RESIDENTIAL BUILDING PERMIT BLD2009-01096
OWNER: RONNIE LARSON RECEIVED: 12/31/2009
CONTRACTOR: LICENSE: EXP: ISSUED: 2/28/2011
SITE ADDRESS: 21 E WHEELWRIGHT ST ALLYN EXPIRES: 8/28/2011
PARCEL NUMBER: 122205075008
LEGAL DESCRIPTION: ALLYN BLK: 75 LTS 8-10 &VAC ALLEY ADJ
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Two story Storage Building. Lakeland Dr. and Wheelright south
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.: VB
Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: 74
Type of Work: ACC Fire Dist.: No. of Stories: 2 Occ. Load: Building:336
Valuation: Building Height: Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline& Planning Information
:
y
Make: Length: Ft. Front: W 100.0 Ft. Shoreline: Ft. Water Body:
No
Model: Width: Ft. Rear: E Ft. Slope: Ft. Shoreline Desi
Side 1: E 5.0 Ft. 9.: Not Applicable
Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Urban Growth Area
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee TW 12/31/200 $172.41 S12009000
Planning Review Fee TW 12/31/200 $205.00 S12009000
BLD Vio. Investigation Fee DLC 1/5/2010 $73.00 S12011000
Building State Fee DLC 2/7/2011 $4.50 S12011000
Building Permit Fee DLC 2/7/2011 $251.25 S12011000
ADJUST--Plan Check Fee DLC 2/7/2011 -$9.10 S12011000
Total $697.06
BLD2009-01096 Please referto the following pages for conditions of this permit. 1 of 4
Permit# MASON COUNTY
BUILDING 111 426 W, CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items listed below must be corrected to gain compliance
cam.
G
e
7-0 14 4i0 iy
o is Left o��si�'
G T a
C2
fouAare hereby notifl tVat the above correiAidns shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office
Make corrections, items will be checked on next inspection regarding possible structural
❑ OK to damage incurred by recent
"natural/man made"
❑ This is not a complete inspection disasters.This is NOTa
Date — ' '- CORRECTION NOTICE.
� � - ,/ ,�_ Department
Inspector Zz-
ov* v No 01T ' 'iml* 014 ' ' THI , o T' * mr
Permit# MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASH JNGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location ?-/ 5/-
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items listed below must be corrected to gain compliance
Z?ilic..7- Z =s%off Y )C / 06-LC-.0Z d-
,ti l�aX Z 2
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office
❑ Make corrections, items will be checked on next inspection regarding possible structural
❑ OK to damage incurred by recent
"natural/man made"
❑ This is not a complete inspection disasters.This is NOT a
Date -/5�-��' Department �L� CORRECTION NOTICE.
Inspector Z3
DO NnT RJ=MnV ' THI c T,--'m-G
l
00
o CONCRETE MECHANICAL MANUFACTURED HOME D
0 Date By X
0 Footings !Setbacks Ribbons
Gas Piping O
o Interior Date By Interior-Date By Date By Z
rnExtew Date By Exterior-Date �_ _ BSet-up
Point Load t Isolated Footings INSULATION _ Date By Z
Date By BG f SLAB INSULATION - Z
Data By FIRE DEPARTMENT m
Foundation Wails Floors -' Date By
Date By Data By DECKS
FRAMING walls Date By
Date By Data By PROPANE TANKS
PLUMBING vault Data _..�_._13?!'_____
Date By OTHER
Groundwork Attic
Type.
Data By Date By Dato By
D.w.v
s DRYWALL Type
Int.Brace Wail Date By W
Date By Dale By FINAL INSPECTION 0
v Water Line Fire Separation
Dale By Date By Data By p
m to
Pass or Request Inspect, o
0 Type of insp. Fail Date Date Done By Comments CD
CD.
S7 p n'/4
a
77—
im j -.-LAr �,>.,. esr� Gc, f� f S/�r 4-IS
T
L1
C
0
J
cot",
MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
Mason County Bldg. III, 426 West Cedar Street
— _ PO Box 186, Shelton, WA 98584
1854 www.co.masonma.us Shelton (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269
April 13,2010
Ken and Ronnie Larson
PO Box 1016
Allyn, WA 98524
Re Building Permit Number: BLD2009-01096
Dear Mr.And Mrs. Larson,
Thank you for submitting the building permit application referenced above. In order to complete the
building department review additional information will be needed which is listed below.
PLAN REVIEW REQUIREMENT COMMENTS:
Qs
ased upon information available to our office the location of the structure is placed along the fence,which
also the property line. The survey completed by Mr. Robert Emerson in December 2009 and recorded
under Auditor File number 1951410 does not show the location of the fence or the shed/tree house. When I
contacted Mr.Emerson in December 2009 to discuss the survey he informed me that the property line is
located at the fence line. Please provide documents demonstrating that the location of the shed/tree house
meets the required setbacks for the planning department and building code.
2. Based upon the documents submitted for the 2-story shed/tree house the prescriptive requirements for shear
wall bracing specified in the 2006 International Residential Code (IRC) Section R602.10 cannot be
achieved unless the structure is modified to meet IRC requirements. Braced wall panels are required to be
marked on plans and placed in all structures to address seismic and wind conditions in our area. Note that
in seismic design category D2 the first floor of a 2-story prescriptive structure requires braced wall lines
that amount to 55%of the wall length. In addition braced wall panels shall not-exceed 25-ft on center in
plane and in the transverse direction. Where prescriptive requirements are not possible those portions that
do not comply shall be designed and constructed in accordance with accepted engineering practice. When
a lateral design is necessary a Washington State licensed design professional must prepare the design.
3. On April 8,2010 our office received a partial elevation plan showing the wall-framing layout for a one-
story structure and a foundation plan showing a 10-inch x 12-inch footing. In order to properly evaluate the
structure a full set of legible construction plans, drawn to scale, shall be required and shall include the
following:
a. Foundation plan, including information showing that the foundation meets or exceeds minimum
prescriptive requirements or provide an engineered design of the foundation system. See
information enclosed.
b. Cross-section of the structure from foundation to roof,
c. Deck and floor framing layout including joists and support beams for the upper floor and deck,
d. Floor plan showing the use of ALL rooms,opening sizes of windows and doors, header
information,shear wall locations and type,etc.
e. Stairway framing information showing access to upper floor,
f. Roof framing details, including rafters sizes and layout,beam sizes and span,etc.
When the requested information is received staff will review the documents and evaluate for code
compliance. Generic information is enclosed to help you identify the information needed.
4. Please provide a completed Washington State Energy Code application in order to identify that the
structure, if heated,meets minimum energy code requirements.
To complete an engineered analysis your design professional will need the following information:
Snow load: 25 psf
Wind load: 85 mph, exp`B"unless designated otherwise
Seismic zone: D2
When you have compiled the requested information please submit it to the Mason County Building Department,
attention D. Coker. Please respond to comments, in writing,in the order listed. Revisions,required as a result of
the engineered design,must be transferred onto proposed building plans. Where required,please return two sets of
revised plans and documents along with two sets of calculations. If you have questions please contact me at(360)
427-9670 ext. 510 or via e-mail at: dlc@co.mason.wa.us
Sincerely,
Debbera Coker
Mason County Building Department
Plans Examiner
Word/BLD2009-01096
Encl.: Plan detail information
Prescriptive foundation detail
Washington State Energy Code compliance form
ason County Planning Department
imoio
Case Activity Listing 9:24:35AM:35AM
Case #: BLD2009-01096
P10
Assigned Done
Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By
BLDA010 Application Received 12/31/2009 None 12/31/2009 TW
BLDBI 10 Building Plan Review 12/31/2009 None HOLD DLC DLC 1/6/2010 DLC
Contacted the surveyor,Mr.Emerson,to discuss location of the property line. According to the surveyor the site plan may be incorrect as the fence is supposed located on the property line,see recorded
survey af#1951411. Notified the planner who will follow-up and notifty bldg dept.of findings. Also,LMOR for owner notifying them of the findings and that if the structure were to be approved as
proposed additional fire resistive construction will be required. The owner was also notified that there are also construction questions. Specifics were not provided in the voice mail message. NOTE: It
appears that a lateral analysis will be required. A floor/story was added to an existing storage structure. When this occurs the lower floor must comply with code requirements inclUding existing foundation
system. do
BLDB130 Planning Review 12/31/2009 None AHB 1/6/2010 DLC
Please notify bldg dept.when approved. do 1.6.2010
Page 1 of 1 CaseActivity..rpt
From: Debbera Coker
To: Borden, Allan
Date: 1/7/2010 12:54 PM
Subject: Larson separation
Hi Alan...
Concerning the Larson separation there is actually a state WAC that allows 3-ft to property line without requiring fire resistive
construction and even less depending upon the use of the structure. A portion of the amendment is pasted below.
LOCATION ON LOT
R302.1 Exterior Walls. Exterior walls with a fire separation distance less than 3 feet(914 mm)shall have not less than a one-
hour fire-resistive rating with exposure from both sides. Projections shall not extend to a point closer than 2 feet(610 mm)
from the line used to determine the fire separation distance.
Exception: Detached garages accessory to a dwelling located within 2 feet of a lot line may have roof eave projections not
exceeding 4 inches.
Projections extending into the fire separation distance shall have not less than one-hour fire-resistive construction on the
underside.The above provisions shall not apply to walls which are perpendicular to the line used to determine the fire
separation distance.
Exception:Tool and storage sheds,playhouses and similar structures exempted from permits by R105.2 are not required to
provide wall protection based on location on the lot. Projections beyond the exterior wall shall not extend over the lot line.
V11���LW�.GNT Si
Lr N F,
U7
c5 2 I E WAMWRI a 4T ST.
Ai-L` V I WA q RsD4
d �
Q
ua kW3
OZ
— '6I 6uiu� tpeg wowpag
wo��+ apa8
APPROVED
Z U-rdBu^� ASON COUNTY DCD PLAN °!1NGi
rn �
jeoz smn SITE PLAN REQUIRED TO BE ON 11t
azz woos o CHANGES SUBJECT TO APPROVAL
woapeg -�
'"'°°'peg IG!wej Date-6-1ceud
do4s4ioM �p
t, T ,ti ZZ
RECEIVED
� z
c" APR 19 2010
` 14 ,� 4 N 1 426 W. CEDAR ST.
FEN
TOPOGRAPHY PROFILE: PKc�I°� LIN ' •
Direction: Scale: Approval:for office use
Building Permit number: ' j« = 2( ` Building:
Owner/Applicant:J<15K $ "NNIE t.P+95Z-K => Date of Planning:
Parcel Number: , V
I ap-50-� `7�oag A f application: Env. Health:
I U ! Q
w
y
44112" 4-4112"
-x o
--------4x$---------------- rt
L /-/-/-/� ►) 4 x
V
'
,ti I I o
b I to
s
r / I —————— ,3-0 (()po
I
4' 1 6=10 5✓ /"
I t/f
-------------- -------
�:l o rn 2- x Lf
Ken& Ronnie Larson '
I'0 Box 1016
Allyn,WA 9&524
2I E. Whee I wrl Jh-t St,
U T�
8"Rail
--- - --------------
4'4 D"Rail
_ 15'-9" ao
3=51/16" 1i Z,-S„15/16" - - 1-8"
3-0•xf'8• \ r8•xe 8•
c _
c �
s
i N
ao 1 T-5'; RidgeHt=3'-1 D 11116" h
Q) cv O A
OD
CY) a
--- -----
6L1-13116"_ — -
4'-1"Rail
Ah Ask
r�
Ken& Ronnie Larson
PO box 1016
Allyn,WA 98624
om
23 E VJ;-weIvv-j h+ �t
I I
I I
� I
I I
� I
I I
I
I I
� I
I I
� I
I I
I I
I I
I
I
I
I
I
I
I
i
I
-------------------------------
O.8'
Ken& Ronnie Larson `, N PO box 1016
Allyn,WA 98524
2( r-- Whafar''j(lf-
St
----------------
X-0, V6• / ?g•Xgg
w w
►V O
--------------------------
4
h
O N
Ken& Ronnie Larson N
PO Box 1016
AIlyn,WA 98624
e�
2.[ E 1n1 .!w�r9hf Sf
�» .
� z9��` .
v -.
e
a:?
v ;
. . . . . . , : .
Ken & Ronnie Lmm
` PO box]m a
«y Allyn,&a 98624
2 E- Wk&j wi-i/K
c
~ �1
t �, Ken& Ronnie Larson
W-4 PO Box 1016
_'.._-4— Allyn,WA 98524
21 t Wke-t!wr)"9 ht St:
Ken & Ronnie Larson
PO Box1016
Allyn,WA 98524
m
2( G 4"V41e2Jv4rj'
40
X
1
� aj:ro
.Y >
A i
4
f
Ken& Ronnie Larson
PO Box1016
Allyn,WA 95624
'LI E WF1eel1VC(j'I+ St.
y
o i Ken& Ronnie Larson
``0 4 PO Box 1016
Allyn,WA 98624
u wght st
40
vt
H&H
tT
10/15/2009 10/15/2009
i tf
10/15/2009 10/15/2009
10/15/2009'
c.
,ip
r
�*1
z-
A
f
r�
i
�� Vp
jr11F—
J
Ar
r,�� vim• +. � 't' � rj -
.,ter' Al_ y ;,
.fry
t
WHEEL—WRIC-14T ST
i !✓S)
{
-
3
U, l �e
-� E3
CS> --
wOC,6 4u3
IN
- 61 &xwa Utea woaPae
r_
7 uau uwaPag
a6eje(� � woos tiutnr�
NO z sign "tl
ZZ 'V
wooa o
w�Pee /4lweJ wooipagTt
do M RECEIVED
ti .£I ,y
f)Ecs� y APR � 9
1010
426 W, CEDAR ST_.
TOPOGRAPHY PROFILE: rP90,15 LINE I V
Building Permit number:
Direction: Scale: Approval: for once use
1 = 20` Building:
Owner/Applicant: K15K 4 "NNIL 1.P+R-441,1 � Date of Planning:
Parcel Number: , V
��50� '���OB r application: Env. Health:
Page 1 of 1
ML. s '
M
e Y,y
b
y
t
Sa ,., �x" ✓^., x
pa
Y
kg
,• i
,v
3
file://Q:\Documents\200910\BCC20090.017\6\BCC2009-00176, TAKEN 10.15.2009#2.JPG 1/6/2010
Page 1 of 1
=r
Ow
A
�s
v>
?L
� III III
q
file://Q:\Documents\200910\BCC20090.017\6\BCC2009-00176, TAKEN 10.15.2009#1.JPG 1/6/2010
(2( /10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page 1
l
From: Debbera Coker
To: Larson, Ronnie
CC: McFarland, Genie
Date: 2/10/2011 8:50 AM
Subject: RE: Ken & Ronnie Larson project number 10.310
The fees paid when the permit was submitted addressed plan review fees related to building department
and planning dept. only. The building permit is collected when the permit is issued along with other fees
associated with the case, which is the site investigation fee charged as a result of the correction notice
posting. Sorry that you were not aware of the permit fees when the permit was submitted. When the
permit was submitted we were very concerned about the location of the structure to adjacent properties
and really focused conversations to that issue, not on fees. Our Department is fee supported, dependent
upon the plan review fee for time spent preparing the documents for issue and the permit fee which is
related to actual inspections in the field. The fees are adopted by our Commissioners.
The permit fee DOES NOT include an enforcement fee (double permit fee) because you responded to the
correction notice as requested.
Your permit can remain here until the fees are paid up to 6 months. Extensions can be granted when
requested due to hardship. If that is the case please keep us posted, in writing, not to exceed 6 months
each time. We know that you are anxious to finish this project. Sorry to add another obstacle. The
adopted fees are not negotiable and out of our hands.
Debbera Coker
Mason County Building Department
Building Inspector IV/Code Enforcement
Phone: (360)427-9670 ext 510
FAX: (360) 427-7798
e-Mail: DLC@co.mason.wa.us
PO Box 186
426 West Cedar Street
Shelton, WA 98584
>>> Ronnie Larson <einnor64CcDhotmail.com> 2/9/2011 7:48 PM >>>
Thank you Debbera, again, for your help. I did get a call from a Jeannie who said we could pick up our
permit now for only $319.65??which was another shock to me because I thought we paid all the fees up
front and now I don't have a dime and don't have $300 to pick up the permit!! It will take me a month or
two to come up with that right now, I don't even have grocery money left this month and it's only the 9th.
Can you tell me what these fees are for?
You can call me at work at (360)277-2166 between 7 and 2 or just email me back.
Thanks,
Ronnie Larson
> Date: Mon, 7 Feb 2011 08:07:46 -0800
> From: Dlc co.mason.wa.us
> To: einnor64(a)hotmail.com
> Subject: RE: Ken & Ronnie Larson project number 10.310
> I plan to work on your project today. When I am completed I will make sure that staff knows that you are
anxious. They will call when processed, typically within 24-hours after the file is complete.
> Mr. Hodge was extremely helpful. You are right WOW!
(2/10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page 2
> >>> Ronnie Larson <einnor64(@hotmail.com> 2/5/2011 6:23 PM >>>
> Dear Debbera,
> WOW is all I can say, since this is all Greek to me but does this mean we'll get our building permit now
and can finish?
> Thanks for all your help!
> Ronnie Larson
> > Date: Thu, 3 Feb 2011 16:03:57 -0800
> > From: Dlc co.mason.wa.us
> > To: iohnCa�hodgeengineering.com
> > CC: einnor64(ahotmail.com
> > Subject: RE: Ken & Ronnie Larson project number 10.310
> > Looks good to me. You are awesome. Thank you for taking care of the Larson's.
»
> > Debbera Coker
> > Mason County Building Department
> > Building Inspector IV/Code Enforcement
> > Phone: (360)427-9670 ext 510
> > FAX: (360)427-7798
> > e-Mail: DLC(&co.mason.wa.us
> > PO Box 186
> >426 West Cedar Street
> > Shelton, WA 98584
> > >>> "John Hodge" <johnahodgeengineering.com> 2/3/2011 3:33 PM >>>
> >Assuming 1500 psf bearing capacity for the soil a 10"footing will provide
> > (10/12)x1500 = 1250 pound per linear foot.
> > The foundation has 4' of tributary roof load and 4' of tributary floor
> > loading each floor. The load to the foundation is 4x(15+30) + 8x(10+40) _
> > 580 pounds per linear foot,
> > 1250 > 580 The 10"wide footing is adequate.
> > The frost depth is a jurisdiction determination. However, I've attached a
> > quick analysis of the footing as a grade beam. With the 580 pounds per
> > linear foot it can span 8'. So if the ground did freeze and the foundation
> > was supported at only locations 8' apart it would be 40% loaded. In my
> > professional opinion the foundation can support the structure during a frost
> > heave.
> > Hope this helps.
> > John
> > John Hodge P.E.
> > Hodge Engineering, Inc.
> > 2615 Jahn Ave NW Suite E5
(2/10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page J J
> > Gig Harbor, WA. 98335
> > 253-857-7055 fax 857-7599
> > -----Original Message-----
* > From: Debbera Coker fmailto:Dlc(d,)co.mason.wa.usl
> > Sent: Thursday, February 03, 2011 3:08 PM
> > To: John Hodge
> > Subject: RE: Ken & Ronnie Larson project number 10.310
> > Did not receive this plan. Helpful....I can work with everything but the
> > foundation.
> > The foundation does not meet prescriptive IRC specifications (15"width for
> > a 2-story). Frost depth is 12-inches, according to plan the footing is 10"
> > wide x 12" high. Is there anything an engineer can do?
> > Debbera Coker
> > Mason County Building Department
> > Building Inspector IV/Code Enforcement
> > Phone: (360)427-9670 ext 510
> > FAX: (360) 427-7798
> > e-Mail: DLC@co.mason.wa.us
> > PO Box 186
> > 426 West Cedar Street
> > Shelton, WA 98584
MASON COUNTY PERMIT NO.. 10 (4
BUILDING PERMIT APPLICATION
426 W. Cedar• P.O. Box 185, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482- Ck
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner KE-N_A, RONN/E LARSON Company Name SE-LL'
Mailin Address PO OOX 10142 Mailing Address Same as aDol,can f
City LL�N State A Zip Code 9 52- City State Zip Code
Phone 3 0 d77- 0 Other Ph. Phone Other Ph.
Lien/Title Holder Contractor Reg. # Exp.
E mail address P/nQor(o F tiofrna%/•con) E Mail Address
Drivers Lic.# 4AQ$0RE3(o9P4 DOB /OL211,4 Drivers Lic.# DOB
SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic n0 Existing Septic no
Connect to Water System " Name of Water System
Well Water System Name of Water System U
PARCEL INFORM TI N- 12 Di it Parcel No G Fire District
Legal Description ` D ��`�> �U �� �� A/Ivn 1/oJvrle / c( �I41S� �q / 7, I-ec-cy4s oEMaSon 60,,1 1
Site Address(Please include street name,street npmber and city 2l E (Nhe�lwr��>� St All,,r, (n/A 4g5a�
Directions to site�yT 3 �o �/a"S f/ eo+rtP� ° F✓ans
Will timber be cut and sold in parcel preparation?Yes o
Is property within 200'of Saltwater klA> Lake wv River/Creek v>� Pond VIA
Wetland ►w Seasonal Runoff hA Stream K.0 Slopes or Bluffs ] 15% hA
Is this permit submittal the result of a Stop Work Notice orrec ro otice or other enforcement action?( es to
TYPE OF JOB - New _Add Alt Repair Other Ia� PRIMARY RESIDENCE ❑ SEASONAL 0
Use of Building 3W + I r-"--►'ovse Describe Work
No. of Bedrooms 0 No. of Bathrooms 0 Square Footage- 1 st Floor /92 2nd Floor /92- 5F
3rd Floor Basement Deck I s Covered Deck — Other _ Sq.ft.
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION -Make- Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price$ Replacement Unit? Yes/No
Installer Name Certification No.
OWNER/BUILDER Admowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of
such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is
required from any easement holier or any other party in interest regarding this application or the work proposed in theft application,I have obtained
permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information
provided is accurate and grants employees of Mason County access to fhe above described property and structure for review and inspection.
PROOF CONUA N OF WORK IS BY MEANS OF A PROGRESS INSPECTION.
x ��NTI11(t 1",4 L Date:
Owner/Owners Representative/Contractor indicate which one
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department I 0
Planning Department X cj' f X /G =
Environmental Health Department 4, x g
Public Works Department
Fire Marshal
FEES
Building Permit Fee ` 5/ 5 Site Ins ection i
Plan Review Fee Z ,0 v> > EH Review Fee
Plumbing& Base Fee Planning Review Fee
Mechanical& Base fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES
3 :3c,
�e cLl L4 81,
2
y J(o
0
122205800019 122205066005
122205067005
122205800020
A.
��'•� �` . - � 122205067002 O
122202400000 122205068002
#+ 122205069002
f 'T',�I ♦ s.r�. �
' 122205067001
�122205068001
12 !4OWOOJF 122205069001
f ar
R
�D
CO �" _ w ®R 122205070001
o
2 122205075008
T-2 2ZNti
�► � ; 122205075005 �•
l 122205010000 r y >
122205073006
122205074001
4T
122205075002
Ai
o , r
1 `a.} s; ♦ 122205073001
`w.
i � �-: _ � f � 1222050720011
. . _ 122205077001 f
f
♦12220006001000,
- : 122205079006 w 122205080009
f 1 inch = 100 feet
777 1 inch = 0.02 miles
�d'
►row— —. — — — --- — — — — — — — — — — — —
BLA No. O 9 - `r '
CORNER:
D APPROVED �7 (S 00°02-36"E 2390.85') FOUND
L FOUND GRAYUM PIPE
S 00°02'36"E 2390.89' AND ALUMINUM PLUG
-- \ C . I FOUND BRASS
OF COMMUNITr DEVELOPMENT MOMENT LINE TABLE
^ COURSE BEARING DISTANCE
o
1 S I6°59'20"W 5.00'
2 S 73°00'01"E 30.00'
LEGAL DESCRIPTION ! /
�
RESULTING PARCELS I AND 2 nF BOUNDARY LU✓E ADJUSTMENT No. 09—`t� c l ! !
M AS RECORDED UNDER AUDITORS FO.E No. 19 4114 11 RECORDS OF MASON ;z
COUNTY, IIASBINGTON.
(ORIGNIAL LEGAL DESCRIPTION) \ \- S� 00
Q I \E191.S8• / N
PARCEL L !
LOTS 8,9,AND I ,B OCK 75 OF THE PLAT OF THE TOWN OF ALLYN AS RECORDED IN 1 \
S VOLUME 1 OF S,PAGE 17,RECORDS OF MASON COUNTY,WASHINGTON.
TOGETJ3E ITHTHE WESTERLY IO FEET OF VACATED ALLEY ABUTTING THEREON. ``J/
RESULTANT PARCEL 1 QF-BOUNDARY LINE ADJUSTMENT No.03-46,RECORDED UNDER �� � `\_ 4
—r AUDITOR'S FI E No.18011 21,REC Of MASON COUNTY,WASHINGTON. \, 14
(`� 1 \� l T \S,�� P
BASIS O )`'' \1 1 i 3p'�3 S ° 16 � E�MERIDIAN BASED ON VOL E I O)P)ATS,PAGE„ CORDS OF MASON COUNTY, ! ! ° 71 S944
S9 E 130�, ��1 Y�\` l L
WASHINGTON. 1 /
I\ / PARCEL 1 \ /
PAR.No.12220-50-75008 \
$ cQ \ !
EQUIPMENT/PROCEDURES
/
1.THIS SURVEY WAS ACCOMPLISHED BY STANDARD,FIELD TRAVERSE PROCEDURES
USING A TOPCON GPT-9003A,3"TOTAL STATION. __%// i / S HOUSE 7 / QQ Oc"v 99 `
2.THIS SURVEY MEETS OR EXCEEDS THE MINIMUM SURVEYSTAN6ARDS PRESCRIBED
BY W.A.C.332-130-090.
GARAGE
NOTES
1. SEE OUR PREVIOUS SURVEYS OF RECORD FOR ADDITIONAL MONUMENTS FOUND / S 73
Q IN THIS SUBDIVISION. / �}/ ��O" ! ! !'
F I p0 pp• / ! OLD LINE
o �REFERENCE SURVEYS / � = L`� L2
1. VOLUME 30 OF SURVEYS,PAGES 19&20(BENCHMARK) �1 0 Al GARAGE
Z_ NZ 2. VOLUME 31 OF SURVEYS,PGE 136(BENCHMARK) m $ \ / NEW LINE
Q' 3. VOLUME 31 OF SURVEYS,PAGE 147(BENCHMARK)
4. VOLUME 34 OF SURVEYS,PAGE 29(BENCHMARK)
5. VOLUME 4 OF SURVEYS,PAGE 13(THORNTON) / HOUSE
6. VOLUME 16 OF SURVEYS,PAGE 2(THORNTON) SCALE:1•
><— 7. VOLUME 16 OF SURVEYS,PAGE 159(THORNTON)
8. VOUME 20 OF SURVEYS,PAGE 60(THORNTON) \\ \\ \
a•1n;= 9. VOLUME 29 OF SURVEYS,PAGE 27(BECHTOLT) 40 20 0 �0/ PAR.No.12220-50-75005
mow— S73° 00,
LEGEND LAND SURVEY LOCATION SU VEYOR S CERTIFICATE Benchmark Land Surveying
A SURVEY IN THE NW 114 OF THE SE 114 OF SECTION 20, TOWNSHIP W"s/n ap orrec�tly represents
• SET 5/8"REBAR&PLASTIC CAP, RPLS 33123 ,22 NORTH, RANGE I HEST, W.M., IN MASON COUNTY, WASHINGTON. /a stfrvey m by me or under R L.E BoundarySIId Construction Surveying
FOUND PER ROS 30/19-20,OR AS NOTED ,nly di con iri con for ce 01' WAS 'per
nvOSC vucnAM— with th re q cement o/the Q e~ c y
PROPERTY LINE
(XXX) RECORD BEARINGS AND DISTANCES S Rec ding A t t the Robert L. Emerson, PIS
a
AUDITORS CERTIFICATE RECORD OF SURVEY FOR: st of ; (360) 275-8838
Filed for record this day o/ te 20� RONNIE L O o3123 * P.O. Box 1526
AUDITORS INDEXING DATA at1351& Book__3St of Surveys at page 111 Ronnie Larson ;n NOVEMBER 09 arsnRp5.�o9 Allyn, WA 98524
QUARTER-QUARTER SECTION TOWNSHIP RANGE of the request of Rob t L. Emerson PL P.O. Box 1016 1�a I�' �% AL 6AL'�
Mason County Auditor All n, WA 98524 �4
NW 1/4 of the SE 1/4 20 22 NORTH 1 WEST Auditors File No. � y ROBERT L.EMERSON,PLS
Survey Record No. CERTIFICATE No.33123 // Drawing No.: 09-1350 Sheet 1 of I