Loading...
HomeMy WebLinkAboutBLD2012-00188 Garage Final - BLD Permit / Conditions - 7/14/2014 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 L� RESIDENTIAL BUILDING PERMIT BLD2012-00188 OWNER: FORREST SWANSON RECEIVED: 4/4/2012 CONTRACTOR: LICENSE: EXP: ISSUED: 5/11/2012 SITE ADDRESS: 430 E LAKELAND DR ALLYN EXPIRES: 11/11/2012 PARCEL NUMBER: 122205300034 LEGAL DESCRIPTION: LAKELAND VILLAGE 4 TR. 34 PROJECT DESCRIPTION: DIRECTIONS TO SITE: DETACHED GARAGE WITH ATTACHED CARPORT ST RT 3 TO ALLYN, L ON LAKELAND DR, TO SITE ADDRESS ON THE RIGHT SIDE General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building: Garage-Detached 1,200 Valuation: $ 52,494.00 Building Height: 17 Occ. Status: Primary Basement: CARPORT 300 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 150.0 Ft. Shoreline: Ft. Water Body: Rear: N 20.0 Ft. Slope: Ft. SEPA?: Unkn Model: Width: Ft. Side 1: W 5.0 Ft. Shoreline Desig.: blOtlApplicable Year: Serial No.: I Side 2: E 21.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 4/4/2012 $432.09 S1201200000001 Planning Review Fee GMM 4/4/2012 $205.00 S1201200000001 EH Plan Review KKK 4/4/2012 $ 103.00 S6201200000001 Building State Fee LDK 4/18/2012 $4.50 S1201200000001 Building Permit Fee LDK 4/18/2012 $664.75 S1201200000001 Total $1,409.34 BLD2012-00188 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2012-00188 CONDITIONS FOR BLD2012-00188 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982—The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior any further inspections being performed or approvals granted. 3) Owner/Agenj is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of ved documents will result in failure of required building inspections. X 5) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be wplied for, reviewed and approved prior to the change. X 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 7) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Depart raaent�rior to any further inspections being performed or approvals granted. X 8) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X BLD2012-00188 Please refer to the following pages for conditions of this permit. Page 2 of 5 9)' A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknQ�Vging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X �� 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X fJY 11) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X 12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation.X 13) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. / X , 14) Placement of structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 15) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must. .be re iewed and approved by Mason County prior to construction. X ! BLD2012-00188 Please refer to the following pages for conditions of this permit. Page 3 of 5 161 CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shaft-e made prior to requesting additional inspections. X t)i 17) All property lines shall be clearly identified at the time of foundation inspection. X 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X � 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (older have prevent re�_action from being taken. No more than one extension may be granted. 20) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flas ing. Install metal connectors approved for contact with the new types of pressure treated material. X 21) Retaining walls needed to support a surcharge su_rh as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 22) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 23) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan",to ensure these structures are shown and meet the setback conditions listed. X 24) Approved per dim ens and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 25) Applicant acknowJe gees that this development is subject to policies and regulations of Mason County Comprehensive Plan and Development Regulations. X ��✓✓ 26) Application acknowledges that the structure is only permitted for a land use and occupancy consistent with the current zoning of the parcel. Zoning is Allyn UGA R1-P zone (residential platted) X k BLD2012-00188 Please refer to the following pages for conditions of this permit. Page 4 of 5 27) All construction and demolition debris must be removed from the site after project completion. Proper dispos of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X_� 28) Prior to final approval, all upland areas disturbed or newly created ction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access o the above described property and structure for review and inspection. OWNER OR AGENT: DATE: 14e 12— BLD2012-00188 Please refer to the following pages for conditions of this permit. Page 5 of 5 CA o CONCRETE MECHANICAL MANUFACTURED HOME o Date By D N Footings I Setbacks Gas Piping Ribbons Z o Interior Date By Interior-Date By Date � By 00 Exterior Date. _ �By Exterior-Date B Z Point Load I Isolated Footings INSULATION Date By T BG I SLAB INSULATION __..._ Q Date By Data By FIRE DEPARTMENT X Foundation Walla Floors Date By M Date By r Data By DECKS FRAMING Walls Date By Date 7 )C By Data By PROPANE TANKS PLUMBING vault Date Sy Date BY OTHER _._.._..___a_._. .. .._ Groundwork Attic Date By Date By Type. Date By MWN DRYWALL Type. Date By int Brace Wall Date Eby W v m Date By m FINAL INSPECTION 0 y Water Line Fire Seperation N m CD Date By Date By Date ? By 444t— s Pass or Request Inspect. c r Type of Insp. Fail Date Date Dane By Comments co s J", L - - Z peoR o 4 f o aC/ W o + � Err m / r -S1G/' V w 'r LO L l . 61 iv '7 CD 0 r t Permit# MASON COUNTY BUILDING 111 426 W, CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 61-3 ' -V/� This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance j� oy ?Ad7 G Ue rc JO o U G L Z i 17- Z HA' 2- X Z ' OL hl,-?vf ,C=��� 1� =�f' .9 aD�oy,� dii' �1.Po v/i 4 Fi,x - Z=- �Lt, - �O�o v iTip ✓ T G� c2R Woyr- You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK 12 Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural damage incurred by recent Oki y , "natural/man made" This is not a comple( inspection disasters.This is NOTa Date j -2-C) Department c '� ;' a, CORRECTION NOTICE. Inspector T,j 0* N� N* VT , '�•�l� �4 ; ' TH111h, TA* mw Permit# /Z/OD 0 MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 930 k u pr- Thisstructure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance )CO •10 4. P,o-r_ 5ke To -rrr P rz 1 k i9 l,:tom. n.- 1,u, LA iu t.s Gc...�r.:� ►/�.�. 1 �;.-( LDaZf S 1'��..�-2� G r'CS� -tD I Li�G.2 - c�cs�Z r_ 5 G' G /' �'F� `v�- d-l✓ , I l t &) -f e,.-,ZA CJ2 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office W Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑ This is not a complete inspection /� disasters.This is NOT a Date 7�vj j Department (3VJ CORRECTION NOTICE. Inspector Wife n k 4 NOT `iv1* ,0V ' ' THImk T,,ivm * qr Outlook.com - tetta-b@hotmail.com Page 1 of 1 FSea'rMe&nailReply Dellte Fr tjYeattj&f jSS Sweep Move to CatfgQli@s!St swanson Folders forrest Swanson Add to contacts4:10 Axel Swanson Inbo x 2 To:tetta-b@hotmail.com zfii 10 Add friend Junk 62 Already friends on Facebook? Drafts Sent Sent from my iPod Deleted Begin forwarded message: Amazon Orders Banking From: "Kelly Huggins" BankR. <kellvh@peninsulatruss.com> College Date:July 11, 2014, 8:09:43 AM PDT To: <axelswany32@live.com> Employment Subject: attic truss Pay stubs Reply-To: "Kelly Huggins" <kellvh@peninsulatruss.com> Random Import Info Taxes After reviewing the attic truss we have Verizon determined that it is ok to lower the ceiling New folder height by nailing on a new 2x4 collar tie with a minimum of 2 2x4 vertical bracing from original collar tie to new one. Thanks, Kelly Huggins kellvh@peninsulatruss.com 360-297-6020 Content from© © 2014 Microsoft Terms Privacy&cookies De\hdaqmr9ore Turn off https://blu178.mail.live.com/default.aspx?id=64855 7/11/2014 :. , , . . �I: ■ �■ ■■Mill �������1►■■■■■�■■ !! .' ■� ■oOl .. 'ems_ _ _. ■■■ ■OIL==.—•,—.=�1�1■■■■■■■■■■■■ slow goo MOO 11 Fa I ON ■■IMI■1 Qo■!�■�M�l�iiiii�IM��i�i� ■ I■ ■i� _ 11 'iM ME■■ ■ ■ ■ j as ■■■■■■■ ■®1�■■ 111�_ _ ■■■■■■■ ■ ■ 0 � ■■■■■■■■■ ■ MIN ■■■■■MEMO ■ EMM EOEME■EO■ MOM MM MONO No ■ ■■■■■E■OE■■OE■■■MEME■EM RM Mom ■■■■■■■_■.■■■■■■. Wei 910.0 • • C Polio it�6LA-Dc. • _.• r_ • M •- ao- L,S� I` l`,4 I LL I I I I I L` N --- qs I o1 - IIII II TOPOGRAPHY PROFILE Direction: Irvµ Scale: Approval:for office use Building Permit number. I} ,y 3 +I-i-e. III, � Building: Owner/Applicant 147 µo D 14'.it Date of Planning: ,. i 1.Cr ►+Lc—41v application: Env. Health: Parcel Number. C)M2 11 like,-+ Q-. an ya•" M"-3 2,0 C MASON COUNTY PERMIT NO. I BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 �. Shelton (360) 427-9670 • Belfair (360) 275 4467• Elma (360)482-5269 On the web www.co.mason.wa.us l� APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Company Name Mailin Address hr Mailing Address City State\e/A_Zip Code 04 S L 21- City State Zip Code Phone , Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address Ca k ��.t�,Da W E'- 1(,,I e, 1 LfY) E Mail Address Drivers Fn DOB (� --�a -1 Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION- 12 Digit Parcel No - Fire District Legal Description Site Address(Please include street name,street number and city) `-1.10 Y_ I ��►r� 4r�: la I ! v h i,� � i-24 Directions to site 1-4 r _� +1 14 i I v vt Will timber be cut and sold in parcel preparation?Yes.` o Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB-N Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building Describe Work No. of Bedrooms No.of Bathrooms Square Footage- 1 st Floor 2nd Floor FI Basement Deck Covered Deck --Other Sq. ft. Gara e,�_ Attached Detached Carport '�L►Y' Attached Detached MAiqtiFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,i have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the infomriation provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTlNUAVn0 WORK IS BY MEANS OF A PROGRESS INSPECTION. Date: 1 Owner 1 wners Re resentafive/Contractor (indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by " .� Date q- DEPARTMENTAL REVIEW APPROVED DENIED ; NOTES Building Department Z L l Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing& Base Fee Planning Review Fee Mechanical& Base fee Other �GFy Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation$ TOTAL FEES Name w� Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14,Chapter 14.48 a sormwater site plan is required whenever a building application is made for residential development,or redevelopment', with more than 2,000 square feet of impervious surface. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To-calculate Impenraois Sufaces Tease Com��'ete.This Tab? _ Surface Type Length X Width = Area "All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) Driveway X = Length of drive begins at the right of way X = Parkin Are A.--' = X = Any paved, gravel or packed area per definition above table X = PabosMalks X = X = Any paved, gravel or packed area per definition above table X = ers X ( _ X `if.the total impervious area bf the proposed site X = development is greater than 2000 square feet a mall ParceLStormwater;Site Plan;is Required .. Total Impervious.Surfaae Area m(su of'all areas) l If the Total Impervious Surface Area is LESS TH ��00 S eet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County aret described property for review and inspection as may be required. I X Owner/Agent/Contractor(circle one)Dater If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, w..l 4w, the information provided on page 2 of 2. nub Page I of 2 APR 1 O Zo l Z Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48.section 14.48.70).You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has, or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. OwnerBuilder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative, or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST hmer Is Name: u//(,di117 L Date. l Reviewed By. 3ocuments: _� uilding Permit Application Completed /Storniwater Checklist ug Intake Checklist Completed, plan includes:Allowable building area,roof overhangs,decks,etc. ire Apparatus Access Road info required? Yes/No N�Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) O Other. Specify. _Mechanical/Phmmbipplication-WATER HEATER FUEL TYPE/LOCATION eearng? Yes^{�o Snow load: Seismic: tuck Plan—approved snow load: Seismic: ✓tanufactured Homes—4 FLOOR PLANS Foundation Type: ANSI/Manufacture method Engineered footing/foundation Basement Decks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required. 7onstrucfion Plans:_3 COMPLETE SETS X Plans Legible X Recognized Scale XC Elevation Views _Cross Section ] Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors) _Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F. ??—stairs?) Deck Framing Plan,incl cov.porch framing 'Zan Details: Roof framing details,truss lay-out may be needed (Hip and girder location shown) . Wall Framing-Does bearing-wall height exceed 10'?(Engineering may be requfr4 ) g Floor f-aming: Floor joists(size&spacing): Floor beams: x ndow headers. Typical header. C9 er beams- Window eeX Foundation:footing size,reinforcement �� crete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be requirea;see details) � 5 Landings at all exits?Less than 30"above grade?Y/N eated By Furnace-Location of Furnace Fuel type: N ireplace/Stove Information Shown-Fuel Type? Locotion(s): d Sizes Marked on Plans Braced wall panels(shear walls)marked on plans or lateral engineering? _ 2-story garage? (Engineering may be required) 19 story of two story D1—450%,D2—55% COMMENTS: ENGNEERING REQUIRED WILDING Braced wall panels/brace wall limes are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: ,Snow_ps£ IRREGULAR BU1L DINGS R3012-222 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: ED 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft beyond the braced wall line. APR 1 tom. Z � 3)End of BWP extends more than 1 ft.over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft,or 50%of the least floor or roof d mensioNASO N COUNTY 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete constriction(exc:fireplaces, chimneys,and veneer). When this applies the entire story shall be designed-In accordance with accepted engineering practice. H:\permh tech building checklistdoc Revised 11-29-2007