Loading...
HomeMy WebLinkAboutBLD2016-01102 SFR - BLD Permit / Conditions - 12/22/2016 Inspection Line (360)427-7262 �PS�N aot, MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County 615 W Alder St Shelton, WA 98584 Mi4 RESIDENTIAL BUILDING PERMIT BLD2016-01102 OWNER: KENNY CHAN CHE RECEIVED: 11/9/2016 CONTRACTOR: HI LINE HOMES LICENSE: HILINH*983BD EXP: 11/8/2017 ISSUED: 12/22/2016 SITE ADDRESS: 230 E NORTH BAY RD ALLYN EXPIRES: 6/22/2017 PARCEL NUMBER: 122205019002 LEGAL DESCRIPTION: ALLYN BLK: 19 LOTS: 7-8 & N 20' LOT: 6 &VAC WINGATEA 10' SHERWOOD AVE ADJ PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR: 3 BEDROOM/3 BATH = 1789 SQ FT HOME General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp. Area: No. of Bathrooms: 3 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 2 Occ. Load: 8 Building:1,789 Valuation: $ 201,530.85 Building Height: 23 Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: W 10.0 Ft. Shoreline: Ft. Water Body: CASE INLET Rear: E 25.0 Ft. Slope: Ft. SEPA?: Unkn Model: Width: Ft. Shoreline Desig.: U&an Side 1: N 10.0 Ft. Year: Serial No.: Side 2: S 30.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 3 Heat Pump 1 Plan Check Fee JBN 11/9/2016 $ 1,017.22 32201600000001 Lavatories 4 Ventilation Fan 4 EH Plan Review JBN 11/9/2016 $205.00 S220160000000 Bath Tubs 2 Exhaust Hood 1 Planning Review Fee JBN 11/9/2016 $205.00 S220160000000i Showers 1 Dryer Vent 1 Building State Fee SLC 12/6/2016 $4.50 S1201600000001 Water Heaters 1 Building Permit Fee SLC 12/6/2016 $ 1,564.95 S1201600000001 Clothes Washer 1 Mechanical Permit Fee SLC 12/6/2016 $76.40 S120160000000i Kitchen Sink 2 Mechanical Base Fee SLC 12/6/2016 $28.50 S1201600000001 Dishwasher 1 Plumbing Permit Fee SLC 12/6/2016 $ 136.70 S120160000000i Hosebibs 2 Plumbing Base Fee SLC 12/6/2016 $24.70 S1201600000001 Total $3,262.97 BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2016-01102 CONDITIONS FOR BLD2016-01102 1) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAY. X 2) Inspection by utility department required prior to final/temporary occupancy. X /) L/Z ,X/—— 3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The persoq signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2� 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any f rther inspections being performed or approvals granted. X i2 <�:_- 5) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. Xf 6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or r moval of approved will result in failure of required building inspections. 7) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X .. l BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 2 of 7 8) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 9) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credits from R406.2 shall be completed as follows: 1A- U=0.28, FLOOR R-38, OR REDUCE TOTAL UA BY 5% (0.5 CREDITS) 3D- DUCTLESS HEAT PUMP (1.0 CREDITS) 5A-WATER CONSERVING SHOWERHEADS AND FAUCETS (0.5 CREDITS) 5C- ELECTRIC H T PUMP WATER HEATER (1.5 CREDITS) X ✓t _ 10) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate" and are available in '/<or'/z sheets. The Mason County Permit Center will also have some available. X `- L 11) A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. X 1 12) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) X -/�L BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 3 of 7 13) A concrete encased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-4000. X 44 . 14) Archaeological or historical resources, such as ruins, sites, buildings, artifacts, fossils, or other objects of antiquity that may have significance from an historical or scientific standpoint, which may be encountered by the developer/contractor, shall not be further disturbed. If the developer/contractor encounters any such artifacts, he/she shall immediately stop work and notify Mason County and the Washington State Department of Archaeology and Historic Preservati n. Failure to do so may result in civil penalties. X (_- 15) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and approved by Washington State Labor& Industries must be available on-site during the inspection. The Mason County Building Inspector will inspect the following: Verify that the system is installed in accordance with manufacturer specifications;The inspector will check to make sure that the exterior unit is permanently installed and supported, the exterior unit complies with required setbacks to property lines, fuel tanks are located at least 10-ft from the system, a source of ignition,all exterior penetrations are properly sealed,condensate lines are installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location outside of the foundation, copper refrigerant lines are insulated with '/2"thick continuous closed-cell foam insulation or better, indoor units are located at least 3-ft from smoke and carbon}monoxide alarms,and that modifications made to the structure, to install the unit, does not affect existing structural members. X 16) A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S2 designate wall(s) type NORTH AND EAST WALL with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. X 17) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 4 of 7 18) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. X 4 L- 19) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads con n ct with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X � L- 20) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17. Special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton WA 98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy inspections. ENGINEERED COMPACTION REPORT REQUIRED PRIOR TO FOUNDATION APPROVAL X �/° 21) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X -::4' L 22) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 5 of 7 23) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. X �- 24) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 25) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, r�u t be reviewed and approved by Mason County prior to construction. X C� 26) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be rTlAdUrior to requesting additional inspections. X BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 6 of 7 27) All property lines shall be clearly identified at the time of foundation inspection. X 28) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Coun ordinances and building regulations. X 29) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented tion from being taken. No more than one extension may be granted. X �- 30) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 31) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X W 32) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X 4 6, OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICAJION OF 180 DAYS WILL INVALIDATE THE APPLICATION. r//��,w 1,,2 Z16 Signature Date — l� -"OWNER REPRESENTATIVE - ONTRACTOR Print Name (Circle one to indicate) BLD2016-01102 Please refer to the following pages for conditions of this permit. Page 7 of 7 ON co ors `d't MASON COUNTY PERMIT NO. -- DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING• FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 r Mason County Mcrg. fff'426 West Cedar Street (3M Z7544676effiair ext 367 I854 PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext 35N E C E I V E D PLA 1-7A I N G BUILDING PERMIT APPLICATION 4 KNTTYRTION: C4NTRX4CTi3R 0,TF4RWkn40' r 15 X" Alder Str et NAME: k Y/v./ 0_HA N C HC= r l Llx NAME: ��L,;✓F f lyl�� MAILING ADDRE S: 7�(--; A/, /q_q7"] S%)C L i MAILING ADDRESS: (/3()A —62^'') A i/c_ E CITY: SW Z�,�i� STATE:�d ZIP: 3 3 CITY: STATE: )& ZIP: 3 73 PH0NE:.2 ;- - o 2 f CELL:.,?of• js 7- PHO :a2 S 3-,'7`D l 7zzCELL: EMAIL>4 c' V 16��Gtt Do • C6 � EMAIL: �YndQl/�!� 1�n�han�t<• Cow, L&I REG CJJ-3 3.0 EXP.1'LL U 'z v;7 PARCEL INFORMATION: /V DU Z ims?iy'_T�ZT LEGAL DESCRIPTION(ABBREVIATED): A U & t3 ie /a Za z,5776` i A/ SITE ADDRESS _2 3 D E CITY A L 4/1 iA44 -.,?e DIRECTIONS TO SITE ADDRESS.,E2eQLvj 6� 7' Chel7c7, 0 ''7A.� IA4,6q 3N j(_.7,64" IS PROPERTY WITHIN 200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND WETLAND ) SEASONAL RUNOFF❑ STREAM❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PR 7ECT-GREATER THAN 14% YES❑ NO a TYPE OF JOB: NEW/�r ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF.STRUCTURE.(RESIDENCE GARAGE-ETC-) IS USE: PRIMARY❑ SEASONAL NUMBER OF BEDROOMS �3 NUMBER OF BATHROOMS-3 DESCRIBE WORK SQUARE FOOTAGE: '/ 1ST FLOOR GIO 9 sq.ft. 2ND FLOOR 0 9 7_ sq.f1. 3RD FLOOR N,ff sq.ft. BASEMENT N�f} sq.ft. DECK rYIA sq.ft COVERED DECK N/fi sq.ft. STORAGE sq.ft. OTHER--f9*a- sq.ft GARAGE sq.ft- ATTACHED❑ DETACHED ❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN MAKE MODEL YEAR LENGTH B NUMBER OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further dedarathatlamenidled.to-receive this permit andto.do-the.wiork-as.proposed-Lhave.obtained-permissionfrom.aflthe.necessarx parties,including any easement holder or parties of interest regarding this project The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. IN OF THIS E IT APPLICATION OF 180 DAYS WILL I IVAL,DATE THE APPLICATION. X l d.P Si n x OWNE REPRESENTATIVE/CONTRACTOR Print Name (CIRCLE TO INDICATE) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUMDWFi OEPALRTMEN7 PLANNING DEPARTMENT FIRE MARSHAL Name e Parcel# - D -/9Qo2 BLD#,;?,':'D) Mason County BUILDING Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. simsl ,gaze.natti�it�xico,iop5,wawa�s, s,dtivcys, lo�oist�rege azcas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Suf Mee Typ& Leng* X WkWr = Arw •A4 d4'"err imw irr Awt Buildings X Z a X / _ zoo , Measurements for buildings are taken at the perimeter of the farthest projections(example: X = eaves/gutters) X Driveways X = X = Length of drive begins at the right of way X PwkingAreas, ' X 1 .2 X = Any paved,gravel or packed area per definition above table X = � , X = Patios/Walks 36 Any paved, gravel or packed area per definition X = abo+te tahte X = Others 4 X = r X i = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Sawa Marcel sivanwater Site Plan is ReQL&ed Total Impervious Surface Area (sum of all areas) 1,29 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. &%4 d u9m the iafcwmatioa you have provided a Starmwater Site Plan IS NOT required€Qx:tb&s development aativ". Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,ownees legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described pr o review and inspection as may be required. / X wn Agent/Contractor(circle one)Date: Q t}� /6 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 RECEIVED R9-. 1A/ A1-J-- n._ . C� 2 � FRANNING EXISTING 24' FENCE EXISTING FENCE EXISTING PROPOSED WELL PUMP SHED --- 4'X4' BEACH TRAIL t PA 1 N . . 2 NOV 0 9 2016 • •. P " :1>" . d • , '� � � D,GE�OFi1='II�C ./ / / / /• � /. /• /• /. /. / /• / /' / 1 / / �": . . • " - O (WETLAND SETBACK) / / / / / / / / / 615 W. Alger Street 17 10, T�EE/ /* Q- o 25' / / / / / /. /. / / / ./ / / o 26' CD /o / / / / / /C�TGORY 1 WETLANDS ^ EXISTI G GPC Z 7 1 - PROPOSED d / 85'X/4'0061KV A(L COUNTY ROAD SEASONAL DRAINAGE CULVERT EXISTING RWELECTRICAL OUTLETS & PVC CONDUIT MASON C®UN �V�� � SITE PLAN REQUIRED PLANNING ONSITE LEGEND PARCEL: 12220-50-19002 CHANGES SUP.-JET TO APPROVAL =NOIBUIL KENNY CHE PLANNING: ate I / : =NO BUILD ZONE ■1//VV//// =CLEARING LIMITS N" / =LOW AREAS 230 E NORTHBAY RD NG =TREES 12-OIA [PROJECTION LL cc7L F.C'rC�ARE f`,,4Ef SUREE: BELAIR, WA 98528 FRO�,R THE FURT;-IEST 'O =ROOF OVER HANGS(EAVES-16") �z =ROOF OVER HANGS(GABLE-12")OF THE BUILDING p =PROPOSED 10XIO•PUMP SHED ® OEDGE F FILL =GRINDER PUMP �SCALE: 1 20' SITE PLAN Os GRI =STEPS FENVIRONMENTALEALTH EXISTING 24' FENCE EXISTING FENCE EXISTING PROPOSED WELL PUMP SHED 1 d " 4'X4' BEACH TRAIL PA ECEIVED NOV 0 9 2016 " • � . . a • . D E,O Fib l lz� / / / ./ /. /. ./. / /- /� /� / / / / / O 615 W. A (WETLAND SETBACK)co c fcer Street Q c /R / / / / o `nIP.�rc 1 WETLANDS M EXISTI G 9 d GPC � . ,,( 9 PROPOSED / a6 X/4'�O6KVGAL/L COUNTY ROAD - SEASONAL DRAINAGE CULVERT EXISTING RWELECTRICAL OUTLETS & PVC CONDUIT AP pl joV ED NOV 2 y' TH HEq� 2016 CEW LEGEND PARCEL: 12220-50-19002 =SOIL LOG— NO KENNY CHE = BUILD ZONE =CLEARING LIMITS TRE-- _ �.S 230 E NORTHBAY RD =TREES��2-DIA j) =ROOF OVER HANGS(EAVES-16-) BELAIR WA 98528 =ROOF OVER HANGS(GABLE-12-) 1 =PROPOSED 10'X10'PUMP SHED Qa =EDGE OF FILLSCALE: 1"=20' SITE PLAN Qs =GRINDERER PUMP RI P © =STEPS