Loading...
HomeMy WebLinkAboutBLD2018-00294 SFR - BLD Application - 3/29/2018 AoN cover MASON COUNTY COMMUNITY SERVICES PERMIT ASSISTANCE CENTER: Permit No: l •BUILDING-PLANNING•PUBLIC HEALTH•FIRE MARSHAL _ 615 W.Alder Street,Shelton,WA 98584 y Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone Belfalr.(360)275-4467•Phone Elma:(360)482-5269 1854 BUILDING PERMIT APPLICATION ,y PROPERTY OWNER INFORMATION: CONTRACTOR INFOffX66 -'U NAME: e2 Ockc/%401 NAME: 0`'' Rf" MAIL5#2: oo DRESS: 0 0X- p FS- MAILING ADDRESS: CITY: STATE:� ZIP: �5�Z�{ CITY: STATE: ZIPwr PHONEo Z , 7 G PHONE: CELL: PHONE ( ;S z EMAIL : EMAIL: U A I-td C �a ,C o,— L&I REG# EXP. / / - PRIMARY CONTACT: OWNED& CONTRACTOR❑ OTHER❑ NAME EMAIL MAILING ADDRESS CITY S!!� PHONE CELL PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) l27-2 0 50� "2, 4 U ; ZONING � Z LEGAL DESCRIPTION(Abbreviated) G.av 3 j3 k S 3 FIRE D/�S�CT SITE ADDRESS 13 r'�^ tv e (I S T Y = CITY �//l'f.� DIRECTIONS TO SITE ADDRESS blk., 1'3 7y w e 3 i we S'f 0,­ 3�P6404?— •Tv O;" t11- IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO,0 IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW-4 ADDITION❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.) �Se5 r C((I,C -4 IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS HEATED STRUCTURE? YES(Whole BldgJ;r, YES(Part[sl of Bldg) ❑ NO ❑ DESCRIBE WORK I1/� SQUARE FOOTAGE: (propose+existing) I ST FLOOR 7 & sq.ft. 2ND FLOOR 9S(o sq.ft. 3RD FLOOR sq..ft. BASEMENT LS /0 sq.ft. DECK sq.ft. COVERED DECK, 3 Z sq.ft. STORAGE /7/nr sq.ft. OTHER sq. ft. GARAGE y20 sq.ft. Attacheda Detached❑ CARPORT _&// sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC ❑ SEWERS / NEW❑ EXISTING ❑ PLUMBING IN STRUCTURE? YES-64-' NO❑ If yes, attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES-Z NO[] EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS ?j TOTAL BEDROOMS OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that 1 am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null$void if work or authorized construction is not commenced within 180 days or If construction work Is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON COUNTY CODE 14.08.42) -2,/ ZZ Signature of OWNER(Must be signed by the OWNE Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT -P PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH MASON COUNTY RECEIVED COMMUNITY SERVICES �_/ Building,Planning,Environmental Health,Community Health MAR 2 9 2018 Physical and Mailing Address: 615 W Alder St., Bldg 8, Shelton, WA 98584 Shelton Phone: (360)427-9670 ext 352 •:• Fax (360)427-7798 15 W.Alder Street PLUMBING & MECHANICAL PERMIT APPLICATION Permit#:,bId?D18-66Zay OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: r c4,..'e Per V l? NAME: O kf✓ A MAILING ADDRESS: o oz o iS MAILING ADDRESS: CITY: -// STATE: ✓A ZIP: 5ZY CITY: STATE: 9 IMP 15t PHONE V 5 2 b PHONE: CELL: 2nd PHON� 01 ''Z— EMAIL EMAIL: L fi L E r COS L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER (12 Digit Number): / 22'Z 0 547 S?i 7 Zoning: !2 Z LEGAL DESCRIPTION (Abbreviated): Go T 3 3 k 5 3 • & SITE ADDRESS: X,C 3 /v-c k(-vc([ S-r CITY: DIRECTIONS TO SITE ADDRESS: /_1(.wy 3 -to r40 4. 0' W,0 5r p>n S e ( J r4' -r'- /VI)rig 0 13 I st c L, e-(( r v /oT 0, I?"4& T- TYPE OF JOB/WORK: NEW >e, ADD ALT REPAIR OTHER USE OF BUILDING S t ik - ' �� 2?5(CG—CQ PLUMBING FIXTURES MECHANICAL UNITS [] Electric in-wall heaters(no fee) Type of Fixture No. of Fixtures Fuel Type Fees Type of Unit No. of Units Fuel Type Fees Toilet(s) :32 — Furnace [E/G/LPG] Bathroom Sink(s) Heat Pump [E/G/LPG] Bath Tub(s) Z 0 Ductless H.P. % (F�G/LPG] i Shower(s) Spot Vent Fan Water Heater(s) [E/G/LPG] Propane Tank gal.] Clothes Washer(s) / [E/G/LPG] Gas Outlet(s) Kitchen Sink(s) 4 Heat Stove [E/G/LPG/W] Dishwasher(s) Kitchen Exhaust Hood Hose bib(s) Dryer Vent Other Solar Panel Other Other Plumbing Subtotal Mechanical Subtotal Plumbing Base Fee Mechanical Base Fee Final Inspection Fee Final Inspection Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INAqIVITY OF THI. RMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Si ture of A plican M�nerl X ,J v. wners Representative/Contractor rint Name one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS O Building O Fire Marshal O Permit Tech (OTC permit only) V!w us on-line: http:,/www.co.i-nason.wauS/comrnunitv_dev/ Rev:3/08/2017 Permit number BLD Mechanical Permit Checklist • Name of owner: Name of Installer: • Fuel Type? LPG Nat Gas Electric Other • If propane, what is the proposed size of tank(s)? • What type of mechanical unit will be installed? (i.e.freestanding stove,forced air furnace, etc.) • If the unit is a wood stove,provide: Make Model Year Label Number • What is the use of the structure? (Circle one) Residential Commercial (A permit application for a commercial mechanical permit will be issued upon satisfactory review by staff.' Include a floor plan showing the location of unit(s)and layout of duct work with the permit application.) • Type of structure: (Circle one) Site Built Home Manufactured Home Other • What room will the mechanical unit be located? • Will the unit be located in a basement?(circle one) Yes No • How will combustion air be supplied to the mechanical unit? (Describe, i.e. direct vent, air inlets, etc.) • How will the mechanical unit be exhausted to the outside? Applies to appliances using gas, oil or wood fuel. (Indicate B-vent, direct vent,L-vent,etc.) • What year was the structure constructed? Was this structure part of a PUD upgrade? • What type of controls will be installed? (i.e. thermostat, etc.) • Will the proposed mechanical unit be a heat source?(circle one) Yes No • Additional information: Signature of Applicant Date T--pical mechanical fees: Forced air furnace $ 18.30 Heat pump 18.20 Propane tank 73..00 Gas Outlets 6.20 additional outlets over 1-5 ($1.20 each after 5) Mechanical base fee 28.50 or $ 9.00 if base fee was paid on an active building or mechanical permit Freestanding unit, fireplace,pellet stove or wood stove $73.00 Final Inspection fee 73.00 Simple Heating System Size: Washington State This_heating,�vstem sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information Drew Davies Drew Davies 20 E Blackwell St Po Box 1095,Allyn Wa 98524 Allyn,Wa 98524 360.432.8576 Heating System Type: (D�ll other Systems *teat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions .:. .,. -� ... Design Temperature Difference(AT) Bremerton OT=Indoor(70 degrees)-Outdoor Design Temp AI�IRIt t Area of Building Conditioned Floor Area � � Instructions Conditioned Floor Area(scl ft) 2,252 AR 9 L 4V Average Ceiling Height Conditioned Volume e'y►� `J Instructions Average Ceiling Height(ft) 8.0 18,016 1 Glazing and Doors U-Factor X Area = UAa/'S Instructions +`19 u-o.za----- ------- . " 0.280 214 59.92 61 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area UA �+ Instructions "' — -- `—` -- --` � 0.026 956 24.86 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project 1 ' Above Grade Walls(see Flours 1) U-Factor X Area UA Instructions _"21 Intermediate �^' - 0.056 2.008 112.45 � R- � Floors U-Factor X Area UA Instructions Rd8 - ----- ----- -- 0.025 196 4.90 � Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions R 211nterioterio r 0.042 576 24.19 "> � ` 11 Slab Below Grade(sea Figure l) F-Factor X Length UA Instructions 0.303 540 163.62 R 10 Fully insulated � ' Slab on Grade(see Figure l) F-Factor X Leh UA Instructions 0 No slab on Grade in this project. A Location of Ducts Instructions Duct Leakage Coefficient ^No D� ucts "` 1.00 Sum of UA 389.94 Envelope Heat Load 15,987 Btu/Hour Figure 1. Sumof UAXAT Air Leakage Heat Load 7,977 Btu/Hour vaumex o.sxerx.ole Above Grade Building Design Heat Load 23,965 Btu I Hour Air Leakage Envelope Heat Loss Building and Duct Heat Load 23,965 Btu/Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 Ducts in conditioned space:Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 29,956 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) (R-2 occupancy is Residential occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature, including: Apartment houses, Boarding houses (non-transient) with more than 16 occupants, Congregate living facilities (non-transient) with more than 16 occupants, Convents, Dormitories, Fraternities and sororities, Hotels (non-transient), Live/work units, Monasteries, Motels (non-transient), Vacation timeshare properties.) c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area. Requires 4.5 credits. d) Additions less than 500 sq feet. Requires .5 credits 4 Must provide a completed heating/cooling system size worksheet to verify compliance to IECC R403.7. The calculator/worksheet is available on the WSU-Energy Program website at: http://www.energy.wsu.edu/Documents/Heat Sizing code%20specs final 2015.xls. Staff may be able to assist with preparation of the worksheet. 5 Must meet the prescriptive option for all fenestration products. Products shall comply with the required U- factor listed in Table R402.1.3. Windows, doors, and glazed doors shall have a tested U-factor or .30 or less. When using the small dwelling option for energy credits (a) or Performance Alternative approach you must provide a fenestration schedule that identifies the square feet and U-factor of each item. Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed- doors that include products with glass and non-glass glazing materials. 6 Identify on the construction drawings the location and fuel type of the heating system, water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of proposed insulation for walls, floors, ceilings, and concrete slab floors on the building plans. 7 Not less than 75% of all permanently installed lamps in lighting fixtures shall be high efficacy lamps. High efficacy lamps are defined in IECC Chapter 2 and are considered compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps, or lamps with a minimum efficacy 60 lumens per watt for lamps over 40 watts, 50 lumens per watt for lamps over 15 watts to 40 watts, and 40 lumens per watt for lamps 15 watts or less. If you need assistance please contact Mason County Community Development at (360) 427-9670 ext. 352 or WSEC compliance information and code text is also available on the WSU-Energy Program website at: http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode.aspx Prescriptive Requirements °,' for Mason County Climate Zone 4-C, Table R402.1.1 Fenestration Glazing U-factor Area% Vaulted Wall Wall Slab d on Option of Floor Vertical Skybight Ceiling Ceiling Grade int below grade Floor Grade (Inciudes doors, windows,etc. R-10,2 ft R-21 10/15/21 int+ R-30 Heated slabs 4C Unlimited 30 .50 R-49 R-38 int ICI TB require R10 full slab. Log & solid timber wall with a min. avg. thickness of 3.5" are exempt from the above grade wall insulation requirements. All footnotes are available on WSU-Energy Program Website @ http://www.energy.wsu.edu/BuildingEfficiencv/EnergyCode.aspx 2 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/Ventilation Code Compliance Application ' Submit with heating/cooling system size worksheet (see instructions #4) Ow Parcel#: _ Type of project: f w owe f S 1 21-a-0 5,0 5-� vr/ � ivt�,.� t� ice. f'��vt,%`l S< Total Sq. Ft. 1 s Floor : 2" floor: Heated Basement: of heated area:: Z'Z-5-2— -7 54 9 S 6 S y 0 Heating System Type: ,A�_Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace)KDuctless Heat Pump O Boiler, specify fuel type: O Other: Specify: 6K Prescriptive Option Table R402.1.1 (see table on previous page) Compliance Method ❑ Component Performance, R402.1.3 — Calculation worksheets required Must Check one:: ❑ Other (Specify): Check one JZ Whole House Ventilation system ❑ Whole House Ventilation using exhaust fans &window or wall Integrated with a Forced Air El Other, describe: Ventilatio fresh air vents(M1507.3.4). If using System (M1507.3.5) n System window vents be sure to order windows with vents. Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/iecc wsec.pdf Additional a) Description: Small dwelling units: less than 1,500 sq. feet of heated or cooled floor area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc). Energy *Including additions to existing building that are greater than 500 sq. ft. of heated floor Efficiency Requirem but less than 1,500 sq ft of floor area. Requires 1.5 credits ents b) Medium dwelling units that are not included in (a) above {small dwelling), OR (c) below Energy {large dwelling} Requires 3.5 credits credits EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5- required: credits. See page two for description. c) Large dwelling unit is a dwelling unit that exceeds 5,000 sq. ft. of heated or cooled floor area. Requires 4.5 credits d) Additions less than 500 sq feet. Requires .5 credits (Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials.) Describe Energy Credit Option(s): A6. (9eT71a Using Option (r(.z...a. A,� /e• ���.� -�. c��-�.�� P:r how r- /7,, ��/erS F{�.uTp�� number(s): IL.. w� Ter �1��-:• `"a 3 FENESTRATION SCHEDULE USE FOR ENERGY CREDIT, a) SMALL DWELLING OPTION & COMPONENT PERFORMANCE COMPLIANCE ' List all windows, doors, skylights. (If needed, attach an additional sheet) 'Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non- lass glazing materials. Manufacturer Location U-Factor Size Quantity Total (rough opening) Square Feet G() c L/o tr r2 ,Z,c 60;,( G � `/u 0 Total Fenestration: windows, skylights and door area Z (1 , 5 u Energy Credits 4 (2015 WSEC - Table 406.2) OPTION DESCRIPTION CREDIT(S) i EFFICIENT BUILDING ENVELOPE 1 a: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 5%. lb EFFICIENT BUILDING ENVELOPE lb: 1.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.25 Wall R-21 plus R-4 Floor R-38 Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 15010. 1 c EFFICIENT BUILDING ENVELOPE I c: 2.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.22 Ceiling and single-rafter or joist-vaulted R49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 Basement wall R-21 int plus R-12 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 30%. 1 da EFFICIENT BUILDING ENVELOPE I d: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U=0.24 AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a high efficiency fan(maximum 0.35 watts/cfm),not interlocked with the furnace fan.Ventilation systems using a furnace including an ECM motor are allowed,provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the qualifying ventilation system. 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.70. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system 5 OPTION DESCRIPTION CREDIT(S) c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: 1.5 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.85. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: 1.0 Gas,propane or oil-fired furnace with minimum AFUE of 94%,or Gas,propane or oiled-fired boiler with minimum AFUE of 92% To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0 Air-source heat pump with minimum HSPF of 9.0 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3Cb HIGH EFFICIENCY HVAC EQUIPMENT 3c: 1.5 Closed-loop ground source heat pump;with a minimum COP of 3.3 or Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet and minimum COP of 3.6 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3d HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0 Ductless Split System Heat Pumps,Zonal Control:In homes where the primary space heating system is zonal electric heating,a ductless heat pump system shall be installed and provide heating to the largest zone of the housing unit. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equip ment efficiency. 4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: 1.0 All heating and cooling system components installed inside the conditioned space. This includes all equipment and distribution system components such as forced air ducts,hydronic piping,hydronic floor heating loop,convectors and radiators.All combustion equipment shall be direct vent or sealed combustion. For forced air ducts:A maximum of 10 linear feet of return ducts and 5 linear feet of supply ducts may be located outside the conditioned space.All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic.If flex ducts are used,they cannot contain splices.Flex duct connections must be made with nylon straps and installed using a plastic strapping tensioning tool. Ducts located outside the conditioned space must be insulated to a minimum of R-8. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat and ductless heat pumps are not permitted under this option. Direct combustion heating equipment with AFUE less than 80%is not permitted under this option. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. 6 OPTION DESCRIPTION CREDIT(S) EFFICIENT WATER HEATING 5a: 0-5 'D All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads,kitchen sink faucets,and other lavatory faucets. 5b EFFICIENT WATER HEATING 5b: 1.0 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.74 or Water heater heated by ground source heat pump meeting the requirements of Option 3c. or For R-2 occupancy,a central heat pump water heater with an EF greater than 2.0 that would supply DHW to all the units through a central water loop insulated with R-8 minimum pipe insulation. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. 5 EFFICIENT WATER HEATING 5c: 1.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems or Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEAs Northern Climate Specifications for Heat Pump Water Heaters To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and,for solar water heating systems,the calculation of the minimum energy savings. 0.5 5d EFFICIENT WATER HEATING 5d: A drain water heat recovery unit(s)shall be installed,which captures waste water heat from all the showers,and has a minimum efficiency of 40%if installed for equal flow or a minimum efficiency of 52%if installed for unequal flow.Such units shall be rated in accordance CSA B55.1 and be so labeled. To qualify to claim this credit,the building permit drawings shall include a plumbing diagram that specified the drain water beat recovery units and the plumbing layout needed to install it and labels or other documentation shall be provided that demonstrates that the unit complies with the standard. 6 RENEWABLE ELECTRIC ENERGY: 0.5 For each 1200 kWh of electrical generation per each housing unit provided annually by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits. Generation shall be calculated as follows: For solar electric systems,the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PV WATTs. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors:The wind turbine power curve;average annual wind speed at the site;frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, Provide documentation of solar and wind access,and include a calculation of the minimum annual energy power production. a.Projects using this option may not use Option la,lb or lc. b.Projects may only include credit from one space heating option,3a,3b,3c or 3d.When a housing unit has two pieces of equipment(i.e.,two furnaces)both must meet the standard to receive the credit. G Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and showerheads)shall comply with the following requirements: 1.Residential bathroom lavatory sink faucets:Maximum flow rate-3.8 Umin(1.0 gal/miu)when tested in accordance with ASME A112.18.1/CSA B125.1. 2.Residential kitchen faucets:Maximum now rate-6.6 Umin(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1. 3.Residential showerheads:Maximum now rate-6.6 Umin(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1 7 Name DQ.�7�25 Parcel# fZZZC1--'Z-53003 BLD# Mason County Department of Community Development ® Small Parcel Stormwater Management Application/Worksheet (RU;[2nit, Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings 2t X 2Z _ Z? X 75t Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways Z J X % G = 3 z o X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X `( _ '3 L X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) y If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described p f rev' and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: ' If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge the information provided on page 2 of 2. Page I of 2 erst��°t Name- -- Parcel# BLIN Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: 360-427-9670 ext 450 100 W.Public Works Dr Shelton.WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: 360-427-9670 ext 400 415 N. 6th St— Bldg#8 lower level Shelton.WA 98684 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 I r/Z q� `4 (A` 6 l V I SITE COPY ' THESE PLANS MUST BE ON THE JOB SITE FOR INSPECTION Z�� -� Q� ��le`-✓ IJG,n•m� BUILr .. (Z22.1)-50 5 3 Gh 3 © CHANGES kwt-(c5F SUBMIT TO PERFORMING WORK K � Sz`1 PRIOR RECEIVED MAR 2 9 2010 t�---N s, c ya4td • 5 F 4- 9�p �18-Q029 �D y � o -�� - a 615 W.Alder Sty Oma Z = Cen Z c GI W � rn 0 �l y mO Z � Z C� CD o W 0 2ZJ • � m l�cr��j'- 1 O D ��`j"� WA- 7 v 9J2-I1 - Z L D cn m z 22Z� -sv it, 3( k u.,s- s r /A (I, w A ?9,5 ECEIVED O&iq / R-2. 3 0fa--ee r►1 Fite-n t� 20 ��- MAR 2 9 2010 t�---, U S;da. cued • 5 Ft ®�c � Zoo-coy Y � �D '� y 9.e&,-Yale&( Zo r+ 615 W.Alder SbIW MASON COUNTY DEPARTMENT OF COMMUNITY SERVICES BUILDING DIVISION �C,��►s;,� ., SHELTON (360)427-9670 BELFAIR (360) 275-4467 Elma (360) 482-5269 MAR FAx: (360) 427-7798 WEB SITE: www.co.mason.wa.us #18 a3 615 W ALDER STREET, SHELTON 98584 A/ 2015 International Energy Conservation Code, as amended by WAC 51-11 (IECC) <: Effective July 1, 2016. Ventilation code provisions are located in the 2015 International Residential)5e;41)L, 0j Mechanical Code IMC & 2015 International Building Code 1VG 2015 International Me ( ), A complete energy code application form will include information that clearly identifies compliance methods for heat sizing, thermal envelope, and whole-house ventilation. This form includes compliance instructions and information needed. Energy code compliance information, forms, worksheets, and educational information is also available on the Washington State University Extension Energy Program (WSU-EP) website. To access the website go to http://www.energy.wsu.edu/BuildingEfficiencV/EnerqvCode.aspx . The website includes a heat system sizing calculator. Submit a completed heat sizing calculator worksheet when the building permit is submitted. In addition to the heat sizing calculator the website has helpful compliance information and worksheets for prescriptive and component performance options along with a glazing schedule. INSTRUCTIONS: Complete the Mason County Energy Code application and submit with a heat sizing calculator available on the WSU-EP website, see item #4 below: 1 Identify the compliance method. The most common and simplest approach is the prescriptive method for energy code compliance. See prescriptive table R402.1.1 located in the instructions. The Performance Alternative approach referenced in IECC Section R405 may also be used for energy code compliance. For more information contact Mason County Building Department staff at (360) 427-9670 ext. 352 or WSU Energy Program at (360) 956-2042. Compliance must be shown on your construction drawing in addition to this application. 2 Identify the whole-house ventilation compliance method. A ventilation system must be installed in accordance with The International Residential Code, Section M1507. The most common ventilation methods include a whole-house ventilation system using exhaust fans (M1507.3.4) and a whole-house ventilation system integrated with a forced-air system (Ml507.3.5). Other ventilation systems include whole-house ventilation system using a supply fan (Ml507.3.6) and whole-house ventilation system using a heat-recovery ventilation system (M1507.3.7). Ventilation openings are required in each habitable room in accordance with M1507.3.4.4. If you need additional information we recommend that you discuss with your heating and ventilation system professional. In addition Mason County staff will be happy to discuss the options if you are not sure which compliance option will work for you. 3 Identify the Additional Energy Efficiency Requirements listed in Table R406.2. The drawings included with the building permit application must show and identify which options have been selected and the point value of each option. Each one and two-family dwelling unit and townhouses are required to achieve the following minimum number of credits: a) Small dwelling units: less than 1500 sq. feet of heated or cooled floor area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc). Additions to existing building that are greater than 500 sq. ft. of heated floor but less than 1500 sq ft of area. Requires 1.5 credits b) Medium dwelling units that are not included in (a) above {small dwelling), OR (c) below{large dwelling) Requires 3.5 credits EXCEPTION: Dwelling units serving R-2 occupancies shall require. Requires 2.5 credits. 1 VM6N DATA ��--' bE�RAL NOTES* * CODE 2015- RG,UPC, G T'LANS Dr515NED AGG'�PRDiNS TO THE 2015 IRO 2. CONTRACTOR TO GHEGK AND'JEREfK ALL ` WlNP 5FEED {{Q MPH DION RI Nq BEFORE CTOR T GONFFIIRM THE SIZES,SPACING,AND SPECIES OF LUMBER 5. CONTRACTOR Jr,ZONE P-2 OF ALL STRUGNRAL AND FRAMING MEMBERS. I t ! SNOW LOAD 30 p5F WINDO►IS: 1 , 2'O"xBYi" SOIL 3R6 500 195F I.THE CLEAR OPENING, O'iN11"00w5 IN SLEEPING ROOMS SHALL NOT EXG-1rD ! QQQ 44"FROM FINISHED FLOOR. FRQ5T M-FTH 12` 2,ALL WINDOWS TO BE 17JAL GLAZED ! S.ALL GLASS €N A DOOR,N�XT TO A DOOR W/1 12",OR I4'-0" �'-°" W!I IS° OF FLOOR OR?VI 60'OF TUWSITY�R VERTICALLY OR HORIZONTALLY ^ i TO SE SAFETY BLAZED,OR ANY OTHER HAZARDOUS AREA PER IRO, bob!& 6L5DR VENTILATION: �. I.VENT D.W. A 51NK -NV i 2.VENT DRYL`R OUTSIDE iRG M1501.1 3.VI<N7 HAT.TO PxPAN5i0N TANK Lk 4) 4.VENT ALL FAN5 OUTSIDE NV3'MIN.TO BLD6.OPN6 OR T 5. KITCHEN RANGE VENT TO ESE MIN. 100 GFM b. PROVIDE".OLE HOUge FAN Y`V PROPER MAKE AP AIR ?. }PROVIDE PROPER ROOF AND GRAAL SPACE VENTILATION PER IRO i) I 7 I MEC.HANIGAL 4 ELEGTREGALi —KV Sf# { O S� I.LAYOUTS INGLI VED IN THIS PLAN SHALL BE INTERPRETED A5 5UEsbE5TED 1 E st I CHANICAL AND ELEGTRIG P° AL LAYOUTS. FOR MOSE 5PEGIFIGA OR ME 5 I i 1 1 it1 GO>�-WLT A PROF2E55tONAL MECHANICAL a ELECITRIGAL CONTRACTOR. ii'G SMOKE a ,ARSON MONOXIDE DETE5C. -HALL RECEIVE PRIMARY I DiNI Y I.iYIN6 FROM euiLD!N(5 wIRIN5 YV BATTERY BACK-UP a SHALL hT �'8"Xli'O' �P 4'4"xil�• 0,. BE fERCONNEGTED TO ESE AU 01J AUDIBLE THROU6T BLD6. i 5,VERT.DIST BETWEEN GOOK TOP OF RANGE AND HOOD SHALL M NO L.ESS„ 4.HWT d FURN IN GARAGENSHALL EIE WARDED FROM VEHICLE COLLISION �-- 3'-2" III a LOCATED 18"ABOVE FLR IF IT GENERATES 3f�ARK OR FLAME _ i y 5,HAT SHALL EE ANCHORED OR STRAPPED FOR EARTf OUA J<E 4 L CI — _ { PLACED CRt R-10 PAD IF LOCATED IN UNHEATED 5PhGR GONG.PLR 1 6.TLP HWT TO OUTSIDE 276 I I 1 1 ?_PROVIDE OUTSIDE C0MS)STION AIR FOR FURN PER !RG CH, I? n�e�w�s IA R & s :. {— R 1! M+SGELLANE0,15: a da Ohs ; 1 I. PRGVIt7E qOk FYLT BETWEEN POSTS a GONG. ad f ]] ® 2.poop BETWEEN HOUSE AND 6ARAC7E TO BE SELF 6L05iN6 AND: as 1A(Hov 1 3'-6 A) 1-5/a"50LIC WOOD 0, a 2 S OI co,sue. r-4 ta'-b" 7@ G) 2O/MIN SOLID RATED Y GOViB STmL w a 14 S.ALL S7A;RwAY5 TO HAVE MIN.&'_6" HEADROOM CLEARANCE 4 i a STARS RAMPS,AND LANDINGS A30Vr 90"REOIiIRE 36"RAILINb i GONSTRUGTED 4. ALL EXT'cRIOR DECKS AND POR.HES TO 8E r Q f YViTH PRE5SURE TREATED WOOF Q � � 1 5.22"�'JO" ATTIC,ACCESS R OUIREV iP ATTIC VERT HEIGHT 15 90" OR MORE I b.ALL DEFORMED ReINPORGINb STEEL SHALL SE C1i Cn I J 1 Wcfm Zfb 10 tP�2 A5TM A 6 5&RAD=60 Py a 601000 PSf }— 1 ?,PROVIDE HOSE DIEM A5 PER OWNER v S. INSULATE ALL P'TRAPS EXPOSED IN CRAWLSPACE. tYi'P FRµ Io O t a.PLANS BY STRUCTURAL EX61MEER TAKE PREGEOENGE OVER THESE PA515, O ci CV 1 X 10.SI'M nSiNEERINS,FOR SEAMS,ETC. N§�• of � is 1 4'x4"P35T i m 4 Y►g.TYFE X ; ` �' OI��ERMAM 1 C,"T v- FIRE%ILLS a CL6 i ----.._. -° I N I SQUARE FOOTAGE a-- TOTALS �4�8f��+,°4-3!r t�;7R�ATGUJ6'N'.c°),5 il�GlOr' �`BQ9 12 5L3 FIRST FLOOR 756 S. . I SECOND FLOOR 956 S.F. LU 5c6 S.F�-- O--- ----- BASEMENT LOZF FLOOR ABOVE TOTAL 2252 SF. GAME 420 I W _ — 5T 2672 S.FTOTAL RECEIVED DECKS ;28 .F- N CL �a FzOaS I ` s.F_ SAME I i DOOR MAR 2 9 2018 u I t pR�WiN6 iN1�X � �� Q �15 W Alder Street ; I 5HEET NO. DESGRiPTfoN C ILION, R PLAN,NOTES,DE516N DATA 2OOR PLAN,WALL.SECTION J 1i N,DETAILS,DECK DETAIL W - Iui ��1?5T �J..ac PLAN 4 EXTEtzIOR ELEVATIONS VV,9ROg5EGT1ON � ra' = I'-V �56 eO, I. Ems... /ENT HA bn6.m55E5®24"O.G. Ny MIN i" fFZ 5rrl R-4q VENT iN5UL. Gompo51TION ROOFING 1 -LIP h" 150 BIHLT)IN6 PAP132 ;n VENT BLOGKiNS EAVE DETAIL 5050 SL 6040 SL WW:95 ;�',I'-a° 1 r ' - R-49 INSULATION GONTINUOUB CUTTER f F 1^V INStA. 'D 14'I'xll'Q" 6 � ' TYVEiC 4 VAULT elAB 00, Q I E I R-21INSULATION LOCATE TH5 POLL n ------ m .Mix to RM b-a' � •up"T46 gs ll i T..N JO18TS.0 W Q.G. $ Ik.I I r 0 I � I Ii _ k of r U1 1"6iVB. { aft w m 214 I AT ate spawm v+La OTMCAW '� ' a a Q I; i ry -_5�o Bp i(l " YiFiF TYVEK lot I SP. O N -R-50INSULATION WO'xi2^° Q�g,� IOE'TfONAL 2'x6"STUDS 0 16.O.G. f ` 3t �RD •at'oA.— a Q I1 "UDL X T46 ( y STS.0 16"O.G. TJI J01 ' ---- 2k6`P.T.SILL YV (� mpg 5L '63NB. ' W 3x5x 'KA&M O.C. 3 i aB i > Z < 8" <^ (. �I k I R-2i MoUL.ATION i GL i M4 BARS 0 lb"O.G.MORIZ O i t14 BARS 0 4@ O.G.VERT(ALT HOOK) �` � Z I U 2`96"ST'JOS 0 16"O.G, 1 5EWND FLOOR PLAN 956%.FT. _ — 4"GONGRETE rai AB SECTION 6 MIL Yl4"E'EtM DRAlN " r-a a 4' 1&RAVEL -i°SJ;Iu � w' L (4)>w4 8AR5!,ONTIN0005 i ~ � ,10-R'` it ii,ME PLIRIFM RAM Clow FT& IS El --hPROVIDE OW IA. FO"ATION VMS HIP!, ' THIS C0NPITIOX IS Lu HoLooms SAMOMMOMATION ^ ����� ��T�|� 3 ur~n. �oe�pr ncpo«no��nSn^pw1MouI�x�uo�2mN^w��y# _ R06£VENT f'YP) I � HOOP HAND RAiL 71g° G4e4'R!X F i IxiO SKIR It 15 3ALUSTM P N 2x12 TREADS W j I, 1/2"PK RiSC-R5 5/4x8 FACIA i (5)2xi2 STRINSER5 i 2x4 NAILS '2) 2x4 PLATES- I _ 2x4 STUD i^iA:.t--� •2x4 STUD A'.LL NARD'P_ANK 51DIN6 /2'6V1i3 5/8"4W8 1/2'45 dho I O IIIII i 5i4x4 CORNER!ems $Tl-=P °SC:CTION +} 5l4x8 BAR6E s3RD + � 5(4x4 RAKE. } + i I ®ZL1 I 4x4 4'O5T;OPTL) I i ` , ❑ II —� aIL'L ViOOD tiANC>RAIL 6iUED E NAILED �� 1 — BAW9TER5 5"OG.(OPT-) I l I € �j 'j 1 1 `--4x4 P05T i0!'T ) } JI i. 1 4} L� Da 4 j 1 FLOOR JOISTS 3 RIM J0157 LLJI LA Hild sfol _ FRONT ELEVATION ', /s" = -0° cant I I I SASE;BAR;;' ties g V + /2' 5TU �� � <xl2 T7$EADS ,� �x4 STUDS 6'O.G. pp;� DRtP ill"PNt.RI5c'"R5 , 2x4 PLATE asw y , arse 2x , SASE BOARD 2xi2 STRIN6EFt5 4 TOE f ` STAIR SECTION } O cif c-A I I RAKE UR1P ZD> c .2 EAyE DRIP EII�aE 225' � I - E U V I 1 Im > 1 I c I! (a �- 0 I I RIGHT ELEVATION REAR ELEVATION LEFT ELEVATION �, ,ro• r Z_e. i � I I ,r AL pf f' a. a �_.. i t I i i u -rl Tr 'f 'I SNEET uswcwua.a... MEA VAVI E5 a� OGT 201� i�� TOM 5Tr4� rue w�.erria�°oMrgc 2 STORY '°"'°""°m o"°°'OKV s111LiaiN6 D :315N INC. eia�lean e�ue�rtew.t�c i IRwc uux�id°o rM 296 eII1 A,Pbtr oBarlR w aIlM6 . XD'a7B-m CROSSECTION, FRAMING �_ 20 i�-38 ,�°;" ;�s„� �- 7 F-,r,<- I 1 A