HomeMy WebLinkAboutPAR2015-00030 - PAR Letters / Memos - 9/2/2015 t `
MASON COUNTY (360)427-9670 Shelton ext.352
Co
� DEPARTMENT OF COMMUNITY DEVELOPMENT (360) 275-4467 Belfair ext. 352
BUILDING• PLANNING• FIRE MARSHAL (360)482-5269 Elma ext. 352
— Mason County Bldg 8, 615 West Alder Street
Shelton, WA 98584 www.co.mason.wa.us
RE: Pre-Submission Conference
PAR2015-00030
Parcel Number: 12220-24-60040/12220-50-76000
Dear Applicant,
Please find enclosed a computer-generated report summarizing the results of your pre-submission
conference on 9/2/2015 if you have questions regarding the summary report,please do not hesitate to call
the appropriate staff member.
The various staff members,the departments they represent and their telephone extensions are listed
below:
DEPARTMENT STAFF MEMBER EXTENTSION INITIALS
Fire Inspector/Comm. Dev. Jeromy Hicks 282 JNH
Building/Comm. Dev. Trish Woolett - TW
Environ. Health Spec./Public Health Alex Paysse 279 ALP
Eng. Tech/Public Works Fred Perryman 625 FJP
Planner/Comm. Dev. Grace Miller 360 GBM
Planner/Comm. Dev. Rebecca Hersha 287 RDH
Planner/Comm. Dev. Kell McAboy 365 KJM
Planner/Comm. Dev Michael MacSems 571 MMS
Stormwater Eng./Public Works Loretta Swanson 769 LGS
The comments are based on the project discussed during the pre-submission conference. Any changes or
alterations to the original proposal may significantly change the permit requirements. In this case a
second pre-submission conference will most likely be required to discuss the changes.
Information provided to the prospective applicant during the pre-submission conference is based on
Mason County regulations in effect at the time of the conference. Revised or new regulations could affect
a future development application. A pre-submission conference does not vest a future development
application.
If further assistance is needed please contact us at 360.427.9670 ext. 352 or www.co.mason.wa.us.
Case Activity Listing 3:09:7/13/2016
2016
Case #: PAR2015-00030
i Parcel #: 122202460040
Description: PRE-APPLICATION CONFRENCE FOR A NEW CHURCH 11,528 SF
PARA 10 Application Received 8/26/2015 None GMM 8/26/2015 GMM
PARB20 Building Plan Review 8/26/2015 None 8/26/2015 GMM
PARB60 Fire Marshal Review 8/26/2015 None 8/26/2015 GMM
PARB40 Environ.Health Review 8/26/2015 9/2/2015 None DONE ALP 9/2/2015 ALP
EH review will be required for building permit of new facility. For EH review,a completed water adequacy form and sewer adequacy form will be required If proposed facility does not plan to serve food4o
the public,then a commercial kitchen or food operation permit will not be required If any changes are made to the kitchen plan,than what was discussed,please contact Cody Lund,MCPH food specialist.
You can contact Mason County Utilities to discuss the sewer adequacy form and plans Both Adequacy forms were emailed to applicant
PARB50 Public Works Review 8/26/2015 9/15/2015 None DONE FJP 9/15/2015 FJP
Any new road access will require a Road Access Permit(RAP)
RAP can be picked up at Public Works and needs to be finalized prior to to bldg permit final approval
Page I of 2 CaseAetivity..rpt
16
Case Activity Listing 3:7/13/13/20/2016
Case #: PAR2015-00030
i Parcel #: 122202460040
Description: PRE-APPLICATION CONFRENCE FOR A NEW CHURCH 11,528 SF
ctivltv,. escrl tlon_. _ ate 1 Date ti t
PARB10 Planning Review 8/26/2015 9/2/2015 None DONE AHB AHB 10/29/2015 AHB
APPLICANT:NORTH BAY LUTHERAN CHURCH
MEETING DATE/TIME:WEDNESDAY SEPT.2,2015 11:00 AM.
PARCEL NUMBER: 12220-24-60040 and 12220-50-76000
SITE ADDRESS:LakeLand Drive,Alyn WA
PROJECT DESCRIPTION: New 11,528 sq.ft.church bldg.;fire suppression system,parking area and associated stormwater system
Property is zoned in the Allyn Urban Growth Area R3 high density multi-family residential zone. Property has existing church building and parking lot areas(37 standard,6 disabled,and 3 to 5 large vehicle
stalls). Proposed development adjacent to parcels to the north shall be affected by the RIP zone(residential platted)in regard to setbacks.
Uses Allowed subject to obtaining a Special Use Permit:
1. Churches
Setbacks: Yard setbacks refer to the setback of structures from the property line Where a property abuts another zone district with a more restrictive setback requirement the most restrictive setback shall
apply.
Front yard: 20 feet.
Side yard: 5 feet.
Rear yard: 10 feet.
Building Size. 10,000 sq.feet maximum inAllyn UGA;larger building of 11,500 sq.ft.size will require the public hearing review and approval of a Special Use Permit
Signs:follow standards of MCC Chapter 17.15 for size,location,and forms of signage.
Critical Areas:no slope,wetland and typed stream areas are present;Case Inlet shoreline is more than 1/4 mile to the east.
Parking for the new church shall follow the standard: 1 stall per 3 seats in the largest assembly area;applicant shall describe and portray at time of Special Use Permit and building applications. Road access
permit needed to evaluate the changes in parking entrance and new parking areas
Stormwater:For the proposed buildings and parking or use areas represented,the applicant must provide concise engineered review plans and submittal checklist following the2005 Stormwater Manual that
clearly states how the MCC 14.48 stormwater standards are met,with some review by Mason Co.Public Works stormwater coordinator[Loretta Swanson(360)427-9670 ext.769]. A current O&M plan will
be needed for the pond modification;and a source control plan(along with a pre-treatment schedule)will needed for the new building.
Page 2 of 2 CaseActivity..rpt
MASON COUNTY
,y DEPARTMENT OF COMMUNITY DEVELOPMENT
Mason County Bldg, III, 426 West Cedar Street
Shelton, WA 98584
1854 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269
MASON COUNTY PRE-SUBMISSION CONFERENCE NOTES
• BUILDING DEPARTMENT REPRESENTATIVE: Rich Balderston (360) 427-9670 x 285
E-Mail: rbalderston@co.mason.wa.us
• DATE: September 2, 2015
• PROJECT/ PROJECT TRACKING NUMBER: PAR2015-00030
• PROJECT REPRESENTATIVE (S): Steve Hanson
DESCRIPTION & SIZE OF PROJECT/OCCUPANCY CLASSIFICATION & USE: Primary occupancy
classification A-3
Complete building permit applications will include the following information that is applicable to the project::
Complete International Building Code chapters are available at the following website,
http://publicecodes.cyberrecis.com/icod/ibc/2012/
• SETBACKS TO PROPERTY LINES: Provide a site plan, drawn to scale. Clearly identify all structures,
including fences, fuel tanks and other similar items, with setback dimensions on site the plan.
• DISTANCES TO OTHER STRUCTURES: Site plan, drawn to scale shall clearly identify distances, where
required include fire-resistive details, including continuity, &tested assembly details.
• FIRE RESISTANCE FOR EXTERIOR WALLS: When applicable include fire-resistive details, including
continuity, &tested assembly details.
• IDENTIFY TYPE OF CONSTRUCTION & PROVIDE ALLOWABLE AREA CALCULATIONS WHERE
NEEDED. See Chapter 5, IBC. Type VB construction includes structures constructed with combustible
construction such as wood framed structures. Type II construction includes steel structures constructed
ENTIRELY by non-combustible construction. Plans provided show type VB construction
• FIRE-RESISTIVE RATED CONSTRUCTION &TYPE OF CONSTRUCTION :
Where required demonstrate compliance. Identify the location of the assembly, compliance to
continuity requirements and construction details:
EXTERIOR WALL(IBC704), FIRE WALL(IBC705), FIRE BARRIER(IBC706), SHAFT ENCLOSURES
(IBC 707), FIRE PARTITIONS(IBC 708), SMOKE BARRIERS(IBC 709), SMOKE PARTITIONS(IBC
710), HORIZONTAL ASSEMBLIES(IBC 711), PENETRATIONS(IBC 712), FIRE-RESISTANT JOINT
SYSTEMS(IBC 713), FIRE-RESISTANCE RATING OF STRUCTUURAL MEMBERS(IBC 714),
OPENING PROTECTION(IBC 715), DUCT&AIR TRANSFER OPENINGS(IBC 716), CONCEALED
SPACES(IBC 717), ETC,
• NUMBER OF EXITS REQUIRED/OCCUPANT LOAD:(IBC 1004): Table 1004 is used to determine
occupant load used to evaluate the structure for exiting purposes, plumbing fixture requirements, and other
code related concerns. Include design calculations, demonstrating how occupant loads were calculated,
on building plans. Table 1004.1.2 provided
• EXIT PLAN: Clearly identify the exit path and exit signage on construction plans. IBC Chapter 10
• ENGINEERING REQUIRED: Structures that do not comply with prescriptive specifications of the 2012
International Code (IBC) shall be designed in accordance with Chapter 16 of the IBC.
Referencing Washington State RCW 18.08.410- Structures 4000 sq. ft or more shall have all plan
pages reviewed and stamped by a Washington State licensed design professional. The review shall
include a code evaluation addressing life-safety, plumbing & mechanical evaluation, and structural
analysis. (ref. RCW 18.08.410) ALL PLAN PAGES SHALL BE STAMPED AND SIGNED BY THE
DESIGN PROFESSIONAL, including plumbing and mechanical pages.
• ACCESSIBILITY REQUIRED: YES, include compliance information including design calculations
demonstrating compliance to Chapter 11 and details demonstrating compliance to ANSI 117.1 in effect at
the time of submittal. Include information demonstrating compliance for restrooms, employee work areas,
parking spaces, accessibility to structure, drinking fountain, signage, etc. When required verify that
building plans contain compliance information.
• PLUMBING SYSTEMS (Chapter 29 Washington Amendment to IBC): Using IBC Chapter 10, determine
occupant load. The number of plumbing fixtures is determined based upon the occupant load. Plumbing
fixtures need not be provided for unoccupied buildings. Permitted building shall comply. On plans, include
design calculations for the following: water closets (M/F), Lavatories, Drinking Fountains, etc.
• Referencing IBC/WAC 2902.2 separate plumbing fixtures shall be required for each sex, except when the
calculated occupancy load is 15 or less, then unisex fixtures shall be allowed. To calculate the number of
fixtures and referencing Table 2902.1 the following fixtures shall be required:
Offices: 1 water closet per 25 for the first 50 and 1 per 50 for the remainder exceeding 50. 1
lavatory per 40 for the first 80.
Storage(S1&S2): 1 water closet per 100 and 1 lavatory per 100.
Plumbing fixture count can be for the entire facility, including all structures)for compliance purposes.
Provide design calculations demonstrating how the fixture count was determined on construction plans.
• NON-RESIDENTIAL ENERGY CODE: ALL enclosed spaces require Non-Residential Energy
Conservation Code (IECC/WSEC). Provide completed compliance forms (envelope & mechanical).
Forms are available at: http://www.neec.net/resources/resources.html
• LIGHTING: All non-residential structures shall comply with IECC/WSEC lighting requirements. Complete
compliance forms and provide a lighting plan that includes switching locations. WSEC forms and
information can be accessed at: http://www.neec.net/resources/resources.html.
In addition your local utility may have an incentive program, designed to help you lower energy
consumption. To discuss incentive opportunities contact the Energy Services Department at PUD3 by
calling (360)426-0777 or PUD1 at(360) 877-5249.
• Ventilation and Indoor Air Quality Code compliance: Provide calculations when required.
• COMMERCIAL KITCHEN: Show compliance to Chapter 5 of the International Mechanical Code when a
kitchen is included in the project. Type of cooking to be done must be clearly identified, type 1 hood
may be required
• GEOTECH REPORT REQUIRED? YES / NO (Refer to planning requirements)
• OIL SEPARATOR: REQUIRED when vehicle repair work is performed. Identify location and provide
construction details.
• PROVIDE A SPACE FOR STORAGE OF RECYCLED MATERIAL & SOLID WASTE (WAC51-50-009):
Identify the location.
• SPECIAL INSPECTION: Referencing IBC Chapter 17, Section 1704.1.1. Statement of special inspections
prepared by registered design professional in responsible charge. Complete a Special Inspection
authorization form. Special Inspection Authorization form provided
• INTERIOR FINISHES: Include information demonstrating compliance to Interior finishes required in IBC
Chapter 8.
• STORAGE SPACES: Identify material stored, anticipated quantities, height, and if hazardous, include
MSDS sheets for each product.
• STORAGE RACKS greater than 5'9" shall be permitted either with the proposed project or separate
building permit. Where required documents shall include design information demonstrating stability for
seismic conditions. Special inspection may be necessary, reference IBC Section 1707.6 and 1705.3 (4.5),
storage racks, provide compliance information.
• MECHANICAL EQUIPMENT: Identify the location and type of mechanical equipment located within, and
outside the structure. Address foundation and support systems for equipment. Where new equipment will
be placed on site provide UL listing information and/or construction details stamped by a Washington State
licensed design professional. Where applicable include duct information and duct support compliance
information.
• FIRE MARSHAL REQUIREMENTS: Carefully review Fire Marshal comments requirements including fire
protection requirements and identify compliance information on the proposed building plans. Show the
location of fire extinguishers and identify type.
• SPRINKLER SYSTEM: Verify that design calculations include additional load attributed to required fire
sprinkler system. Commercial fire flow worksheet provided. Occupant load 300 or more requires
sprinkler system. Fire areas in excess of amounts specified on fire flow worksheet requires
sprinkler system, provided definitions of fire areas, fire barriers, and fire walls
• SUSPENDED CEILING SYSTEMS: Provide details and specifications relating to suspended ceilings
where applicable. Details shall be designed and approved for seismic loading in accordance to IBC
Chapter 16. Where required designate special inspection plan.
• OTHER:
PERMITS REQUIRED FOR PROJECT
a BUILDING
z PLUMBING/ MECHANICAL
z GRADING PERMIT(When greater than 200 cubic yards)
❑ CHANGE OF USE
z FIRE SUPPRESSION, where required. See Fire Marshal comments
z SIGN
z FENCE (Greater than 7'0" above grade)
Ll
El
ADDITIONAL NOTES:
WHEN YOU ARE READY, SUBMIT FOUR (4 SITE PLANS, DRAWN TO SCALE ALONG WITH THREE (3)
COMPLETE SETS OF BUILDING PLANS INCLUDING THE FOLLOWING. (NOTE,ALL PLAN PAGES SHALL
BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHEN THE STRUCTURE
EXCEEDS 4000 SQ. FT.):
• CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section,
construction details, etc.
• MECHANICAL PLAN,
• PLUMBING PLAN AND
• NON-RESIDENTIAL ENERGY CODE/VENTILATION & INDOOR AIR QUALITY CODE INFORMATION.
• DEFERRED SUBMITTAL WILL NOT BE ACCEPTED.
• A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED.
VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA
RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF
THE 1997 UBC.
DESIGN CRITERIA:
SEISMIC ZONE: D2
WIND SPEED: 85 MPH basic 110 ultimate, Exp B (Unless proven otherwise)
GROUND SNOW LOAD: 25 psf
REFERENCE CODE EDITIONS: Effective July 1, 2013
2012 INTERNATIONAL BUILDING CODE(IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING
H106; SECTIONS 101 THROUGH 107, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND EXCLUDING
APPENDIX CHAPTERS A, B, D, F, G, I,J AND K AND;ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
50,AND THE 2012 INTERNATIONAL EXISTING BUILDING CODE.
2012 UNIFORM PLUMBING CODE(UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND
MECHANICAL OFFICIALS(IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC
51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15,AND 16, PART I.
2012 INTERNATIONAL MECHANICAL CODE(IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL,AND
THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC
51-52.
2012 INTERNATIONAL FIRE CODE, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING APPENDIX A, D,
AND K AND ADOPTING APPENDICES B,C,E,F, G AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-
54.
2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC), AS AMENDED BY WASHINGTON STATE BUILDING
CODE WAC 51-11
To view the Mason County Building and Construction Code and adopted amendments go to the Mason
County website at: www.co.mason.wa.us.