Loading...
HomeMy WebLinkAboutBLD2000-01317 Garage/Storage/Office - BLD Permit / Conditions - 2/2/2001 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Moto Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2000-01317 OWNER: DOUG CHRISTENSEN 206-780-2957 RECEIVED: 10/10/2000 CONTRACTOR: SITE ADDRESS: 9421 E STATE ROUTE 106 UNION ISSUED: 08/02/2001 PARCEL NUMBER: 322355100012 EXPIRES: 0 /02/2001 LEGAL DESCRIPTION: BROOK POINT TR 12 PROJECT DESCRIPTION: DIRECTIONS TO SITE: GARAGE/STORAGE/OFFICE HWY 106, 3 MILES WEST OF TWANOH STATE PARK General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: 5N Type of Use: SF Insp. Area: No. of Bathrooms: 1 Occ. Group: R3U1 Lot Size: Deck: 74 Type of Work: ACC Fire Dist.: 6 No. of Stories: 3 Occ. Load: 2 Building:500 Garage-Attached 817 Valuation: $53,304 Building Height: 30 Occ. Status: Unknown Basement:533 Cvr Porch 72 Manufactured Home Information Setback Information Shoreline& Planning Information Make Length- Ft. Front: S Ft. Shoreline: 19.0 Ft. Water Body: South Shore Model: Width: Ft. Rear: N 19.0 Ft. Slope: 19.0 Ft. SEPA?: No Side 1: E Ft. g..Shoreline Desi Urban Year: Serial No.: Side 2: W 9.0 Ft. I Com . Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 2 Furnace<100K 1 Plan Check Fee KLW 10/10/200 $422.99 54796 Lavatories 1 Gas Outlets 2 Adjust Plan Check Fee MJB 12/21/200 $13.65 55581 Showers 1 Propane Tank 4 Building State Fee MJB 12/21/200 $4.50 55581 Water Closets (Toilets) 1 Ventilation Fan 1 Building Permit Fee MJB 12/21/200 $671.75 55581 Water Heaters 1 Mechanical Fee MJB 12/21/200 $75.30 55581 Mechanical Base Fee MJB 12/21/200 $23.50 55581 Plumbing Fee MJB 12/21/200 $33.00 55581 Plumbing Base Fee MJB 12/21/200 $20.00 55581 EH Plan Review CEW 01/29/200 $50.00 55581 Planning Review Fee KS 01/30/200 $38.00 55581 Total $1,362.69 - es for conditions of this permit. 5 BLD2000 01317 Please refer to the following pages p rml 1 of CASE NOTES FOR BLD2000-01 31 7 CONDITIONS FOR BLD2000-01 31 7 1) The use, handling and storage of hazard u mat iaJs or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 2) Provisions for surface/subsurface drai jeontrol must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which i roposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work whichFyct your project. X 3) Proposed structureion thereof greater than 30" in height from g de e, must maintain a minimum of 5' setback from all property lines, easements and 10'from all County and State Road right of ways. X 4) The proposed project must be consistent w a applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program.X 5) All upland areas disturbed or new c ed y construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6) Water qu V`8� to be degraded to the detriment of the aquatic environment as a result of this project. X 7) Approve r dimensions and setbacks on submitted site plan. X 8) This structur s'not be used as an accessory living quarters unless applicant aquires the appropriate shoreline permits. X 9) Owner/Applicant acknowledges that a variance has been granted of 10' into the Mason County 10' setback which will allow placement of the structure 0' from the property line and ROW line. Under no circumstances shall any construction be located or placed encroaching within the ROW or on or over the property line. X BLD2000-01317 Please refer to the following pages for conditions of this permit. 2 of 5 10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be g anted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the 'Building ment prior to any further inspections being performed or approvals granted. X 11) In acc da a with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the stree or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. -inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contracto it to post the address on site prior to requesting inspections. X 12) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be chan ltered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site f he duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 13) The "approved" plot plan_Js required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be gr ted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour)will be charged and shall be collected by the Building Dep rtment prior to any further inspections being performed or approvals granted. X 14) In buildings of un y tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air from outsi in accordance with the Uniform Mechanical Code. X 15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior nstruction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If do ents are removed, approval will not be granted. In addition, a re-inspection fee of$47.00 per hour(minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 16) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the St Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy wo result in permit revocation. X 17) All changes to " pproved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance or re gu on, must be reviewed and approved by Mason County prior to construction. X .� BLD2000-01317 Please refer to the following pages for conditions of this permit. 3 of 5 18) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniflorm Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspectors be made prior to requesting additional inspections. X 19)• All pro ne tan must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks filled on site mus cated a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 oaUons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc), property line or easement. I aa pane tank is exposed to probable vehicular damage, protective bollards must be installed. X 20) Fuel piping be inspected after the installation of gas piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspectio est pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not used until the final inspection has been performed and approved by a Mason County building inspector. X 21) All property IiL shall be clearly identified at the time of foundation inspection. X 22) All building permits shall have a final inspection performed and approved by the Mason County uilding Department prior to permit expiration. The failure to request a filaatinspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant Mason County ordinances and building regulations. X 23) All permits exp a 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a perio exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder hayd prevented action from being taken. No more than one extension may be granted. X 24) 1997 UBC Cha er 17, Section 1701. In addition to the inspections required by UBC Section 108, the owner or the engineer or architect of record acting as the owner's agent all employ one or more special inspectors who shall provide inspections during construction on the types of work listed under UBC Section 1701. The special inspectors' duties & responsibilities shall be as specified in 1701.2 and 1701.3. X 25) New septic system will need to be installed and approved before final/temporary occupancy can be given. X BLD2000-01317 Please refer to the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commen d. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be o pied. OWNER OR AGENT: DATE: BLD2000-01317 Please refer to the following pages for conditions of this permit. 5 of 5 1 CG'.'C[*ETE MECHANICAL MOBILE HOME ' Footings-Setback 0A Si`.��wj date by , ,`� " � Ribbons date ' '-`� �'�t;�. by Gas Piping date by Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING FIRE DEPT. dat . ---1 7- 2eC4 by 41WA Ef Walls y date by date b PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date' -l-7 -76C,1 by date by Water Line FINAL INSPECTION date j- e71rj by j, ,QUA date �o& 6Z b r date by -2.0 ZOO l F Am P F4�Cs� Q SEt� A4,achcp Coa"ZTroA j�jo rc.E. P70e g 4 p loCp ApIOST pLoo,e_ L..EOEL_ CS►= ��s �A 20 e�T p/1{C ev 1 a V// AIV01101Z,:5 4 / snot oy�..,�Wo 1JZVz-' '' � �NK��i4a/K/Nh ��•",v�,—?�l r.��c/s /4s /��E.OED_ Nt:A / Awl,r/0,0 gL frE Bler-,kw T SrAie,s-f U /l D Z0 � I S tM MUST BE COMPLETED IN INK PERMIT NO.: r'LEASE PRESS HARD MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair(360)275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLIC T INFO MATION CONTRACTOR INFORMATION Owners Contractor Name Mail* Address Mailing Address City 1S State �LA Zip Code 'i t1l C, City State Zip Code Pho7e(`2CLL JeC' -215 70ther Ph.( VC, )",11 - Ph.( Other Ph.0 Lien/Title Holder Contractor Reg. # _ Address Expiration SEPTIC INFORMATION-Connect to New Septic Existing Septic >< Connect to Sewer System Name of Sewer System PARCEL INFORMATI N-12 digit Tax Parcel No. 'I fv 000lf Fire,District Legal Description �Z ' = f> caw I '' ��►� C.�- A Site Address(Please include street na e, street number and city) tom, Ki ,n >t' Directions to site �xkk1L1_'1 y �(;��' .2 M( -%S r�F Ld-., s r rc Is your property within 200' of the following: Body of Water (Name) Hez�D LAWAL Saltwater_><. Lake River/Creek Pond Wetland _Seasonal Runoff Stream Slopes or Bluffs LocatlPE OF JOB New Add AltRepair Other Use of Building on of Fixtures/Units 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Fuel Type: Electric Type of Fixture No. of Fixtures Fees LPG>C Natural Gas Heatpump Toilets t Type of Unit No. of Units Fees Bath Basins �_ Furnace Bath Tubs Heatpumps Showers �— Vent Fans Water Heater _ Propane Tank _ Laundry Wsher Gas Outlets Sinks Wood/Gas/Pellet Stove Dishwasher Direct Vent? Other �_ (A'rf wAMP— Other Other _ S- 5,AAA/OEM' Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-1 certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval„ / first obtaining approval. X Date � �, < c> X Date A -T FOR OFFICIAL USE BEYOND THIS POINT Accepted by Date Submittal Amount Due Receipt No. 1J Al2I'AiI iV�At:t Vi W< 1l+PRtJV [) EM1FIED' t 7fV[ft'E'Ic------ t 5 Building Department Occ Group Type Constr. Planning Department Other Other t EES . Permit Fee Site Inspection Plan Review Fee UFC Plan Review Fee Plumbing&Base Fee Other Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( ) Violation Fee TOTAL FEES J .00 NEW DECK AND HOOD CANA' STAIRWAY TO / BULKHEAD EXI5TING DEGK (OHM) (LE55 THAN 30' ABOVE 6RADE) 36" HANDRAIL it I HOT TUB DEGK - AT 5TAIRWAY� DN (F) (LESS THAN 30' 4 ABOVE GRADE) p _ b4 40 - o EXI5TIN6 RETAINING WALL o T T.. ...........::::::..':.:::::..::.:. .: : . _ o ::::::.:::::.. y •ya.:.:.:•• '• DS ..._,. .ice.... .'.'..:. . ADJACENT I RGK::':'::::':: .': .'.. 36 HIGH H ...... FfOUSE NEW RETAINING WALL 6AURDRAIL $s� EXISTING RESIDENCE NO WORK) ' ROOFLINE 3 • p 36" HANDRAIL 1,220 5F GOVERA6E I :::::= I A (INGL. OVERHAN65) HOUSE � DEGK ::...�:�:•::• — I I : ::: �: ::•: ' FOOTPRIN SIDE SETBACK LINE z NEW WOOD DEGK o I ( (HATGHED) 369 5F L I N 1,031 SF RAGE (INGL. OP I F flANG-5) EXI5TIN6 WOOD DECK R.O.W. 5ETBAGK • Q p Q � _ E— UP o LL �J 5'-0" 5'-0' 05 PL = 51.-' 05 P = — 51DE 5ETE34,K 51 AGK TO FON 24'-0" 10'-0" 30'-0" TO FDN EXISTING NO FENCE NEW WD FENCE TO MATCH EXI5TIN6 NEW A5PHALT DRIVEWAY -- - ----- �ATTSUN 5 . 6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT 12/13/00 FILE: C:\\WATTSUN5\\0032GARA.WS HOUSE ID: -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Site: 9421 State Route 106 Analyst: Union, WA 98528 Jurisdiction: ( ) - Utility: Homeowner: Doug Christensen House Type: Single Family 6523 NE My Way Floor Area: 500 ft2 Builder: Weather Data: Seattle, WA JU Climate Zone: 1 ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ The PROPOSED design *COMPLIES* with 1997 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 142 132 Btu/hr-F ENERGY BUDGET *** *** kWh/ft2-yr ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ REFERENCE DESIGN Reference Component Value X Area = UA ------------------------------------------------------------------------------ Floor U-0 . 041 500 20 . 5 Glazing @15% U-0. 650 75.0 48.8 Doors U-0. 390 20.0 7 . 8 AG Wall U-0.062 777 48 .2 Ceiling, Attic U-0. 036 70 2 .5 Ceiling, Vault U-0.034 430 14.6 Infiltration ACH-0.350 4000ft3( 25. 6) ---------------------------- Reference UA 142 . 4 -------------------------------------------------------------------------------- PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA ------------------------------------------------------------------------------ Floor R19 unvented Joist 16oc U-0.040 500 20.0 Glazing @16% **Andersen Clad window U-0. 320 81 .0 25 .9 Doors 2gl Half Lite Ins 1/4" , Clr U-0.310 20.0 6.2 AG Wall R13 STD Lap Wood U-0.082 771 63 . 2 Ceiling R30 blown Attic STD baffled U-0.036 70 2 .5 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 ATTSUN 5. 6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT 12/13/00 FILE: C:\\WATTSUN5\\0032GARA.WS HOUSE ID: R30 batt Vault vented 2x1® 24oc U-0.033 430 14 .2 Infiltration Standard Air Sealing ACH-0. 350 4000ft3 ( 25. 6) ---------------------------- Proposed UA 132 . 1 Struc Mass Light Frame, Sheetrock walls M- 3. 000 500 1500 -------------------------------------------------------------------------------- HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Gas Furnace Make: DEFAULT System Efficiency: 78 % Modified Efficiency: 0 % Design ACH: 0 . 60 Design Load(at 44F dt) : 7936 Btu/hr Duct Losses(% Dsn Load) : 0 Btu/hr( 0%) Total Load: 7936 Btu/hr System Size(Output) : 12000 Btu/hr ( 150%) Average Annual Heat: *** MBtu Annual Cost: $ *** Ventilation System: Integrated Spot & Whole House Cooling System: SEER: 0.0 (Ducted) Cooling Load(at 4F dt) : Btu/hr System Size(%Over) : tons(@125%) Annual Cool Requirement: kWh/yr Solar Access: Partially Shaded -------------------------------------------------------------------------------- PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area ------------------------------------------------- SUPPLY Attic or garage R- 8.0 100.0 ft2 RETURN Attic or garage R- 8.0 20 . 0 ft2 -------------------------------------------------------------------------------- ---- Page 2 MASON COUNTY PERMIT ASSISTANCE CENTER Mason County Bldg.111426 W.Cedar P.O.Box 186 Shelton,WA 98W (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 December 7, 2000 Doug Christensen 6523 NE My Way Bainbridge Island, WA, 98110 Re: BLD2000-01317 Dear applicant, Your plan for the building permit referenced above has been reviewed. This review letter contains only those comments related to the Building Department review and does not reflect any additional needs of the other county departments. Please review the following project data, and plan review comments. It is important that you then follow the instructions for re- submittal following the plan review comments. PROJECT DATA: Owner: Doug Christiansen 6523 NE My Way Bainbridge Is., WA, 98110 (206) 780-2957 Architect: David Vandervort 5135 Ballard Ave NW David Vandervort Architects AIA Seattle, WA, 98107 (206) 784-1614 fax: (206) 781-1911 Engineer: Paul A. Faget P.E. 2124 Third Ave., Suite 100 Swenson, Say, Faget Seattle, WA, 98121 (206)443-6212 fax: (206)443-4870 Code Editions: 1997 Uniform Building Code, WAC 51-40 1997 Uniform Plumbing Code, WAC 5146, 5147 1997 Uniform Mechanical Code, WAC 51-42 PLAN REVIEW COMMENTS: 1, The lateral analysis calculations are not clearly indicated. The engineer's lateral calculations do not indicate the lateral loads to be applied to each wall line at each floor level, nor are the lengths and locations of each shear wall indicated on either the plan sheets or the calculations packet. The plans specify that all walls shall be SW 1 unless otherwise noted, however without the calculations for each wall line indicating the required length of shear wall required, it is unknown how many feet of shear wall are required, nor is it known where hold downs or straps are to be located etc. Only one shear wall is labeled on the plan sheets, the front of the main level garage walls, and the accompanying shear wall schedule printed on the plan sheets does not match that of the one in the calculation packet. Please provide full lateral calculations indicating the lateral loads to be applied to each wall line, the location and length of each shear wall, the location of each hold down and/or strap as well as any other pertinent engineering requirement. Then, please be sure to clearly and accurately transfer all engineering requirements to the plan sheets. 2, The proposed plans contain concrete walls with heights exceeding 8'. All concrete walls exceeding 8' in height require an engineer's analysis. Please provide full engineering calculations and specifications for the specific concrete walls. 3, The proposed plan indicates a concrete retaining wall exceeding 30" in height located within the 5' minimum required sideyard setback. The plans must be revised to assure that no construction exceeding 30" in height will be located closer than 5' to any property line or easement, or a sideyard setback variance application must be submitted and approved prior to permit issuance. Please either revise the plans or obtain a variance. 4, The proposed plan indicates 4 propane tanks to be installed at the west side of the building. Please indicate the number and size of the proposed tanks to be installed. 5, The plans indicate the required fire resistive construction for the separation between the upper level and the garage, however, no separation is shown between the entry area and the stairs above, nor any from the entry area to the storage area below. Also required will be one hour fire resistive construction below the garage. The storage area building sections do not indicate any such fire resistive construction where they support members of the upper level or the garage level. When fire resistive construction is required, such as between the upper level and the garage and between the garage and the storage area, all structural members supporting such fire resistive separations must also be protected to the same degree. Please indicate on the plans how this required fire resistive construction will be constructed, including any necessary opening protectives. 6, The plans indicate several instances of structural steel. All structural welding must have special inspections as required by Uniform Building Code (UBC) section 1701. Enclosed is a special inspection authorization form that needs to be completed, identifying who will perform the required special inspections for the structural steel. Please complete, sign and return the authorization form to the Building Department prior to permit issuance. Please make the required corrections and/or clarifications and submit two sets of the plans showing the revisions, clearly marked on the sheets and noted with a cloud surrounding them or some other method of distinguishing the revisions. If only affected pages are re-submitted, arrangements should be made to remove the voided sheets and re-insert the new sheets into both building department copies of the submitted plans. Please detail all corrections and/or revisions in a transmittal letter, numbered in the same order as in the plan review letter to aid in a timely re-submittal review. Please be sure to reference the BLD number noted above to identify the file to which all re-submitted documents belong. Re-submitted plans are normally reviewed within 5 working days of the receipt of proper and complete revisions in our office. If re-submittal documents are incomplete or changes are made requiring additional review, an additional plan review fee may be charged at the rate of$47.00 per hour. Prior to re-submittal, please call the Plans Examining Department to make arrangements for a meeting if one is necessary, or if you have any questions regarding this review. You may contact me at (360) 427-9670 extension 551. Sincerely, Michael J Barth, C.B.O. Mason County Building Department Plans Examining wp/00-01317 cc:Paul A.Faget P.E. David Vandervort,AIA