HomeMy WebLinkAboutSPI2005-00030 - SPI Inspections - 10/11/2013 PyoN"STATE°� MASON COUNTY
o A o N DEPARTMENT OF COMMUNITY DEVELOPMENT
N Planning Division
o Y n P O Box 279, Shelton,WA 98584
0 (360)427-9670
1864
Site Inspection
October 07, 2005
MARH FOERSTER
6278SHARBOR HEIGHTS PKWY TO BE KEPT IN THIS
MUKILTEO WA 98275 PARCEL FILE
Case No.: SP12005-00030 N
Parcel No.: 322352100030 O
Project Description: FEASIBILITY
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below you
will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands must
be included in your specific proposal; these setbacks are included as part of the comments listed
below.
This information is based on County and State regulations as they exist to date. These regulations
may change and may affect the requirements for development of the subject property.
Please contact me at(360) 427-9670, ext. 365 if you have questions.
Sincerely,
* aydac__�'
Allan Borden
Land Use Planner
Mason County Planning Department
10/7/2005 1 of 3 SP12005-00030
r
Site Inspection
10/7/2005 Case No.: SP12005-00030
Comments:
Pre-inspection for Marsh Foester on Feb. 17, 2005:
The purpose of the pre-inspection was to evaluate issues related
to the construction of a single family residence on a 0.23 acre
parcel along Hood Canal east of Tahuya. The parcel has a lawn
maintained area where a residence, garage/shed structures,
septic system, and associated parking may be located. The
shoreline is nearly flat adjacent to a concrete bulkhead along the
beach; the adjacent properties also have shoreline bulkheads.
Geotech Report/ Landslide hazards: There are steep slopes that
exceed 60% along the north side of North Shore Road. Due to
the slopes and instabilities of the bank being adjacent to or within
300 feet of the proposed building site, a Geotechnical Report is
needed for any proposed construction within 300-feet of these
natural and modified slopes. The Geotechnical Report format is
contained in Mason County Resource Ordinance section
17.01.100 E.S. The report must state the conditions on the
property, that the hazards of the landslide area can be overcome
in such a manner as to prevent harm to property and public health
and safety, and must also assure the proposed site preparation
and construction will cause no significant environmental impact.
This study must accompany any development permit and should
be based upon the footprint area where structures are proposed.
The zone designation for the site is Rural Residential 5. Standard
building setbacks for this zone are a 25 foot front yard setback,
and 20 foot side setback (or 10 percent of the lot width at the
building setback; for this parcel 10 feet). An administrative
variance may be considered for reducing the side yard setback (to
no less than 5 feet) or reducing the front yard setback (to no less
than 10 feet), if a reasonable development proposal is
constrained by the standard setback distance. These setbacks
are measured from structures above grade such as roof
overhangs (roof gutters), and other structures / appurtenances,
including balconies, decks, staircases, and heat pumps etc.
Shoreline setbacks: The shoreline designation for the area is
Urban Environment per the Mason County Shoreline Master
Program and setbacks would be determined by the Mason County
Resource Ordinance. The shoreline setback is determined by
measuring the setbacks from the shore ordinary high water mark
(OHWM) to the roof eaves of adjacent residences within 150 feet
of the east and west property lines of the subject parcel, and then
averaging the distances for the shoreline setback of the subject
parcel. Any portion of the new structure, including decks,
10/7/2005 2 of 3 SP12005-00030
Site Inspection
10/7/2005 Case No.: SP12005-00030
balconies, and rooflines, must be behind this common line.
Landward of this line for 15 ft. toward the shoreline is an area that
may be used for lawns or patios or landscaping, etc.
(development at grade level). From that point toward the
shoreline is considered to be a required vegetated buffer and is
regulated by the Mason County Resource Ordinance Fish and
Wildlife Habitat Conservation Areas Chapter. Within this chapter
are those activities listed that can be done both with and without a
Mason Environmental Permit.
The existing residences on adjacent lots west and east are
situated at 15 or 20 feet from the respective bulkheads. Despite
this shore commonline distance, the measured distances of the
proposed structure footprint to the OHWM at the bulkhead should
be no less than 35 feet, the minimum shoreline setback set forth
in the Resource Ordinance. When applying this standard, the
limiting factor in placing the new residence is the east 30 foot
width of the property has a narrow area available to develop and
in turn meet the side, front, and shore setback distances. Notes
on the enclosed drawing may help to visualize these findings. All
of these footprint and setback facts will be considered in the
evaluation of the site plan during building permit review.
General process: Future site development must include a site
plan, showing all setbacks from property lines and shoreline, and
will be needed for building permit application submittal. The
geotechnical report should be submitted at that time as well.
Specific standards for future development contained in County
Codes may be found at the County website address
http://www.co.mason.wa.us. If you have any questions please
feel free to call. Thank you.
10/7/2005 3 of 3 SP12005-00030
1-7 MwAiv onc
MASON COUNTY (
PLANNING DEPT. PRE-INSPECTION APPLICATION
PLEASE PRINT $205.00 Fee Required
1. Owner:----------------- -------------------- Applicant:_.�L1G-� C��_fiKy� 1T__G_�
Site Address:-,-- 12 . �q
��� f�r�lyQ�tr�Swop.¢�oAD Applicant Address:__I g-�---
Owner Address: __ __ __________________— City:_— i� ------St- Zip
City:--------------------St-------Zip---------- Phone:_(_W(a)__G_G_5_ _4_-1 1-----—------day
Phone:-(-----)-----------------------------day Phone:_(ZQf,2)__&24-a442 -------evening
2. Parcel No. 23 -_2 1 -_04;Uo a0_oCL-40? rr JJ
Parcel No. - - _ Email Address: _T'_l'tC_fr10q h'1�i1.CO Fr►
---- --------- ---- -
Legal Description: _ _______________ Planner: A S �7
�V
---------------L --Q_ ------------- SMP� _ 1/�jomp. Plan— Vt� YPe of Use --
----------------------------------------- Water Body {Opp CAAJAL-----------
3. Purpos of Pr -Inspection : al✓C 5�,�►� __ _ _ _� r_ r vVa
-- -
�_ c � _74- _?,e, ___ -�L .------------------------------------
-------------- ----
4. Use of Building: `1 � ��_rY�_b(�1�A'�v�o�_c rY 7`
5. Do any of the following exist on or adjacent to property?: slope (4 saltwater(Y� lake ) river ( )
pond ( ) wetland ) seasonal runoff ) other ( ) stream ( ) seasonal creek )
Directions to Site: 8 EGF IR _T_nAV C-L _A PPXOXIMAVL1 I Z YZ_M I LE-5_ W E�S
ON Sa- Ajo2rN SHor�Go�D .__L/����__LOT__/S_
�1111 �__ z 3 S _A IVD %246 I E/va2rH 5NorjF _14GGc TO_TT N LOT —
�ilgrm r_N t=_PA61 Irmill _ Ho u S _ _L2�b l-N $�-'S 2If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the
original application. Pre-inspection reports remain valid only until development changes occur in the vicinity which
affect the lot evaluated in this inspection, or the laws regulating development of the site change after the time of
inspection.
0
:�4�
Applicant Signature: _ ------------------Date:
If you would like to be on site during inspection, please check here: (ate -------
Return application to: Department of Community Development, Planning Division
P.O. Box 279 FE% 0 2 203
Shelton, WA 98584
(360) 427-9670 MCC
- PLANNING
Please include a $205.00 check or money order payable to Mason County Treasurer
When completed, this form becomes part of the parcel file.
FOR OFFICE USE ONLY: Accepted by: -------------------------------------Date:-------------_--
Please illustrate below the proposed building site in relation to water &property lines:
SRG/Word/MyDocuments/TypedStulNPre-InsWbon MORE ON BACK SIDE
Please illu3trate below the proposed building site in relation to water and property lines:
R �
r4,
O
C
IZ3 i►•. Spec
Departmental Review
(For Office Use Only)
Planning Department Findings:
--- -----------
------ U44�- ---� - � ------------
------------------------------------------------------
------------------------------------------------------
-------------
------------------------------------------------------
------------------------------------------------------
Revised 12-26-2003 SRG