Loading...
HomeMy WebLinkAboutBLD2008-00827 ReRoof - BLD Permit / Conditions - 7/7/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 _ Mason County Bldg. III 426 W. Cedar P.O. Box 186 IP14 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2008-00827 OWNER: ALEN ADAMS RECEIVED: 7/7/2008 CONTRACTOR: CLOISE & MIKE CONSTRUCTION INC LICENSE: CLOISMC991 LZ EXP: 7/22/2008 ISSUED: 7/7/2008 SITE ADDRESS: 9741 E STATE ROUTE 106 UNION EXPIRES: 1/7/2009 PARCEL NUMBER: 322355201005 LEGAL DESCRIPTION: MERRIMOUNT BILK: 1 LOT: 5 & NELY 8' LOT:6 NLY R/W PROJECT DESCRIPTION: DIRECTIONS TO SITE: Re-Roof E. Hwy 106 to address. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: RR Fire Dist.: 2 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: SEPA?: Model: Width: Ft. Rear: Ft. Slope: Ft. Shoreline Desi Side 1: Ft. g.. Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Building State Fee KKK 7/7/2008 $4.50 S22008000 Re-Roof Fee KKK 7/7/2008 $110.00 S22008000 Total $114.50 BLD2008-00827 Please referto the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2008-00827 r CONDITIONS FOR BLD2008-00827 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at X 80Q -0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X :7!2� 3) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED TO A MINIMUM OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X r(" - 4) Existing roof shall be insulated to a minimum of R-30 if: The roof is uninsulated or insulation is removed to the level of the sheating, OR All insulation in the ro`o�f_/oiling was previously installed exterior to the sheating or nonexistant. 5) Per 2003 IRC -SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X 6) Per IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X 7) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where Xchrod�connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. 8) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X �� BLD2008-00827 Please referto the following pages for conditions of this permit. 2 of 3 9) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with MasQ unty ordinances and building regulations. X ++ �� • 10) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (older haveprevented action from being taken. No more than one extension may be granted. This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property an structure for iew and inspection. OWN ER OR AGENT: DATE: ;� 7 BLD2008-00827 Please referto the following pages for conditions of this permit. 3 of 3 co o CONCRETE MECHANICAL MANUFACTURED HOME D N O o Date By D C Footings I Setbacks Gas piping Ribbons ic o Interior Date By interior-Date By Data By N Exter*x Date By Exterior-Date B 4 _ Set-up r Point Load I isolated footings INSULATION Date By Z BG I SLAB INSULATION — Date By Data ay FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING Wails Date By Date By Data By PROPANE TANKS PLUMBING Vag Date By Date By OTHER Groundwork Attic Type.. Date By Date By Data By D.W.'v DRYWALL Type Int.Brace Wall Date By Date --- -— -- y Date By FINAL INSPECTION m Water Line Fire Seperation w Dale By Date By Uata /�ij-�d By O CD00 `° Pass or Request Inspect. c 0 Type of Insp. Fail Date Date Done By Comments N s f 0 8 a 0 (n O S (D I - 0 MASON COUNTY PERMIT NO. • BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner a'`=<°�;, a Company Name Mailing Address f Mailing Address r, r ; City State — Zip Code ' City—, _ State Zip Code Y p Phone ' Other Ph. Phone Other Ph. slli-3 Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic. # DOB Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. Fire District Legal Description Site Address (Please include street name, stre t number and city) Directions to site�r 3~''` �, - ✓`' ' ' '`/!" r Will timber be cut and sold in parcel preparation?Yes/No Is property within 200'of Saltwater Lake River/ Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs /o Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building Describe Work No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement Deck_ Covered Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS�PFAPROS�yg INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS /ILL INVALIDATE THEAPPLICATION. X '¢ ! C/✓�i�,ti�. Date::� C! Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES Mason County Dept. of Community Development Mason County Bldg. 3 426 W. Cedar P.O. Box 186 (360) 427-9670 Local (360)482-5269 Elma rioShelton, WA 98584 (360) 275-4467 Belfair Notice to Obtain Final Inspection March 04, 2010 ALEN ADAMS ,`�C/C�' ( � C� 9741 E HWY 108 BELFAIR WA 98528 C IUCo Case No.: BLD2008-00827 Parcel No.: 322355201005 Proiect Description: Re-Roof The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Building Code or the code your permit was issued and your property is currently in violation status of occupancy and use. Please contact our office to make the necessary arrangements 21 days from office to make the necessary scheduled the date of this letter. Failure to contact our of ce ry inspections may result in enforcement actions. To bring your site into compliance, you must schedule an inspection. One (1) $73.00 site investigation fee will need to be paid prior to inspection along with any outstanding fees currently due on your building permit. For every inspection required after that, you may be charged $73.00 again, per inspection until final inspection and conditions are met. To schedule an inspection, please call (360) 427-9670 ext. 262. If you should have any questions regarding this notification, please contact me at (360) 427-9670 ext 726. Sincerely,�� Larry Deily l Mason County Department of Community Development Cc- Property File March 04, 2010 BLD2008-00827 ape cook A . MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street PO Box 186, Shelton,WA 98584 I8 www.co.masonma.us (3f0)427-9670 Belfair(360)275-4467 Elma(360)482-5269 NON-STRUCTURAL RE-ROOF APPLICATION Roof Slope: 1 2- Old Roof Material: k-It New Roofing Material:—L2"e Sheathing: Underlayment: l s Existing Insulation: New Insulation: Roof Slope:IRC section R904.1 Roof slope must be indicated to ensure selected roof covering is allowed on designed pitch. Roof Covering:IRC section R905 Selected roof covering must be installed in accordance with manufacturer's specifications and IRC requirements. Insulation: WSEC 101.3.2.5 exception 2a&2b Existing roofs shall be insulated to the requirements of this Code if - a. The roof is uninsulated or insulation is removed to the level of the sheathing or, b. All insulation in the roof/ceiling was previously installed exterior to the sheathing or non- existent. Attic Ventilation: IRC section 806 Enclosed attic and rafter area shall be supplied with cross-ventilation.The net area shall not be less than 1/150 of the area of the space to be ventilated.If 50%and not more than 80%of the ventilating area is provided from the upper portion of the space to be ventilated,then 1/300 is allowed. Applicant/Owner: �L�1/1 Contractor: C6, Parcel No: Permit No.: Signature: Date: ARC 10/19/04 re-roofapplication.do