Loading...
HomeMy WebLinkAboutBLD2021-00633 SFR - BLD Application - 4/29/2021 MASON COUNTY COMMUNITY SERVICES Permit No: 162O'0(-nn(433 PERMIT ASSISTANCE CENTER: I •BUILDING•PLANNJNG•PUBLIC HEALTH-FJRElob4RSHA EE E'V D 615 W.Alder Street,Shelton,WA 98584 •. Phone Shelton.(360)427--9670 ext.352-Fax.(360)427-7798 Ph I R 11212 Belfair.(360)275-4467-Phone Elma:(360)482-5269 B U I L D � �j ';� (4ii 615 W. Alder Street BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: J&J DEVELOPMENT LLC NAME: J&J DEVELOPMENT LLC MAILING ADDRESS:PO BOX 623 MAILING ADDRESS:PO BOX 623 CITY: BURLEY STATE:WA ZIP:98322 PHONE#I: 253.2omis CITY: BURLEY STATE: WA ZIP: 98322 PHONE#2: PHONE: 253-208-8136 CELL: EMAIL: sngio@cedadandlorestmources.com EMAIL: info(a)cedarlandforestresources.com L&I REG#JJDEVJD852OW EXP. 12/6/21 PRIMARY CONTACT: OWNER CONTRACTOR❑OTHER❑ NAME JOE CEDARLAND EMAIL MAILING ADDRESS SAME AS ABOVE CITY STATE ZIP PHONE CELL PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) I ZONING LEGAL DESCRIPTION(Abbreviated) to a FIRE DISTRICT SITE ADDRESS CITY ALLYN DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%:YES❑NO ❑ IS PROPERTY WITHIN 200 FT OF THE FOLLOWING:(Check all that apply): SALTWATER❑LAKE❑RIVER/CREEK ❑POND❑WETLAND ❑SEASONAL RUNOFF❑STREAM❑ TYPE OF WORK: NEW ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) RESIDENCE IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS_ 4 1[JMBER OF BATHROOMS_ 4 HEATED STRUCT ? YES (Whole Bldg)❑ YES(Part[s]ofBldg)❑ NO ❑ DESCRIBE WORK NEW CONSTRUCTION-SFR SOUARE FOOTAGE: (propose+existing) 1ST FLOOR 1200 sq.ft. 2ND FLOOR 1200 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq. ft. COVERED DECK 328 sq.ft STORAGE sq.ft. OTHER sq.ft. GARAGE 400 sq. ft. Attached x Detached❑ CARPORT sq.ft.Attached❑Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC ❑ SEWER NEW EXISTING❑ \-A X PLUMBING IN STRUCTURE? YES NO[II/ Ijyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS�R� POSED? YES❑ NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS 4 TOTAL BEDROOMS 4 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or legal �...............1:.... -.......-n....M�L...��1...:..i........:...........:.I...J:..........-...,..-d.......\.....-...1............0\�.-....../'.....w....w......w ..\4....L.......J.....v:L....l w........1.. MASON COUNTY COMMUNITY SERVICES Permit No: l31A 1.6 -0012 3 PERMIT ASSISTANCE CENTER: -BUILDING -PLANNING -FIRE MARSHAL RECEIVED 615 W. Alder St-Shelton,WA 98584 www.co.mason.wa.us PNG AIR 2 9 20 1 � L P Phone Shelton:(360)427-9670 ext. 352-Fax:(360)427-7798 Phone BeKair. (360)275-4467-Phone Elma:(360#f"?Alder Street PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: J&J DEVELOPMENT LLC ____. NAME:J& J DEVELOPMENT LLC.__MAILING ADDRESS:pO BOX P23 MAILING ADDRESS:PO BOX 623 CITY: BURLEY STATE:WA ZIP:98322 CITY: BURLEY STATE: WA ZIP: 98322 PHONE#I: 2p2*8136 PHONE: 253-208-8136 CELL: PHONE#2: _ EMAIL : inf�cedarlandforestresowces.com EMAIL: 8094cedarlandforestmourcm.com L&I REG#JJDEVJD8520W EXP. 12 /6 !21 PARCEL INFO MATION: nn r, PARCEL NUMBER(12 Digit Number): oC U2. Zoning: LEGAL DESCRIPTION(Abbreviated): SITE ADDRESS: CITY:ALLYN DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW X ADD ALT REPAIR OTHER USE OF BUILDING RESIDENCE LOCATION OF FIXTURES/UNITS—IsT FLOOR X 2NDFLOOR X BASEMENT GARAGE X OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG X Natural Gas Ductless_ Toilets 4 Type of Unit No.of Units Fees Bathroom Sink * (e Furnace 1 Bath Tubs 8 1b Heat Pump Showers 3 Spot Vent Fan 7 Water Heater 1 Propane Tank 1 Clothes Washer 1 Gas Outlets 2 Kitchen Sinks 1. Wood/Gas/Pellet Stove 1- Dishwasher 1 Kitchen Exhaust Hood 1 Hose bibs Other Dryer Vent 1 Solar Panel Base Fee Other TOTAL PLUMBING Base Fee TOTAL MECHANICAL OWNER acknowledge submission of inaccurate informatio .may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.1 declare that i am the owner,owners�9 al representative.or contractor.1 further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained p,rmission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized 1gent represents that the information provided is accurate and grants employees of Mason County access to the above described props nd structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced hin 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OFTHIS PERMIT IS BY MO F INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X 7�7 �, nature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN NORTH BAY SS" �`aaQa�•� 3 ALLY OF A1R.2 WATER r ;� Q e ALLYN UGA R 2 �,� �E D APR 2 9 2021 SFR W�2,pZl- _-- .� 696 W. Alder Street `' `a PLANNING : ALL SETBACKS ARE MEASURED 1 = 30 FROM THE FURTHEST PROJECTION OF THE BUILDING e(K 61 Ili 0c 60 !l v� Tar 3 v S / cy,. o 0 120.00 20 � a _ ? CAA,gGf 8 / 2 l! N 07- lv r2 !l 30 S 13 00 00.f 8 22 n <v / 120.Op 40T 1 ti0 B41r 59 HOUSE 1ST FLOOR 1200 SO. FT. APPROVED HOUSE 2ND FLOOR 1200 SQ. FT. 20 �r?M CMMTv, 'Dr-,D PLANN x 4 SQ, FT. PORCHES 80 0 5Q. FT. E PLAN REQUI12E;TO E*E CAN S PORCHES 144 SO. FT. CH&90ES SU64ET 10 APPROVAL LEGAL DESCRIPTION ADDRESS LOT 2 BLOCK 60, E SULLIVAN STREET J & J DEVELOPMENT LLC PLAT OF ALLYN, ALLYN, WA 98524 P.O. BOX 2264 VOLUME 1 OF PLATS, PACE 17 CIG HARBOR, WA 98335 AP No. 12220-50-60002 CED 2407 (253) 208-8136 c,.B E CN 1, SITE PLAN MAP AGATE LAND SURVEYING, PIW WA D PROFESSIOWAL LAND SURVEYOR' oF H� FOR SHELTON, WA 8584 - (360)�6 4172 U � J & J DEVELOPMENT LLC IN THE DRAWN BY DATE. 12/292020 X8 NO. �0 4148-6002 282 P ,w SW114 NE114 MJB S ��CISTF.I'F'p SCALE. T INCH = 30, SHEET• 1 OF 1 s/0 s 0 SEC 20, T22N, ROl W, W.M. CHECKED 8Y SGB FlLE No: 4148-6002_JJ_SITEPLAN.DWG NORTH BAY SEWER s1aaoQ1-w633 PORT OF ALLYN WATER .,� �..,�� ,�y"� � ALLYN UGA R.2 E. $ � E D APR 19 2021 K&U3 SFR. n 615 W. Alder Street `' \44, 30 ENVIRONMENTAL 1» = 30' / HEALTH Btk ' e`ock 60 ivy t pr 3 s � / cy, o° o repo ?o r = 2 cq,pgcF 8 N �oOUSF 30 S 73 00 -22? n A r2 ci .00 '1T t0r 1.0.. 2 B� S9 H F 1AppRQVEDOUSE 2ND FLOOR 1200 SQ. FT 20 GARAGE 400 SO. FT. NIAY 1 9 2021 ONT PORCHES 80 SO. FT, BACK PORCHES 144 SO. FT. MSONGOUNjyaVjRo"ffAIHEAM Ivir LEGAL DESCRIPRON ADDRESS LOT 2 BLOCK 60, E SULLIVAN STREET J do J DEVELOPMENT LLC PLAT OF ALLYN, ALLYN, WA. 98524 P.O. BOX 2264 VOLUME 1 OF PLATS PAGE 17 GIG HARBOR. WA 98335 AP No. 12220-50-60002 CEO 2407 (253) 208-8136 r,.BE SITE PLAN MAP AGATE LAND SURVEYING, PLW �f0 PROFESSIONAL LAND SURVEYOR °F wns H� � 9 FOR SHELTON, W =4 - (360) 425- 172 70 J & J DEVELOPMENT LLC 0 IN THE DRAWN BY DAIE. 12/292020 JOB No. 28237 �w SW114 NE114 MJB 4148-6002 s - STVX'- SCALE: 1 INCH = 30' SHEET 1 Of 1 slONaL LnNU s 0 SEC 20, T22N, R01 W, W.M. CHECKED BY SGB FlLE No: 4148-6002_JJ_SITEPLAN.DWG s A NameJO !JC r L���{T11��1 Parcel# )aU- —5D ll/l J)IJ2 BLD# bj RECE .-... Mason County i �A�021 Department of Community Development arcel Stormwater Management Application/Worksheet(page 1 of 2) .J� Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surfacez. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area 'All dimensions in feet Buildings 50 X 24 = 1200 20 X 20 = 400 Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways 22 X 20 = 440 X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks 24 X 6 = 144 10 X 4 = 40 Any paved, gravel or packed area per definition above table X = Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 2224 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet.please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 a�26~�o" (�( � - Name (� Parcel# I BLD# 1�eV� �Pm�n Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet(page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety A=no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. "These details are found in the document Managing Storer Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) X The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel. You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative, or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review a�inspecti spon as in required. X —� /�i�/ Owner/Agent/Contractor(circle one)Date: I Page 2 of 2 MASON COUNTY DEPARTMENT 00 COMMUNITY DEVELOPMENT WSEC/ Ventilation Code Compliance Application Submit with heating/cooling system size worksheet (see instructions #4) Owne : � Parcel#: Type of project: 75 J Df vtJo 50 bQQQ,_�_ I NEW CONSTRUCTION - SFR Total Sq. Ft. 1 st Floor: 2'floor: Heated Basement: of heated area:: 2400 1200 1200 Heating System Type: O Electric wall heater O Electric Central Furnace PG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: Prescriptive Option Table R402.1.1 (see table on previous page) Compliance Method O Component Performance, R402.1.3 — Calculation worksheets required Muc!Check one: O Other (Specify): Chick one O Whole House Ventilation system Whole House Ventilation using exhaust fans&window or wall n rated with a Forced Air O Other,describe: Ventilatio fresh air vents (M1507.3.4). If using System (M1507.3.5) n System window vents be sure to order windows with vents. Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/iecc wsec.pdf a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor Additional area and less than 300 sq. ft fenestration area (skylights, doors, windows,etc). Energy "Including additions to existing building that are greater than 500 sq. ft. of heated floor Efficiency Requirem but less than 1,500 sq ft of floor area. Requires 1.5 credits ents b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c)below Energy {large dwelling) Requires 3.5 credits credits EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5 required: credits. See page two for description. 3.5 c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area. Requires 4.5 credits d) Additions less than 500 sq feet. Requires .5 credits (Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. Describe Energy Credit Option(s): Using Option - EFF BLDG ENVELOPE number(s): - HIGH EFF HVAC - EFF WATER HEATING 1 a, 3a, 5a, 5c 3 ., t -1 �-� > Window,Skylight and Door Schedule ( -E e 3 r �/ CED2407 Joe Cedadand r 253-208-8136 APR r1 9 U L VNdlh Height 15 W.Alder v,.,at Ref. U-factor Qt. Feet Feet "M Area UA Exempt Swinging Door(24 sq.ft.max.) 0.0 0.00 Exempt Glazed Fenestration(15 sq.ft.max.) 0.0 0.00 Vertical Fenestration(1Mndows and doors) Component :;dth P.C;:yh Descri tion Ref U-factor Qt. Feet " " Feet "`" Area UA FRO' LEVATION I I 1 0.0 0.00 0.28 16 13 1 15 90.0 25.20 028 2 13 1 6 40.0 11.20 _0 0.00 REAR ELEVATION 0.0 0.00 0.28 2 5 3 35.0 9.80 1028 1 1 12 6 ° 17.8 4.98 0.01 0.00 RIGHT SIDE ELEVATION 1. 1 1 1 0.ol 0.00 0.28 1 13 1 13 10.5 2-94 0.28 1 14 1 13 14.0 3.92 0.28 1 ti 21.0 5.88 0.28 2 6 2- 30.0 8.40 0.0 0.00 LEFT SIDE ELEVATION 0.0 0.00 128 1 5 17.5 4.90 026 1 2 3 6.0 1.68 028 1 3 13 9.0 252 0-28 1 4 3 _ 14 0 3.92 0.28 1 2 3 6.0 1.68 0.0 0.00 6.0 0.00 0.0 0.00 0.0 0.00 6.6 0.00 0.0 0.00 6.6 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.o 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.01 0.00 0.01 0.00 0.01 0.00 Sum of Vertical Fenestration Area and UA 310.8 87.02 Vertical Fenestration Area Weighted U=UA/Araa 1 0.28 Overhead Glazing(Skylights) Component Width Height Description Ref. U-factor Ot. Feet "d' Feet "" Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 O.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U=UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) 310.8 87.02 f � Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information _ CE02407 1OE CEDARIAND 253-208-8136 Heating System Type: 11111All other Systems 0 Heat P�p To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Design Temperature Difference(AT) 41 Bremerton ' ' AT=Indoor(70 degrees)-outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) F 2.400 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 9.0 21,600 Glazing and Doors U-Factor X Area = UA U-0.28 0280 311 BT02 Skylights U-Factor X Area = UA 'ostluctiorls 0.50 — Insulation Attic U-Factor X Area = UA R-49 0.026 1,200 31.20 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA No Vaulted Ceilincis in this project. Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions 0.056 2,089 116.98 k: R-21 Intermediate Floors U-Factor X Area UA coons —�—TI 0.025 1,200 30.00 R-38 —.._LJ Below Grade Walls(see Figure i) U-Factor X Area UA Instructlor 0.028 No Below Grade Walls in this project. low Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions 0303 No Slab Below Gr . ade in this project. � — Slab on Grade(see Figure i) F-Factor X Length UA instructions '— P — No Slab on Grade in this project Location of Ducts Duct Leakage Coefficient Unconditioned Space 1.10 Sum of UA 265.21 Envelope Heat Load 10,874 Btu/Hour Figure 1. SurnofUAX\T Air Leakage Heat Load 9,564 Btu I Hour Vdume x a6 X 1 T X.018 Ahove Grave Building Design Heat Load 20,438 Btu/Hour Ar Leakage�Envelope Heat Loss Building and Duct Heat Load 22,482 Btu/Hour Ducts in unconditioned space:Sum of&ending Heal Loss X 1.10 Ducts in corldffiDned space:Sum of Buddvg Heat Loss X 1 Maximum Heat Equipment Output 31,475 Btu I Hour Belding and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information CED2407 Joe Cedarland 253-208-8136 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCbe n/a n/a Ceilingk 49' 0.026 Wood Frame Wall9`"," 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Well`' 10/15/21 int+TB 0.042 Slab R-Value&Depth 10,2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits QDwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. �. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3.Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. M3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) 1a Efficient Building Envelope 1a 0.5 0.5 1 b Efficient Building Envelope lb 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Table R402.1.1 Footnotes For SI: 1 foot.=304.8 mm,ci .=continuous insulation, int.=irtermediate framing. a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. c"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall."10/15/21.+TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."10/13" means R- 10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1. 'There are no SHGC requirements in the Marine Zone. f Reserved. B Reserved. h Reserved. 'The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section R402.1.3.