Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2012-00754 SFR - BLD Permit / Conditions - 10/29/2012
Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 lF Shelton, WA 98584 - Pis RESIDENTIAL BUILDING PERMIT BLD2012-00754 OWNER: KEN WOODWARD RECEIVED: 10/1/2012 CONTRACTOR: LICENSE: EXP: ISSUED: 10/29/2012 SITE ADDRESS: 50 E LAKESHORE DR ALLYN EXPIRES: 4/29/2013 PARCEL NUMBER: 122205000018 LEGAL DESCRIPTION: LAKE LAND VILLAGE DIV 1 LOT 18 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR ST RT 3 TO ALLYN, L ON LAKELAND DR, L ON LAKESHORE DR TO SITE ADDRESS ON THE RIGHT SIDE General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:2,574 Valuation: $ 277,758.82 Building Height: Occ. Status: Primary Basement: cov porch 250 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 20.0 Ft. Shoreline: 59.0 Ft. Water Body: ANDERSON LAKE- Rear: W 59.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: N 5.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: S 5.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 3 Furnace<100K 1 Plan Check Fee GMM 10/1/2012 $ 1,257.46 S1201200000001 Lavatories 5 Heat Pump 1 Planning Review Fee GMM 10/1/2012 $205.00 S1201200000001 Bath Tubs 2 Ventilation Fan 5 EH Plan Review KKK 10/1/2012 $ 103.00 S6201200000001 Showers 1 Propane Tank 1 Water Adequacy Plan Revi KKK 10/1/2012 $ 103.00 S6201200000001 Water Heaters 1 Gas Outlets 4 Building State Fee DLC 10/25/201 $4.50 S2201200000001 Clothes Washer 1 Fireplace 1 Building Permit Fee DLC 10/25/201 $ 1,990.55 S2201200000001 Kitchen Sink 1 Exhaust Hood 1 Mechanical Permit Fee DLC 10/25/201 $255.90 S2201200000001 Dishwasher 1 Dryer Vent 1 Mechanical Base Fee DLC 10/25/201 $28.50 S2201200000001 Hosebibs 4 Plumbing Permit Fee DLC 10/25/201 $ 136.70 S2201200000001 Laundry Tray Plumbing Base Fee DLC 10/25/201 $24.70 S2201200000001 ADJUST—Plan Check Fee DLC 1 012 5/2 0 1 $36.40 S2201200000001 Total $4,145.71 BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2012-00754 CONDITIONS FOR BLD2012-00754 1) Approved/ er dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 12 2) The prdposed project must be consistent with II applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County shoreline Master Program. X 3) Prior to final approval, all upland areas distu bed or newly cre t d by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 4) Temporary erosion control measures must be implemented to prevent water quali egr dation of adjacent waters or properties. Silt fencing must be installed and maintained until upland vegetation has become established. X 5) All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 6) Xoncr � I chate from approved construction must be contained during pouring, such that watdr quality degradation of adjacent waters does not occur. 7) The applicant acknowledges that this development was sited such that further shore protection measures will not be required for protection of the proposggd residence and appurtenant structures. X id y 8) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Appr v d Sit Plan"to ensure these structures are shown and meet the setback conditions listed. X 9) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these stru tures)meet the setback conditions listed. X ✓ 10) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 2 of 7 11) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800- 47-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 12) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depart prior to any further inspections being performed or approvals granted. X 13) Own r/A is esponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 14) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. Thg permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal ,gyp ed documents will result in failure of required building inspections. X ��ls 15) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not b granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building nt prior to any further inspections being performed or approvals granted. X 16) Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option II, Window(Max U-Factor):0.32, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table 9-1 shall be completed: Table 9-1, option 1A: Heat pump 8.5 HSPF or better OR LP furnace AFUE 92% or better. BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 3 of 7 17) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area(SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate" and are available in '/<or Y sheets. The Mason County Permit Center will also have some available. X 18) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Refere WSEC 505. X 19) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X 20) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X 21) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acl wledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 4 of 7 22) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charge shill be collected by the Building Department prior to any further inspections being performed or approvals granted. X f/ 23) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permits oc tion. X 24) Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and IMC. Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results(Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in accordance to WSEC Section 1411. X 25) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. /s X BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 5 of 7 26) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinanpe or.regulation, must be reviewed and approved by Mason County prior to construction. X 27) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENTAND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector a be made prior to requesting additional inspections. 28) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X / 29) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of ins ection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be u u it the final inspection has been performed and approved by a Mason County building inspector. X 30) All property lines shall be clearly identified at the time of foundation inspection. X l� 31) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Cou or inances and building regulations. X / 32) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prev nted action from being taken. No more than one extension may be granted. X / 33) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM X ROI�. X BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 6 of 7 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuat' n of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of M son County ac ess to the above described property and structure for review and.inspection. OWNER OR AGENT: DATE: BLD2012-00754 Please refer to the following pages for conditions of this permit. Page 7 of 7 r7 30.5�4 F 0 J 16low �' pC I o �QP>4 n c �I ti i 1 _ 5 ABA { � Zo A BA � �µ BUILDING MASON COUNTY PERMIT N011 ej _0 12, BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton(360) 427-9670- Belfair (360)275-4467- Elma(360) 482-5269 _ 6 P- -All 'y All 'y On the web www-co.mason.wa-us APPLIC I FO TION CONTRACTOR INFORMATION Owner Company Name A dress �', �- Mailing Address Mailing City 8�Y>j State - Zip Cods at City State Tip Code Phone-- 7�2�7U�bther Ph. Phone Other Ph. lien/Tote Holder Y� Contractor Reg.# Exp. E mail address ' ✓ /�L• E Mail Address Drivers Lic.#kJ i`J' DOB Drivers Lic.# DOB _AQSEPTIC/WATER SYSTEM INFORMATION-Connect to Newatir Existing Septic Connect to Water System Name of Water System � yL1A4 r__1j Well Water System Name of Water System PARCEL INFORMATION- 12 Digit Parcel No '� U� Fire District Legal Description n .l u./ Site Address (Please include street name,street number and city) Directions to site a.r T t�T 2 4 V Will timber be cut and sold in parcel preparation?Yes No is property within 20Q' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yeo TYPE OF JOB-Newer_Add Alt Repair Other PRIMARY RESIDENCE JR SEASONAL ❑ Use of Building Describen W�rk g/W�L10 No. of Bedrooms No.of Bathrooms lam'Square Footage-1 stn Floor �4Z� 2nd Floor 3rd Floor Basement Deck Covered Deck 4A-D Other Sq.ft. Garage Attached etached —Carport - Attached Detached MANUFACTURED HOME INFORMATION-Make Model Year Length Width Serial No. No.of Bedrooms No-of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BULDS1 A:imMadges submission of inac=Bte rtamsa5on may result in a sbp work order or pemit rewcafion.AcknuMedgement of Mich is by scgnatze below.I declare that I am the owner,owners legal represant-fn2,or the oontacdnr.I further declare that I am erffled to receive this permit and to do the work as proposed in the applicabon.I declare that I have obtained the permission from all the necessary parfies tf permission is mired from any easement hoider,or any other party in interest regarding this application or the work proper in the applkz6on,I have obtained p..mmission from them to apply for this pemvT and conduct the work proposed. The owner or agent on owners behalf,represents that the tIom�on provided' acaradB and grants employees of Mason county amass to the above described property and stuch.rre for review and inspection. PROOF CONTINUMNOWORK IS Y MEANS OF A PROGRESS INSPECTION. X Date.. Owner l owners Representative I contactx Cmcicate which one) F R OFFICIAL USE BEYOND THIS POINT Accepted b . Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Buiidrng Department /D - Planning Department Environmental Health Departrne Public Works Department Fire Marshal FEES Buildinq Permit Fee Site inspection Plan Review Fee a 4,0 o� 8 EH Review Fee Plumbing& Base Fee 70�a "Planning Review Fee Mechanical &Base fee o{ J�J` D , W Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee AAOX Pre-Paid at Submittal Valuation TOTAL FEES BUILDING .( PERMIT Nahla o21D 12 - MrI 5 MASON COUNTY Al to n PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar•P.O. Box 186, Shelton, WA 98584 Shelton(360)427-9670•Belfair(360)275-4467• Elma(360)482-5269 P ( _ (��(� On the web www.co.mason.wa.us APPLICANT INFO MATION CONTRACTOR INFORMATION Owner Company Name Mailing Addres - Mailing Address City-&i-ceb --State WA Zip Code City State Zip Code Phone Other Other Ph Phone Other Ph. Lien/Title Holder ►'L Contractor Reg. # Exp. E mail address 1,LC-)Q'� LCiOrt, E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to Existing Septic. Connect to Sewer System Name of Sewer System NewSeptc 1 PARCEL INFORMATION-12 Digit Parcel No z'© CX>O Fire District Legal Description 1L l -' 7 Site Address(Please include street name, street number and city) r Directions to site ,�,� l vu{ 'cry IJ o 13 S 7-fbl' O 0 X i6.kPr — C ' Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units- 1 st Floo 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture o.of Fixtures Fees Fuel Type:Electdc_>_� LPG Natural Gas—Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs �' Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer 1 Gas Outlets r Kithen Sinks Wood/Gas/Pellet Stove Dishwasher �— Kitchen Exhaust Hood 7-_ Hosebibs Dryer Vent Otherz-4,orado 7 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provicl ccurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROD CONTINUA OF ORK I MEANS OF A PROGRESS INSPECTI N. X Date: IZ/ / z, 7Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted b Planning Pd Ck# Date fib- - l Bid Pd Receipt No. DEPARTME TAL REVIEW APPROVED DENIED NOTES Building Department Occ Group—Type Constr. Planning Department Environmental Health Department FEES Plumbing &Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES