Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2001-00060 Remodel and Dormers - BLD Permit / Conditions - 5/15/2001
Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 i RESIDENTIAL BUILDING PERMIT BLD2001-00060 OWNER: DOUG CHRISTENSEN CONTRACTOR: RECEIVED: 01/22/2001 SITE ADDRESS: 9421 E STATE ROUTE 106 UNION ISSUED: 05/15/2001 PARCEL NUMBER: 322355100012 EXPIRES: 11/15/2001 LEGAL DESCRIPTION: BROOK POINT TR 12 PROJECT DESCRIPTION: DIRECTIONS TO SITE: REMODEL MAIN FLOOR, ADD DORMERS TO UPPER FLOOR HWY 106, 3 MILES WEST OF TWANOH STATE PARK General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: 5N Type of Use: SF Insp. Area: No. of Bathrooms: 4 Occ. Group: R3 Lot Size: Deck: Type of Work: REM Fire Dist.: 6 No. of Stories: 2 Occ. Load: 5 Building:1,462 Valuation: $78,395 Building Height: 23 Occ. Status: Unknown Basement: Cvr Porch 164 Manufactured Home Information Setback Information Shoreline & Planning Information Make Length: Ft. Front: S 10.0 Ft. Shoreline: 15.0 Ft. Water Body: HOOD CANAL Rear: N 15.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: E 100.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: W 40.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty, Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KLW 01/22/200 $545.84 55470 Hosebibs 2 Furnace<100K 1 EH Plan Review CEW 01/31/200 $50.00 56301 Kitchen Sink 1 Gas Outlets 3 Planning Review Fee SLo 02/05/200 $38.00 56301 Laundry Tray 1 Ventilation Fan 5 Adjust Plan Check Fee MJB 03/15/200 $4.55 56301 Lavatories 4 Propane Stove 1 Building State Fee MJB 03/15/200 $4.50 56301 Showers 2 Dryer Vent 1 Building Permit Fee MJB 03/15/200 $846.75 56301 Water Closets (Toilets) 3 Mechanical Fee MJB 03/15/200 $121.60 56301 Water Heaters 1 Mechanical Base Fee MJB 03/15/200 $23.50 56301 Bath Tubs 1 Plumbing Fee MJB 03/15/200 $110.00 56301 Clothes Washer 1 Plumbing Base Fee MJB 03/15/200 $20.00 56301 Total $1,764.74 BLD2001-00060 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR AN BLD2001-00060 CONDITIONS FOR BLD2001-00060 1) This applicati sub' t to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) The use, h dlin and storage of hazardous aterials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason unty Fire Marshal. X 3) Provisions for surface/subsurface drainage o rol must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which affect your project. X 4) Proposed structur y portion thereof greater than 30" in height from gra a 'ne, must maintain a minimum of 5' setback from all property lines, easements and 10' from all County and State Road right of ways. X 5) All expansio of existing structure shall take place behind the 15 foot s or ine setback. X 6) Water quality is Vt be degraded to the detriment of the aquatic environment as a result of this project. X 7) All upland areas disturbed or newly cre d y construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 8) The proposed project must be consistent with al trc ble policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program.X 9) 1997 UBC Chapter 17, Section 1701. In addition to the inspections required by UBC Section 108, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors wh6 shall provide inspections during construction of the structural steel welding, during the pile drivi d during any epoxied bolt/hold down installations, or any other item as listed under UBC Section 1701.5. The special inspectors' tie & responsibilities shall be as specified in 1701.2 and 1701.3. X BLD2001-00060 Please refer to the following pages for conditions of this permit. 2 of 4 10) ;M approved plans a uired to a on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be gr ted addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the Building rtment prior to any further inspections being performed or approvals granted. X 11) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-in fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contractor f�I ost the address on site prior to requesting inspections. X i 12) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of tans on site p pp p t for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building g X 13) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be gr In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and shall be collected by the Buildin rtment prior to any further inspections being performed or approvals granted. X 14) In buildings of unusually ti onstruction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air from outside in dance with the Uniform Mechanical Code. X 15) Any changes in proposed construction shall be reviewed by the engineer of record and submitted in writing to the Mason County Building Department prior to construction. A ineering documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not b ranted. In addition, a re-inspection fee of$47.00 per hour(minimum 1 hour) will be charged and shall be collected by the Building Department pri to any further inspections being performed or approvals granted. X 16) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State "ashington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would suit in permit revocation. X 17) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance or r ul�, must be reviewed and approved by Mason County prior to construction. X BLD2001-00060 Please refer to the following pages for conditions of this permit. 3 of 4 18) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as a—m nded and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector be made prior to requesting additional inspections. X 19) Fuel piping shall be inspected after the installation of gas piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used until the final inspection has been performed and approved by a Mason County building inspector. X 20) All property lines shall be clearly identified at the time of foundation inspection. X 21) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-complian ith M on County ordinances and building regulations. X 22) All permits expire 180 da r permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a peri of exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holde a prevented action from being taken. No more than one extension may be granted. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is corn nced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before b i ding can b o upied. OWNER OR AGENT: DATE: BLD2001-00060 Please refer to the following pages for conditions of this permit. 4 of 4 i CONCRETE MECHANICAL MOBILE HOME Footings•Setback date by Ribbons date by Gas POV date by Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date I0'Z_ by date by FRAMING Walls date DEPT. date i O I b r L-) date by date ()Z by PLUMBING t OTHER Groundwork date by date by D.W.V. WALLBOARD A�114 G date by date 7-Z Z by Water Line FINAL INSP N date by date l� by 1 date by T7 - EPAMLAQ 4 O L aa) VzyXv PERMIT NO.: BLD MASON COUNTY BUILDING PERMIT APPLICATION - 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATION 11 Owner v Contractor Name7d (JE Jj7E>p,tnl t\Qct Mailin Address Mailing Address City . State Zip Code 98l((� City State Zip Code Phone Other Ph.(7& E 7- 6-AIS`i Ph.( Other Ph.( Lien/Title Holder Contractor Reg. # Address Expiration SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System Well Water System Name of Water System PARCEL INFORMATION-12 digit Tax Marcel No. / 51. Fire District Legal Description 4 i v Site Address(Please include street name, street number an city.) Directions to site H r,U IAA AY (O(41, 22 M 1.E f(AJF,sT cl fF t(, A Aly 51A TJE FAR. — Will timber be cut and sold in parcel preparation? (Yes -/ Is your property within 200' of the following: Body of Water (Name) flBDD [ I— Saltwater_ Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New Add Alt % Repair Other Use of Building c Describe Work o o or v to 11i1a roo No. of Bedrooms_2No. of Bathrooms SQUARE FOOTAGE-1st Flo r 00 2nd Floor 5a0 3rd Floor Loft Basement Deck Other sq. ft. Garage Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-1 certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. X Date X Date FOR OFFICIAL USE BEYOND THIS POINT Accepted by Date Submittal Amount Due Receipt No. DEPARTIVMENTAL. REVIEW: APPROVED DENIED CONDITION:co0Es Building Department pQ �o.r� eQ-el o,11t t- Occ Group 3 - Type Censtr. SiJ 3 15' Planning Department r Environmental Health Department Public Works Department I Fire Marshal valuation $ FEES ... . Building Permit Fee y b Site Inspection Plan Review Fee Sq5 S# 5 3 y UFC Plan Review Fee i1iPlumbing & Base Fee ' 30, O Public Works Review Fee Mechanical & Base Fee Other -� 0 Wood/Gas/Pellet Stove Fee Other Violation Fee Pre-Paid at Submittal .................................,......... TOTAL FEES 01/19/2001 16:53 FAX 360 427 7798 MASON CO PERMIT CTR 001 ! �~� FORM MUST BE COMPLETED IN INK PERMIT NO.' PLEASE PRESS BARD MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedari®.O.Box 196,Shelton,WA 98564 Shelton 360 427.9670 Belfair 340 275 4467 Omit 360 442.6269 Seattle 205 4644966 APPLICAXT INFORMATION CONTRACTOR I RMATIObfff—gM Owner Contractor Name 10 Z INEfC Maili Address Mailing Address City State JLZL Zip Code City State Zip Code Phone(j�, Other Ph.CJ2G j 54?-L55Tt Ph,C_ Other Ph.( _) Lien/Title Holder Contractor Reg. # Address Expiration 1 I SEPTIC INFORMATION-Connect to New Septic X Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION-12 digit Tax Parcel No. ZZ ! / 00011 --67CO Fire District Legal Description Lat,, 11. 17 , 13 c wka JLall, 5 c . Site Address(Please nclude street name,st eet number an cit btioit 1 Directions to site w 0 ux� a e 4 I' / I Is your property within 200' of the following:Body of Water(NamI) &OP l A HA I,,, Saltwater k Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New Add X Alt k Repair Other Use of Building Location of Fixturesi'Units 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MI`CHANICAL UNITS Fuel Type, Electric j Type of Fixture No, of Fixtures Fees LPG X Natural Gas Heatpump Toilets `3 T of Unit No. of Units Fees Bath Basins T 3 _ Furnace Bath Tubs 1 Heatpumps Showers 2 _ Vent Fans Water Heater I Propane Tank Laundry Wsher I Gas Outlets Sinks ' Wood/Gas/Pellet Stove I Dishwasher 1 Direct Vent? Y Other Other Other Other. Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTUREIUNIT. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENDED WITHIN 190 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK Is COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INsPHCTION. The owner or agent on owner's behaU,represents that the information provided is accurate and grants employees of Mason County access to the above descriped property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-]certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-[certify that I am currently registermd as a Contractor Registration Law RCW 1627 and am aware or the ordnance contractor in the State of Washington and that!am Mare of the ordinance requirements for which this permit Is issued and that all work will be done in 'equlrements regulating the work for which this permit is issued and all work conformance th o changes shall be made without first obtaining shall be done in conformance tnerewith. No changes shall be made without approval. first obtaining approval. X Date J X Date FOR OFFICIAL USE BEYOND THIS POINT Accepted by Date Submittal Amount Due Receipt No. :©��• ICI�fi4#�: RlTM� Building Department Ccc Gtoi Type Constr. _ Planning Department Cther �'. �.k Y k�� T.i M��.,i d!i'8i;�:.lx�i l.<o} ff:u i•2•�:. ^:S` fi � 'S T fJ' S:y(e � �i.� � X k i�:�:�Y�> :<2:1:<.rx.:� Y^ xv>i �� `%�)' YY yi •.2.<i�.?;'..y�.fY>�t n';S'%x•:1�:T;:j..�2x r� kY� ..�.::k..2�.:":�:..N!. <.�.e.if r.O.<>..r%..x Sn.�: 4.. Permit Fee ue inspeetion 1 Plan Review Fee UFC Plan Review Fee Plumbing S Base Fee Usher Me0anleal&Base Fee Other Wovd/Gas/Pe'let Stove Fee Pre-Paid at Submittal i } r Violation Pee TOTAL FEES 5 r • a Show the following on the site plan: Indicate direction (by N. S, E, W) in relation to plot plan => Lot Dimensions Existing Structures Neighboring Structures Proposed Structures Name of Streets, Roads W Driveways Septic Tanks/Drainfield Easements Shorelines, Streams, Rivers ADJACENT PROPERTY APPLICANTS PROPERTY ADJACENT PROPERTY 7—HavD �F-�? -A NAB . -AUDIT 10�5 H EAD i __ - ----� __--------I i L—— — - gT TDwvEWAIJ 51T CLAN 1 =sa.o, T N PLEASE ILLUSTRATE TOPOGRAPHY PROFILE IN SPACE PROVIDED BELOW trl-� 10(0 _?-/W � {� 10, 5V-T W44-- EM I ao < < 1 �-�xIsTNG i \ SITS � ��"IDNXIsT1N� � r I y� I171.Of ' MASON COUNTY PERMIT ASSISTANCE CENTER Mason County Bldg.Ill 426 W.Cedar P.O.Box 186 SheRon,WA 98W (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 February 26, 2001 Doug Christensen 6523 NE My Way Bainbridge Island, WA, 98110 Re: BLD2001-00060 Dear applicant, Your plan for the building permit referenced above is in the process of being reviewed. p gp Unfortunately, the review can not be completed until we receive all the information relevant to , the project as proposed. This letter reflects only those items that are necessary to continue the Building Department review, and does not contain the findings of the review, or note all of the corrections that may be necessary once the review is completed, nor does it address any needs of any other county department. Please review the following comments, and then follow the re- submittal directions that follow. PLAN REVIEW REQUIREMENT COMMENTS: 1, The shear wall lines in the engineer's calculations are not identified. The calculations indicate shear wall lines A,B,C,D & E, however, there is no diagram identifying which wall line is which. Please clarify the information. 2, The shear value indicated for SW-2 exceeds the allowable loads as established by UBC Table 23-II-I-1. 15/32 APA rated sheathing nailed with 8d nails at 4" o.c. to HF studs would allow a maximum shear load of 623 pounds per lineal foot, as opposed to 706 as specified within the shear wall schedule. In addition, with shear loads in excess of 350 pounds, a minimum single 3 inch member shall be used for the sill plate, unless anchor bolt values are halved, and for all studs receiving edge nailing. Where shear loads exceed 600 pounds per lineal foot, a minimum 3 inch sill plate is required regardless. Please clarify and/or correct the submitted information. J3, Shear wall 3 requires the use of 3 inch sill plate material, in addition to the 3 inch douglas fir studs specified. Please clarify and/or correct the submitted information. 4, It appears that several of the shear walls specified in the engineer's calculations exceed the allowable shear values of the specified shear wall type. The calculations indicate loads of Swa 1s 720 and 1920 pounds per lineal foot to be applied to shear wall types 2 and 3 respectively. This Qg"'Sop exceeds the shear loads allowable. Please see UBC Table 23-H-I-1, including the footnotes. to g" Please clarify and/or correct the submitted information 5, Several references have been made to epoxy installations. Any required anchor or hold down to be installed with epoxy shall be done with special inspection as required by the epoxy manufactures product evaluation report and UBC section 1701. If epoxy is to be used it will be necessary to complete a special inspection authorization form (enclosed), indicating who will perform the required special inspections. 6, The geo-technical engineer's report indicates that a "periferal footing" is to be installed, placed on pin piles, due to the soil liquefaction potential of the building site. The plans indicate that the new footing does not encompass the entire perimeter of the building. Please clarify with the geo-technical engineer if an entire perimeter foundation is required, or if the partial foundation as indicated on the plan sheets will satisfy the geo-technical engineer's requirements. If the geo-engineer's intentions are for a pile supported continuous foundation around the entire building, please revise the plans accordingly. If the geo-engineer is satisfied with the submitted design, please provide a statement from the geo-technical engineer specifically approving the proposed design. Please make the required corrections and/or clarifications and submit two sets of the plans showing the revisions, marked on the sheets and noted with a cloud surrounding them or some other method of distinguishing the revisions. If only affected pages are re-submitted, arrangements should be made to remove the voided sheets and re-insert the new sheets into both building department copies of the submitted plans. Please detail all corrections and/or revisions in a transmittal letter, numbered in the same order as in the plan review letter to aid in a timely re-submittal review. Please be sure to reference the BLD number noted above to identify the file to which all re-submitted documents belong. Re-submitted plans are normally reviewed within 5 working days of the receipt of proper and complete revisions in our office. If re-submittal documents are incomplete or changes are made requiring additional review, an additional plan review fee may be charged at the rate of$47.00 per hour. Prior to re-submittal, please call the Plans Examining Department to make arrangements for a meeting if one is necessary, or if you have any questions regarding this review. You may contact me at (360) 427-9670 extension 551. i erely, hael J B h, C.B.O. Mason County Building Department Plans Examining wp/01-00060 cc:David Vandervort Architects Spears Engineering&Technical Services MLA Engineering,pllc MLA Engineering, pllc Structural Design _ February 28, 2001 Mr. Mark Wierenga David Vandervort Architects 5135 Ballard Avenue Northwest Seattle, Washington 98107 Re: Mason County Plan Review Comments to BLD2001-00060,Christensen Residence Dear Mark: We have reviewed the plan review comments made by Michael Barth of the Mason County Building Department. Please review our responses and apply any appropriate revisions to the drawings. I. swA—E are noted in the calculation package on sheets F 11 and F 13. 2. According to the 1997 Uniform Building Code table 23-11-I-1, footnote 1, second paragraph, reads: Allowable shear values for nails in framing members of other species set forth in Division III, Part III,shall be calculated for all other grades by multiplying the shear capacities for nails in Structural I by the following factors: 0.82 for species with specific gravity greater than or equal to 0.42 but less than 0.49,and 0.65 for species with a specific gravity less than 0.42. s�,, Per the 1997 National Design Specification for Wood Construction the Hem-Fir species has a 5 r F, o AS specific gravity of 0.43. Therefore we reduced the Structural I Panel Grade values for 15/32" 15�3a APA Rlfftn sheathing, nailed with 8d commons nails spaced at 4"on center at the edges by 0.82; 43 0#/ft x 1 side x 0.82 =353#/ft. 15/32"sheathing at each side, nailed with 8d commons nails spaced at 4" Noy cnR��T.� on center at the edges,with vertical joints staggered, would have 706#/ft. Any conflicting notes regarding the use of 3x plates should be disregarded. It is our opinion that all shear walls, exceptZ_, the P 1-4B(S W 1)shear wall, should have 3x sill plates. P"Asc f vo.wre 3. Per our calculation package sheet L4, note 11 calls for DF 3x studs at P2-2B(SW3). A similar �thA D" Skl .ScaYa,c� shear wall table is also on sheet S 1.0 of the permit drawings. armN 4. Per the 1997 Uniform Building Code table 23-R-I-1 swD, first floor, on sheet L2 of the calculation Fovrniare package is 2%overstressed,which is acceptable to us. swA, first floor, on sheet L2 of the 1I DUtic Ir calculation package should have its shear length, !v,revised to 4.5'. The unit shear in the wall then VA OF 3x Sw a �s should calculate to: 7682#/4.5ft= 1707#/ft. ST�as a� 5. Epoxy Grout is noted to be installed per the manufacturer on S3.0 under LEVoxy Grout and should 4° 1 be added to Special Inspection also or.S3.0. STRJ( 1 du�Y" 6. We understand that the Geotechnical Engineer is reviewing the permit plans and will forward his Samos A..n comments to you when he completes his review. 5,,,. P..,�S Aga SERrH*Te Please call, (206)264-2727, if you have questions. Rea�,aEMFars, Sincerely, E"`°' M'K'g` 3 x I., MLA Engineering,pllc ew P.E. 1411 Fourth Ave.,Suite 1506 Af1.Aengr@=w oom Tel:206.264.2727 Seattle, WA 96101 Far:206.264.4835