Loading...
HomeMy WebLinkAboutBLD2008-00041 SFR - BLD Permit / Conditions - 3/31/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 too RESIDENTIAL BUILDING PERMIT BLD2008-00041 OWNER: MARTY REYNOLDS RECEIVED: 1/11/2008 CONTRACTOR: PARADISE BUILDERS 360-731-1399 LICENSE: PARADB1108M7 EXP: 8/21/2008 ISSUED: 3/31/2008 SITE ADDRESS: 11 E BLACKWELL ST ALLYN EXPIRES: 9/30/2008 PARCEL NUMBER: 122205052001 LEGAL DESCRIPTION: ALLYN BLK: 52 LOT: 1-2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR LAKELAND DR, L TO BLACKWELL. SITE ON L General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr. VB Type of Use: SF Insp. Area: No. of Bathrooms: 2 Occ. Group: R-3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,600 Garage-Attached 308 Valuation: Building Height: Occ. Status: Primary Basement: COVPORCH 40 Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft. Front: E 15.0 Ft. Shoreline: Ft. Water Body: NONE Rear: W 30.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: S 8.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: N 5.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KS 1/11/2008 $762.42 S12008000 Hosebibs 3 Ventilation Fan 4 Planning Review Fee KS 1/11/2008 $190.00 S12008000 Kitchen Sink 1 Dryer Vent 1 Address Fee BLF 1/15/2008 $162.00 S22008000 Lavatories 3 Building State Fee ARC 1/16/2008 $4.50 S22008000 Showers 1 Building Permit Fee ARC 1/16/2008 $1,172.95 S22008000 Water Closets (Toilets) 3 Mechanical Fee ARC 1/16/2008 $54.35 S2200800o Water Heaters 1 Mechanical Base Fee ARC 1/16/2008 $26.60 S22008000 Bath Tubs 1 Plumbing Fee ARC 1/16/2008 $103.81 S220080oo Clothes Washer 1 Plumbing Base Fee ARC 1/16/2008 $23.10 s22oos000 EH Plan Review TW 3/31/2008 51o0.00 S22008000 Water Adequacy Plan Review TW 3/31/2008 $100.00 S22008000 Total $2,699.73 BLD2008-00041 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2008-00041 CONDITIONS FOR BLD2008-00041 1) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X f!—� 2) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in perm i .®vpcation. X a 3) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 4) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged-and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 5) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building InspectoL31hall be made prior to requesting additional inspections. X 6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with MasQa—C?unty ordinances and building regulations. � .1v 7) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roa connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X t�. BLD2008-00041 Please referto the following pages for conditions of this permit. 2 Of 5 C�) •Landings,and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approve Site Plan" to ensure these structures are shown and meet the setback conditions listed. X � 9) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 11) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder ve prevented action from being taken. No more than one extension may be granted. X 12) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removalI f approved documents will result in failure of required building inspections. X �^ 13) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 14) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X �� 15) All property lines shall be clearly identified at the time of foundation inspection. X 16) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-66�2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 17) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accorda ith the applicable provisions of this section and the manufacturer's installation instructions. X BLD2008-00041 Please referto the following pages for conditions of this permit. 3 of 5 18) Per 2003 IRC - SECTION 1609 - WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the ,minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 -BASICND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. ,X z 19) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 4y 20) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. `NOTE if Stormwater Management option "A" was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is nowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 21) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window (Max U-Factor):0.35, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the undersidazif the roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X 22) OWNER MUST SHOW PROOF OF WELL LOG AND SATISFACTORY WATER SAMPLE PRIOR TO TEMPORARY/PERMANENT OCCUPANCY OF THE RESIDENCE. X � 23) Prior to final approval, all upland areas disturbed or n:w�Iated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 24) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project BLD2008-00041 Please referto the following pages for conditions of this permit 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection. The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: _��- % DATE: BLD2008-00041 Please refer to the following pages for conditions of this permit. 5 of 5 o 'CONCRETE MECHANICAL MANUFACTURED HOME m rn outings SSetbac Gas PipingB� v` Ribbons Z 90 O nterio(Date By interior-Date By Date B O `�/ `�/o /�l6lt�l Y r A Exterior Date By Exterior-Date B Set-up N Point Load I Isolated Footings INSULATION Date By BG!SLAB INSULATION ic Date BY Data By FIRE DEPARTMENT > Foundation Walla Floors `Q Date By Date By Date SAW DECKS FRAMING Walls Date By Date Tj - B y2ejA Data _ BY PROPANE TANKS PLUMBING Vault Date By Date By OTHER �~ Groundwork Attic 42 _.....,....,._MA, Dale B a Type. Date BY Date By MW.V DRYWALL Type- Int.Brace Wall Date By Date . �Q. B Date By r v Water Linre�,' > Fire Seperation FIN '' 6 Y p Date r/ Q� B f Date By Da a O Pass or Request Inspect. c s Type of Insp. Fail Date Date Done By Comments oQ CD rr� o A-07 CCD A L tYwVl0k,Bi, Kc4 1YJ1T/� 8 f=raxyte— ctisS a y 0 s Ul 2•z�v d2���v 0