Loading...
HomeMy WebLinkAboutBLD2018-01014 Reroof - BLD Permit / Conditions - 9/18/2018 Inspection Line (360)427-7262 C:Orj MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County 615 W Alder St Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2018-01014 OWNER: ROBERT SCHMID RECEIVED: 9/18/2018 CONTRACTOR: COGENT CONSTRUCTION 360-427-3162 LICENSE: COGENC1931 R6 EXP: 12/26/2018 ISSUED: 9/18/2018 SITE ADDRE LAKELAND DR ALLYN PARCEL NUMBE EXPIRES: 3/18/2019 LEGAL DESCRIPTION: LAKELAND VILLAGE 1 TR 6 PROJECT DESCRIPTION: DIRECTIONS TO SITE: REROOF ON SFR, 4/12 PITCH, COMP TO COMP, USING EXISTING HWY 3 TO ALLYN, L INTO LAKE LAND, FOLLOW TO SITE. SHEATHING AND INSULATION General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: RR Fire Dist.: 5 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Rear: Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Re-Roof Fee NMN 9/18/2018 $ 117.50 S120180000000i Building State Fee NMN 9/18/2018 $6.50 S1201800000001 Total $124.00 BLD2018-01014 Please refer to the following pages for conditions of this permit. Page 1 of 3 �► . CASE NOTES FOR BLD2018-01014 CONDITIONS FOR BLD2018-01014 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800 f The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner/Age t is onsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X r- 3) Single rafter joist roof replarjent shall be insulated to a minimum of R-38 allowing for a minimum of one-inch continuous vented airspace above the level of insulation. X 4) Existing roof deck shall be insulated to a minimum of R-38 if: The roof is un-insulated or existing insulation is removed to the level of the sheathing, OR All insulation in te, ceiling was previously installed exterior to the sheathing or non-existent. X 5) WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X 6) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be�ovid d at eaves and gables of shingle roofs. (I RC 2012 R905.2.8.5) X 7) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X (/'�/J� BLD2018-01014 Please refer to the following pages for conditions of this permit. Page 2 of 3 8)4%` The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). • It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obta' ed written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X 9) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall belmad for to requesting additional inspections. X (7 10) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordin�c d building regulations. X 11) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not excee ing 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented act! n om being taken. No more than one extension may be granted. X 12) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLYAFFECTANYADJACENT PROPERTIES NOR INCRE SE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROADWAY. X OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construct, work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT PLICATION 8 DAYS WILL INVALIDATE THE APPLICATION. ture Q Date L(-- ' `( ���✓ OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) BLD2018-01014 Please refer to the following pages for conditions of this permit. Page 3 of 3 co r— C/) CONCRETE MECHANICAL MANUFACTURED HOME 0 C� Date By T Footings/Setbacks Ribbons Gas Piping C? Interior Date By Interior-Date By Date By C? Exterior Date By Exterior-Date By set-up INSULATION 0 Point Load I Isolated Footings Date By co Date By EG I SLAB INSULATION FIRE DEPARTMENT M Data By X Foundation Walls Floors oate, By Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING Vault Data By Date By OTHER Groundwork Attic Date By Date By Type-- Date By D.W.1v DRYWALL Type- Date By lot Brace Wall DateBy CD Date By 0) FINAL INSPECTION 0 (n Water Line Fire Separation CD Date By Date By Date By co Pass or Request inspect. 6 Type of Insp. Fall Date Date Done By Comments Q CD (D 0 0 0 (n fD CD 0 COGENT CONSTRUCTION INC MMUMCIAL AWn)�?�Q[f�]R B MAi.RDDE Date Estimate# PO BOX 675 Union WA 98592 7/11/2018 4763 Lic#COGENC193'IR6 Phone:360.427.3162 Fax:360.427.4377 Email:lnfo@CogentConstructioninc.com Web:www.CogentConstructioninc.com 11 0 vi Name/Address er'm' Robe_ (Schmid) 681 E lakeland Dr Allvn wa 98524 P.O.No. Project Description Total r Removal of all composition on entire house and re roof with Certainteed landmark Pro c nposition with scotchgard over synthetic underlay ment.Hand nail all shingles.Remove and dispose of all debris. This estimate includes all ventilation,pipe boots,flashing and/or any other roof related components. Replacement of any rotten sheeting will be an additional charge at$1.75 per square foot Up to 6 sheets of I i2"CDX plywood is included at no additional charge. This estimate does not include replacement of existing skylights,but does include all new flashing. A Any composition estimate over$15,000.00,as well as all metal estimates,will require 1/2 down payment upon material order,with balance due upon completion. Cogent Construction Inc.requires signature and date on Estimate for acceptance of contract.Purchaser has up to 24 hours for recision of entire contract less deposit.Recision of contract after 24 hours will hold purchaser liable for 33%of entire contract along with any acquired fees or costs associated with said project.All material is guaranteed to be as specified. All work shall be completed in a quality manner in accordance with industry standards. ALL ESTIMATE PRICES ARE DISCOUNTED BASED ON CASH OR CHECK PA-YMFNT. CREDIT CARD PAYMEi�iTS ARE SUBJECT TO A 301.MERCHANT CHARGE. Fees,Permits and Washington State Sales tax Total are not included in this estimate: Customer Signature Date 07 / 11 2018