Loading...
HomeMy WebLinkAboutBLD2022-01051 SFR Occupancy - BLD Inspections - 6/25/2024 CERTIFICATE OF OCCUPANCY Mason County, WA OWNERS NAME: Wesley Hawkins ET AL OWNER'S ADDRESS: 7055 Condon Dr. San Diego, CA 92122 SITE ADDRESS: 390 SE Dahman Rd. Shelton, WA 98584 BUILDING PERMIT NUMBER: BLD2022-01051 DESCRIPTION: Single Family Residence BUILDING OFFICIAL: Todd Cunningham TELEPHONE NUMBER: (360) 427-9670 ext. 352 CODE/EDITTION: 2018 lBC/lRC USE OF STRUCTURE: Dwelling w/garage OCCUPANCY: R-3 OCCUPANT LOAD: N/A TYPE OF CONSTRUCTION: VB SPRINKLER SYSTEM REQUIRED: No This structure has been inspected for compliance with the requirements of this code for occupancy and the use for which the proposed occupancy is classified. CONDITIONS OR STIPULATIONS: All storm water and life safety elements must be maintained INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2022-01051 PROJECT ADDRESS 390 SE Dahman Rd Shelton, WA 98584 PARCEL# 319142300000 PROJECT DESCRIPTION Adair Homes: NEW SFR W/ATTACHED GARAGE OWNER WESLEY HAWKINS ADDRESS 7055 CONDON DR PHONE 858-232-3168 CONTRACTOR ADAIR HOMES INC ADDRESS 2303 93RD AVE SW PHONE 360-352-8571 CONTRACTOR LICENSE ADAIRW262RZ LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments Setback Inspection Rough-Plumbing Inspection !b a.{ 7-1 Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Insulation Inspection a Underfloor Inspection D&X7g Conti_ikti6n°hns-beer verified by- Shearwalllnspection 111 BLD-Final Inspection Framing Inspection -�v�- �«r PAT ar t MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext. 352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER:,?j\C�Z-O2--2-D\0P.,) ADDRESS/LOCATION: FINDINGS• 5 . r Or "i Yr � 1 r n rT e- rA - 2 �l Items listed above must be corrected to gain compliance. THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ,Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: - ;9 1,`a?) ❑ Please contact our office regarding possible Department: 1� structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector:N _ L<- r �S CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: G D�Oad2— Q I pS I ADDRESS/LOCATION: ago 5c J)AIPA N 0) FINDINGS: _- CA Rg66 Pbg`T4(. A) 1 o) E '1 on e4es. i 4-1-\ `n .0l1 a c,,re�yt� < TDSci^V 3X 6Jock;q nol ipyAlt<d ti4- 04 r%Wc- ol- /:'19 �{'r� ,�J +4 a es Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. ❑ OK to Date: Please contact our office regarding possible Department: g t-P structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector: CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 r COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building, Planning, Environmental Health,Community Health • 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: &D-2�9- *0 Q 10�- ADDRESS/LOCATION: ?do S-C ,D -4qM#A2 1W FINDINGS: —A90 AccsS 7o 6A7ZA66 1. 7t)E ?o 1,JE7 CoAt pcT� Items listed above must be corrected to fain compliance. 11 THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. ❑ OK to Date: /D-!0 -.23 ❑ Please contact our office regarding possible Department: $Lp structural damage incurred by recent Inspector: DED "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 360-482-5269 Elma ext.352 Building, Planning, Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: ,2c7ZZ.— C)1,oe:)1 ADDRESS/LOCATION: h FINDINGS: kJ Items listed above must be corrected to lain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. all for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: �"` 3 ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: 6 S( "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: At D2o?-2 " 010S1 ADDRESS/LOCATION: 31?0 SSG L�,ihPAI*t/ )0 FINDINGS• j 11 ,] 1 A .- /eJ1of ,rt eAC40-1 - i qX1)"t /10-1 iS 6C. Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. IN Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date:_ -90-?q Please contact our office regarding possible Department: ISLD structural damage incurred by recent Inspector: j "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 io COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 5J-1)2022— 010,9 t / ADDRESS/LOCATION: 3-1 O 5E 1- Nat K Z.f Sic 140vi FI INGS• heledcd -4o CCou-o,.-F Sew�tL Te401 Wr Y- G He. re✓ ✓.< vivr *- q !I elet 40(4 1w�lc a It14&u 4-4 r a t -1-�r 2 -}tom►� 74 L`o C,�tGc C, t-AA <Cc-At--A 311 -2. . S aL -fi,L 20►g R.Cr. 3� aYP<u Iles GVr.G -f ✓u�.-f� �-30 � ( � yr w ots evz 4v Ln r4 -Cpoij Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: b-I 1—24 ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: J TL "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 c Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov F 2-01051 NEW SINGLE FAMILY RESIDENCE ESCRIPTION: ADAIR HOMES: NEW SFR W/ATTACHED ISSUED: 01/06/2023 ESS: 390 SE DAHMAN RD SHELTON EXPIRES: 07/05/2023 PARCEL: 319142300000 APPLICANT: HAWKINS,WESLEY OWNER: WESLEY HAWKINS 7055 CONDON DR 7055 CONDON DR SAN DIEGO,CA 92122 SAN DIEGO, CA 92122 858-232-3168 OWNER'S REP: JORDAN, FREDRICK LEE OWNER'S REP: JORDAN, FREDRICK LEE 100TH ST SW SUITE 25 100TH ST SW SUITE 25 LAKEWOOD,WA98499 LAKEWOOD,WA98499 360-718-9180 360-718-9180 GENERAL CONTRACTOR'S LICENSE: ADAIR HOMES INC License: ADAIRH'262RZ 2303 93RD AVE SVbOLYMPIA,WA98512 Expires: 01/09/2023 360-352-8571 VALUATIONS: FEES: Paid Due R-3 VB Residential, one- 1349.00 $200,097.17 Technology Surcharge $68.34 $0.00 and two-family Plumbing Fees $126.00 $0.00 U VB Utility, miscellaneous 400.00 $23,952.00 Plan Check Fee $1,207.02 $0.00 Planning Review Fee $240.00 $0.00 Mechanical Base Fee $30.00 $0.00 State Fee-Residential $6.50 $0.00 Building Plan Review/Change of $125.00 $0.00 Use-Onsite Sewage Mechanical Fees $172.00 $0.00 Building Permit Fee $1,856.96 $0.00 Plumbing Base Fee $25.00 $0.00 Geo-Tech/Stormwater Review $300.00 $0.00 Wetland Delineation Review $160.00 $0.00 Total: $224,049.17 Totals : $4,316.82 $0.00 Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 1 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01051 FIXTURES City Mechanical Fixtures Qty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Clothes Washers 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers 1.0000 Ductless Heat Pump 1.0000 FLOOR SINK 1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks 1.0000 Wood/Gas/Pellet Stove(s) 1.0000 Number of Water Heaters and or Vent 3.0000 Spot Vent Fan(s) 2.0000 Number of Bath Tubs 2.0000 Number of Showers 2.0000 Number of Toilets 3.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Rough-Plumbing Inspection Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Inspection Insulation Inspection Underfloor Inspection Connection has been verified by Health or Utilities Shearwall Inspection BLD-Final Inspection Framing Inspection CONDITIONS * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. * Stormwater Management shall be accomplished per the submitted, approved plans and report prepared by the Iris Group, dated 4/20/22 and stamped by Nicholas D. Taylor, PE.. Any proposed revision to the plan must be approved by the Engineei and Mason County. The Project Engineer must inspect or accept the stormwater improvements prior to final occupancy. Printed by:Adana Paysse on:01/06/2023 10:05 AM Page 2 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O22-01051 * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek,or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls,foundation (slab, basement wall, crawlspace wall and/or floor),and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in '/<or sheets. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 3 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01051 Adopted Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. 2 Heat pump 1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by5% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M 1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.5 Air-source, centrally ducted heat pump with minimum HSPF of 11.0. 4 5.5 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. 5 * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. All property lines shall be clearly identified at the time of foundation inspection. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 4 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O22-01051 * Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * This project is flow control exempt as there is less than 0.10 cfs/sec. increase in the 100-year flow frequency from the TDA. Roof runoff will be collected and discharged to infiltration trenches per plan dated 4/20/22. Driveway runoff will sheetflow to a gravel dispersion strip per same plan. Disturbed surfaces will comply with Post Construction Soil Quality and Depth BMP. * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 5 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O22-01051 * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.)Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 6 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2022-01051 * New impervious surfaces or native vegetation removal within stream buffers prohibited. Stream buffers are 75'or as amended. * PLANNING SETBACKS Front :25'**, Side and Rear:20'**. Measured from furthest projection **Must adhere to 90'stream setback as well as listed setbacks above. Site plan as shown meets setbacks. There is room to move at least 15' in any one direction per planning setbacks. If moving both north and east, setbacks need to be closely evaluated. *Subject to EH Setbacks I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulatin construction or the performance of construction. Issued By: �, f�� Contractor or Authorized Agent: Date: U V 1 Printed by:Ariane Paysse on:01/06/2023 10:05 AM Page 7 of 7