Loading...
HomeMy WebLinkAboutBLD2008-01051 SFR - BLD Permit / Conditions - 10/28/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 i� RESIDENTIAL BUILDING PERMIT BLD2008-01051 OWNER: DREW DAVIES RECEIVED: 8/19/2008 CONTRACTOR: LICENSE: EXP: ISSUED: 10/28/2008 SITE ADDRESS: ELL ST ALLYN EXPIRES: 4/28/2009 PARCEL NUMBE ;2� LEGAL DESCRIPTION: BLK 35 LOT 7 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR HWY 3 TO WADE ST THREE BLOCKS W UP HILL R ON BLACKWELL TO STOCK SET UP 2006-0051 SITE ON L General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type ofConstr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 3 No. of Stories: 2 Occ. Load: Building:1,305 Garage-Attached 540 Valuation: Building Height: Occ. Status: Primary Basement:243 COVPORCH 12 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 20.0 Ft. Shoreline: Ft. Water Body: NONE 5 Shoreline Desi SEPA?: No Model: Width: Ft. Rear: W 2 .0 Ft. Slope: Ft. Side 1: N .0 Ft. 9.: Not Applicable Year: Serial No.: Side 2: S 5.0 Ft. I I Comp. Plan Desig.: Urban Growth Area BLD2008-01051 Please referto the following pages for conditions of this permit. 1 of 5 Plumbing Fixtures Mechanical Fixtures FEES •. Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KS 8/19/2008 $726.02 S12008000 Hosebibs 3 Furnace<100K 1 Planning Review Fee KS 8/19/2008 $190.00 Si2008000 Kitchen Sick 1 Ventilation Fan 3 Address Fee KS 8/19/2008 $162.00 Si2o08000 Lavatories 3 Dryer Vent 1 EH Plan Review KS 8/19/2008 $40.00 S12oo8o0o Water Closets (Toilets) 2 Water Adequacy Plan Review KS 8/19/2008 $40.00 S12008000 Water Heaters 1 ADJUST--Plan Check Fee ARC 8/28/2008 $10.92 S12008000 Bath Tubs 2 Building State Fee ARC 8/29/2008 $4.50 S12008000 Clothes Washer 1 Building Permit Fee ARC 8/29/2008 $1,133.75 S12008000 Mechanical Fee ARC 8/29/2008 $63.05 Si2008000 Mechanical Base Fee ARC 8/29/2008 $26.60 S12008000 Plumbing Fee ARC 8/29/2008 $95.71 S12008000 Plumbing Base Fee ARC 8/29/2008 $23.10 S12008000 Geotechnical Asses. Report RDH 9/12/2008 $33.00 S12008000 EH Waiver Review KS 10/20/200 $110.00 S12008000 EH Plan Review CEW 10/27/200 $60.00 S12008000 Total $2,718.65 CASE NOTES FOR BLD2008-01051 CONDITIONS FOR BLD20 0 8-01 0 51 1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access roa oadsA,e required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roa o YwiXh a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ,! 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are en44sks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-6 -0 8Thk person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be gran . In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department p 'a y further inspections being performed or approvals granted. X 4) Owner/Agent -responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X BLD2008-01051 Please referto the following pages for conditions of this permit. 2 of 5 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The per it holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of ap 2'6ve t�oc�tir�r ents will result in failure of required building inspections. X /) J a 6) This basemen is apprgmqd as un-heated space. If at any time this area is to be used for anything other than what it is approved for, a change of use permit shal fie a fo , reviewed and approved prior to the change. X V _ 7) All slabs witathefted space shall be insulated to a minimum R-10 for at least 24". Monolithic slabs shall be insulated around the perimeter from the top of the slb'ttom of the footing (if in future going to heat basement) X /// 8) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 9) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Build 2nyepVt prior to any further inspections being performed or approvals granted. 10) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: Prescriptive option IV, Window(Max U-Factor):0.35, Skylight(Max U-Factor):0.58, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-38 (see exception), Slab Insulation R-10. Exception: R-30 insulation may be installed, up to 500 sq. ft., in single rafter or joist vaulted ceilings where the distance of the top of the ceiling and the undersid f sheathing is less than 12-inches and there is 1-inch vented airspace above the insulation. X ! ,l_ro 11) Per 2003 IRC -SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC =� (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X� 12) Per IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance wittl-fti plicable provisions of this section and the manufacturer's installation instructions. BLD2008-01051 Please referto the following pages for conditions of this permit. 3 of 5 13) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is n g�that all components of the stormwater management system have been installed as approved on the stormwater site plan. X j`�� n 14) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged an"allll be'upilected by the Building Department prior to any further inspections being performed or approvals granted. X 15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington.P Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev c� X 16) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance ust be reviewed and approved by Mason County prior to construction. X �IJ 17) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the intern tional codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector sh II prior to requesting additional inspections. v 18) All property lines shall be clearly identified at the time of foundation inspection. X �► 19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason C t es and building regulations. X 20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder hav . nte¢'alption from being taken. No more than one extension may be granted. X BLD2008-01051 Please referto the following pages for conditions of this permit. 4 of 5 • 21) , Retaining walls needed to support a surcharge h as str tures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 22) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved S nsure these structures are shown and meet the setback conditions listed. •X %LrL 23) This building permit is issued on condition that final occupancy approval shall not be granted until such time that; 1) This property is connected to an eight inch gravity sewer line to be constructed according to County standards. 2) Said sewer line shall be in conformance with the general sewer development plan for the North Allyn Sewer Basin. 3)All the infrastructure installed and constructed to connect this property to sewer is accepted by the Mason County Department of Utilities and Waste Management prior to occupancy. 4) The perm' holder pays all appropriate sewer connection charges, fees, and monthly service charges. X 24) Owner must show proof of satisfactory water sample and well log OR valid connection to an approved public water supply prior to temporary/permanent occupancy of t Maqc-e) X !l This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property a str ture fo ie a inspection. OWN ER OR AGENT: i DATE:_� Z BLD2008-01051 Please refer to the following pages for conditions of this permit. 5 of 5 I Og � MASON COUNTY Sewer Lj Water Perm Permit No. 1&44 Date k -3D -r0'Owner V t e-s Contractor Job Description Job Location 94 ! .4 akwe,11- Inspection B Approved for Cover < o� Date Remarks N` Applicant Must call issued By Utilities & Waste Management For Required Inspection Post this 360-427-9670 card in a conspicuous Ext. 652 at Front of Premises 5 o CONCRETE MECHANICA ^'� MANUFACTURED HOME o Date o Footings J Setbacks Ribbons m w Gas Piping Cl) b interior Date By interior-Data By Dale B; can Exterior Dale Extwior-mate av Set-upX Point Load/Isolated Footings INSULATION Dd1e l3v m Date By EG SLAB INSULATION �� FIRE DEPARTMENTDate v v Foundation Walls Floors Date; BY Date Id• r/r By Dana By DECKS FRAMING Cd-✓O Walls ^n Date By Date y- By Data - By rom PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwor t Atli Date By Type' Dale By .,, Date By o wv DRYWALL TYPO Mt Brace Walt Date By W Gate L O y By"IR Dale By FINAL INSPECTION w wafer Line Fire Seporation Iv Date 8 y / Date B y Data �.�,v5 By l/� 40 00 Pass or Request Inspect. Type of Insp. Fail Date ©ate Done By Comments o CD s Z i S gal bb CL_ caa�Z J'i✓9c` W 0 CS7a�,r� Ly,✓ 0 MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION . CONTRACTOR INFORMATION Owner a ,t w ✓� ® Company Name 's Mailing Address -�7` 109 Mailing Address City tate f J�Zip Code " City Mate Zip Code Phon Other Pp.,-, !-70' 3A Phone Other Ph. Lien/Title older ;����' ' Contractor Reg. f Exp. E mail address �i� l _ E Mail Address Drivers Lic.# DOB 2 S"/d i Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. y 7 Fire District Legal Description r - ' -` c Site Address (Please include street name, street number and city) Directions to site - - 40 o Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units - 1 st Floor 24 �• 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS lype of Fixture No. of Fixtures Fees Fuel Type:Electrir 7' LPC- Natural Gas Heat Pump_ Toilets '� Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers -.. Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date: Owner/Owners Representative/Contractor (indicate which one) �1' FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group-Tvpe Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Ins ection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Violation Fee TOTAL FEES MASON COUNTY PERMIT NOS�'��-�./���' / BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT_ FORMATIO CONTRACTOR INFORMATION Owner r e "..' a V+ OS Company Name Mailin A ress Q o a Mailing Address City State � '�Zip Code 5 �`,� City State Zip Code Phone 76 Other Ph. 973& Phone Other Ph. Lien/Title Holder t- Contractor Reg. # Exp. Email address 1 04' L Cow E Mail Address Drivers Lic.# 3 GoS"D0B Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System LName of Water System �' Well Sewer System�- Name of Sewer System ° r 7x c PARCEL INFORMATION - 12 Digit arcel J�10. 2' 0 0 Fire District Legal Description- Site Site Address (Please include street name, street number and city) X Direcionstosite 3 TQ cc/o&_' 57/'-a T t"' vg_ /jc/cS Will timber be cut and sold in parcel preparation?Yes/ No Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New-Add Alt Repair Cher ^- PRIINARY RESIDENCE ❑ SEASONAL ❑ Use of Building "r1� Describe Work u✓ h ✓S� No. of Bedro No. of r �- quare Footage- 1st FI r /3 v�" 2nd Floor s— g 3rd Floor Basement ck Covered DeckOther Sq. ft. Garage 63 Attached SST Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above described property and structur or review and inspection. This permit/application becomes null &void if work or authorized construction is not corn men)•bd within 180 da s r if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF PROGRESS INSPE TION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X ..� Date 6n�er/Ow ers Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by--::II Date DEPARTMENTAL REVIEW APP V DENIED NOTES Building Department Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee dd i Z EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee I NO Ckf-- Pre-Paid at Submittal Valuation $ j� 3 S2. 2 TOTAL FEES ola - 12/f jCY6. 0,3 grow a4 - 12 g, 3s q-. e>AO PIS✓ 7z(,,O4 Aze,a) el*Al- 7 3 6,q� t4a !34 5e .�J- viv x ?f-74 (3 /a-e-L —t-8 5 T lo—g,7 , Vol S * y` O o N t5lr Sti back fit!iA ✓p TO •Z � �r1 Gu rSrv�n � for �Jv 0ve rh�r•� i v s v o / 4 , N � r MASON Ap"OVED P L A N N flill G SITE DCD PLANNING E PLAN REQUIRED TO BE O CHANG S BE TO APPROVAL ROVAL Date I� J _j Name 9z tJ 00,,fel Parcel# /ZZZ J S'y 35C D-? BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. Jw Surface Type Length X Width = Area " All dimensions in feet Buildings X X = Measurements for buildings are taken at the X - perimeter of the farthest projections(example: eaves/gutters) X = Driveways 44 X YO = 0 X = Len h of drive begins at the right of way x p IN TH� Parking Areas X = X FA5 ved, gravel or packed area per definition above table X - Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described p p y fo v' and inspection as may be required. X — wn /Agent/Contractor(circle one)Date: If the Total Im ervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 IDENT L TTAL CHECKL Owner's Nae` : _ e: Reviewed By: m Documents: Building permit application complete STORM WATER WORKSHEET COMPLETE?❑ Q Planning intake checklist complete Site plan includes allowable building area, roo erhands, decks, etc. Fire apparatus access road info required: Y /N Energy code application O Electric wal ter Electric central furnace O LPG Furnace O HP w/elec. Fum. O HP w/LPG furn. O Boiler(heat type) O Other: Specify Mechanical/plumbing application—WATER HEATER fuel type/location: Engineerin Yes o - Snow Load: Seismic: _ Stock plan: PROVED Snow boad: Seismic: Manufactured Homes—4 FLOOR PLANS Foundation type: ❑ ANSI/Manf:Method ❑ Engineered footing/found. ❑ Basement Decks: ❑ Covered? ❑ Uncovered over 4 x 6 and 30"? - construction plans required Construction Plans: 3 COMPLETE XT�SPlans legible ecognized scale Elevation views Cross section Foundation plan Roof framing plan Floor plan—use of rooms noted(all floors) ❑ Floor framing—all floor IXe Deck framing including covered porch framing Plan Details: Roof framing details,truss layout may be needed(hip and girder location shown) t v 5t A UCTVGtSSr�S Wall framing—does bearing wall height exceed 10' (engineering may be required). ' loor flaming: floor joists j spacing? 1(0 floor beams. Window headers: typical header Garage door header: a (ib V� =undation: footing size,reinforcement El, e walls—does concrete wall height ex '? (engineering may be required) Landings at all exits? Less than 30"above grade. N Heated by furnace—location: G Ae&s�� W> lace/stove information shown—fuel type: Location(s): indow sizes marked on plans Braced wall panels s walls)marked on plans? ❑ 2-story gara . (engine ay be required) I"story of two story D 1—45%,D2—55% COMMENTS: ENGINEERING REQUIRED �X Braced wall panels✓brace wall lines are not marked on plans (R602.10) r] Amount and location of bracing does not meet minimum required in Table R602.10.0 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: Snow_�sf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of dne following conditions occur: ❑ 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' ❑ 2) a.Roof/floor is not laterally supported on all edges b.Portion of roof/floor extend>than 6 ft.beyond the braced wall line. ❑ 3)End_of BWP extends more than 1 ft over an opening more than 8 ft in width below. ❑ 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. ❑ 5)Portions of floor level are offset vertically ❑ 6)Shear wall lines do not occur in two perpendicular directions. ❑ 7)When a story above grade includes masonry or concrete construction(fireplaces/chimneys/veneer)entire_story shall be designed in accordance with accepted engineering practice. Wpermit tech checklist-02-05-2008