Loading...
HomeMy WebLinkAboutBLD2024-00668 MFG Home - BLD Application - 5/29/2024 MASON COUNTY Permit No: eLOzozg'0 COMMUNITY DEVELOPMENT -PePermit Assistance Center, Building,Planning BUILDING PERMIT APPLICATION RECEIVED PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION- NAME:EMPIRE HOME CONSTRUCTION,LLC MASON COUNTY EXCAVATING,1 13 '/W4 NAME: MAILING ADDRESS:P.O.BOX 241, MAILING ADDRESS:30 E HAR BLVD, CITY:KELSO STATE:WA ZIP:98626 CITY:SHELTON S PHONE#1:LOREN 360-751-1745 PHONE:360-490,3144 CELL: 360-490-3144 "7WI PHONE#2:DAVID 360-751-8062 EMAIL:MASONCOUNTYEXCAVATINGQYAHOO.COM EMAIL:LORENDUVALLQGMAIL.COM L&I REG#MAS6NE915PM EXp, 3 /18/26 PRIMARY CONTACT: OWNER p CONTRACTOR❑ OTHER❑ NAME DAVID DUVALL EMAIL DAVIDLDUVALL80@GMAIL.COM MAILING ADDRESS PO BOX 241 CITY KELSO STATE WA ZIP 98626 PHONE 360-751.8062 CELL SAME PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 32021-58-04059 ZONING RR f LEGAL DESCRIPTION(Abbreviated) SHORECREST BEACH ESTATES#1 BLK:4 LOT:59 FIRE DISTRICT FD5 SITE ADDRESS 110 E Kingston Way CITY SHELTON DIRECTIONS TO SITE ADDRESS Follow WA-3 N,E Agate Rd and E Crestview Dr to E Kingston Way IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO❑r SNOW LOAD:30 psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW E] ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.)RESIDENTIAL IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(whole Bldg)❑� YES(Part(s]of Bldg)❑ NO❑ DESCRIBE WORK NEW MFH SOUARE FOOTAGE:(proposed) 1ST FLOOR 1296 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK 32 sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE CLAYTON MODEL UNDER PRESSURE yEAR2024 LENGTH 48FT WIDTH 27FT BEDROOMS 3 BATHS 2 SERLA.DNUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC E] SEWER❑ / NEW I] EXISTING❑ PLUMBING IN STRUCTURE? YES E] NO❑ Ifyes,attach completed Water Adequacy Form PERIMETERNOUNDATION DRAINS PROPOSED? YES❑ NOD EXISTING SQ.FT. EXISTING BEDROOMS 3 PROPOSED BEDROOMS 3 TOTAL BEDROOMS 3 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null$void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON COUNTY CODE 14.08.42) X Signature of OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH Mason County Building Division MANUFACTURED HOME PLAN REVIEW SPECIFICATIONS UNIT INFORMATION: *****Snow Load 30psf Make CLAYTON Model UNDER PRESSURE Year _jj*jj@r yam' c �) Square feet 1296 Width 27FT Length 48FT Single/Double/triple-wide (indicate) NEW or Replacement (indicate) All footings must be min. 12" below natural grade within 24" of the skirting when perimeter blocking is required. When a relocated unit AND the manufactures specification are not available the HUD 24 CFR 3285 must be used for required pier plan standards and set-up Allowable Pressure(Pound Per Square Foot) No Allowances made for overburden pressure,embedment depth,water table height,or settlement problems Soil bearing is assumed at 1500 psi If set-up is using a greater soil bearing capacity a soil report from a design professional is required Fill(compact or uncompacted) Compaction Report required through Special analysis Peat or organic clays Compaction Report required through Special analysis SET UP SPECIFICATIONS: 5a Manufacturer's Pier Plan 7 HUD24 CFR part 3285 FOUNDATION: Check the type of foundation and attach detail plans from manufacturer's or the ANSI A225.1/ HUD24 CFR part 3285 0 Pads 7 Concrete (pre-cast) 34 ABS Pads (Poly) provide manufactures specification with capacities. O Continuous concrete footing (runners) O Slab ANCHORING: ® Ground O Magnum O Concrete-2500 PSI 7 J-bolt 7 Expansion bolt For new units,this information can be obtained from the home retailer or contractor. Previously owned units, which manufacture's instruction are not available must utilize the HUD24 CFR part 3285 code for installation. Washington State law requires that a certified installer install manufactured homes. The undersigned I hereby acknowledge he/she does understand that the Mason County submittal and review processes will be based on the information provided herein and will be verified at time of inspection. X Applicant/Dealer/Installer(indicate) Date NameEMPIRE HOME CONSTRUCTION, LLC Parcel# 32021-58-04059 BLD# 2,0 -ap(p(pg Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment', with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure, and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings 49 X 28 = 1372 X = Measurements for buildings are taken at the perimeter of the farthest projections (example: X eaves/gutters) X = Driveways 30 X 15 = 450 X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks 4 X 4 = 16 4 X 4 = 16 Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 1854 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read, acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that e information provided is accurate and employees of Mason County are granted access to the above- described property for re ie nspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Su face Area is GREATER THAN 2000 Square Feet,please read, acknowledge and sign the information provide n page 2 of 2. Page 1 of 2 Name EMPIRE HOME CONSTRUCTION LLC Parcel# 32021-58-04059 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: httn//www.co.mason.wa—us/code/commissioners/index htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have, a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 PgL.VZO29-00toc g E , R1 4- 1 t � Z-..�.z�`.,• �i •ram,, �:;. fl f�$KtN� iJ 5 s ; s � s (> O/ j"txczo'visusi AIar--.- 500 eano: / O UWeter BNR-500 A:r:Taz ^C7 Q! � M IN C -,,Coo Gaiics'=Puss.:,_na--be` O 6 V"aive Con=oi Box >_ } a cd }, 'a d d a EH APPROVEDth{ 0 y o Rhonda Thompson 06/21/2024 {{^/, �• _ iiN E U7 Y Y .%,yfa• 37CU Jog •••(� Q� o c 0PAULA JOY JOHNSON'.. Q nUc7c Q E �►� YN Y o Z o o CU U E�fP1fiE8 !! N W C13 a C Q Z a) a) N EH Setbacks dU) In o w A.) Drainfield/Reserve requires 10'setback from footing/foundations + b ro o B.)Septic tank(s)requires 5'setback from all footing/foundations m C.) No foundation/Perimeter Drains within 30ft,downgradient of �- V i D c a ro N 2 Drainfield/Reserve area � � a n D.) No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area C'I CS3, -3 ov 'N -- Ao�. Lo 0 10, �OVL St'c r\ ",jQ 06� MAY 14 IASOv key: fro. oi WA 4'-"C)O C-ajjc�--- 03 5100349 PAULA JOY jj HNSDN*. N -500 ATv Exxpi 11 =p OValve Cf,,=,-=Ol Box MASON COUNTY Mason County Permit Center Use: COMMUNITY SERVICES �V 17024 - 000gko Building,Planning,Environmental Health,Community Health �� 615 W.Alder St.—Bldg.8,Shelton,Wa 98584 Date Rcvd Phone:(360)427-9670 ext.352♦Fax:(360)427-7798 Request for Administrative Variance for Reduction in the Required Setbacks 615 W.Alder Strut For administrative review,the minimum variance on a setback request is 5 feet from the side yard lot lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction requires a standard variance. Setbacks are measured from the furthest projection of the structure, including roof eaves and glitters. Applicant/Owners: 01 Pi2 i*`-It ck'S?rycy UN L( L- Mailing Address: GE)k 2 y/ City: XtZS-D State: W A- Zip: CIE6 2 G Telephone: U -7 5'/- /7 y Email: fUl P.rrl c1" ^, /1 CJ �M If this reduction is tied to a building permit,please give permit case number. BLD 202A - 6010te 96 Parcel Number(s): 32021 - 5B- 046S9 Zoning_P45 Site Address: 110 E KYtataST'DN VNM SVACLTON + WA OMSSA Requested setback variance: 10 ft. ❑ Rear ❑ Side 5 ft ❑ Front ❑ Rear SLR ide ft. ❑ Front ❑ Rear ❑ Side ft ❑ Front ❑ Rear ❑ Side Front Setbacks—From access easements and road right of ways. Minimum 10 feet. Rear Setbacks—From the rear property line. Minimum 10 feet. Side Setbacks—From the side property line. Minimum 5 feet except for certain shoreline designations. An illustrated site plan is required. Your site plan must show the following: north arrow, abutting street or easements, and set backs to all property lines and existing buildings, slopes, surface water,wetlands, critical areas, septic,well and driveway. Show all proposed new development. FRONT AND OR REAR YARD REDUCTION REOUESTS: For existing lots of record as of March 5, 2002; You must meet one of the following: 1) One of the following exists on the lot(check all that apply): a) steep slopes, wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ c) lot width at the front yard line of no more than 50 feet; —-I>lk d) lot size of no more than one-fourth acre; ❑ e) existing improvements of buildings, septic systems, and well areas. SIDE YARD REDUCTION REQUESTS: For existing lots of record as of March 5, 2002; You must meet one of the following: 2) One of the following exists on the lot(check all that apply): a) steep slopes,wetlands, or streams present; ❑ b) soils that restrict building or septic development; ❑ c) lot width at the front yard line of no more than 50 feet; Qr d) lot size of no more than one-half acre; ❑ e) existing improvements of buildings, septic systems, and well areas. Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard for Rural Residential 2.5, 5, 10, or 20 zones. re j2t_s`f�CT W-5 Owner/Agent(please indicate) Z Sign a Date Official Use Only Approved by: 67CA L. 'J AA 500 V(T� Date Denied by: Date Reason for denial: