Loading...
HomeMy WebLinkAboutBLD2009-01096 Storage - BLD Permit / Conditions - 2/28/2011 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Ir Shelton,WA 98584 flo RESIDENTIAL BUILDING PERMIT BLD2009-01096 OWNER: RONNIE LARSON RECEIVED: 12/31/2009 CONTRACTOR: LICENSE: EXP: ISSUED: 2/28/2011 SITE ADDRESS: 21 E WHEELWRIGHT ST ALLYN EXPIRES: 8/28/2011 PARCEL NUMBER: 122205075008 LEGAL DESCRIPTION: ALLYN BLK: 75 LTS 8-10 &VAC ALLEY ADJ PROJECT DESCRIPTION: DIRECTIONS TO SITE: Two story Storage Building. Lakeland Dr. and Wheelright south General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: 74 Type of Work: ACC Fire Dist.: No. of Stories: 2 Occ. Load: Building:336 Valuation: Building Height: Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline& Planning Information : y Make: Length: Ft. Front: W 100.0 Ft. Shoreline: Ft. Water Body: No Model: Width: Ft. Rear: E Ft. Slope: Ft. Shoreline Desi Side 1: E 5.0 Ft. 9.: Not Applicable Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee TW 12/31/200 $172.41 S12009000 Planning Review Fee TW 12/31/200 $205.00 S12009000 BLD Vio. Investigation Fee DLC 1/5/2010 $73.00 S12011000 Building State Fee DLC 2/7/2011 $4.50 S12011000 Building Permit Fee DLC 2/7/2011 $251.25 S12011000 ADJUST--Plan Check Fee DLC 2/7/2011 -$9.10 S12011000 Total $697.06 BLD2009-01096 Please referto the following pages for conditions of this permit. 1 of 4 Permit# MASON COUNTY BUILDING 111 426 W, CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance cam. G e 7-0 14 4i0 iy o is Left o��si�' G T a C2 fouAare hereby notifl tVat the above correiAidns shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑ This is not a complete inspection disasters.This is NOTa Date — ' '- CORRECTION NOTICE. � � - ,/ ,�_ Department Inspector Zz- ov* v No 01T ' 'iml* 014 ' ' THI , o T' * mr Permit# MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASH JNGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location ?-/ 5/- This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance Z?ilic..7- Z =s%off Y )C / 06-LC-.0Z d- ,ti l�aX Z 2 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent "natural/man made" ❑ This is not a complete inspection disasters.This is NOT a Date -/5�-��' Department �L� CORRECTION NOTICE. Inspector Z3 DO NnT RJ=MnV ' THI c T,--'m-G l 00 o CONCRETE MECHANICAL MANUFACTURED HOME D 0 Date By X 0 Footings !Setbacks Ribbons Gas Piping O o Interior Date By Interior-Date By Date By Z rnExtew Date By Exterior-Date �_ _ BSet-up Point Load t Isolated Footings INSULATION _ Date By Z Date By BG f SLAB INSULATION - Z Data By FIRE DEPARTMENT m Foundation Wails Floors -' Date By Date By Data By DECKS FRAMING walls Date By Date By Data By PROPANE TANKS PLUMBING vault Data _..�_._13?!'_____ Date By OTHER Groundwork Attic Type. Data By Date By Dato By D.w.v s DRYWALL Type Int.Brace Wail Date By W Date By Dale By FINAL INSPECTION 0 v Water Line Fire Separation Dale By Date By Data By p m to Pass or Request Inspect, o 0 Type of insp. Fail Date Date Done By Comments CD CD. S7 p n'/4 a 77— im j -.-LAr �,>.,. esr� Gc, f� f S/�r 4-IS T L1 C 0 J cot", MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street — _ PO Box 186, Shelton, WA 98584 1854 www.co.masonma.us Shelton (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269 April 13,2010 Ken and Ronnie Larson PO Box 1016 Allyn, WA 98524 Re Building Permit Number: BLD2009-01096 Dear Mr.And Mrs. Larson, Thank you for submitting the building permit application referenced above. In order to complete the building department review additional information will be needed which is listed below. PLAN REVIEW REQUIREMENT COMMENTS: Qs ased upon information available to our office the location of the structure is placed along the fence,which also the property line. The survey completed by Mr. Robert Emerson in December 2009 and recorded under Auditor File number 1951410 does not show the location of the fence or the shed/tree house. When I contacted Mr.Emerson in December 2009 to discuss the survey he informed me that the property line is located at the fence line. Please provide documents demonstrating that the location of the shed/tree house meets the required setbacks for the planning department and building code. 2. Based upon the documents submitted for the 2-story shed/tree house the prescriptive requirements for shear wall bracing specified in the 2006 International Residential Code (IRC) Section R602.10 cannot be achieved unless the structure is modified to meet IRC requirements. Braced wall panels are required to be marked on plans and placed in all structures to address seismic and wind conditions in our area. Note that in seismic design category D2 the first floor of a 2-story prescriptive structure requires braced wall lines that amount to 55%of the wall length. In addition braced wall panels shall not-exceed 25-ft on center in plane and in the transverse direction. Where prescriptive requirements are not possible those portions that do not comply shall be designed and constructed in accordance with accepted engineering practice. When a lateral design is necessary a Washington State licensed design professional must prepare the design. 3. On April 8,2010 our office received a partial elevation plan showing the wall-framing layout for a one- story structure and a foundation plan showing a 10-inch x 12-inch footing. In order to properly evaluate the structure a full set of legible construction plans, drawn to scale, shall be required and shall include the following: a. Foundation plan, including information showing that the foundation meets or exceeds minimum prescriptive requirements or provide an engineered design of the foundation system. See information enclosed. b. Cross-section of the structure from foundation to roof, c. Deck and floor framing layout including joists and support beams for the upper floor and deck, d. Floor plan showing the use of ALL rooms,opening sizes of windows and doors, header information,shear wall locations and type,etc. e. Stairway framing information showing access to upper floor, f. Roof framing details, including rafters sizes and layout,beam sizes and span,etc. When the requested information is received staff will review the documents and evaluate for code compliance. Generic information is enclosed to help you identify the information needed. 4. Please provide a completed Washington State Energy Code application in order to identify that the structure, if heated,meets minimum energy code requirements. To complete an engineered analysis your design professional will need the following information: Snow load: 25 psf Wind load: 85 mph, exp`B"unless designated otherwise Seismic zone: D2 When you have compiled the requested information please submit it to the Mason County Building Department, attention D. Coker. Please respond to comments, in writing,in the order listed. Revisions,required as a result of the engineered design,must be transferred onto proposed building plans. Where required,please return two sets of revised plans and documents along with two sets of calculations. If you have questions please contact me at(360) 427-9670 ext. 510 or via e-mail at: dlc@co.mason.wa.us Sincerely, Debbera Coker Mason County Building Department Plans Examiner Word/BLD2009-01096 Encl.: Plan detail information Prescriptive foundation detail Washington State Energy Code compliance form ason County Planning Department imoio Case Activity Listing 9:24:35AM:35AM Case #: BLD2009-01096 P10 Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By BLDA010 Application Received 12/31/2009 None 12/31/2009 TW BLDBI 10 Building Plan Review 12/31/2009 None HOLD DLC DLC 1/6/2010 DLC Contacted the surveyor,Mr.Emerson,to discuss location of the property line. According to the surveyor the site plan may be incorrect as the fence is supposed located on the property line,see recorded survey af#1951411. Notified the planner who will follow-up and notifty bldg dept.of findings. Also,LMOR for owner notifying them of the findings and that if the structure were to be approved as proposed additional fire resistive construction will be required. The owner was also notified that there are also construction questions. Specifics were not provided in the voice mail message. NOTE: It appears that a lateral analysis will be required. A floor/story was added to an existing storage structure. When this occurs the lower floor must comply with code requirements inclUding existing foundation system. do BLDB130 Planning Review 12/31/2009 None AHB 1/6/2010 DLC Please notify bldg dept.when approved. do 1.6.2010 Page 1 of 1 CaseActivity..rpt From: Debbera Coker To: Borden, Allan Date: 1/7/2010 12:54 PM Subject: Larson separation Hi Alan... Concerning the Larson separation there is actually a state WAC that allows 3-ft to property line without requiring fire resistive construction and even less depending upon the use of the structure. A portion of the amendment is pasted below. LOCATION ON LOT R302.1 Exterior Walls. Exterior walls with a fire separation distance less than 3 feet(914 mm)shall have not less than a one- hour fire-resistive rating with exposure from both sides. Projections shall not extend to a point closer than 2 feet(610 mm) from the line used to determine the fire separation distance. Exception: Detached garages accessory to a dwelling located within 2 feet of a lot line may have roof eave projections not exceeding 4 inches. Projections extending into the fire separation distance shall have not less than one-hour fire-resistive construction on the underside.The above provisions shall not apply to walls which are perpendicular to the line used to determine the fire separation distance. Exception:Tool and storage sheds,playhouses and similar structures exempted from permits by R105.2 are not required to provide wall protection based on location on the lot. Projections beyond the exterior wall shall not extend over the lot line. V11���LW�.GNT Si Lr N F, U7 c5 2 I E WAMWRI a 4T ST. Ai-L` V I WA q RsD4 d � Q ua kW3 OZ — '6I 6uiu� tpeg wowpag wo��+ apa8 APPROVED Z U-rdBu^� ASON COUNTY DCD PLAN °!1NGi rn � jeoz smn SITE PLAN REQUIRED TO BE ON 11t azz woos o CHANGES SUBJECT TO APPROVAL woapeg -� '"'°°'peg IG!wej Date-6-1ceud do4s4ioM �p t, T ,ti ZZ RECEIVED � z c" APR 19 2010 ` 14 ,� 4 N 1 426 W. CEDAR ST. FEN TOPOGRAPHY PROFILE: PKc�I°� LIN ' • Direction: Scale: Approval:for office use Building Permit number: ' j« = 2( ` Building: Owner/Applicant:J<15K $ "NNIE t.P+95Z-K => Date of Planning: Parcel Number: , V I ap-50-� `7�oag A f application: Env. Health: I U ! Q w y 44112" 4-4112" -x o --------4x$---------------- rt L /-/-/-/� ►) 4 x V ' ,ti I I o b I to s r / I —————— ,3-0 (()po I 4' 1 6=10 5✓ /" I t/f -------------- ------- �:l o rn 2- x Lf Ken& Ronnie Larson ' I'0 Box 1016 Allyn,WA 9&524 2I E. Whee I wrl Jh-t St, U T� 8"Rail --- - -------------- 4'4 D"Rail _ 15'-9" ao 3=51/16" 1i Z,-S„15/16" - - 1-8" 3-0•xf'8• \ r8•xe 8• c _ c � s i N ao 1 T-5'; RidgeHt=3'-1 D 11116" h Q) cv O A OD CY) a --- ----- 6L1-13116"_ — - 4'-1"Rail Ah Ask r� Ken& Ronnie Larson PO box 1016 Allyn,WA 98624 om 23 E VJ;-weIvv-j h+ �t I I I I � I I I � I I I I I I � I I I � I I I I I I I I I I I I I I i I ------------------------------- O.8' Ken& Ronnie Larson `, N PO box 1016 Allyn,WA 98524 2( r-- Whafar''j(lf- St ---------------- X-0, V6• / ?g•Xgg w w ►V O -------------------------- 4 h O N Ken& Ronnie Larson N PO Box 1016 AIlyn,WA 98624 e� 2.[ E 1n1 .!w�r9hf Sf �» . � z9��` . v -. e a:? v ; . . . . . . , : . Ken & Ronnie Lmm ` PO box]m a «y Allyn,&a 98624 2 E- Wk&j wi-i/K c ~ �1 t �, Ken& Ronnie Larson W-4 PO Box 1016 _'.._-4— Allyn,WA 98524 21 t Wke-t!wr)"9 ht St: Ken & Ronnie Larson PO Box1016 Allyn,WA 98524 m 2( G 4"V41e2Jv4rj' 40 X 1 � aj:ro .Y > A i 4 f Ken& Ronnie Larson PO Box1016 Allyn,WA 95624 'LI E WF1eel1VC(j'I+ St. y o i Ken& Ronnie Larson ``0 4 PO Box 1016 Allyn,WA 98624 u wght st 40 vt H&H tT 10/15/2009 10/15/2009 i tf 10/15/2009 10/15/2009 10/15/2009' c. ,ip r �*1 z- A f r� i �� Vp jr11F— J Ar r,�� vim• +. � 't' � rj - .,ter' Al_ y ;, .fry t WHEEL—WRIC-14T ST i !✓S) { - 3 U, l �e -� E3 CS> -- wOC,6 4u3 IN - 61 &xwa Utea woaPae r_ 7 uau uwaPag a6eje(� � woos tiutnr� NO z sign "tl ZZ 'V wooa o w�Pee /4lweJ wooipagTt do M RECEIVED ti .£I ,y f)Ecs� y APR � 9 1010 426 W, CEDAR ST_. TOPOGRAPHY PROFILE: rP90,15 LINE I V Building Permit number: Direction: Scale: Approval: for once use 1 = 20` Building: Owner/Applicant: K15K 4 "NNIL 1.P+R-441,1 � Date of Planning: Parcel Number: , V ��50� '���OB r application: Env. Health: Page 1 of 1 ML. s ' M e Y,y b y t Sa ,., �x" ✓^., x pa Y kg ,• i ,v 3 file://Q:\Documents\200910\BCC20090.017\6\BCC2009-00176, TAKEN 10.15.2009#2.JPG 1/6/2010 Page 1 of 1 =r Ow A �s v> ?L � III III q file://Q:\Documents\200910\BCC20090.017\6\BCC2009-00176, TAKEN 10.15.2009#1.JPG 1/6/2010 (2( /10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page 1 l From: Debbera Coker To: Larson, Ronnie CC: McFarland, Genie Date: 2/10/2011 8:50 AM Subject: RE: Ken & Ronnie Larson project number 10.310 The fees paid when the permit was submitted addressed plan review fees related to building department and planning dept. only. The building permit is collected when the permit is issued along with other fees associated with the case, which is the site investigation fee charged as a result of the correction notice posting. Sorry that you were not aware of the permit fees when the permit was submitted. When the permit was submitted we were very concerned about the location of the structure to adjacent properties and really focused conversations to that issue, not on fees. Our Department is fee supported, dependent upon the plan review fee for time spent preparing the documents for issue and the permit fee which is related to actual inspections in the field. The fees are adopted by our Commissioners. The permit fee DOES NOT include an enforcement fee (double permit fee) because you responded to the correction notice as requested. Your permit can remain here until the fees are paid up to 6 months. Extensions can be granted when requested due to hardship. If that is the case please keep us posted, in writing, not to exceed 6 months each time. We know that you are anxious to finish this project. Sorry to add another obstacle. The adopted fees are not negotiable and out of our hands. Debbera Coker Mason County Building Department Building Inspector IV/Code Enforcement Phone: (360)427-9670 ext 510 FAX: (360) 427-7798 e-Mail: DLC@co.mason.wa.us PO Box 186 426 West Cedar Street Shelton, WA 98584 >>> Ronnie Larson <einnor64CcDhotmail.com> 2/9/2011 7:48 PM >>> Thank you Debbera, again, for your help. I did get a call from a Jeannie who said we could pick up our permit now for only $319.65??which was another shock to me because I thought we paid all the fees up front and now I don't have a dime and don't have $300 to pick up the permit!! It will take me a month or two to come up with that right now, I don't even have grocery money left this month and it's only the 9th. Can you tell me what these fees are for? You can call me at work at (360)277-2166 between 7 and 2 or just email me back. Thanks, Ronnie Larson > Date: Mon, 7 Feb 2011 08:07:46 -0800 > From: Dlc co.mason.wa.us > To: einnor64(a)hotmail.com > Subject: RE: Ken & Ronnie Larson project number 10.310 > I plan to work on your project today. When I am completed I will make sure that staff knows that you are anxious. They will call when processed, typically within 24-hours after the file is complete. > Mr. Hodge was extremely helpful. You are right WOW! (2/10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page 2 > >>> Ronnie Larson <einnor64(@hotmail.com> 2/5/2011 6:23 PM >>> > Dear Debbera, > WOW is all I can say, since this is all Greek to me but does this mean we'll get our building permit now and can finish? > Thanks for all your help! > Ronnie Larson > > Date: Thu, 3 Feb 2011 16:03:57 -0800 > > From: Dlc co.mason.wa.us > > To: iohnCa�hodgeengineering.com > > CC: einnor64(ahotmail.com > > Subject: RE: Ken & Ronnie Larson project number 10.310 > > Looks good to me. You are awesome. Thank you for taking care of the Larson's. » > > Debbera Coker > > Mason County Building Department > > Building Inspector IV/Code Enforcement > > Phone: (360)427-9670 ext 510 > > FAX: (360)427-7798 > > e-Mail: DLC(&co.mason.wa.us > > PO Box 186 > >426 West Cedar Street > > Shelton, WA 98584 > > >>> "John Hodge" <johnahodgeengineering.com> 2/3/2011 3:33 PM >>> > >Assuming 1500 psf bearing capacity for the soil a 10"footing will provide > > (10/12)x1500 = 1250 pound per linear foot. > > The foundation has 4' of tributary roof load and 4' of tributary floor > > loading each floor. The load to the foundation is 4x(15+30) + 8x(10+40) _ > > 580 pounds per linear foot, > > 1250 > 580 The 10"wide footing is adequate. > > The frost depth is a jurisdiction determination. However, I've attached a > > quick analysis of the footing as a grade beam. With the 580 pounds per > > linear foot it can span 8'. So if the ground did freeze and the foundation > > was supported at only locations 8' apart it would be 40% loaded. In my > > professional opinion the foundation can support the structure during a frost > > heave. > > Hope this helps. > > John > > John Hodge P.E. > > Hodge Engineering, Inc. > > 2615 Jahn Ave NW Suite E5 (2/10/2011) Debbera Coker- RE: Ken & Ronnie Larson project number 10.310 Page J J > > Gig Harbor, WA. 98335 > > 253-857-7055 fax 857-7599 > > -----Original Message----- * > From: Debbera Coker fmailto:Dlc(d,)co.mason.wa.usl > > Sent: Thursday, February 03, 2011 3:08 PM > > To: John Hodge > > Subject: RE: Ken & Ronnie Larson project number 10.310 > > Did not receive this plan. Helpful....I can work with everything but the > > foundation. > > The foundation does not meet prescriptive IRC specifications (15"width for > > a 2-story). Frost depth is 12-inches, according to plan the footing is 10" > > wide x 12" high. Is there anything an engineer can do? > > Debbera Coker > > Mason County Building Department > > Building Inspector IV/Code Enforcement > > Phone: (360)427-9670 ext 510 > > FAX: (360) 427-7798 > > e-Mail: DLC@co.mason.wa.us > > PO Box 186 > > 426 West Cedar Street > > Shelton, WA 98584 MASON COUNTY PERMIT NO.. 10 (4 BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 185, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482- Ck On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner KE-N_A, RONN/E LARSON Company Name SE-LL' Mailin Address PO OOX 10142 Mailing Address Same as aDol,can f City LL�N State A Zip Code 9 52- City State Zip Code Phone 3 0 d77- 0 Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address P/nQor(o F tiofrna%/•con) E Mail Address Drivers Lic.# 4AQ$0RE3(o9P4 DOB /OL211,4 Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic n0 Existing Septic no Connect to Water System " Name of Water System Well Water System Name of Water System U PARCEL INFORM TI N- 12 Di it Parcel No G Fire District Legal Description ` D ��`�> �U �� �� A/Ivn 1/oJvrle / c( �I41S� �q / 7, I-ec-cy4s oEMaSon 60,,1 1 Site Address(Please include street name,street npmber and city 2l E (Nhe�lwr��>� St All,,r, (n/A 4g5a� Directions to site�yT 3 �o �/a"S f/ eo+rtP� ° F✓ans Will timber be cut and sold in parcel preparation?Yes o Is property within 200'of Saltwater klA> Lake wv River/Creek v>� Pond VIA Wetland ►w Seasonal Runoff hA Stream K.0 Slopes or Bluffs ] 15% hA Is this permit submittal the result of a Stop Work Notice orrec ro otice or other enforcement action?( es to TYPE OF JOB - New _Add Alt Repair Other Ia� PRIMARY RESIDENCE ❑ SEASONAL 0 Use of Building 3W + I r-"--►'ovse Describe Work No. of Bedrooms 0 No. of Bathrooms 0 Square Footage- 1 st Floor /92 2nd Floor /92- 5F 3rd Floor Basement Deck I s Covered Deck — Other _ Sq.ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION -Make- Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Admowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holier or any other party in interest regarding this application or the work proposed in theft application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to fhe above described property and structure for review and inspection. PROOF CONUA N OF WORK IS BY MEANS OF A PROGRESS INSPECTION. x ��NTI11(t 1",4 L Date: Owner/Owners Representative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department I 0 Planning Department X cj' f X /G = Environmental Health Department 4, x g Public Works Department Fire Marshal FEES Building Permit Fee ` 5/ 5 Site Ins ection i Plan Review Fee Z ,0 v> > EH Review Fee Plumbing& Base Fee Planning Review Fee Mechanical& Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES 3 :3c, �e cLl L4 81, 2 y J(o 0 122205800019 122205066005 122205067005 122205800020 A. ��'•� �` . - � 122205067002 O 122202400000 122205068002 #+ 122205069002 f 'T',�I ♦ s.r�. � ' 122205067001 �122205068001 12 !4OWOOJF 122205069001 f ar R �D CO �" _ w ®R 122205070001 o 2 122205075008 T-2 2ZNti �► � ; 122205075005 �• l 122205010000 r y > 122205073006 122205074001 4T 122205075002 Ai o , r 1 `a.} s; ♦ 122205073001 `w. i � �-: _ � f � 1222050720011 . . _ 122205077001 f f ♦12220006001000, - : 122205079006 w 122205080009 f 1 inch = 100 feet 777 1 inch = 0.02 miles �d' ►row— —. — — — --- — — — — — — — — — — — — BLA No. O 9 - `r ' CORNER: D APPROVED �7 (S 00°02-36"E 2390.85') FOUND L FOUND GRAYUM PIPE S 00°02'36"E 2390.89' AND ALUMINUM PLUG -- \ C . I FOUND BRASS OF COMMUNITr DEVELOPMENT MOMENT LINE TABLE ^ COURSE BEARING DISTANCE o 1 S I6°59'20"W 5.00' 2 S 73°00'01"E 30.00' LEGAL DESCRIPTION ! / � RESULTING PARCELS I AND 2 nF BOUNDARY LU✓E ADJUSTMENT No. 09—`t� c l ! ! M AS RECORDED UNDER AUDITORS FO.E No. 19 4114 11 RECORDS OF MASON ;z COUNTY, IIASBINGTON. (ORIGNIAL LEGAL DESCRIPTION) \ \- S� 00 Q I \E191.S8• / N PARCEL L ! LOTS 8,9,AND I ,B OCK 75 OF THE PLAT OF THE TOWN OF ALLYN AS RECORDED IN 1 \ S VOLUME 1 OF S,PAGE 17,RECORDS OF MASON COUNTY,WASHINGTON. TOGETJ3E ITHTHE WESTERLY IO FEET OF VACATED ALLEY ABUTTING THEREON. ``J/ RESULTANT PARCEL 1 QF-BOUNDARY LINE ADJUSTMENT No.03-46,RECORDED UNDER �� � `\_ 4 —r AUDITOR'S FI E No.18011 21,REC Of MASON COUNTY,WASHINGTON. \, 14 (`� 1 \� l T \S,�� P BASIS O )`'' \1 1 i 3p'�3 S ° 16 � E�MERIDIAN BASED ON VOL E I O)P)ATS,PAGE„ CORDS OF MASON COUNTY, ! ! ° 71 S944 S9 E 130�, ��1 Y�\` l L WASHINGTON. 1 / I\ / PARCEL 1 \ / PAR.No.12220-50-75008 \ $ cQ \ ! EQUIPMENT/PROCEDURES / 1.THIS SURVEY WAS ACCOMPLISHED BY STANDARD,FIELD TRAVERSE PROCEDURES USING A TOPCON GPT-9003A,3"TOTAL STATION. __%// i / S HOUSE 7 / QQ Oc"v 99 ` 2.THIS SURVEY MEETS OR EXCEEDS THE MINIMUM SURVEYSTAN6ARDS PRESCRIBED BY W.A.C.332-130-090. GARAGE NOTES 1. SEE OUR PREVIOUS SURVEYS OF RECORD FOR ADDITIONAL MONUMENTS FOUND / S 73 Q IN THIS SUBDIVISION. / �}/ ��O" ! ! !' F I p0 pp• / ! OLD LINE o �REFERENCE SURVEYS / � = L`� L2 1. VOLUME 30 OF SURVEYS,PAGES 19&20(BENCHMARK) �1 0 Al GARAGE Z_ NZ 2. VOLUME 31 OF SURVEYS,PGE 136(BENCHMARK) m $ \ / NEW LINE Q' 3. VOLUME 31 OF SURVEYS,PAGE 147(BENCHMARK) 4. VOLUME 34 OF SURVEYS,PAGE 29(BENCHMARK) 5. VOLUME 4 OF SURVEYS,PAGE 13(THORNTON) / HOUSE 6. VOLUME 16 OF SURVEYS,PAGE 2(THORNTON) SCALE:1• ><— 7. VOLUME 16 OF SURVEYS,PAGE 159(THORNTON) 8. VOUME 20 OF SURVEYS,PAGE 60(THORNTON) \\ \\ \ a•1n;= 9. VOLUME 29 OF SURVEYS,PAGE 27(BECHTOLT) 40 20 0 �0/ PAR.No.12220-50-75005 mow— S73° 00, LEGEND LAND SURVEY LOCATION SU VEYOR S CERTIFICATE Benchmark Land Surveying A SURVEY IN THE NW 114 OF THE SE 114 OF SECTION 20, TOWNSHIP W"s/n ap orrec�tly represents • SET 5/8"REBAR&PLASTIC CAP, RPLS 33123 ,22 NORTH, RANGE I HEST, W.M., IN MASON COUNTY, WASHINGTON. /a stfrvey m by me or under R L.E BoundarySIId Construction Surveying FOUND PER ROS 30/19-20,OR AS NOTED ,nly di con iri con for ce 01' WAS 'per nvOSC vucnAM— with th re q cement o/the Q e~ c y PROPERTY LINE (XXX) RECORD BEARINGS AND DISTANCES S Rec ding A t t the Robert L. Emerson, PIS a AUDITORS CERTIFICATE RECORD OF SURVEY FOR: st of ; (360) 275-8838 Filed for record this day o/ te 20� RONNIE L O o3123 * P.O. Box 1526 AUDITORS INDEXING DATA at1351& Book__3St of Surveys at page 111 Ronnie Larson ;n NOVEMBER 09 arsnRp5.�o9 Allyn, WA 98524 QUARTER-QUARTER SECTION TOWNSHIP RANGE of the request of Rob t L. Emerson PL P.O. Box 1016 1�a I�' �% AL 6AL'� Mason County Auditor All n, WA 98524 �4 NW 1/4 of the SE 1/4 20 22 NORTH 1 WEST Auditors File No. � y ROBERT L.EMERSON,PLS Survey Record No. CERTIFICATE No.33123 // Drawing No.: 09-1350 Sheet 1 of I