Loading...
HomeMy WebLinkAboutBLD2013-00497 Revised SFR - BLD Permit / Conditions - 1/17/2014 Request To Revise An Approved Plan Permit Number: BLD 2-"�J 3 -Q "I _� Name Parcel Number Phone Number daytime �) Project Address Mailing Address Please provide a complete, detailed description of the proposed revisions to the approved plans: Are two sets of the revised plans or addendum indicating the changes included? ❑ Yes ❑ No Are the approved site plans included? ❑ Yes ❑ No Are the revisions clearly and accurately identified on the plans or addendum? ❑ Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes ❑ No If Yes, Has the engineer or architect approved this revision? ❑ Yes ❑ No Is a stamped and signed approval included with this request? ❑ Yes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? ❑ Yes ❑ No If Yes, Is a revised site plan, with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signature Date: Office Use Only Received by: Date Sent Assigned To Approved By Date Original Valuation: $ ❑ B. Additional Valuation: $ P. � L �/ C f Sq.Ft. x$ $ T 1, Sq. Ft. x $ $ ❑ E.H. Total New Valuation $ Additional Fees: P•W Additional Planning Dept. $ Additional Plan Review $ Additional Conditions/ Comments: Additional Building Permit $ Additional Plumbing $ Additional Mechanical $ Additional E.H.Dept. $ Other $ Total Amount Due: $ Amount To Be Paid Up-Front$ I Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 279 ' IFF, Shelton, WA 98584 Zzol MECHANICAL PERMIT BLD2013-00497 OWNER: RALPH DEWITT LIVING TRUST CONTRACTOR: LICENSE: EXP: RECEIVED: 6/27/2013 SITE ADDRESS: 190 E BLACKWELL ST ALLYN ISSUED: 1/17/2014 PARCEL NUMBER: 122205036001 EXPIRES: 9/20/2015 LEGAL DESCRIPTION: ALLYN BLK: 36 LOT: 1-2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE (ACCESS THROUGH LOT 1 HOUSE LOCATED ON LOT 2) BLACKWELL ST General Information Setback Information Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft. Type of Work: NEW Fire Dist.: 5 Rear: Ft. Slope: Ft.Side 1: Ft. Valuation: Side 2: Ft. Mechanical Fixtures FEES Type Qty. Type By Date Amount Receipt Ventilation Fan 3 Plan Check Fee TW 6/27/2013 $849.78 S220130000C Dryer Vent 1 EH Plan Review TW 6/27/2013 $103.00 S120140000C Exhaust Hood 1 Water Adequacy Plan Review TW 6/27/2013 $103.00 S120140000C Gas Outlets 0 Planning Review Fee TW 6/27/2013 $205.00 S220130000C Woodstove 1 Planning Review Fee TW 6/27/2013 $205.00 S120140000( Propane Tank 0 ADJUST--Plan Check Fee TW 7/3/2013 -$72.80 S120140000( Building State Fee LDK 7/18/2013 $4.50 S120140000C Building Permit Fee LDK 7/18/2013$1,195.35 S120140000( Mechanical Permit Fee LDK 7/18/2013 $201.40 S120140000( Mechanical Base Fee LDK 7/18/2013 $28.50 S120140000C Plumbing Permit Fee LDK 7/18/2013 $93.20 S120140000( Plumbing Base Fee LDK 7/18/2013 $24.70 S120140000( Total $2,940.63 BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 1 of 7 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2013-00497 OWNER: RALPH DEWITT LIVING TRUST RECEIVED: 6/27/2013 CONTRACTOR: LICENSE: EXP: ISSUED: 1/17/2014 SITE ADDRESS: 190 E BLACKWELL ST ALLYN EXPIRES: 7/17/2014 PARCEL NUMBER: 122205036001 LEGAL DESCRIPTION: ALLYN BLK: 36 LOT: 1-2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE BLACKWELL ST General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: 303 Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: Building:1,230 Valuation: $ 135,939.39 Building Height: 28 Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Rear: Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Ventilation Fan 3 Plan Check Fee TW 6/27/2013 $849.78 S2201300000001 Lavatories 2 Dryer Vent 1 EH Plan Review TW 6/27/2013 $ 103.00 S1201400000001 Bath Tubs 1 Exhaust Hood 1 Water Adequacy Plan Revi TW 6/27/2013 $ 103.00 S1201400000001 Showers 1 Gas Outlets 3 Planning Review Fee TW 6/27/2013 $ 114.00 S2201300000001 Clothes Washer 1 Propane Stove 1 Planning Review Fee TW 6/27/2013 $91.00 S1201400000001 Dishwasher 1 Propane Tank 1 ADJUST--Plan Check Fee TW 7/3/2013 $-72.80 S1201400000001 Kitchen Sink 1 Building State Fee LDK 7/18/2013 $4.50 S1201400000001 Hosebibs 2 Building Permit Fee LDK 7/18/2013 $ 1,195.35 S1201400000001 Water Heaters 1 Mechanical Permit Fee LDK 7/18/2013 $201.40 S1201400000001 Mechanical Base Fee LDK 7/18/2013 $28.50 S1201400000001 Plumbing Permit Fee LDK 7/18/2013 $93.20 S1201400000001 Plumbing Base Fee LDK 7/18/2013 $24.70 S1201400000001 Total $2,735.63 BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2013-00497 CONDITIONS FOR BLD2013-00497 1) A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450. The building permit will not be"finaled" until the permit holder can show proof that the access permit from Public Works has been "fin and approved. X G• 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-6 7- 982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depar „Qt prior to any further inspections being performed or approvals granted. X 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removAq#approved documents will result in failure of required building inspections. X 4gt 6) THEr.XFDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X 7) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Buildi epartment prior to any further inspections being performed or approvals granted. X BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 2 of 7 8) Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option 111, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table 9-1 shall be completed: 6 X 9) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area(SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate" and are available in %<or%sheets. The Mason County Permit Center will also have some available. X 0 10) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Ref er�c WSEC 505. X 4 11) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. X ;a BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 3 of 7 12) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 13) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air f tside in accordance with the international codes. X 14) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. N a, dation drains within 30ft, down gradient of drainfield/reserve area. X 15) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 16) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where X Wconnect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 17) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be X char d shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 18) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit r�y�ation. X X' Y BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 4 of 7 19) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project 20) Placem tructure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 21) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinVr regulation, must be reviewed and approved by Mason County prior to construction. X 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspec�all be made prior to requesting additional inspections. X 23) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5'from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bolla st be installed. X 24) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be VX 25) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet t�allation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 5 of 7 26) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be useA until the final inspection has been performed and approved by a Mason County building inspector. X Zf 27) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas(streams, wetlands, slopes, etc.) If you think such��tures exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X ,4� 28) All property lines shall be clearly identified at the time of foundation inspection. X Zoo/ 29) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mas�nty ordinances and building regulations. X 30) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder h revented action from being taken. No more than one extension may be granted. X 31) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connect flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 32) Retaining walls needed to support a surdsuch as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X,, 33) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X i1W 34) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approve Ian"to ensure these structures are shown and meet the setback conditions listed. X 35) Approv r dimensions and setbacks on 08.20.2013 submitted site plan. Setbacks are measured from the furthest projection of the structure. X 36) Temporary erosion control measures must be implemented to prevent water quality degradation o a jacent waters or properties. Silt fencing, straw, or matting must be installed and maintained until upland vegetation has become established. X BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 6 of 7 37) All construction and demolition debris must be removed from the site after project completion. P,,r�! isposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X ys OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature Date OWNER EPRESENTATIVE - CONTRACTOR Print Name (Circle one to i ate) BLD2013-00497 Please refer to the following pages for conditions of this permit. Page 7 of 7 MASON COUNTY PERMIT NO. i;{��13�- BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION 1p)Y] DeUju A !- Lav,,AC CONTRACTOR INFORMATION Owner' ST a nn -YI Company Name Mailin Address ' V e Mailing Address City � Stat Zip Code ,3 City State Zip Code Phone Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address ► Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION -Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No -� Fire District Legal Description 1 I-Z Site Address (Please include street name, street number and city) Directions to site_Mole%7­' o xz 43��A1 e - Will timber be cut and sold in parcel preparation?Yes/ o Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Ye o TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL Use of Building rt .46QA��"a-1 Describe Work No. of Bedroors;a;• No. of Bathrooms-j=9—Square Footage- 1 st Floorj Vic' 2nd Floor �o 3rd Floor_ Basement --6-2 Deck Covered Deck-Q-- Other -49--- Sq.ft.Z-_zg Garage - Attached Detached Carport=e•" Attached--F� Detached-6Q- MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms.a_ No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? 'e)/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provid is accur ,employees of Mason County access to the above described property and structure for review and inspection. BY MEANS OF A REPS DateECTIO�� 1 X \ \r Owner/ 'Representative/ ontrac r indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: ate DEPARTMENTAL REVIEW APPROVED DENIED OTES Building Department -711-60 Udt Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation$ TOTAL FEES Nance i 1� A Parcel F" BLD# TU�V ) Vn Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a sormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface. `Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. T alc late 1rr�Dernr.OUS--Suffices-Please Goinp�ete This F b7e Surface Type Length X Width = Area *All dimensions in feet Buildings X X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = X = Any paved, gravel or packed area per definition above table X = PatioslWalks X X = Any paved, gravel or packed area per definition above table X = Others X X = if,the total.impervious area`of the proposed site X = development is.grea ter than.20D0,squar6 feet a small Parcel Stormwater,Site.Plan.is Require_d.=. Total Impervioijs.Surfaae Area:($urn af:a� areas : �I cq }z _ If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X <�. �yr. v Owner&Contractor(circle one)Date: If the Total Impendous Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this Jurisdiction.A complete copy of the ordinance can be found on the Mason County website: httD//www.co.mason.wa—us/c,ode/c,ommissioners/'Lndex.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48.section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan".This document will assist. you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE IhTTIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS STTE A))(—The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this, or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130) contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has, or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative, or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 RECEIVED AUG 2 0 2013 O, �O - �BSzg T ` PEON.STgTF°� MASON COUNTY A o N DEPARTMENT OF COMMUNITY DEVELOPMENT o N Planning Division 7 N Y ti P O Box 279, Shelton, WA 98584 �° (360)427-9670 1864 NOTIFICATION OF INCOMPLETE APPLICATION July 26, 2013 RALPH DEWITT LIVING TRUST C/O TAMMY DEWITT SUCC TRSEE 5287 MTALIFAN DR 5iCk1 t)tP-jo C-A g2e Parcel No.: 122205036001 Proiect Description: RESIDENCE Dear Applicant: You have submitted a permit application (case no. BLD2013-00497) for proposed construction or development in the county. Upon review of your application, I have determined that the contents of the application are incomplete or do not provide enough detail for review. Therefore, review of your application will not proceed until the necessary information is provided (see the comment section of this letter for details.) Once the information is submitted and the application is complete, I will continue to process your application accordingly. If the additional information is not provided to the County within 180 days of this request, the application shall expire and no further action on the proposed development shall take place. Please contact me at (360) 427-9670, ext. 365 if you have questions. Sincerely, Allan Borden Land Use Planner Mason County Planning Department ) 7/26/2013 Page 1 of 2 BLD2013-00497 1 NOTIFICATION OF INCOMPLETE APPLICATION 7/26/2013 Case No.: BLD2013-00497 Comments: This letter concerns the status of lots on Town of Allyn. Your proposed small home will be over the common property line between two lots in Block 36. The legal description of this property is Block 36, Lots 1 and 2. These two lots have never been combined through a modern parcel combination (DPC) process but are carried together under a single tax number by the Mason County Assessor's Office. Because the Town of Allyn was platted prior to the adoption of modern subdivision laws in 1938, and because the plat does not included an approval signature from a County Official, it is possible that these lots are already legally combined IF it can be proved that these two lots have always been carried under the same deed (because on old plats like this, it is the act of conveyance that actually creates the new lot, not the recording of the plat). It is recommend that the property owners have a title company do a chain of title search to verify whether or not these lots have always been carried together. If you have the chain of title search prepared, please provide a copy to subdivision planner Michael MacSems (located in this office; phone ext. 571) so that an evaluation whether a declaration of parcel combination is possible to resolve the question that the two lots in Allyn may be combined for development purposes. 7/26/2013 Page 2 of 2 BLD2013-00497 MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST Owner's Name: ZkU*_--rywS� Date: 3—kr� Reviewed By: Documents: V Building Permit Application Completed �Stormwater Checklist Planning Intake Checklist Completed, Site plan includes:Allowable building area,roof overhangs,decks,etc. Fire Apparatus Access Road info required? Yes/No nergy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) O Other: Specify: echanicaMo g Application-WATER HEATER FUEL TYPE/LOCATION Engineerin Snow load:�� Seismic: f Stock Plan—approved snow load: Seismic: Manufactured Homes—4 FLOOR PLANS Foundation Type: ANSI/Manufacture method Engineered footing/foundation Basement Decks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required. Construction Plans.\13 COMPLETE SETS — _Plans Le ib _Recognized Scale _Elevation Views Cross Section _Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors) _Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F.??—stairs?) _Deck Framing Plan,incl cov.porch framing Plan Details: Roof framing details,truss lay-out may be needed (Hip and girder location shown) Wall Framing-Does bearing-wall height exceed 10'?(En ine rin may be required) Floor framing: Floor joists(size&spacin O G,Floor beams: — X IQ L• Window headers. Typical header !N__ O Garage header: Foundation: footing size,reinforcement Concrete Walls-Does Concrete Wall Height Excee 8'?(Engineering may be required, see details) (Landings at all exits?Less than 30"above grade?Y/N \I Heated By Furnace-Location of Furnace Fuel type: Fireplace/Stove Information Shown-Fuel Type?_ Location(s): tal rtweh Window Sizes Marked on Plans �( Braced wall panels(shear walls)marked on plans or lateral engineering? �1 2-story garage? (Engineering may be required) V story of two story D1—45%,D2—55% COMMENTS: ENGINEERING REQUIRED Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: ,Snow_psf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3)End of BWP extends more than 1 ft.over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. H:\permit tech building checklist.doc Revised 11-29-2007 1 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON (360) 427-9670 BELFAIR (360) 275-4467 Elma (360) 482-5269 FAx: (360) 427-7798 WEB SITE: www.co.mason.wa.us P.O. Box 279, SHELTON 98584 2012 International Energy Conservation Code, as amended by WAC 51-11 (IECC) Effective July 1, 2013. Ventilation code provisions are located in the 2012 International Residential Code (IRC), 2012 International Mechanical Code (IMC), &2012 International Building Code A complete energy code application form will include information that clearly identifies compliance methods for heat sizing, thermal envelope, and whole-house ventilation. This form includes compliance instructions and information needed. Energy code compliance information, forms, worksheets, and educational information is also available on the Washington State University Extension Energy Program (WSU-EP) website. To access the website go to http://www.energy.wsu.edu/BuildingEfficiency/EnergvCode/2012EnergyCode.aspx). The website includes a heat system sizing calculator. Submit a completed heat sizing calculator worksheet when the building permit is submitted. In addition to the heat sizing calculator the website has helpful compliance information and worksheets for prescriptive and component performance options along with a glazing schedule. INSTRUCTIONS: Complete the Mason County Energy Code application and submit with a heat sizing calculator available on the WSU-EP website, see item #4 below: 1 Identify the compliance method. The most common and simplest approach is the prescriptive method for energy code compliance. See prescriptive table R402.1.1 located at the end of the instructions. The component performance approach referenced in IECC Section R402.1.4 may also be used for energy code compliance. For more information contact Mason County building department staff at (360) 427- 9670 ext. 352 or WSU Energy Program at (360) 956-2042. 2 Identify the whole-house ventilation compliance method. A ventilation system shall be installed in accordance with The International Residential Code, Section M1507. The most common ventilation methods include a whole-house ventilation system using exhaust fans (M1507.3.4) and a whole-house ventilation system integrated with a forced-air system (M1507.3.5). Other ventilation systems include whole-house ventilation system using a supply fan (M1507.3.6) and whole-house ventilation system using a heat-recovery ventilation system (M1507.3.7). If you need additional information we recommend that you discuss with your heating and ventilation system professional. In addition Mason County staff will be happy to discuss the options if you are not sure which compliance option will work for you. 3 Identify the Additional Energy Efficiency Requirements listed in Table R406.2. The drawings included with the building permit application shall identify which options have been selected and the point value of each option. Each one and two-family dwelling unit and townhouses are required to achieve the following minimum number of credits: a) Small dwelling units less than 1500 sq. feet of heated or cooled area and less than 300 sq. ft fenestration area (skylights, doors, windows, etc), or additions to an existing building that is less than 750 sq. ft. of heated area. — 0.5 points b) Medium dwelling units not included in a) above {small dwelling), OR c) below(large dwelling)— 1.5 points c) Large dwelling unit is a dwelling unit that exceeds 5000 sq. ft. of heated or cooled floor area. —2.5 points. 4 Provide a completed heating/cooling system size worksheet to verify compliance to IECC R4O3.6. The calculator/worksheet is available on the WSU-Energy Program website at: http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode/2O12EnergyCode.aspx. Staff can also assist with preparation of the worksheet. 5 To meet the prescriptive option all fenestration products shall comply with the required U-factor listed in Table R402.1.4. Windows, doors, and glazed doors shall have a tested U-factor or .30 or less. When using the small dwelling option for energy credits (a) or component performance approach provide a fenestration schedule that identifies the square feet and U-factor of each item. Fenestration is defined in the IECC as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. 6 Identify the location and fuel type of the heating system, water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of proposed insulation for walls, floors, ceilings, and concrete slab floors on the building plans. 7 Not less than 75% of all permanently installed lamps in lighting fixtures shall be high efficacy lamps. High efficacy lamps are defined in IECC Chapter 2 and are considered compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps, or lamps with a minimum efficacy 40 lumens per watt for lamps 15 watts or less, 50 lumens per watt for lamps over 15 watts to 40 watts, and 60 lumens per watt for lamps over 40 watts. Questions? Call Mason County Community Development at (360) 427-9670 ext. 352. WSEC compliance information and code text is also available on the WSU-Energy Program website at: http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode/2012EnergyCode.aspx. Prescriptive Requirements °,' for Mason County Climate Zone 4-C, Table R402.1.1 Fenestration Glazing U-factor Wall Area% Vaulted AboveWall Slab d on Option of Floor Vertical Skybight Ceiling Ceiling' Grade int below grade Floor Grade (Includes doors, windows,etc. 4C Unlimited .30 .50 R-49 R-38 R-21 10/15/21 int R-30 R-10 inti TB Visit the WSU Energy Program website at: http://www.energy.wsu.edu/BuildingEfficiency/EnergvCode/2012EnergyCode.aspx or call (360) 427-9670 ext. 352 for footnote information. Log & solid timber wall with a min. avg. thickness of 3.5" are exempt from the above grade wall insulation requirements. f MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/Ventilation Code Compliance Application Submit with heatingicooling system size worksheet (see instructions #4) Owner: Parcel#: Type of project: '122c, $6 3(00o t AoMc Total Sq. Ft. 1 S Floor: =2r: Heated Basement: of heated area:: r ,25m s �� o sq� Heating System Type: 4 Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: 0 Prescriptive Option Table R402.1.1 Compliance Method O Component Performance, R402.1.3 — Calculation worksheets required Check one:: O Other (Specify): Check one % Whole House Ventilation system o Whole House Ventilation o Other, Ventilation using exhaust fans&window or Integrated with a Forced Air describe: System wall fresh air vents (M1507.3.4) System (M1507.3.5) Referencing Table R406.2, "Additional Residential Energy Efficiency Requirements," all residential units must develop credits as specified in Table 406.2. Identify and describe which option(s)will be used to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/index.php. Additional Energy a) Description: Small dwelling units with less than 1500 sq. feet of heated or cooled Efficiency space and less than 300 sq. ft fenestration (see definition below) or additions to an Requirements existing building that is less than 750 sq. ft. of heated area. To use this option Energy credits complete a window schedule in order to verify that the fenestration area does not exceed 300 sq. ft. Fenestration is defined in the IECC as skylights, roof windows, uired: vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. —0.5 points �r b) Medium dwelling units not includes in a) above, or b) below— 1.5 points Z6 l Z c) Large dwelling unit is a dwelling unit that exceeds 5000 sq. ft. of heated or cooled floor area. — 2.5 points. Describe Energy Credit Option(s): Using Option number(s): , � ��� l ol�w� 1 � WASHINGTON STATE ENERGY CODE, RESIDENTIAL PROVISIONS TABLE 406.2 ENERGY CREDITS(DEBITS) OPTION DESCRIPTION CREDIT(S) 1 a EFFICIENT BUILDING ENVELOPE la: 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Fenestration U=0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 5%. I b EFFICIENT BUILDING ENVELOPE lb: 1.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Fenestration U=0.25 Wall R-21 plus R-4 Floor R.38 Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 15%. 1c EFFICIENT BUILDING ENVELOPE lc: 2.0 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Fenestration U=0.22 Ceiling and single-rafter or joist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 Basement wall R-21 int plus R-12 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 30%. 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 Compliance based on R402.4.1.2: Reduce the tested air leakage to 4.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a high efficiency fan(maximum 0.35 watts/cfm),not interlocked with the furnace fan ventilation systems using a furnace including an ECM motor are allowed,provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. t 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.70. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: 1.5 Compliance based on Section R402.4.1.2: Reduce the tested air leakagc to 1.5 air changes per hour maximum and All whole house ventilation requirements as detemuned by Section M1507.3 of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.85. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: 0.5 Gas,propane or oil-fired furnace with minimum AFUE of 95% To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: 1.0 Air-source heat pump with minimum HSPF of 8.5 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3c HIGH EFFICIENCY HVAC EQUIPMENT 3c: 2.0 Closed-loop ground source heat pump;with a minimum COP of 3.3 or Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet and minimum COP of 3.6 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3 d HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0 DUCTLESS SPLIT SYSTEM HEAT PUMPS,ZONAL CONTROL: In homes where the primary space heating system is zonal electric heating,a ductless heat pump system shall be installed and provide heating to at least one zone of the housing unit. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM:° 1.0 All heating and cooling system components installed inside the conditioned space.All combustion equipment shall be direct vent or sealed combustion. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat is not permitted under this option. Direct combustion heating equipment with AFUE less than 801/6 is not permitted under this option. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. Y 5a EFFICIENT WATER HEATING 5a: 0.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.62 or Electric water heater with a minimum EF of 0.93. and for both cases All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.b To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and shall specify the maximum flow rates for all showerheads, kitchen sink faucets,and other lavatory faucets. 5b EFFICIENT WATER HEATING 5b: 1.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.82 or Solar water heating supplementing a minimum standard water heater.Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems or Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters or Water heater heated by ground source heat pump meeting the requirements of Option 3c. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and,for solar water heating systems,the calculation of the minimum energy savings. 6 RENEWABLE ELECTRIC ENERGY: 0.5 For each 1200 kWh of electrical generation provided annually by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits.Generation shall be calculated as follows: For solar electric systems,the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PV WATTs. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: The wind turbine power curve;average annual wind speed at the site;frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, provide documentation of solar and wind access,and include a calculation of the minimum annual energy power production. a. Interior Duct Placement.Ducts included as Option 4 of Table R406.2 shall be placed wholly within the heated envelope of the housing unit.The placement shall be inspected and certified to receive the credits associated with this option. Exception: Ducts complying with this section may have up to 5%of the total linear feet of ducts located in the exterior cavities or buffer spaces of the dwelling.If this exception is used the ducts will be tested to the following standards: Post-construction test: Leakage to outdoors shall be less than or equal to 1 CFM per 100 ft2 of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. b. Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and showerheads)shall comply with the following requirements: 1. Residential bathroom lavatory sink faucets: Maximum flow rate-3.8 Umin(1.0 gal/min)when tested in accordance with ASME Al12.18.1/CSA B125.1. 2. Residential kitchen faucets: Maximum flow rate-6.6 Umin(1.75 gal/min)when tested in accordance with ASME Al 12.18.1/CSA B125.1. 3. Residential showerheads: Maximum flow rate-6.6 Umin(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1. r FENESTRATION SCHEDULE USE FOR ENERGY CREDIT, a) SMALL DWELLING OPTION & COMPONENT PERFORMANCE COMPLIANCE List all windows, doors, skylights. (If needed, attach an additional sheet) Fenestration is defined in IECC Chapter 2 as skylights, roof windows, vertical windows, opaque doors, glazed-doors that include products with glass and non-glass glazing materials. Manufacturer Location U-Factor Size Quantity Total rough opening) Square Feet i Total Fenestration: windows, skylights and door area i vim/ .ST �o �9 r� � �' � 4 u� .� �8.,xo �S - SG a k f a i DRIVEWAY A PARKING 12.o kr„� W SET BACK 12' rr \k N` < y b i j 0-2, i N RTH i NOO��Q6 ��I �-0 i���a BLACKWELL STREET i