HomeMy WebLinkAboutCOM2003-00156 ReRoof Bldg 1 - COM Permit / Conditions - 10/6/2003 t MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)t27-7262
Phone: (360)427-9670,ext.352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton,WA 98584
ot$
COMMERCIAL BUILDING PERMIT COM2003-00156
OWNER: BLUE HERON CONDOMINIUM ASSOC RECEIVED: 9/12/2003
CONTRACTOR: FIELDS ROOF SERVICE INC (253) 852-4974 LICENSE: FIELDRS2621_1 EXP: 9/25/2005 ISSUED: 10/6/2003
SITE ADDRESS: 6520 E STATE ROUTE 106 UNION
EXPIRES: 4/6/2004
PARCEL NUMBER: 322335289004
LEGAL DESCRIPTION: BLUE HERON CONDOMINIUM PHASE 1 1/6 INT. UNIT 8-9 PH 1 UND. INT. IN COMMON AREAS & FACILITIES TSI J E 6520
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
COMMERCIAL REROOF BUILDING 1 BELFAIR TO HWY 106 TO UNION, PAST ALDERBROOK ON THE LEFT
General Information Construction &Occupancy Information
Type of Use: Condominiums Insp.Area: No.of Units: Type of Constr.: V-N
Type of Work: RRF Fire Dist.: 6 No.of Bathrooms: Occ.Group: R-1
No.of Stories: Occ. Load:
Valuation: $ 15,115.00
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPA?: Comp.Plan Desg.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2003-00156 Please refer to the following pages for conditions of this permit. 1 of 4
r Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Building Permit Fee KC Q/1?/9nn.'t cZ9R5 95 R*?gnn3nn
Plan Check Fee KC o/igonn.i c179 Al C1?nn'tnn
Building State Fee IPM Qi,in/9nns ea-,n -,99nn-Ann
Total $442.16
CASE NOTES FOR
COM2003-00156
CONDITIONS FOR
COM2003-00156
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-098 The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X
2) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY
BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION
FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF
OWNER/G0N71RACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
X �I t
3) ENCLOSED ROOF SYSTEM'§ THAT ARE EXPOSED TO THE SHEATHING SHALL BE INSULATED TO A MINIMUM R-30 AND INSPECTED
PRIOR TO COVER. X
4) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED TO A MY IMYM OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH
CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X 1'
5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-compl am-,
X with Mason County ordinances and building regulations.
� /�
6) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE
PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE O.FU41E OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION.
CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x
7) CONSTRUCTION PROCESS T.. BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM
BUILDING CODE.x ?(
8) THE DEMO',ITI9N AND DISPOSAL OF DEMOLITION DEBRIS MUST MEET REQUIREMENTS AS PER MASON COUNTY REGULATIONS.
X �(
COM2003-00156 2 of 4
his permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.
� f�f
OWNER AGENT 1 DATE: �� -" D('0 C _
COM2003-00156 3 of 4
n •
CONCRETE MECHANICAL MANUFACTURED HOME
N
o Footings /Setbacks Date By Ribbons
`'' Date B Gas Piping Date B
o y Ip� g y
Foundation Walls Date B y Set-up
Date By INSULATION Date By
B G / Slab Insulation Floors Final
Date By Date By Date By
FRAMING Walls FIRE DEPT
Date By Date By Date By
PLUMBING Attic OTHER
Groundwork Date By
Date By WALLBOARD NAILING
D.W.V. Date By
Date By FINAL INSPECTION
Water Line Date 1 / 0 By L6iL