Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2024-00088 - SWG Application / Design - 3/5/2024
MASON COUNTY 4/5 NB THELTON: ,5427-960.E)(T 84 SHELFAIR 360 776 9 170,EXT 400 4 BELFAIR:360.2]SJ467,EM 400 Public Health & Human Services ELMA:360.482-5269,EXT 400 FAX 380427-7787 On-Site Sewage System Permit: SWG2024-00088 APPLICANT GORST SOLID LANE LLC Phone: Address: PO BOX 727 PORT ORCHARD,WA 98366 OWNER GORST SOLID LANE LLC Phone: Address: PO BOX 727 PORT ORCHARD,WA 98366 SEPTIC DESIGNER PAULAJOHNSON' Phone: 360A98-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 Site Address: E Mason Benson Rd Primary Parcel Number: 221103490043 Permit Description: New SFR-4BR Pressure Bed Permit Submitted Date: 0310512024 Permit Issued Date: 03/20/2024 Issued By: Jeff Wilmoth Current Permit Fees Paid: $805.00 (edai flees m.y"rt uil umnImbil not symm) Permit Expiration Date: 03113/2027 (seaee on aaoam.aKwn) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staffper Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Farm, Record Drawing, and Installation fse must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masonmuntywa.govlhealthlenvironmentalionsiteloss4nepectlonaequest.php or call: 360-427.9670,extension 400. i OFFICIAL USE ONLY MASON COUNTY �EEDD 3 N COMMUNITY SERVICES w PRAIKIGFNN(1ANT. it"NealU wi mm ,.IIiwnnl ;Cow N SWG CDay - c, o ° _ M ON-SITE SEWAGE SYSTEM APPLICATION n A m n APPLICANT PxoNE m Gorst Solid Lane LLC Becky Hoyt (360)710-0645 c MAIUNGPDDRESB-SIREET.CITt STATEZIPCODE a P.O. Box 727 Port Orchard WA 98366 m SITE ADDRESS-STREET.CITI VP CODE .��. E Mason Benson Rd Grapeview WA 98546 I N NAME OF DESIGNER PHONE Arrow Septic Designs (360)898-2255 I �' NAME OF INSTAUUEE MONE 0 PERpMKRTVPE~RK, DRINK INSWATER SOURCE w I ' eII RESIDENT IAL053 �COMMUNRYOSS FL'COMMERCWLOBB IWT ZATEINDIVIDUALWELL ®PRNATET FARWIAELL z IO T'.0 ACEKSI'"S y;PUSUC NNTER SYSTEM JENEWCONSTRUGTIONIUPGRAOES Fj REPAJRIREPLACEMENT OTNERDEAILSf FAER1sRl OTABLE XREPAIR I IW SUBSRTALS ❑SURFACINGSEWAGE ❑EXISTING FAILURE 0SHORELINE ®DESIGNFORIAREOUIRED) 19SEPTICOESIGN(REQUIREO) SEORODUR LOT MZE IA EWAIVEBIS)(IF APPLICABLE) 4BR 1.89 acres x DIRELTIDiS M SITE AND SITE CO1UITION6.R.i I,e co Go out Hwy 3 and turn (L)onto E Mason Benson Rd. Turn at mailbox"403" between I 10 storage and horse arena. Open gate (not locked) and follow driveway to the (R). Park in r field and follow pink ribbons through Scotch broom to test holes. o 0 IA S/IEYIl8TKµ14GED FROMM.VN ROAD M'OTEBTNIXEY MUST BEMIXiEC 1NTM TE8TIKKEMUYBERA W OFFICIAL USE ONLY BELOW THIS LINE UWRALEIFAIWRESNAKE(WISFWgPury % OVOLUNTARV OMAINTENANCESPUMPING 13BUILDINGPERM7 CII0MESAE OCOMPLNNT OOTHER. ON INSPECTOR SOIL LDGB P P R 0 V E MNENTS,fgNDlIGN3 � �� `� M ky oS MAR 2 0 2024 p MASON COUNTY ENVIRONm rnt i; LTH �FcFly 6�o7� JBW Fa SpLCODE . RECORODRAAINSANDINSTAUATONREPORI Va VERY G=GNAVFLLY S-HAND L=LONA go31LT C-DAY E-FSINEMELV R=RCOTS RECUIRED FOR FINALAMROVAL. U 3 TOR BIGNATIIRE OI.TE P 1CAIGNEK 0. PIPATION LATE TN)NpPPROYEDI$SIED SV ATE AXC 3- (3- '1 3-13 r 3 �_ Y T 0 AWIIUkY BE SCANNED ANDAVAILABLE FOR PUBLIC VEWON THE MRSON CCUI W£BSITE REISEDILTrzOIs DESIGN FORM—PAGE ONE Assessor's Forced Number:?2 1 1 0 — 3 4 — 9 0 0 4 3 A design will be reviewed when 3 conies of each of the following are submitted: Completed design form that has been signed and dated. °Scaled layout sketch.including all applicable items on checklist •Scaled plot plan. including all applicable items on checklist. v Cross-section sketch,including all applicable items on checklist. This form may he scanned and available for public view on the Mason County Web site.Maximum r size: 11"X 17' sPPAooR.CEL.DIENTIFICATION VV Designer's Name: Arrow Septic Designs,Inc Petmn\umber: SWG x (360)898-2255 Applicant's Name: ��Solid Lane LLC Designer's Phone Number P.O.Box 727 Designer's Address: 171 EVtnueat a Mailing Address: WA y�gp PortOrcheN WA 983es Union, Cin Cit State Zi State Zi .DESIGN PARAMETERS Treatment Device ❑Glendon Biofilter 0 Sand Filter ❑Mound 0 Sand Lined Dminfield ❑Recirculating Filter,Type: ❑Aerobic Unit Make/Modei 0 Disinfection Unit Makc/Model Other: Drainfseld Type ❑Gravity lid Pressure 0 Trench 61(Bed 0 Sub Surface Drip Septic Tank/Draiofield Specifications Laterals Number of Bedrooms 4 Schedule/Class 40 Daily Flow:Operating Capacity 360 gpd Length 60 ft Daily Flow:Design Flow 480 gpd Diameter 1.25 in Septic Tank Capacity(working) 1,200 gal - Number 4 Receiving Soil Type(I-6) 3 Separation 2.5 ft Receiving Soil Appl.Rate 0.8 gpd/fte Orifices Required Primary Am 600 ft2 Total Number of Orifices 48 Designed Primary Area 600 ft' Diameter 3116 in Designed Reserve Area 600 ftt Spacing 60 in Trench/Bed Width 10 It Manifold Trench/Bed Length 60 ft Schedule/Class 40 Elevation Measurements Length 7.5 It Original Dminfield Area Slope 0.1 % Diameter 1.25 in New Slope,If Altered 0-1 % Preferred manifold configuration used? St Yes 13No DepthofExwvation u"wpr 36 in Transport Pipe from Original Grade M.-slope 36 in Schedule/Cleas 40 Designed Vertical Separation 24+ in Length 100 fit Gravelless Chambers Required? 0Yes 16Nc 0Optional Diameter 2 In Pump Required? Id Yes ONo Dosing and Pump Chamber Pump/Siphon Specifications Numberofdoses/day 4 Diff.in Elevation Between Pump&Uppermost Orifice 15 R Dose quantity 120 gal Dminfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 1,200 gel Uppermost Orifice Bf Higher ❑Lower than Pump Shutoff Pump controls:Please check those required. Capacity®Total Pressure Head 28.32 gpm tdTimer f+'dElapse Meter Event Counter Calculated Total Pressure Head 20.34 ft If Timer: Pump on 2 mflnutea; Pump off 6 hours Comments PPRO MAR 2 0 2024 MASON COUNTY ENVIRONMENTAL HEALTH V� JBW DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 1 1 0 — 3 4 — 9 0 0 4 3 Permit Number SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Crone-Section Sketch El Test hole locations 19 Drainfield.orientation and layout Reference depth from original grade: Ed Soil logs Ef Trench/bed dimensions and Ed Septic tank 0 Property lines critical distances within layout 61 Drainfield cover III Existingand ❑ D-BoxfValve box locations proposed d P� wells Reference depth from original grade within 100 ft of property 19 Septic tank/pump chamber and restrictive strata: 10 Measurements to cuts,banks,and locations lif Laterals,uench/bed,top and surface water and critical areas 19 Observation port location bottom ❑ Location and orientation of 19 Clean-out location ❑ Curtain drain collector curtain drain and all absorption lid Manifold placement ❑ Sand augmentation components Iff Orifice placement Other cross-section detail: III Location and dimension of Ef Lateral placement with distance RF Observation ports/clean-outs primary system and reserve area to edge of bed Other Information Id Buildings 16 Audiblelvisual eferenced Yes No Ia Direction of slope indicator R! Scale of dra on scale fff ❑ Design staked out 16 Waterlines bar ❑ Rj Recorded Notices attached It Roads,easements,driveways, ` (h, ❑ Waiver(s)attached parking °� "]. 61 ❑Pump curve attached la North arrow and scale drawing ❑ Gf Evaluation of failure shown on scale bar G . sr6oase ` Non-residential r.eaidestial justification ! � PAOLq JOY JOHNat1N �''t1 t [3 Ef Waste strength { Mi t� .(❑ al F10W DESIGN APPROVAL The undersigned designer most bi fled b ins ler at time of installation Ed Yes ❑ No Vt'`- 3-S-Z`f- Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and d ermined it to be in compliance with state and local o e regulations: �(m— i 3 -�-_-2 � En ro 1 Health Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: v' The design is stamped"Approved"by Mason County Public Health. 3 _ l3 _ 2 - The Onsite Sewage Permit has not expired,the Permit Expiration Date is: Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/72015 ewvwoteeh Ewg�weeriwg Geoter4twLepL•F.wvLYpwYNLNkaI•Drniwagt•12.ppdwplJ. April 21,2024 Gorst Solid Lane,LZC PO Box 727 Port Orchard,Washington 95366 RE: Geotechnical Evaluation of On-Site Septic System XXX E Mason Benson Road,Cr peview,Washington. Parcel 22110-34-90043 To Whom It May Concern, Envirmech Engineering (Envirotech)completed a site visit on April 17, 2024 in the property in order to observe surface and subsurface conditions. This georechnical evaluation addresses the proposed on-site septic system with relation to landslide hazards on and near the property. Information collected from site observations and field testing was completed by Michael Staten with Envimtech. Subsurface conditions were visually classified as a shallow 1.5-foot layer of silty sand with gravel (SM) overlying poorly graded sand with gravel (SP)to a depth of at least 6 feet. The septic drainfield area is flat to slightly sloping with steeper grades at least 50 feet beyond. Critical descending slopes exceeding 40% were observed on the property, downslope and away from the planned septic rank and drainfield areas. Based on our slope stability analysis, it is our opinion that the proposed septic system will not influence the nearby critical descending slopes exceeding 40%,provided that vegetation remains undisturbed on the critical slopes. Earth movement remains a potential within the critical sloping areas, but this feature is located outside the influence zone.The property my or may not experience shallow landslides.However, we believe that the proposed dminfield has a sufficient setback from the top of critical slope,and will not contribute to furore landslides. If you have any questions or need any further assistance,please contact Michael Staten a[360-275-9374. Sincerely, Envirotech Engineering 6l --'9 xasrrrrU� t' arzlrza Michael Staten,P.E. Project Director P isox-9 4 Isdfal"WaSbiwgtpw98528 C>ff. �27"374 ULL: 36 649-6 5 a : .� r > `o} R su3jS z m a ! p3T [)[)l1e igl�l3 E::y. c o • _ ate rc ' w •.ESE -� rn w p U Iia• i , a . ilF�lY£ •} x EF _ 37 a a:^: -s: i O �'gr - e`,•. m a> { z a.�,. ]e z fjglia �F` F F! it q 1fl v�&• i p €°c3 § y:l� I yr d� } t ! a oP a .z 1. f g s zFSi• jf' gjj4 ¢F 3$ > ;O F€E iE.�Fk pssi =�P€ 3�gt3 i{S� a "F gt § z "C i IXE 91lS1sY1 s B` c >a3 9 b — .1. _ A . � Y Y i ` �' ljtlI.jj 2xi S 3- '• is, i;i 1-11332 { EI^3lkfi • a� - .,.acne � •••a�F3 3�sE MAR 2 0 202§ MASON COUNTY ENVRONMENTAL HEALTH JBW ueVlzoo D R+ v E wFFy \ �1i'Kb�p�RYE ggp '^ Pa°p° seo "� 1 I 4 $R. H°Us� AR.�P = A%Tasr Wo1� O Audio-visual Alarm yw=k�"@ �YeY+e,•,d 0 —bo`YY e,,a © Cleanout �Z; © 1200 Gallon Septic Tank 2-Compartment with E'ffiuent Filter O4 17.00 Gallon Pomp Cham Mom' e 10 FAULAJJYJONNS°N'$ N Su; �Yeras °"t` SLRLE t° °A }15 bw.t°U.�sc-Fiou�.K 0 20 4o bo BO PLOT 9U4K R;=cKv F-�ov t' �,aRCEi�22tto-�4- goo43 �� � MASnN $ENsou Rp � P P R O V ReE �'EvJ wA 9as A 7 MAR 2 0 2024 _ JBW I � p, 3 tz� Z Drainfield_Bed. .T2p View bb" Scxfex '. 1"=to' (Y) (90A 1.25" Schad 40 Lateral Qij 3/16" orifices boo"O.C. o' S' b' ,S' 20' per lateral... lst & last 3o- frm end of bed. T p0,<9 pz PA J01 JOIINSON SCREW ON CAP NOTE, 45 DEGREE ELBOW 10�OBSERVATION PORTS-- LATERAL PVC PIPE FROM BOTTOM OF TRENCH END OF TO FINISHED GRADE. REMOVASLr DITCH CAP SHALL BE INSTALLED ON DETAIL OBSERVATION PORT PIPE. ANCHOR ON CLEAN OUT BOTTOM WITH GLUED ON TEE. MINIMUM OF IN SYSTEM. NOTE, CLEANOUT TO BE FROM 0 INCHES BELOW FINISHED GRADE. Ty p MARK ENDS WITH REBAR. CLEAN oloSeyvme ;ati REQUIRED AT END OF EACH LATE1 -- QOr'F �4 � ryS OR�A``aQ.t ..a L b. (o` A PPROVE YASON MAR 2 01024 b— °'�l`�"—° T H• fNVIRc4VE1vT, jaw -,EA,-, mo DG p)114:1L1. a ENo VIEW —,UTS, Length Length Orifice # Distance from Distance from Lateral# In. Ft. SpacingOrifices Feeder Line(In.) Cleanout(In. 1 720 60 60 12 30 30 2 72 660 60 12 30 30 3 720 60 60 12 30 30 4 720 60 60 1 12 1 30 30 Total Lateral Len th 240 Total#Orifices 48 GPM= 28.32 Dynamic Head Calculations Selected residual pressure: 2 ft. Length (Ft.) #Orifices Transport Pipe 100 48 1.40 ft. Feeder Total Lateral Line Length Lateral#1 60 4 64 12 0.49 ft. Lateral#2 60 2 62 12 0.48 ft. Lateral#3 60 2 62 12 0.48 ft. Lateral#4 60 4 64 12 0.49 ft Total Elevation Lift 15.00 ft. Total Dynamic Head 20.34 ft. '.y . h L t/ SIOUApY PAVU JOY JOHNSON . 'CiC' r NE ' owses A PPROVE CGUNTY Roza ENVIRONMENTAL HEALTH Jgw sib i • Bronu construction available(139 series) • High head version available(145 series) "-- - Double shaft seal versions avaitable for added protection Flow-Mate on models 1401145. For more information,see Technical Data Sheets FM2782,FM2783. In high head dewatering or effluent applications where pumping performance is critical, this robust to . °�family of pumps is knownfor reliability, durability and performance. Thesepumps are especially suited for harsh environments.Zoeller'scoolrundesign and corrosion-resistant,powder coated epoxy finish add up to a long-lastingtrouble-free productAPPLICItTIONB:STEP or onsite applications watumansfefLight commercial dewatering { SPECIFICATIONS:discharge �g • 1-1/2"NPT disNarge • 112 HP through 1 HP NUKE IN WE USA • Avaiable In automatic or nonautomatic NNAYUNna01a1NI Model 137,139,140:112"(12 mm)spherical solids , capacity with vortex impetler + • Model 145:3/4"(19 mm)spherical solids capacity with voneximpe0er •°•""'" �^ ^r y ats PUMP PERFORMCURVE Dose-Matebr ttla'""t m MODEL I5 15V This is our fastest growing line of effluent H wIn pumps.The 150 series is truly a workhorse designed for reliability under extreme conditions in an effluent environment 150 series pump curves cover a wide range w asIN of applications. They are well suited to s< w applications with low pressure pipe(LPP) and enhanced flow STEP systems.Zoeller's a- as III, cool run design and corrosion-resistant, powder coated epoxy finish, in addition a m to the hermetically sealed, oil-filled motor �a and non-clogging vortex impeller add up to a long-lasting,trouble-free product 10 APPLIDu3TION8: STEP or onsite applications ° NADEIN 11E 118A w m w +a w w m w w i°° • LigMcommercialdewatering MANDwria aaunxs SPECIFICATIONS: urtx3 o m tz° fm mo aw m an sm • 1-1/2-NPT discharge 3/10 HP through 112 HP � PVA'D V E • Available in nonautomatic or with a variable level piggyback mechanicatswitch MAR 2 p pp2 1/2"(12 mm)spherical solids capacity with vortex MASON COUNTY ENVIRO theunoplestic impeller NMENTAL HEALTH For more information,see Technical Data Sheet FM2784. Jew r m ALL rights reserved. ZOELLER PUMP Co. 1 502-7783731 1 800 128-7867 1 zoelterpumps.com 9 not O o t = .m°Gokf� PMWCDimibm°°Wipes ,SEMPRIM . - UoWrm9mTWffSELL 1AODMFXM _ F. FWW naamomw .PJAW FRM 2T" t MAR 1 pV D IaS�'C©UNiVEN2024 VIRp N'Nr 111 6v^cx_ qECURWLmwmlcwnw+rsEwL J Aux®s way SERVICE VALVE pMno eRAOE , — m SWM -TANK ---•roae��sao TAIR _ EMCRUENCY srarAOE AN VMME aw ALVE• fdWs/AMALARKLEVEL MolOML7IMBROFFLEVEL VIORKOG VOLEME --woe RJOATSM �awrMa Is = - wr PUMP CHAMBER LTYPW LI 'A611E�® Septic Tanks must meet standards required by WAC chapter 246 272C and FlCuRE V �ufacna er must be on Dept of Health list of registered sewage teaks. .._•..+err. Pa 35 of65 C vww Septic ooicgm INSTALLATION&MAINTENANCE Pressure Distribution Systems-Bed ." . NikPAULA JOY JOHNSON 1. Install Laterals with contour of the ground. L' 2. Install bed bottom level. EM 2 3. Install locator tape or rebar at each and of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. Minimum of 2 required in each bed with bottom extending to the dminrock/native soil interface. Glue"T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals(cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch requited. S. Install 1/8"mesh non-corrosive pump screen(min. 12 sq. ft. surface area,not to interfere with controls or floats.) Or pump screen may be substituted with Bio-Tube in septic tank. Pull bio-tube every 6-12 months and flush back into tank 9. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 10.Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue), after pressure test and Environmental Health Dept. approval,rum orifices down(6 o'clock)and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position 11.Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 12. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 13. Divert all storm water runoff away from on-site sewage system. 14.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the dtainfield and reserve area 15.Have the septic tank and pump chamber pumped or inspected every 3 to 5 years. 16.No vehicular traffic over drainfield area 17.Inspect floats,clean filters, and test high water level alarm every 6-12 months as needed. IS.All materials and workmanship must meet County and State regulations. 19. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 20. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 21.All pressure systems with a pump chamber outlet higher than the drainfield must have a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning. 22. All transport lines under driveways or parking areas must be encased to prevent crushing. 23. Homeowner is responsible for all property lines. P P R 0 V E MAR 2 0 2024 MASON COUNTY ENVIRONMENTAL HEALTH �� JBW