HomeMy WebLinkAboutBLD2009-00546 SFR - BLD Permit / Conditions - 8/18/2009 Inspection Line(360)127-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360 427-9670,ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
11010 Shelton,WA 98584
RESIDENTIAL BUILDING PERMIT BLD2009-00546
OWNER: WILBUR MENERAY RECEIVED: 7/6/2009
CONTRACTOR: LICENSE: EXP: ISSUED: 8/18/2009
SITE ADDRESS: 961 E TIMBER TIDES DR UNION EXPIRES: 5/2/2010
PARCEL NUMBER: 322357590110
LEGAL DESCRIPTION: TR 11 OF S 1/210-213 EX S 27/125 LOT: 1 OF SP#1019 S 32/206
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
RESIDENCE N 13TH TO BROCKDALE TO MCREAVY RIGHT ON DALBY RD RIGHT ON
106 RIGHT ON TIMBER TIDES PROPERTY IS ON LEFTAT 961
General Information Construction&Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R3 Lot Size: Deck: 461
Type of Work: NEW Fire Dist.: No. of Stories: Occ. Load: Building:1,732
Valuation: Building Height: Occ. Status: Primary Basement:1,710 cov entry 95
Manufactured Home Information Setback Information Shoreline& Planning Information
Make: Length: Ft. Front: E 11.0 Ft. Shoreline: Ft. Water Body:
Rear: W 33.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Shoreline Desig.: Not Applicable
Side 1: S 73.0 Ft.
Year: Serial No.: Side 2: N 579.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Dishwasher 1 Exhaust Hood 1 Plan Check Fee TW 7/6/2009 $1,526.82 S12009000
Grease Traps 4 Exhaust Hood 1 EH Plan Review TW 7/6/2009 $103.00 S12009000
Kitchen Sink 1 Furnace<100K 1 Water Adequacy Plan Review TW 7/6/2009 $103.00 Si2bb9o00
Lavatories 3 Gas Outlets 3 Planning Review Fee TW 7/6/2009 $205.00 S12009000
Showers 3 Propane Tank 1 Building State Fee DLC 8/4/2009 $4.50 si2bb bb
Water Closets (Toilets) 3 Ventilation Fan 4 Building Permit Fee DLC 8/4/2009 $2,348.95 si2oos000
Water Heaters 1 Dryer Vent 1 Mechanical Permit Fee DLC 8/4/2009 $168.90 tinowb-o
Bath Tubs 1 Mechanical Base Fee DLC 8/4/2009 $28.50 S12009000
Clothes Washer 1 Plumbing Permit Fee DLC 8/4/2009 $156.60 S12009000
A� bin C 8/4/2009 $24.7 12009 -
/ P ing Permit Fee DLC /2009 8.70 S1 09000
I yt 1� Plumbing Base Fee DLC 11/4/2009 $12.40 S12009000
C/i $4,691.07 _ —
l
BLD2009-00546 ���+�� Please referto the following pages for conditions of this permit. 1 of 5
Inspection in
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
Shelton,WA 98584
olo
RESIDENTIAL BUILDING PERMIT BLD2009-00546
OWNER: WILBUR MENERAY RECEIVED: 7/6/2009
CONTRACTOR: LICENSE: EXP: ISSUED: 8/18/2009
SITE ADDRESS: 961 E TIMBER TIDES DR UNION EXPIRES: 2/18/2010
PARCEL NUMBER: 322357590110
LEGAL DESCRIPTION: TR 11 OF S 1/210-213 EX S 27/125 LOT: 1 OF SP#1019 S 32/206
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
RESIDENCE N 13TH TO BROCKDALE TO MCREAVY RIGHT ON DALBY RD RIGHT ON
106 RIGHT ON TIMBER TIDES PROPERTY IS ON LEFTAT 961
General Information Construction&Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: VB
Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R3 Lot Size: Deck: 461
Type of Work: NEW Fire Dist.: No. of Stories: Occ. Load: Building:1,732
Valuation: Building Height: Occ. Status: Primary Basement:1,710 cov entry 95
Manufactured Home Information Setback Information Shoreline&Planning Information
Make: Length: Ft. Front: E 11.0 Ft. Shoreline: Ft. Water Body:
Rear: W 33.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: S 73.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: N 579.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Dishwasher 1 Exhaust Hood 1 Plan Check Fee TW 7/6/2009 $1,526.82 S12009000
Grease Traps 4 Exhaust Hood 1 EH Plan Review TW 7/6/2009 $103.00 Si2009000
Kitchen Sink 1 Furnace<100K 1 Water Adequacy Plan Review TW 7/6/2009 $103.00 §12009000
Lavatories 3 Gas Outlets 3 Planning Review Fee TW 7/6/2009 $205.00 S12009000
Showers 3 Propane Tank 1 Building State Fee DLC 8/4/2009 $4.50 S1P009000
Water Closets (Toilets) 3 Ventilation Fan 4 Building Permit Fee DLC 8/4/2009 $2,348.95 S12009000
Water Heaters 1 Dryer Vent 1 Mechanical Permit Fee DLC 8/4/2009 $168.90 Si200900o
Bath Tubs 1 Mechanical Base Fee DLC 8/4/2009 $28.50 S12009000
Clothes Washer 1 Plumbing Permit Fee DLC 8/4/2009 $156.60 S12009000
Plumbing Base Fee DLC 8/4/2009 $24.70 S12009000
Total $4,669.97
BLD2009-00546 Please referto the following pages for conditions of this permit. 1 of 5
CASE NOTES FOR
BLD2009-00546
CONDITIONS FOR
BLD2009-00546
1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X "1
2) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. All
applicable recommendations and specifications shall be applied to the development on this site. Any deviation requires stamped written approval from the
registered design professional responsible for the report/assessment, and may require special inspection by same. Structures and/or land modifications
(grading, cuts, fills, etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment shall
remain attached to the approved building plans.
X�/
3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0 The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department 'or to any further inspections being performed or approvals granted.
X �
5) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
X removal documents will result in failure of required building inspections.
7) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X •� �
BLD2009-00546 Please refer to the following pages for conditions of this permit. 2 of 5
8) Washington State Energy Code Compliance has been approved using the following:
Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors
(Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab
Insulation R-10.
* Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the
underside of4he roof sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation.
X�
9) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609
BASIC WIND PEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH.
X
10) Per IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in
accordance with the applicable provisions of this section and the manufacturer's installation instructions.
X
11) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement,
inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the
owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel
prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes
an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are
responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system
of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of
the building permit the owner/agent/contractor is agkp6wledging that all components of the stormwater management system have been installed as
approved on the stormwater site plan. X C
12) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or
more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design
professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17.
Special inspection reports shall be submitted to the Mason County Building Department, PO Box 186, Shelton WA 98584 and available for inspection.
Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy
inspections.
SPECIAL INSPECTIONS SHALL BE REQUIRED FOR FIELD/SITE PERFORMED WELDING. As noted on the approved building plans all welding will be
performed in a certified welding shop and shall not require a special inspection as noted above.
X 4I %
13) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
charged hall be collected by the Building Department prior to any further inspections being performed or approvals granted.
BLD2009-00546 Please referto the following pages for conditions of this permit. 3 of 5
i14). All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X
15) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X f,�
16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
X k
17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
X spec��l be made prior to requesting additional inspections.
18) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must
meet the installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks.
X G �
19) All property lines shall be clearly identified at the time of foundation inspection. X��
20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X 46tl
21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
(old �nted action from being taken. No more than one extension may be granted.
BLD2009-00546 Please referto the following pages for conditionsofthis permit. 4 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
worts is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
Ole -110e
OWN ER OR AGENT: DATE
BLD2009-00546 Please referto the following pages for conditions of this permit. 5 of 5
TRACT 10
TIMBER TIDES DRIVE EASEMENT
ELEV.IW' / �1 AS 8NOUN ON SURVEY 9K.I PAGES 210-213
_ ELEV.200'
v v ELEV.220' ELEV.210
M0ID0'
� , 1
� 1 /
1 TW.
TANKS
2SETBACK LBE i e LOT 1 f
p
GRAVEL-D'�"E SHORT PLAT f �
1 uELL � e f 1 N0. 101.,
P TRACT 11 1 Q
11 LOT 2 �f `
(PARCEL NO. 32235-15-90111) - \` (PARGEL NO. 32235-15-W110)
` EXIBTM DRAIWIELD / LJ TANG
`\ AND RESERVE
\\ 20'SIDE YARD /��� / �� \ NEW RES U_t
\ SETBACK LSE fi������ \ O�EXISTIhYs FOUNDATION
\
----------------
3k3k8'FFU_TRATION TRENCH FOR T}E 120D0'
e DOUN5e rs_BILLED.✓1-v,-v DIA sMoon I ♦ GEOTECNNICAL REPORT DONE BY MORTA EWGINEERINCs t TESTIWS
CLEAN DRAM ROCK 4 C-Ct L.ETELY
WRAPPED IN GEOTEXTILE FILTER FABRIC REVIEWED a APPROVED BY MASON COUNTY GE02OOc3-00031
10'REAR YARD SETBACK
L*E OBTAMn>BY VARIANCE ` TO HWY. 106
DDR2009-00050
TRACT 12 PARCEL No.:
SEE SITE PLAN
LEGAL DESCRIPTION:
TR 11 OF S 1/210-213 EX S 21A25
APPROVED LOT: I OF SP 01019 S 3212m6
LOT: 2 OF SP 0101'3 6 32/206
. „ ,, �. � Site Plan � � ��
JJN' �•OUNTY DAD F LANNIN'G SITE ADDRESS:
Scale: I" = 60'-0" "= 961 E. Timber Tides Dr.
..1.. A-AN REQUIRED TO BE ON SITE `
?_s SUBJECT TO APPROVAL r� NCI
}1 Union, Washington
T� `
Structural Design Notes
1. The 2003 International Building Code applies along with local Mason County
Feld testing of concrete See Detail A building codes. If there is a difference between the IBC and the County codes
n9 the more stringent building code applies.
compressive strength
using a Schmidt Hammer 2 The stniture shall be designed to withstand an earthquake event in the Seismic
T3100 psi Zone III area.
12 0' 3. A hand-held Schmidt Hammer was used to test the in-place compressive
ta6 Sae De A strength of the existing concrete foundation with compressive strengths
14_0' of 3000 psi or greater as shown in blue in this drawing. 3000 psi is considered
to be adequate for continued construction of the building using the existing
i'-----------------
1$-10 1/2' tp i i----------------- LI
3000 Ili concrete foundation.
' r-------------------------+ r------------------ 4. A hand-held net was used to determine if there was rebar in the concrete
-----------
1 , -------------------------1 r------------------ magnet
`m ' -------------------------' '------- ----- with initial results indicating that rebar is pressent. It is recommended that a
-----------
' -------------------------T '-------=----____=
__ 1 L t more sophisticated magnetometer be used to verfify the existing of rebar and
,� ------------------------t - --- - -------'- -----------------
� -------------� � -------- ----� �-------------------------� �------------------ .,- its spacing,if possible.
01 r--------------------____� '-------------_________---�'-------- -----
to 1 1 t 1------------------
-------------------------' L-------------- 1 ------_----____-- 5. The fast floor structural drawing as shown provides a very open daylight
--------------------- - ------------
--------------
2� - t 1 � t'-------"--"--'--"-----' I- basement basemenrt area,but does require the use of up to 18 inch deep g u am beam
--------- --------- '--------------------- r==1-�'--• _C--1-L�-.----------------
-------------------------t - - - --r 1-- ---------------- T-11" which could reduce headroom and may increase the cost of the building.
.
-------------------------' ---- - - - y-- -- - -- - L-------------
--- -----_ ; `---------- ------------- t~-= ___________________~ 'i i --------------- floor bearins with bearing walls consisting of 2"x 6'studs spaced 6'
ri ----------------------�_t r___________________--__Z3-L==___-- --=-�-r-- ------------- on-center and sheath both sides of all bearing walls with 5/8"gypsum
----------------------''-' r----------------------- 4_____'-____ _---____---_' 1 _—___------ -------------- board. Secure perimeter with standard gypsum board screws at 6'on
I t t t 1 1-----------------
-------------------------t c-==-=_ _____ ____-_-- -+ F----- ------------------J 1----------------- N center and 4'on--center in the field.
------------ --------- --------------
-------------------------� �------------------------� t------------ , ---------------
---_- ---------_ ;_____---- T----t---- it --_- -- -----------
t 7. For maximum structural integrity d is recommended that all bearing walls on
----------------------- t ---- - --- ----� '--------------------------} '-------=---------
------------------------, �___------ y ,--------------------------, ,----------------- ____________= both the basement and first floor line up above each other to ensure a positive
load path from the roof on dawn through the trusses,the first floor bearing walls,
r------- ------------ -- - -- - --
r i --------------
----------t , t 1 t r------------------� 1_______________ and,fin hg ng basement walls and into the 18"wide perimeter
--- 1 '--------------------------J L-----------------
---- ------------------
--- ---------------------+ r-------------------------� 1---------
C
---------t ------ eflOr COrxxete footings.
8. Existing l 2'diameter anchor bolts are spaced 4'on-ceriter in the existing
--------------------�_-- +--------------------- concrete foundation both at the lower level on the north side and at the upper
level on the south side of the foundation.
Existing ------------ -==i=�-z-i=====________________
2 high concrete =--=--------------------' '-------------------''-__ 3�00 S 9. The existing concrete perimeter footings are 16'wide x 6'deepwhich appear
---------------t r----------------------
ste�ll _____ t i _ to be adequate for the construction of a two story residence consisting of a
----------------
3100 i ' r4- daylight basement and a first floor. If a second floor is planned then further
Ps ---------•--------------' L------------------------ structural analysiswill be required to verifythat this additional floor can be
6' ------------------------t -------------------------
t ad ately supported.
------------------------i L--====_____-- ----------
10. Simpson Strong- ie such as HD1 incorporat i o
------------------------, F_________-- the structural design so that wind loads and earthquake loads as specified
-------------
D21811 A '------------
r- in the 2003 IBC can be adequately resisted.
--t -----------------------
11. Adetailed structural design analysis shall be prepared to resist wind and
------------------------' r________-_-_-_-_-_-_-_-----_-_-_-_- V/ earthquake forces which will incorporate Simpson Strong-Tie hold-downs
------------------------i ------------------------ �r,
and metal straps.
----------=-------------' L------------------------ .�
------------------------t, ------------------------ rr E1�
-�.� j`+ r � I, Y 12 Poor foists shown in this design drawing example are Boise Cascade
------------------------ r__________________ ---- �` �" Series 650/11.875 and have been designed to carry 60 pounds r
-------- ,I � r .+ � 9 rY P� per
square foot(pso live loads(LL)and 25 psf dead loads(DL).
24-2" 13. Refer to the attached structural calculations for details.
14. If you have any questions regarding this conceptual shictural design for
supporting the first floor,do not hesitate to call me at(800)590-0958.
3000 psi
15. The final structural analysis and design will be prepared once the final
architectural design has been chosen by the home owners.
WASx� �` Conceptual Structural Design for Residence at
I Lot 1 of Tract 11 on Timber Tides Dr.
�z o �merit C),SW 1/4,SE 1/4 of S35,T22N
ti
WM
Prepared for. Bill Meneray
7314 Zimpel St
New Orleans,LA 70118
R 30758 504 861-8457
O,cfi�FC,fSfER� 'j Prepared by Mona Engineering and Testing
1/9'=1 ft '110NAL P 0.Box 250,Ocean Shores,WA 98569
(800)590-0958,(360)289-9682fax
0 4' 8' 12 16, = nirEs ,ry by:Nov.16,2004 Designed' SPM Sheet 1 of 1
- VS KJ
MASON COUNTY PERMIT NO. IL—V 2CO
BUILDING PERMIT APPLICATION 00 t4(o
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner W1 I bt,).Y" e- Company Name
Mailing Address 00 LOY. (2110 Mailing Address
City Unto State Zip Code 2. City State Zip Code
Phone50y'-4q1-9352 Other Ph.L:� -LMO-1139 Phone Other Ph.
Lien/Title Holder Contractor Reg.# Exp.
E mail address E Mail Address
Drivers Lic.# DOB Drivers Lic. # DOB
SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well 4-_ Sewer System Name of Sewer System
PARCEL INFORMATION - 12 DN'Llo - 2-1-3
Parcel No. n :� • 0 10 Fire District
Legal Description �f 5 EX S 2-11125 Lot t of- 5 * 101 2
Site Address (Please include street name street number and city) bl E 'ri mbar -rues Pr tug iern
Directions to site h1 o f=�roc,kLtc (c 4V N�� e6.v i h�- or b Rd hit' o+-. IOb
on e C>eo ea^hi 'I Z
Will fimber be cut and sold in parcel preparation?Yes/(o
Is property within 200'of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs> 15%
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No
TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑
Use of Building describe Work or) eyi:jflr
No. of Bedrooms No. of Bathrooms -3 Square Footage- 1st Floor 1. 52- 2nd Floor
3rd Floor Basement Deck _Covered Deck Other Sq. ft.
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length.�idt Serial No. .No. of Bedrooms-No. of Bathrooms
Type of Heat / eft PPase Price $ Replacement Unit? Yes/ No
Installer Name -Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all
the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work
proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or
agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY
MEANS OFAPROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
Xr,..� .� Date: _
Owner/Owners Representative/Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT Accepted b7:�-t< 1"` Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Planning Department Pro
Environmental Health Department
Fire Marshal
FEES
Building Permit Fee jF e Site Inspection
Plan Review Fee /S 2w. EH Review Fee
Plumbing & Base Fee -&d ? Plannin Review Fee
Mechanical & Base fee lep4 0 Sa Other
Wood /Gas/ Pellet Stove Fee State Fee
Violation Fee l Pre-Paid at Submittal
Valuation $ TOTAL FEES
dc�
� . -
6
y ?—L,
I-
v
S l LeY
Cu,
PERMIT NO.
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFORMA ION CONTRACTOR INFORMATION
Owner + 1 VXLt w , "'� � "'r ' ' Company Name
Mailing Add ress X WE 4 Mailing Address
City !)► M State LL) Zip Code �-` City Mate Zip Code
Phone - -4q1-9 Other Ph= `'t`9y-11:�`i Phone Other Ph.
Lien/Title Holder Contractor Reg.U Exp.
E mail address E Mail Address
Drivers Lic.# DOB I Drivers Lic.# DOB
SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System
Name of Sewer System
PARCEL INFORMATION - 12 Digit Parcel No. Fire District
Legal Description /oiq ,.-) :11./'1-U(o
Site Address (Please include street name, street number a d city) '34:4 E Tiryiber —rije5r. io,
Directions to site t, 1 4-v 'f0 °'" On cr, ck
qn -ri, A e� i • 9 b
Is property within 200'of Saltwater. Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs > 15%
TYPE OF JOB - New Add Alt Repair Other Use of Building
Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:ElectriQ LPQ _ Natural Gas_ Heat Pump_
Toilets Type of Unit No. of Units Fees
Bathroom Sink Furnace /�—
Bath Tubs Heatpumps
Showers �' Spot Vent Fan
Water Heater Propane Tank /
Clothes Washer + Gas Outlets
Kithen Sinks 1 Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
CWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION.
X �.kl�.a.� Date: l I
Owner/Owners Represen five Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by: Planning Pd Ck# Date Bld Pd Receipt No.
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Occ Group—Type Constr.
Planning Department
Environmental Health Department
FEES
Plumbing & Base Fee Site Ins ection
Mechanical & Base fee UFC Plan Review Fee
Wood /Gas/ Pellet Stove Fee Other
Violation Fee TOTAL FEES
Name W I I bur M)U) r&,y Parcel# 32�-3 S"1 S - 9 0 j�0 BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area All dimensions in feet
Buildings X = 2bbb
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = ,�3� Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas) $$5
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for
review and inspection as may be required.
X v caner gent/Contractor(circle one)Date: 7 D�
If the Total Impervious Surface Are s GREATER THAN 2000 Square Feet, please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name W ` b I'`t1 WO' y Parcel# 32.2-3 S -75' 90 1 1 C) BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
hqnL/www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SffE
A) X The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
Mail:P 0 Box 1850,Shelton WA 98584
Physical:415 N 6th St,Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone: (360)-427-9670 EXT. 352
Mail:P 0 Box 1666,Shelton WA 98584
Physical:426 W Cedar St,Shelton WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X �� wne Agent/Contractor(circle one)Date: 71(, f D 9
Page 2 of 2
GOUDA
MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
Mason County Bldg. III, 426 West Cedar Street
;- PO Box 186, Shelton, WA 98584
www.co.masonma.us Shelton (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269
August 4, 2009
Wilbur&Jane Meneray
PO Box 664
Union, WA 98592
Re Building Permit Number: BLD2009-00546 Construct a dwelling on an existing foundation
system
Dear Mr. &Mrs. Meneray,
Thank you for submitting the building permit application referenced above. In order to complete
the building department review additional information will be needed which is listed below.
PLAN REVIEW REQUIREMENT COMMENTS:
1. The building plans specify that an existing foundation system will be used to support the proposed
structure. Referencing a site inspection performed in March 1996 by a Mason County Building
inspector the report states the following, "little or no reinforcement in wall,rebar is sticking out of
wall in some location. Walls are up to eight feet in height. Wall does not meet minimum code. If
it is to be used the Building Department would require the inspection and recommendation by a
structural Engineer." The building plans reference the existing foundation in details S3 on sheet
S 1 indicating that Morta engineering has certified the foundation without reinforcement. Since the
existing foundation system does not conform to existing code requirements a foundation design
shall be required. The design will need to address the proposed structure being constructed on the
foundation and be prepared by a Washington State licensed design professional.
2. The building plans propose welding on-site in order to make proper connections to structural
members. A special inspector certified to perform welding inspections shall be required to verify
that welding is performed in accordance to design specifications. Please make arrangements to
complete the Special Inspection Authorization form enclosed.
3. Compliance to the prescriptive option of the 2006 Washington State Energy Code (WSEC)
includes installation of R-10 slab insulation along the perimeter where concrete walls are less than
24-inches below grade. Building plans reference R-5 insulation vertically along the perimeter and
R-10 slab insulation horizontally. Please verify WSEC proposed compliance.
4. The window located in the bedroom located in the basement specifies a horizontal slider window
with dimensions 4630. Based upon information available to our office the window may not
comply with minimum egress requirements including min 5-sq. ft. net open able area and sill
height not to exceed 44-inches above the finished floor. Please verify code compliance.
When you have compiled the requested information please submit it to the Mason County Building
Department, attention D. Coker. Please respond to comments, in writing, in the order listed. Revisions,
required as a result of this letter must be transferred onto proposed building plans. Where required,please
return two sets of revised plans and documents along with two sets of calculations. If you have questions
please contact me at(360) 427-9670 ext. 510 or via e-mail at: dlc@co.mason.wa.us
Sincerely,
Debbera Coker
Mason County Building Department
Plans Examiner
Word/BLD2009-00546
cc: Foster& Williams, Architects, PO Box 102, Shelton, Wa 98584/ E-mail: mail(a,fosterwilliams.com
/FAX: 360.426.2926