperature Difference(AT) 47
S h e I to n AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
instructions Conditioned Floor Area(sq ft) 1.670
Average Ceiling Height Conditioned Volume
-- Average Ceiling Height(ft) F 8.6 13,360
Glazing and Doors U-Factor X Area = UA
0.30 185 55.50
Skylights U-Factor X Area = UA
0.50 —
Insulation
Attic U-Factor X Area = UA
R-49 0.026 1.670 43.42
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
No Vaulted Ceilingsin thi — 0
Above Grade Walls(see Figure 1) U-Factor X Area UA
R-21Intermediate 0.056 983 55.06
Floors U-Factor X Area UA
0.025 1,670 41.75
Below Grade Walls(see Figure 1) U-Factor X Area UA
No Below Grade Walls in tE - — J —
Slab Below Grade(see Figure 1) F-Factor X Length UA
No Slab Below Grade in t
Slab on Grade(see Figurer) F-Factor X Length UA
No Slab on Grade in this —
z:.ao
Location of Ducts
Duct Leakage Coefficient
Uncondltloned Spa - 1.10
Sum of UA 195.73
Envelope Heat Load 9,199 Btu I Hour
Figure 1. Sum ofUAXAT
Air Leakage Heat Load 6,782 Btu/Hour
volumeX 0.6XATX.01B
Above Building Design Heat Load 15,981 Btu/Hour
Air Leakage-Envelope Heat Loss
Building and Duct Heat Load 17,579 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 24,610 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07101113)
SHEAR WALL INSPECTION-2015 INTERNATIONAL
BUILDING CODE (IBC)
A separate inspection in addition to the inspections required in the IBC,
Section 110 shall be required in accordance with the 2015 IBC, Section
1705.12.2 and Section 1707.1. The additional inspection is required
when shear wall fastener spacing is required to be 4 inches or less. The
shear wall schedule shown on sheet designate wal4m
with fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County
Building Department, a WABO certified inspector, certified to inspect
lateral connections, the Engineer of record (EOR), or and authorized
representative of the (EOR). The special inspectors' duties and
responsibilities shall be as specified in chapter 17. When a third party
inspector is used to perform the inspection, special inspection reports
shall be submitted to the Mason County Building Department, 615 W
Alder St, Shelton, WA 98584 and also available on site for review by the
Building Official. Inspection reports shall be completed and submitted to
the Mason County Building Department in a timely manner and shall be
submitted prior to the framing inspection of said project.
SHEAR WALL INSPECTION-201 S INTERNATIONAL
BUILDING CODE (IBC)
A separate inspection in addition to the inspections required in the IBC,
Section 110 shall be required in accordance with the 2015 IBC, Section
1705.12.2 and Section 1707.1. The additional inspection is required
when shear wall fastener spacing is required to be 4 inches or less. The
shear wall schedule shown on sheet esignate wall
=with fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County
Building Department, a WABO certified inspector, certified to inspect
lateral connections, the Engineer of record (EOR), or and authorized
representative of the (EOR). The special inspectors' duties and
responsibilities shall be as specified in chapter 17. When a third party
inspector is used to perform the inspection, special inspection reports
shall be submitted to the Mason County Building Department, 615 W
Alder St, Shelton, WA 98584 and also available on site for review by the
Building Official. Inspection reports shall be completed and submitted to
the Mason County Building Department in a timely manner and shall be
submitted prior to the framing inspection of said project.
Window Schedule & Glazing Area CED 1670
Ply-Gem U-Factor .22
Front Elevation area
1 6050 30
1 1050 5
1 1050 5
Right Side Elevation
1 5040 20
Rear Elevation
1 3050 15
1 3050 15
1 6040 24
1 6068 40.8
1 6050 30
Totals 9 184.8
Wall Square Footage 1168
Walls minus Windows 983.2
MASON COUNTY COMMUNITY SERVICES �0�,
PERMIT ASSISTANCE CENTER: Permit No:
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
615 W.Alder Street,Shelton,WA 98584
Phone Shelton:(360)427-9670 ext. 352•Fax:(360)427-7798 Phone
1854` Belfair.(360)275-4467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION RECEIVED
BUILDING JUL 072017
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMA der Street
NAME:C W NAME:rn 'f— A �LP-
MAILING ADDRESS: ( MAILING ADDRESS:
CITY: TATE: ZIP: CITY: STATE: ZIP:
PHO #1: PHONE: CELL:
PHONE#2: EMAIL :
EMAIL: , ' &I REG# EXP. /
CONTACT PERSON : OWNERt CONTRACTOR❑ OTHER❑
NAME"JVC ,JCDAP� d6l p MAILING ADDRESS:Sf rnE nS ocomc— ,
CITY: STATE: ZIP: PHONE:0b) 1 J LL:
EMAIL: QXl
PARCEL INFORMATION: Mit f U&A•
PARCEL NUMBER(12 Digit Number)'o�a�47t1./ W�i I ZONING Imo" r
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITE ADDRESS I CITY
DIRECTIONS TO SITE ADDRESS —
ON
IS THE'PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO)�
IS PROPERTY WITHIN 200 FT: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM❑
TYPE OF WORK: NEW4 ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) RMI nc-AS. —
IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS ,5 NUMBER OF BATHROOMS
HEATED STRUCTU 7 YES(Whole Bldg) YES(Part[s]of Bldg) ❑ NO El
DESCRIBE WORK
0hL'MXV TWID 'Saa6WbIL- lLf
(Valuation/Project Bid Amount:$ )
S UARE I{DOTAGE:
1ST FLOOR sq.ft. 2ND FLOOR_ sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE_sq.ft. Attached Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURE NFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE L LENGTH
WIDTH BEDROOMS I3 SERIAL NUMB
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner and I further declare that I am entitled to
receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including
any easement holder or parties of interest regarding this project. The owner or legal representative, represents that the
information provided is accurate and grants employees of Mason County access to the above described property and
structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON
UNTY CODE 14.08.42)
X
17
S@6ature ot OWNER(Must be signed by the OWNER) 0, Date
DEPARTMENTAL REVIEW . APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No: X 7
PERMIT ASSISTANCE CENTER:
•BUILDING •PLANNING •FIRE MARSHAL
615 W.Alder St-Shelton, WA 98584 RECEIVED
www.co.mason.wa.us
f 4 Phone Shelton: (360)427-9670 ext. 352• Fax:(360)427-7798
Phone Belfair:(360)275-4467• Phone E/ma:(360)482-5269 JUL 0 7 2017
BUILDINqLUMBING & MECHANICAL PERMIT APPLICATION 615 W. Alder Street
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: NAME:�-
MAIL ADDRE S: MAILING ADDRESS:
CITY TATE: ZIP: CITY: STATE: ZIP:
I"PHONE: — PHONE: CELL:
2nd PHONE: EMAIL :
EMAIL: L&I REG EXP. / / 1
WM
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number): P�20) Zoning - P
LEGAL DESCRIPTION (Abbreviated):
SITE ADDRESS: — ( ITY`:t
DIRECTIONS TO ITE ADDRESS: - V LZ'�1—
►' TO�I rw
TYPE OF JOB:
NEW Y_ADD ALT REPAIR OTHER USE OF BUILDING
LOCA ON OF FIXTURES/UNITS— 1sT FLOOR 2ND FLOOR BASEMENT GARAGEX OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.oLFixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_
Toilets Type of Unit No�nits Fees
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Z Wood/Gas/Pellet Stove
Dishwasher l Kitchen Exhaust Hood
Hose bibs � Dryer Vent Z
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INS ION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE 7APPLATI N.
x ZZ��/7
gnature 06wner ate
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Visit us on-line: http://www.co.mason.wa.us/community_dev/ Rev:1/27/2016 AN