HomeMy WebLinkAboutBLD2013-00670 Cancelled Heat Pump and Air Handler - BLD Permit / Conditions - 8/12/2013 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Shelton, WA 98584
Irf
MECHANICAL PERMIT BLD2013-00670
OWNER: JOHN RICKETTS RECEIVED: 8/12/2013
CONTRACTOR: FREEDOM HEATNG &A/C LLC 1.360.870.9737 LICENSE: FREEDHA959KC EXP: 5/3/2015 ISSUED: 8/12/2013
SITE ADDRESS: 340 E OLYMPIC VISTA DR UNION EXPIRES: 2/12/2014
PARCEL NUMBER: 322345100022
LEGAL DESCRIPTION: OLYMPIC VISTA TR 22 &VAC OLYMPIC VISTA DR
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
HEATPUMP AND AIRHANDLER
s
General Information I I Set),ANnformation
Type of Use: SFArea: Fro : Shoreline: Ft.
Rea Slope: Ft.
Type of Work: MECnsip.
Dist.: 6 Side . Ft.
Valuation: id Ft.
Mechanic I Fixtures FEES
Type Qt . Type By Date Amount Receipt
Furnace<100K 1 Mechanical Permit Fee TW 8/12/2013 $36.50 S220130000(
Heat Pump 1 Mechanical Base Fee TW 8/12/2013 $28.50 S220130000(
Total $65.00
BLD2013-00670 Please refer to the following pages for conditions of this permit. Page 1 of 5
CASE NOTES FOR
BLD2013-00670
CONDITIONS FOR
BLD2013-00670
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. Th igning this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) Owner/Agent s risible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
3) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occup py is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X
BLD2013-00670 Please refer to the following pages for conditions of this permit. Page 2 of 5
r 4) Installation of heating equipment in a single-tamiiy resiaence snail meet the requirements of the current vvasnington state Lnergy uoae, appiicaoie
sections of the IRC and IMC.
Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems
are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for
inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal
ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or
rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in
accordance to WSEC Section 1411.
X
5 "
BLD2013-00670 Please refer to the following pages for conditions of this permit. Page 3 of 5
r -5) Those parts of heating systems that are altered or replaced shall comply with the current Washington State Energy Code, Section 503. When a
space-conditioning system is altered by the installation or replacement of space conditioning equipment (including replacement of the air handler,
outdoor condensing unit of a split system air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger), the duct system that is
connected to the new or replacement space-conditioning equipment shall be tested as specified in RS-33. The test results shall be provided to the
Mason County Building Department at the final inspection.
The new and replaced heating equipment shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and
IMC.
New and replaced heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing
HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall
be available for inspection during inspection.
Referencing IRC M1601.4, all new ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be
made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid
fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive
tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for
pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be
mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp
joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three
sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the
manufacturer's installation instructions.
Duct tape is NOT permitted as a sealant on any new duct systems. When new ducts are located in unheated spaces the ducts shall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
All new or replaced heating equipment shall meet the requirements o�etional Appliance Energy Conservation Act(NAECA) and be so labeled.
(WSEC503.4) or in accordance to WSEC Section 1411. X
6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinar�e d building regulations.
X �
7) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have pre ven ,�etion from being taken. No more than one extension may be granted.
X
BLD2013-00670 Please refer to the following pages for conditions of this permit. Page 4 of 5
r
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any
time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be
occupied. Proof of continuation of work is by means of a progress inspection.The qwner or the agent on the owners behalf, represents that the information provided is accurate
and grants employees of Mason Cqjuny access to the above described preiperty and structure for review and inspection.
OWNER OR AGENT: DATE:
BLD2013-00670 Please refer to the following pages for conditions of this permit. Page 5 of 5
to
o CONCRETE Gas Piping MANUFACTURED HOMENJ
n
CD Interior-Date By
le Footings/Setbacks Ribbons X
Exiercw-Date By m
rn Date INSULATION Da By
o Foundation Walls BG I SLAB INSULATION Set-up y
t_
Data By Date By Date By 0
F1OO�FRAMING FIRE DEPARTMENT =
Z
Date By Date By
Date 6y Walls
PLUMBING Date By DECKS
Da to By
Groundwork Vault
TANKS
Date By Date By Date By
Attic
D.W.V
Date By OTHER
Date By DRYWALL Type:Date By
Water Line Data BY Type:
Date By Int.Brace Wall Date By W
MECHANICAL Date BY0 FINAL. INSPECTION �
m Fire SeperationCD
O
Da
D By Date
CD By Date By
O
Pass or Request Inspect.
oType of Insp. Fail Date Date Done By Comments c
0
f '
cn
m
cD
y
6'
O
n
O
7
a
O
7
(/1
O
S
y
N
3
N
(L]
fD
0