Loading...
HomeMy WebLinkAboutBLD2013-00765 SFR - BLD Permit / Conditions - 9/30/2013 ' Inspection Line(360)42/-/262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 1� RESIDENTIAL BUILDING PERMIT BLD2013-00765 OWNER: EDWINA BENT RECEIVED: 8/30/2013 CONTRACTOR: LICENSE: EXP: ISSUED: 9/30/2013 SITE ADDRESS: 4860 E STATE ROUTE 302 BELFAIR PARCEL NUMBER: EXPIRES: 3/30/2014 LEGAL DESCRIPTION: TR 8 OF GOVT LOT 2 &TAX 1291 & 7121 PROJECT DESCRIPTION: DIRECTIONS TO SITE: SFR ADDITION (10 X 17.5) WITH COVERED FRONT PORCH FOLLOW ST RT 3 TO ALLYN, R ON General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: vb Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: R3 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:175 Valuation: $ 19,026.87 Building Height: Occ. Status: Primary Basement: Coventry 24 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 160.0 Ft. Shoreline: Ft. Water Body: NORTH BAY/CASE INI Rear: W 190.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 46.0 Ft. Shoreline Desig.: Rural Year: Serial No.: Side 2: S 17.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 9/9/2013 $ 199.71 S1201300000001 Planning Review Fee GMM 9/9/2013 $205.00 S1201300000001 Building State Fee DLC 9/24/2013 $4.50 S120130000000i Building Permit Fee DLC 9/24/2013 $ 321.25 S1201300000001 ADJUST--Plan Check Fee DLC 9/24/2013 $9.10 S1201300000001 Total $739.56 BLD2013-00765 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FOR BLD2013-00765 CONDITIONS FOR BLD2013-00765 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-80 -0 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building De or to any further inspections being performed or approvals granted. X 3) Ow / t's responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or remov I o a roved documents will result in failure of required building inspections. X 5) All wall cavities serving as exterior walls, exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspect prior o covering. Insulation R-values shall be as follows: 2x4 wall cavities min. R-15 and 2x6 wall cavities min. R-21. X 6) THE FOU DA ION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X 7) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildin rt ent prior to any further inspections being performed or approvals granted. X BLD2013-00765 Please refer to the following pages for conditions of this permit. Page 2 of 5 8I Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric wall monut, Compliance Method: Component performance with 5% reduction for 0.5 energy credit, Window (Max U-Factor):0.25, No Skylights, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-38, Ceiling Insulation R-49. In addition the following credit from Table 9-1 shall be completed: 1A(window u-factor 0.25 or less and floor insulation r-38) X� 9) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X 10) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X 11) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. `NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor i c n ledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev X 13) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X BLD2013-00765 Please refer to the following pages for conditions of this permit. Page 3 of 5 14) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site ana iviuz)i ivv i aaverseiy rrnpaci adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 15) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance o I tion, must be reviewed and approved by Mason County prior to construction. X 16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector h I made prior to requesting additional inspections. X 17) All property lines shall be clearly identified at the time of foundation inspection. X �pY� 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason C n r nances and building regulations. X 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder ha v nted action from being taken. No more than one extension may be granted. X 20) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM X ROAD fj�' X p�J 21) Approve r i ensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 22) Applicatio a cnowledges that the structure is only permitted for a use consistent with the current zoning of the parcel. Zoning is Rural Residential 5 zone. X BLD2013-00765 Please refer to the following pages for conditions of this permit. Page 4 of 5 23) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County li e Master Program. X _T 24) All construction and demolition debris must be removed from the site after project completion. Proper S of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X_ '7 25) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent a r properties. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X 26) Prior to final approval, all upland areas disturbed or newly re ed y construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 27) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approve Sit P an"to ensure these structures are shown and meet the setback conditions listed. X 28) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection. The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT:y/ !1/� DATE: F 1,y O BLD2013-00765 Please refer to the following pages for conditions of this permit. Page 5 of 5 W ' oCONCRETE MECHANICAL MANUFACTURED HOME m o m Datew Footings Setbacks Gas Piping By Ribbons I o Interior Date By Interior-Dane By Date By m 0) Extenor Date By Exterior-Date B v INSULATION Point Load J Isolated Footings Date By Z Date By BG I SLAB INSULATION FIRE DEPARTMENT ___ D Data By Foundation Wails Floors Date By Date By Data By DECKS FRAMING walls Date By Date 12 - ((— (3 By lam/ Data 1 2— 1 t_ 3 By�J PROPANE TANKS PLUMBING Vault Date By Date 1 2-((,r3 By l OTHER Groundwork Attic Date By Date By Type- Date By D.W.V DRYWALL Type- -0 Date 8y Int.Brace Wall Date By m Date By FINAL INSPECTION 17- m w Water Line Fire Seperation iV CD CD Date By Date By Date s Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments c CD EP cc � -�f� �� 1 16-36-1 zc c T tJ 0 0 ; i) 0 0 rr zo l� &� cd� Cn ,v 0 Permit#_ [ — MASON COUNTY BUILDING 111426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location (1<!r- O This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance s — z You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing please contact our office Make corrections, items will be checked on next inspection regarding possible structural ® damage incurred by recent "natural/man made" This is not a complete inspection disasters. This is_NOT a Date 41— Department CORRECTION NOTICE. Inspector 000 NUT P P10 ,0V ' THI 140k T4G ,Permit# MASON COUNTY BUILDING II/ 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location fig(? j 6 t 2,, �O 2- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance C. f r n c i 21- C. i �n D G J i r e 41' c - � Gc o r ,� ll p ff c / G u r T 4- ` Lam You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑This is not a complete inspection disasters.This is NOTa Date �o z 3- Department 1 CORRECTION NOTICE. Inspector l- -J n* of %L �T , I ;.1* -71'A THf , Tl * mg Kermit# 13 76�— MASON COUNTY BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location q�&o l� 5• �OZ This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance I� Sew A-rzft twd --n ,,r CP--4-&z4 SG�rcws You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office �] Make corrections, items will be checked on next inspection regarding possible structural �$ G, damage incurred by recent OK to "natural/man made" ❑This is not a))complete inspection disasters.This is NOT a Date l7/� ?i/ 3 CORRECTION NOTICE. Department Inspectorl�/ D* ,# NIlmLoT i I '�•�/� �4 ' ' THI , T 'm-* Aw n •10 Name�&K.17 Parcel# Z22g "2`f - O BLD# Mason County Department of Community Development 'man�irceh§tormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surfacez. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildin s X = Yl X = Measurements for buildings are taken at the perimeter of the farthest projections(example: r�'1 X = eaves/gutters) X = Driveways E:-C v541 Ap = = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X X = Any paved, gravel or packed area per definition above table X = Others X = X If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) If the Total Impervious Surface Area LESS THAN 2000 Square Feet, ase read,acknowledge and sign below. Based Upon the information you have provid NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspectio may be r ed. X caner/ gent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page I of 2 RECEIVED AUG 2 6 2013 426 W. CEDAR ST. Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: httt)//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout' PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have fiirther questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:(360)-427-9670 EXT.450 Mail: P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT.352 Mail: P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St,Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for fmal inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 sue' °pL'w• MASON COUNTY PERMIT NO.'bI 261 - DEPARTMENT OF COMMUNITY DEVELOPMEI,Wr- F BUILDING•PLANNING•FIRE MA fR5HAL lAn Mason County Bldg. II 6 Westt Cedar tree�V� - 2011360)275-4467 Belfa ext.522 �I PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352 19P 1h/ rFnAF BUILDING PERMIT APPLICATION B U I L GN-4 OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: EdW;Aa F Bent NAME: MAILING ADDRESS:- I I'7-0 E Sfniv Rcute, Iola MAILING ADDRESS: CITY: Utvlou STATE: G)A_ZIP:995g2 CITY: STATE: ZIP: PHONE:86a-999-7//J CELL:gal-k02-3'YO 1 PHONE: CELL: EMAIL:c4ag:Jebrst Q corncan+.n.et EMAIL : L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) 12.2 2 8 2 y 0O()S p FIRE DISTRICT LEGAL DESCRIPTION(ABREVIATED):I'll g of GOVT LA-r 2 t rAK /2 g r + 712 T SITE ADDRESS y 8&0 E st-at,- u� 309 r CITY ;•- DIRECTIONS TO SITE ADDRESS ( &trr S tis On bull, steles &�dri Veu)au on nuts 302. IS PROPERTY WITHIN 200 FT: SALTWATER LAKE❑ RIVER/CREEK JX POND❑ WETLAND❑ SEASONAL RUNOFF ❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES❑ NO R TYPE OF JOB: NEW ❑ ADDITION K ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(RESIDENCE,GARAGE ETC.) 7�,es iderLce_ IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS DESCRIBE WORK Add,f� 1-0 l ,J,hg Room of 1�i',r6- sa. 0 � SQUARE FOOTAGE: 1ST FLOOR 1*7 sq.ft. 2ND FLOOR_ sq.ff. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK�y_ ft. COVERED DECK_ sq.fL STORAGE sq.ft. OTHER sq.fL GARAGE sq.ft. ATTACHED❑ DETACHED❑ CARPORT sq.fL ATTACHED ❑ DETACHED❑ MANUF OME INFORMATION: *4 COPIES OF THE F �E ODEL LENGTH TH BEDROOMS BATHS SERIAL NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION-INACTIVITY OF THIS P T APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. x�u.�z.�r��' ,�30 A la(o l tt 3 Signature of Applicant x Edwina F -Rent`' OWNE /REPRESENTATIVE/CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT - PLANNING DEPARTMENT FIRE MARSHAL 5� s EXTG. HOUSE 2304 SQ, FT. IMPERVIOUS RECEIVEDAUG 2 6 2013 PLAN EXTG. CABIN 555 50. FT. IMPERVIOUS NEW ADDITION Ilq 50. FT. IMPERVIOUS 426 W CEDAR ST., - TOTAL 5056 50. FT. IMPERVIOUS s z / � wELL P LAN NJ ALL SETBAC RE MEASURED a FRqJVrTHE FURTHEST 3g' PR TION OF THE BUILD 000 lb - NEw ADDTION Gas I - � D r ORG i�, EXTG. GABI 4 COVERE '"41% nod 1.3 APPROVED MASON COUNTY DCD PLANNING DEDE BENT SITE PLAN REQUIRED TO BE ON SITE '- ^�. EXTG. / CHANGES SUBJECT TO APPROVAL 4060 E STATE ROUTE 502 I ►d�Vl__ / �y� SFR / y 2504 50. FT. By Date ZZ BELFAIR, WA g8E20 IMPERVIOUS # I22282400080 I TE FLAN �Tn(.L - n off. THIS SITE PLAN IS DRAWN BASED ON DATA 5UPPL I ED BY CLIENT AND WITHOUT BENEFIT OF SURVEY OR TOPOGRAPHY