Loading...
HomeMy WebLinkAboutBLD2010-00892 Garage - BLD Permit / Conditions - 10/25/2010 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 04 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2010-00892 OWNER: IVAN CUNNINGHAM RECEIVED: 10/1/2010 CONTRACTOR: LICENSE: EXP: ISSUED: 10/25/2010 SITE ADDRESS: 91 E WINDSTAR RD UNION EXPIRES: 4/25/2011 PARCEL NUMBER: 322357590171 LEGAL DESCRIPTION: TR 17-A& B OF S 1/210-213 LOT: A OF SP#2798 PROJECT DESCRIPTION: DIRECTIONS TO SITE: GARAGE (UNHEATED/STORAGE ONLY) FOLLOW 106 PAST ALDERBROOK INN TO SMALL GREEN SIGN CALLED TIMER TIDES TAKE RIGHT GO TO TOP OF HILL TAKE LEFT WINDSTAR TAKE LEFT JOB ON RIGHT General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 6 No.of Stories: 2 Occ. Load: Building: Garage-Detached 1,920 Valuation: Building Height: 28 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: N 100.0 Ft. Shoreline: Ft. Water Body: Rear: S 20.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 5.5 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 5.5 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee TW 10/1/2010 $339.66 S12010000 Planning Review Fee TW 10/1/2010 $205.00 S12010000 EH Plan Review KKK 10/1/2010 $103.00 S62010000 Additional Plan Check Fee LDK 10/14/201 $192.53 S12010000 Building State Fee LDK 10/14/201 $4.50 S12010000 Building Permit Fee LDK 10/14/201 $818.75 S12010000 Total $1,663.44 BLD2010-00892 Please refer to the following pages for conditions of this permft. 1 of 5 CASE NOTES FOR BLD2010-00892 CONDITIONS FOR BLD2010-00892 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800 he person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner/Ag res onsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) This structure has been approved as unheated garage/storage only, any change to this staus will require permit/approval by Mason County prior to any changes. X 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depart any further inspections being performed or approvals granted. X Z!�& 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 6) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use perm lied for, reviewed and approved prior to the change. X 7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 8) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Build ent prior to any further inspections being performed or approvals granted. X BLD2010-00892 Please referto the following pages for oonditions of this permit. 2 of 5 9) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X 10) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknQwledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 11) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. N i drains within 30ft,down gradient of drainfield/reserve area. X 12) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertjcaLc4Qcrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 13) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the intern on nd Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X 14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in per n. X 15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your pro X BLD2010-00892 Please referto the following pages for conditions of this permit. 3 of 5 16) Place ructure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 17) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordina=ation, must be reviewed and approved by Mason County prior to construction. X 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector made prior to requesting additional inspections. X 19) All property lines shall be clearly identified at the time of foundation inspection. XM_ 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mas inances and building regulations. X 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holde nted action from being taken. No more than one extension may be granted. X 22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, co:�hecflashing. Install metal connectors approved for contact with the new types of pressure treated material. X 23) Retaining walls needed to support a surch c h as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 24) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 25) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "App a Ian"to ensure these structures are shown and meet the setback conditions listed. X BLD2010-00892 Please referto the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspe e a ent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above descri eperty� r a 'nspec OWNER OR A DATE: BLD2010-00892 Please referto the following pages for conditions of this permit. 5 of 5 o CONCRETE MECHANICAL MANUFACTURED HOME c o Date By __ _ Z o Footings! b Gas Piping Ribbons Z o Intenor Date By interior-Date By Date By Z N Exterior Date By Exterior-Date B X --�.__.��_-- Sat-up 2 Point Load!Isolated Footings INSULATION Date By > BG/SLAB INSULATION - Date By Data By FIRE DEPARTMENT Foundation(Malls Floors Date By Z Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Date By' Date By OTHER Groundwork Attic Type Dale By Date By Date By D.W.V DRYWALL Type- Int.Brace Wall Date B y W Date By Date B r y FINAL INSPECTION v Water Line Fire Separation IV Date By Date By Dale By � O Pass or Request Inspect. c s Type of Insp. Fail Date Date Done By Comments co N O ` CD CD 0 ZIA ■■ ■■Will ■■r■■■■r■r■MONO r■r rrr■Ir■rr ir■rrr■■rr■■Irrrrrr■■■ r�rrrrr■ri■u rrrrrr■rr■■■rrrrr■ r■■■■■rr■■ w r■■■■■r■■rr■■■■MI■r rrr■rrNONE �■�� ■r■■r ■■r■r■rrr �r■ ■r■rr ■ 1101011111111111r■■ ON ■■r■■n■r■r11■�rrrrr■r■r■rrrrr■r■ ■■■ ,1�►,1■■■■1■■rr■rr■r■rr■r■■■■r■ r■irr�: rrr.rrr��r��■rrr■■r■rrr■rrrr■r ■ , ,r�■rrr■ ■�■rrrrr■■■■rr■■r■rrr ■ ► ;fir■r■� ■�r�►.�!�■r■■■■rr■■rrrr ENSON ■■■MOONS No ■r■■■rr //Il�rs■■■rrr■ ■■rrr■rrr r■■■E/rr l� ��rrrrrr■rrr■■■rrrrrr �r■Emom �I�Ir■■rrr■■rrrrrr■rrrrr rr/ i■ rr■■rr■r■r■■rr■■■ ■►.:111511r� it i■c ■■rrrrrrr■rrrrrrrr M■�►.�r IsN�Ir�lrr■rrrrrr■rrrrr■■■r■ ■Er min rorrrrrr■rrrr■■rrrr■r■ rrl�■r��■■ir��r rr■rrrrrrrrrrrrrr■r rrrl�rIII: ■ M I ■■■■■■rr■■rr■■rrS■■ ■r■ NRIll ■■11 ■■■■rrr■■■■■■■■rrr■ ■■r11100 ■�11 rrr■r■r■rr■■rr■■■■■ ■■■1■rSI ■■■I■ .■■■■■■■■■■■■■■■■■■■ ■■ �r■1I■■■I■r ■■rrrrr■■■r■■■rr■■ ■■ to■o�!40.9 11�' rrr rr■■■■■■■■r■rr■ ON ■ ■� � Jrrrr■■■r■r■rr■■■r■ gyp, ■■ r�� �� ■■r■■rr■■■r■■rrlrr■ r■rr ■ r■r■■■rrr■■■rr■rrrrrr r� rr-al rr■■Mrrrrrrrrr■r■r■ MR MOM MASON COUNTY PERMIT NO. 13Ld� 1 0 BUILDING PERMIT APPLICATION Z 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION 7 Owner a ct nr Company Name r WWI MailingtAddress W:�.� Mailing Address SW I rTr�t a+riJ � , U City Oi"Qirl State Zip Code City d� r� State &0!�% Zip Code Phone C32 Other P Phone _ --4774 Other Ph., --o Lien/Title Holder »— � � Contractor Reg. # ►3L&p. E mail address Ili E Mail Address Drivers Lic. # 0 IOD933 7Q DOB Drivers Lic.# P60ZWQ`�7aH- DOB )I SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATIQN -,12 Digit Parcel No — 0/' Fire District Legal Description �)4 --H'4 ,_6Cj Site Address (Please include street name, street number and city) �u D' ll rections to site-�I I o� CC 6e'-EA-066e i ,in n, e St `r� C�'I 1�. +^ �S e t^`' OC "1\ c he �tyc�'qt'r- `t� cv, roc Will timber be cut and sold in parcel preparation? Yes/No Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - ew Add Alt Repair�o� Other PRIMARY RESIDENCE SEASONAL ❑ Use of Building Describe Work (XVC1� No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor 3rd Floor_nn Basement Deck Covered Deck Other Sq.ft. Cd�j''�}: Garage _ 02 Attached Detached �-Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. 6fd 6f IVORK IS BY MEANS OF A PROGRESS INSPECTION. / Date: 177wner/ wners Representative/Contractor �T p (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department 1 10 Planning Department _ Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES Name i rV\ Parcel# L� Z� -�o -7,BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A)Y The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666,Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added t-o the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described pr p ction as may be required. //��++ X Owner/Agent/Contractor(circle one)Date:� -zo Page 2 of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a Stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces P%ease;CompleteThis Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = --- — --__------- _---- X = If the total impervious area of the,proposed site `x X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required .: If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. -- --Owner/Builder/Agent Acknowledges that submission of inaccurate information may result ina-stop work orderor permit revocation.- - - -- Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- de spection as may be required. / I Owner/Agen Contractor circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2